Search NASA⌕ Search

SEARCH · Search NASA

Results for “testing and evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Development and testing of a performance evaluation methodology to assess the reliability of occupancy sensor systems in residential buildings

With the emergence of advanced occupancy sensor technologies to better detect occupancy in buildings, a universal methodology and metrics are required to evaluate and report sensor systems’ reliability and compare the performance across multiple sensor systems. Herein this research presents a methodology to assess the reliability of occupancy sensor systems in residential buildings in a controlled laboratory environment, including both “typical” and “failure” testing scenarios. The developed methodology was then implemented to evaluate a novel occupancy detection sensor system’s reliability. “Typical” testing evaluates the overall accuracy of the sensor system, which suggest how reliable the occupancy sensor system is over time. Results show that on average, the precision and recall are 0.75 and 0.70, indicating similar numbers of false positives and false negatives across the dataset. The overall accuracy of the tested sensor system was 62.4% to 76.4%. Failure testing results indicate whether there are influential variables impacting the sensor performance. For the tested sensor system, the number of occupants, presence of large objects, presence of interior light sources, and number of doors are not influential, while lighting level, location of occupants, additional door in the entry/exit area, and having the TV on are variables determined to impact the sensor system performance.

47 OTHER INSTRUMENTATION↗

2019 Hyperion 5313A and 5119A Infrasound Sensor Type Approval Evaluation

Sandia National Laboratories has tested and evaluated two variations of a new model of infrasound sensor, the Hyperion 5313A and 5119A. The purpose of this infrasound sensor evaluation is to measure the performance characteristics in such areas as power consumption, sensitivity, full scale, self-noise, dynamic range, response, passband, sensitivity variation due to changes in static pressure and temperature, and sensitivity to vertical acceleration. The Hyperion infrasound sensors are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2022 MB3a Infrasound Sensor Type Approval Evaluation

Sandia National Laboratories has tested and evaluated an updated version of the MB3a infrasound sensor, designed by CEA and manufactured by SeismoWave. The purpose of this infrasound sensor evaluation is to measure the performance characteristics in such areas as power consumption, sensitivity, full scale, self-noise, dynamic range, response, passband, sensitivity variation due to changes in barometric pressure and temperature, and sensitivity to acceleration. The MB3a infrasound sensors are being evaluated for use in the International Monitoring System (IMS) of the Preparatory Commission to the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

2022 Chaparral 64S Infrasound Sensor Type Approval Evaluation

Sandia National Laboratories has tested and evaluated a new version of the Chaparral 64S infrasound sensor, designed and manufactured by Chaparral Physics. The purpose of this infrasound sensor evaluation is to measure the performance characteristics in such areas as power consumption, sensitivity, full scale, self-noise, dynamic range, response, passband, sensitivity variation due to changes in barometric pressure and temperature, and sensitivity to acceleration. The Chaparral 64S infrasound sensors are being evaluated for use in the International Monitoring System (IMS) of the Preparatory Commission to the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

2023 Reftek Wrangler Digitizer Type Approval Evaluation

Sandia National Laboratories has tested and evaluated the Reftek Wrangler digitizer. The Wrangler digitizers are intended to record sensor output for seismic and infrasound monitoring applications. The purpose of this digitizer evaluation is to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The Wrangler digitizers are being evaluated for potential use in the International Monitoring System (IMS) and On-site Inspection (OSI) components of Comprehensive Nuclear-Test-Ban Treaty (CTBT).

58 GEOSCIENCES↗

2023 Reftek Colt Seismometer Exploratory Evaluation

Sandia National Laboratories has tested and evaluated three Colt broadband seismometers designed and manufactured by Reftek. The purpose of this seismometer evaluation is to measure performance characteristics in areas such as power consumption, sensitivity, frequency response, full scale, self-noise, dynamic range, calibration system response, and passband. The Colt model of sensors are being evaluated to explore the potential for a future seismometer Type Approval process in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT).

47 OTHER INSTRUMENTATION↗

2023 T120 Horizon and Slim Posthole Seismometer Exploratory Evaluation

Sandia National Laboratories has tested and evaluated a suite of four T120 broadband seismometers designed and manufactured by Nanometrics. Specifically, two T120 Horizon V2 sensors, one T120 Horizon V1 sensor and one T120 Slim Posthole (PH) sensor were evaluated. The purpose of this seismometer evaluation is to measure performance characteristics in areas such as power consumption, sensitivity, frequency response, full scale, self-noise, dynamic range, calibration system response, and passband. The T120 model of sensors are being evaluated to explore the potential for a future seismometer Type Approval process in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT).

47 OTHER INSTRUMENTATION↗

Kinemetrics Q330M+ Digitizer Evaluation

Sandia National Laboratories has tested and evaluated a new digitizer, the Q330M+, manufactured by Quanterra, a division of Kinemetrics Inc. This digitizer is used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as sensitivity, input impedance, power consumption, self noise, dynamic range, system noise, relative transfer function, analog bandwidth, modified noise power ratio, harmonic distortion, common mode, cross talk, timing tag accuracy and timing drift. The Q330M+ provides six channels of 24 bit digitization, all of which may be transmitted utilizing CD1.1 protocol, at multiple sample rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Guralp Affinity Digitizer Evaluation

Sandia National Laboratories has tested and evaluated a new digitizer, the Affinity, manufactured by Guralp Systems. This digitizer is used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as sensitivity, power, self-noise, dynamic range, system noise, relative transfer function, modified noise power ratio, analog bandwidth, harmonic distortion, common mode, cross talk, timing tag accuracy and timing drift. The Affinity provides eight, rather the typical six, channels of 24 bit high sample rate digitization, all of which may be transmitted utilizing the CD1.1 protocol, at multiple sample rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of DTRA/NACT Next Generation Digitizer Evaluations

Sandia National Laboratories has tested and evaluated three digitizers, the Affinity, manufactured by Guralp Systems, the Centaur, manufactured by Nanometrics, and the Q330M+, manufactured by Quanterra, a division of Kinemetrics. These digitizers are used to record sensor output for seismic and infrasound monitoring applications. The purpose of this document is to highlight various results and observations collected during comprehensive evaluations conducted on each unit.

42 ENGINEERING↗

2025 CEA SMAD Digitizer Type Approval Evaluation

Sandia National Laboratories has tested and evaluated an updated SMAD digitizer, developed by the French Alternative Energies and Atomic Energy Commission (CEA). The SMAD digitizers are intended to record sensor output for seismic and infrasound monitoring applications.

47 OTHER INSTRUMENTATION↗

A Cybersecurity Event Simulation Tool and Platform

Digital Instrumentation and Control Systems (ICSs) have replaced analog control systems in nuclear power plants raising cybersecurity concerns. To study and understand the cybersecurity risks of nuclear power plants both high fidelity models of the plant physics and controllers must be created, and a framework to test and evaluate cyber security events must be established. A testing and evaluation framework of cybersecurity events consists of a method of interfering with control systems, a simulation of the plant network, and a network packet capture and recording tool. Sandia National Labs (SNL) in collaboration with the University of New Mexico’s Institute for Space and Nuclear Power Studies (UNM-ISNPS) is developing such a cybersecurity testing framework.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fully self-consistent finite-temperature $GW$ in Gaussian Bloch orbitals for solids

In this work, we present algorithmic and implementation details for the fully self-consistent finite-temperature $GW$ method in Gaussian Bloch orbitals for solids. Our implementation is based on the finite-temperature Green's function formalism in which all equations are solved on the imaginary axis, without resorting to analytical continuation during the self-consistency. No quasiparticle approximation is employed and all matrix elements of the self-energy are explicitly evaluated. The method is tested by evaluating the band gaps of selected semiconductors and insulators. We show agreement with other, differently formulated, finite-temperature sc ⁢$GW$ implementations when finite-size corrections and basis-set errors are taken into account. By migrating computationally intensive calculations to graphics processing units, we obtain scalable results on large supercomputers with nearly optimal performance. Our work demonstrates the applicability of Gaussian orbital based sc⁢ $GW$ for ab initio correlated material simulations and provides a sound starting point for embedding methods built on top of $GW$.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

pnnl/solubility-prediction-paper

We are using existing deep learning modeling architectures and data representation techniques, but we are consolidating the methods into a single set of training and evaluation scripts. Additionally, we test and evaluate the performance of the models on the largest set of solubility measurements available to date.

Central, PNNL Developer↗

Time Sensitive Chemical Testing and Reduction at LANL [Slides]

Mission critical operations and other research in the past and present require the use of Time Sensitive Chemicals (TSC). TSC generate additional hazards over time and require routine testing or evaluation for safe usage and storage. in January 2023, testing and evaluation on TSC fell below 50% compliance and multiple containers required controlled destruction, leading to management action.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Laboratory and Field Arrays (ALFA)/Lab Collaboration Project (LCP) for Marine Energy (Final Scientific/Technical Report)

The objective of the Advanced Laboratory and Field Arrays (ALFA) project was to reduce the Levelized Cost of Energy (LCOE) of Marine and Hydrokinetic (MHK) energy by leveraging research, development, and testing capabilities at Oregon State University, University of Washington, and the University of Alaska, Fairbanks. ALFA is a project within the Pacific Marine Energy Center (PMEC; formerly NNMREC), a multi-institution entity with a diverse funding base that focuses on research and development for marine renewables. The ALFA project aimed to accelerate the development of next-generation arrays of wave energy conversion (WEC) and tidal energy conversion (TEC) devices through a suite of field-focused R&D activities spanning a broad range of strategic opportunity areas identified in the Funding Opportunity Announcement: • Device and/or array operation and maintenance (O&M) logistics development; • High-fidelity resource characterization and/or modeling technique development and validation; • Array-specific component technology development (e.g. moorings and foundations, transmission, and other offshore grid components); • Array performance testing and evaluation; and • Novel cost-effective environmental monitoring techniques and instrumentation testing and evaluation. The objective of the Lab Collaboration Project (LCP) was to accelerate the development of next-generation marine energy conversion systems. The LCP aimed to achieve these project objectives in collaboration with the national laboratories by: • Developing concept generation and assessment tools; • Improving access to existing testing resources; • Validating collision risk models between fish and turbines; and • Advancing analysis and simulation capabilities for wave-WEC interactions and PTO analysis in nonlinear ocean waves. The ALFA portion of the project was comprised of six overarching technical tasks: • Task 1: Debris Modeling, Detection and Mitigation; • Task 2: Autonomous Monitoring & Intervention; • Task 3: Resource Characterization for Extreme Conditions; • Task 4: Robust Models for Design of Offshore Anchoring and Mooring Systems; • Task 5: Performance Enhancement for Marine Energy Converter (MEC) Arrays; and • Task 6: Evaluating Sampling Techniques for MHK Biological Monitoring. The LCP was divided into four overarching technical tasks: • Task 7: Project Management and Reporting • Task 8: Novel Design and Assessment Methodologies for Wave Energy Converter Design (Wave- SPARC) • Task 9: Testing Access for Commercial Marine Renewable Energy Technology Developers • Task 10: Quantifying Collision Risk for Fish and Turbines • Task 11: Nonlinear Ocean Waves and PTO Control Strategy Each ALFA/LCP task listed above functioned as a separate and discreet project. A final Technical Report was written for each individual task and these reports were uploaded to OSTI, after receiving DOE approval. The following document is a compilation of each of these final, approved reports arranged as individual chapters.

13 HYDRO ENERGY↗

Demonstration Trials of AI/ML Edge+Cloud Suite (CRADA Final Report)

PACE AI and LBNL partnered under this CRADA to test and evaluate the PACE5 edge node prototype, an AI/ML edge and cloud-based suite, at FLEXLAB.The objective of the test was to evaluate the PACE5 edge node prototype's ability to perform demand shed and take to dynamic price signals, and to demonstrate advanced fault detection and microgrid monitoring capabilities.

97 MATHEMATICS AND COMPUTING↗

TEAMER: DAISY Flow-noise Testing (Abstract)

Evaluating impacts of marine energy devices is generally difficult given the dynamic environment where these devices need to be placed. The University of Washington’s (UW) DAISY (The Drifting Acoustic Instrumentation SYstem) is designed to measure radiated noise around marine energy converters operating in energetic waves and currents. In currents, a primary limitation for measurement fidelity at low frequencies (< 100 Hz) is the potential for non-propagating “flow-noise” to mask propagating sound and inflate estimates of the radiated noise from marine energy converters at frequencies that overlap with hearing sensitivities of fish and some marine mammals. While free-drifting measurements help to minimize the relative velocity that produces flow-noise, significant levels were still observed during initial DAISY tests. This motivated the development of a fabric “flow shield” around the hydrophone that disrupts both flow-noise generation mechanisms proposed by the initial tests. First, the flow shield is a source of substantial drag which keeps the hydrophone package moving with the approximate velocity of the surrounding water, compensating for differential wind or current forcing on the surface expression. By minimizing relative velocity around the hydrophone, turbulence shed by the hydrophone is also minimized. Second, the flow shield creates a largely quiescent pocket around the hydrophone, minimizing advection of free stream turbulence over the hydrophone element. Field data collected in these experiments will test effectiveness of these flow shields and provide quantitative data use and deployment.

16 TIDAL AND WAVE POWER↗