Search NASA⌕ Search

SEARCH · Search NASA

Results for “therapy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Enhanced animal growth via ligand-regulated GHRH myogenic-injectable vectors

Regulated animal growth occurred following a single electroporated injection of a mixture of two plasmids (10 microg of DNA), one expressing the GeneSwitch regulator protein, the other an inducible growth hormone releasing hormone (GHRH) gene, into the tibialis anterior muscles of adult SCID mice. Administration of the ligand mifepristone (MFP) up-regulated GHRH expression, as shown by elevations of IGF-I levels, and when MFP dosing was withdrawn, IGF-I returned to baseline levels. Five cycles of IGF-I induction were observed during a five-month period. Chronic MFP dosing for 25 days increased lean body mass, weight gain, and bone mineral density significantly compared with non-MFP treated controls. In summary, long-term drug-regulated GHRH expression was achieved following plasmid-based gene therapy, and chronic induction of GHRH expression in adult animals led to improvements in weight gain and body composition.

NASA Discipline Musculoskeletal↗

Synthetic muscle promoters: activities exceeding naturally occurring regulatory sequences

Relatively low levels of expression from naturally occurring promoters have limited the use of muscle as a gene therapy target. Myogenic restricted gene promoters display complex organization usually involving combinations of several myogenic regulatory elements. By random assembly of E-box, MEF-2, TEF-1, and SRE sites into synthetic promoter recombinant libraries, and screening of hundreds of individual clones for transcriptional activity in vitro and in vivo, several artificial promoters were isolated whose transcriptional potencies greatly exceed those of natural myogenic and viral gene promoters.

Non-NASA Center↗

Management of hypophosphatemia

The etiology, clinical presentation, and management of hypophosphatemia are reviewed. Phosphorus is a major intracellular anion and plays an important role in many biochemical pathways relating to normal physiologic functions. Approximately 60 to 90% of the 1 to 1.5 g of daily dietary phosphorus intake is absorbed, and of that amount, about two thirds is excreted in the urine. The overall incidence of hypophosphatemia is about 2 to 3% of all hospitalized patients. Factors associated with hypophosphatemia include phosphate-binding antacid therapy, nasogastric suction, liver disease, sepsis, alcoholism, and acidosis associated with diabetic ketoacidosis. Patients receiving parenteral nutrient solutions were also at higher risk for hypophosphatemia before the routine supplementation of these formulations with phosphate. Patients with hypophosphatemia may be asymptomatic or may experience weakness, malaise, anorexia, bone pain, and respiratory arrest. The major systems involved include the neuromuscular, hematologic, and skeletal systems. Phosphorus-containing products used to treat hypophosphatemia are a combination of monobasic and dibasic phosphate salts. Therefore, it is essential to calculate doses in millimoles rather than milligrams or milliequivalents to more accurately reflect the phosphorus concentration and to avoid potentially serious dosage errors. Normal daily requirements are readily maintained by dietary sources of phosphorus such as milk products or may be supplemented by phosphate-containing products administered orally or intravenously. Since phosphorus is a key factor in many organ systems, it is essential to monitor serum phosphorus concentrations in patients at risk for hypophosphatemia.

Review, Tutorial↗

Team Update on North American Proton Facilities for Radiation Testing

In the wake of the closure of the Indiana University Cyclotron Facility (IUCF), this presentation provides an overview of the options for North American proton facilities. This includes those in use by the aerospace community as well as new additions from the cancer therapy regime. In addition, proton single event testing background is provided for understanding the criteria needed for these facilities for electronics testing.

Single event effects testing↗

Team Update on North American Proton Facilities for Radiation Testing

In the wake of the closure of the Indiana University Cyclotron Facility (IUCF), this presentation provides an overview of the options for North American proton facilities. This includes those in use by the aerospace community as well as new additions from the cancer therapy regime. In addition, proton single event testing background is provided for understanding the criteria needed for these facilities for electronics testing.

Proton cyclotrons↗

Team Update on North American Proton Facilities for Radiation Testing

In the wake of the closure of the Indiana University Cyclotron Facility (IUCF), this presentation provides an overview of the options for North American proton facilities. This includes those in use by the aerospace community as well as new additions from the cancer therapy regime. In addition, proton single event testing background is provided for understanding the criteria needed for these facilities for electronics testing.

Single event effects testing↗

Team Update on North American Proton Facilities for Radiation Testing

In the wake of the closure of the Indiana University Cyclotron Facility (IUCF), this presentation provides an overview of the options for North American proton facilities. This includes those in use by the aerospace community as well as new additions from the cancer therapy regime. In addition, proton single event testing background is provided for understanding the criteria needed for these facilities for electronics testing.

Cancer therapy↗

Simulator effects partial gravity conditions

Adjustable apparatus which simulates partial to zero gravity partially supports the weight of convalescing patients in rehabilitation exercises. This device is an ideal tool for physical therapy.

Johnson, H. I.↗

Zero-g simulation system for therapeutic application

System aids in therapeutic retraining of damaged muscles or functions as walking support during therapy. Articulated harness assembly contains patient, suspension system supports harness assembly in such a way as to counterbalance exertion of external forces on patient.

Dane, D. H.↗

New reaction tester accurate within 56 microseconds

Testing device measures simple and disjunctive reaction time of human subject to light stimuli. Tester consists of reaction key, logic card, panel mounted neon indicators, and interconnecting wiring. Device is used for determining reaction times of patients undergoing postoperative neurological therapy.

Brown, H.↗

Nitrogen fixation studies, lead detection in living plants, and solar wind analysis

Progress is reported for research on the following: (1) magnetically shielded test facility studies; (2) electrochemistry of B10C2H12, B9CH10(-), and preparation of tumor specific boron containing materials for use in cancer therapy; (3) histochemical method for determining lead in living plant tissue; (4) diamond cementing; (5) analysis of solar wind using the washings of lunar fines; and (6) environmental engineering.

Libby, W. F.↗

Nuclear Science Symposium, 19th, and Nuclear Power Systems Symposium, 4th, Miami, Fla., December 6-8, 1972, Proceedings.

Major topics covered include radiation monitoring instrumentation, nuclear circuits and systems, biomedical applications of nuclear radiation in diagnosis and therapy, plasma research for fusion power, reactor control and instrumentation, nuclear power standards, and applications of digital computers in nuclear power plants. Systems and devices for space applications are described, including the Apollo alpha spectrometer, a position sensitive detection system for UV and X-ray photons, a 4500-volt electron multiplier bias supply for satellite use, spark chamber systems, proportional counters, and other devices. Individual items are announced in this issue.

Source record↗

New urea-absorbing polymers for artificial kidney machines

Etherified polymer is made from modified cellulose derivative which is reacted with periodate. It will absorb 2 grams of urea per 100 grams of polymer. Indications are that polymers could be used to help remove uremic wastes in artificial kidneys, or they could be administered orally as therapy for uremia.

Mueller, W. A.↗