Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature sensing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Significance of vegetation in interpreting thermal radiation from a terrestrial surface

The regions between crop rows are modeled as infinitely long diffuse cavities. Geometrical view factors are calculated, accounting for reflected radiation emanating internal to the cavity and from the background sky. A 'cavity' emissivity dependent on local geometry is defined to allow for correcting apparent temperatures to true temperatures. The total emissivity appropriate for correcting aircraft thermal data is then calculated by averaging all emissivity components to account for soil, crop, and background. It is shown that even for the lowest crop and vegetation emissivities, if the crop height-to-spacing ratio is greater than unity, the composite emissivity is greatly increased, giving rise to a decreased error in remotely sensed temperature data.

Sutherland, R. A.↗

Power system applications of fiber optic sensors

This document is a progress report of work done in 1985 on the Communications and Control for Electric Power Systems Project at the Jet Propulsion Laboratory. These topics are covered: Electric Field Measurement, Fiber Optic Temperature Sensing, and Optical Power transfer. Work was done on the measurement of ac and dc electric fields. A prototype sensor for measuring alternating fields was made using a very simple electroscope approach. An electronic field mill sensor for dc fields was made using a fiber optic readout, so that the entire probe could be operated isolated from ground. There are several instances in which more precise knowledge of the temperature of electrical power apparatus would be useful. This report describes a number of methods whereby the distributed temperature profile can be obtained using a fiber optic sensor. The ability to energize electronics by means of an optical fiber has the advantage that electrical isolation is maintained at low cost. In order to accomplish this, it is necessary to convert the light energy into electrical form by means of photovoltaic cells. JPL has developed an array of PV cells in gallium arsenide specifically for this purpose. This work is described.

Johnston, A. R.↗

Program to design, fabricate, test, and deliver a thermal control-mixing control device, phase 1

The development of a sensor capable of detecting temperature changes as a function of viscosity changes, was completed. This type of sensor, consisting of an orifice bridge circuit, resulted in a device with a threshold above internally generated noise of 0.8C (1.5F). Data were obtained using a noise free Freon source provided by an air pressurized bladder. Tests conducted to operate the sensor from a typical Freon centrifugal pump system employing an air bubble accumulator for noise attentuation disclosed the sensor could be used only to sense temperature changes greater than 3.3C (6F) because of the excessively noisy output. This is attributed to the high frequency-pressure fluctuations in the Freon supply to the sensor.

Thurston, T. S.↗

Advanced sensors for spaceborne measurements of the earth's atmosphere

Concepts involved in remote sensing from space are reviewed, together with performance requirements of proposed and planned equipment. Attention is focused on measurements of the troposphere, particularly meteorological variables and chemical species. The principles of absorption, using either passive or active sensors, emission detection, fluorescence measurements, and EM radiation scattering are outlined. The proposed NASA Windsat, using a CO2 laser from the Orbiter or from an 800 km orbit spacecraft to measure low-level wind speeds is described, as are the uses of the AMTS atmospheric sounder instrument for IR atmospheric temperature sensing and a 20-channel microwave radiometer to detect moisture profiles in the water vapor bands. Additionally, a microwave pressure sounder to detect backscattered signals at 60 GHz is outlined, along with lidar pressure and wind speed measurement methods.

Hinkley, E. D.↗

Temperature, stress, and corrosive sensing apparatus utilizing harmonic response of magnetically soft sensor element (s)

A temperature sensing apparatus including a sensor element made of a magnetically soft material operatively arranged within a first and second time-varying interrogation magnetic field, the first time-varying magnetic field being generated at a frequency higher than that for the second magnetic field. A receiver, remote from the sensor element, is engaged to measure intensity of electromagnetic emissions from the sensor element to identify a relative maximum amplitude value for each of a plurality of higher-order harmonic frequency amplitudes so measured. A unit then determines a value for temperature (or other parameter of interst) using the relative maximum harmonic amplitude values identified. In other aspects of the invention, the focus is on an apparatus and technique for determining a value for of stress condition of a solid analyte and for determining a value for corrosion, using the relative maximum harmonic amplitude values identified. A magnetically hard element supporting a biasing field adjacent the magnetically soft sensor element can be included.

Grimes, Craig A.↗

Gas Flow Detection System

This system provides a portable means to detect gas flow through a thin-walled tube without breaking into the tubing system. The flow detection system was specifically designed to detect flow through two parallel branches of a manifold with only one inlet and outlet, and is a means for verifying a space shuttle program requirement that saves time and reduces the risk of flight hardware damage compared to the current means of requirement verification. The prototype Purge Vent and Drain Window Cavity Conditioning System (PVD WCCS) Flow Detection System consists of a heater and a temperature-sensing thermistor attached to a piece of Velcro to be attached to each branch of a WCCS manifold for the duration of the requirement verification test. The heaters and thermistors are connected to a shielded cable and then to an electronics enclosure, which contains the power supplies, relays, and circuit board to provide power, signal conditioning, and control. The electronics enclosure is then connected to a commercial data acquisition box to provide analog to digital conversion as well as digital control. This data acquisition box is then connected to a commercial laptop running a custom application created using National Instruments LabVIEW. The operation of the PVD WCCS Flow Detection System consists of first attaching a heater/thermistor assembly to each of the two branches of one manifold while there is no flow through the manifold. Next, the software application running on the laptop is used to turn on the heaters and to monitor the manifold branch temperatures. When the system has reached thermal equilibrium, the software application s graphical user interface (GUI) will indicate that the branch temperatures are stable. The operator can then physically open the flow control valve to initiate the test flow of gaseous nitrogen (GN2) through the manifold. Next, the software user interface will be monitored for stable temperature indications when the system is again at thermal equilibrium with the test flow of GN2. The temperature drop of each branch from its "no flow" stable temperature peak to its stable "with flow" temperature will allow the operator to determine whether a minimum level of flow exists. An alternative operation has the operator turning on the software only long enough to record the ambient temperature of the tubing before turning on the heaters and initiating GN2 flow. The stable temperature of the heated tubing with GN2 flow is then compared with the ambient tubing temperature to determine if flow is present in each branch. To help quantify the level of flow in the manifolds, each branch will be bench calibrated to establish its thermal properties using the flow detection system and different flow rates. These calibration values can then be incorporated into the software application to provide more detailed flow rate information.

Moss, Thomas↗

Miniature bioelectric device accurately measures and telemeters temperature

Miniature micropower solid-state circuit measures and telemeters the body temperature of laboratory animals over periods up to two years. The circuit employs a thermistor as a temperature sensing element and an fm transmitter. It is constructed from conventional discrete components or integrated circuits.

Fryer, T. B.↗

Multichamber controllable heat pipe

Valve throttles transfer of vapor between heat input surface and heat rejection surface of heat pipe to control rate of transfer of energy. Valve is operated by control signals which sense temperatures or pressures.

Shlosinger, A. P.↗

Pulse-width-modulated device for precision temperature control

Temperature controller is described which reduces difference between temperature oscillations about control point. Standard temperature-sensitive resistor element is utilized which is highly stable and reproducible. Temperature sensing circuitry is conventional dc bridge with power supplied by battery or highly regulated supply source.

Heyser, R. C.↗

Digital magnetic temperature transducer.

A new digital magnetic temperature transducer is reported. The device utilizes the discontinuous behavior of the initial permeability with temperature at the Curie temperature of some magnetic materials. Since the Curie temperature is determined by the chemical and crystallographic composition of the particular material only, the transducer requires no calibration and has extremely high stability and reproducibility with time. The output of the transducer is inherently digital and, therefore, is directly compatible with the digital information processing and control without A/D conversion. The temperature-sensing portion of the transducer consists only of magnetic cores and wire and, therefore, has extremely high reliability, is shock and radiation insensitive, small, and virtually indestructible.

Tchernev, D. I.↗

Retrieval of atmospheric temperature profiles by a scanning microwave spectrometer

The Nimbus-6 satellite carries a scanning microwave spectrometer (SCAMS) experiment. The five frequency bands observed are near 22.2, 31.6, 52.8, 53.8, and 55.4 GHz. The calibration system permitted preflight calibration to an accuracy of about 1 K. In orbit, small empirical corrections were made to the calibration constants to obtain agreement in the mean of SCAMS measurements with computations based on conventional data analyzed by the National Meteorological Center (NMC). Global maps of temperature profiles were retrieved from the SCAMS measurements by a statistical method. Using the NMC analysis as the verification, RMS errors in level temperatures range of about 2-4 K, depending on altitude. Errors for layers of octave extent in pressure are uniformly about 2 K. Theoretical computations show that additional spectrometer channels would improve temperature sensing performance

Rosenkranz, P. W.↗

High resolution radiometric measurements of convective storms during the GATE experiment

Using passive microwave data from the NASA CV-990 aircraft and radar data collected during the Global Atmospheric Research Program Atlantic Tropical Experiment (GATE), an empirical model was developed relating brightness temperatures sensed at 19.35 GHz to surface rainfall rates. This model agreed well with theoretical computations of the relationship between microwave radiation and precipitation in the tropics. The GATE aircraft microwave data was then used to determine the detailed structure of convective systems. The high spatial resolution of the data permitted identification of individual cells which retained unique identities throughout their lifetimes in larger cloud masses and allowed analysis of the effects of cloud merger.

Fowler, G.↗