Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermalize”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Thermal Storage Performance of a Dual-Purpose Underground Thermal Battery for Shaping the Electric Demand of Buildings

A dual-purpose underground thermal battery (DPUTB) integrates a ground heat exchanger with underground thermal energy storage. It can be installed in shallow boreholes (less than 6 m deep) and thus is less expensive than the conventional ground heat exchangers. The thermal energy storage can be used to shave or shift the electric load for meeting the thermal demands of a building. The charging and discharging performance of a lab-scale DPUTB were tested. The test results show that the DPUTB can be fully charged within 4 h and can provide 34 W cooling continuously for 2.5 h with a supply water temperature below 14°C. A small amount of phase-change material significantly increased the thermal storage capacity.

Wang, Lingshi↗

Thermal energy storage apparatus, controllers and thermal energy storage control methods

Thermal energy storage apparatus, controllers and thermal energy storage control methods are described. According to one aspect, a thermal energy storage apparatus controller includes processing circuitry configured to access first information which is indicative of surpluses and deficiencies of electrical energy upon an electrical power system at a plurality of moments in time, access second information which is indicative of temperature of a thermal energy storage medium at a plurality of moments in time, and use the first and second information to control an amount of electrical energy which is utilized by a heating element to heat the thermal energy storage medium at a plurality of moments in time.

Hammerstrom, Donald J.↗

Low-Carbon District Heating: Performance Modeling of Hybrid Solar, Heat Pump, and Thermal Storage Systems for District Thermal Energy in the United States

District heating requires thermal energy in the temperature range of 40 degrees C - 120 degrees C. Typically, the thermal energy input for these systems has largely been met through fossil energy. However, the temperature range is low enough that it presents an opportunity for low-carbon technologies such as solar thermal and electrified thermal generators like heat pumps to decarbonize the heat generation. In this paper, a heat pump model was applied to estimate the performance and economics of a real-world low-carbon district heating substation. This system is comprised of a flat plate solar collector field paired with a mechanical vapor compression heat pump and hot water thermal storage, augmented by gas-fired boilers. Plant data was used to tune the model and estimate the system's benefits in terms of both standard financial metrics (IRR and payback), and environmental metrics, including avoided CO2 emissions. The model is subsequently employed to estimate the technical and economic potential of solar + heat pump + ther-mal storage hybrid systems as retrofits for district heating systems in eight US Markets.

district heating↗

Energy burden aware and thermal resilience informed thermal energy storage system planning for disadvantaged communities

Disadvantaged communities often face a disproportionate energy burden because they need to allocate a higher percentage of their income to energy costs. More importantly, climate change-induced extreme weather events, such as heat waves and severe cold snaps, exacerbate these communities’ energy burdens. As a result, low- and medium-income communities are more likely to experience energy supply disruptions, increased health risks, and elevated energy bills because of inadequate thermal insulation and airtightness in their houses. Thermal energy storage (TES) systems, such as large-scale (community-level) geothermal energy storage and small-scale (building-level) phase change material (PCM)–based storage, have a great potential to improve building energy efficiency and to enhance thermal comfort, load shifting, and integration with renewable energy. The objective of this study is to optimally allocate building level PCM-based TES systems at the community level by considering energy equity and extreme weather effects. To this end, we developed an energy burden and thermal resilience–informed TES system planning framework, which includes three modules: (1) a community-level energy burden and thermal resilience assessment module, (2) building-level a TES system integration and assessment module, and (3) a community-level optimal planning module. Case studies were conducted on four disadvantaged communities in Montgomery and Shelby Counties in Tennessee with energy burdens >10% and with high percentages of people of color. The results indicate that this comprehensive planning framework can assist disadvantaged communities in reducing their energy burden and in bolstering their resilience against the adverse effects of climate change.

Shen, Zhenglai↗

Tracking the Influence of Thermal Expansion and Oxygen Vacancies on the Thermal Stability of Ni-Rich Layered Cathode Materials

The ever-growing demand for high-energy lithium-ion batteries in portable electronics and electric vehicles has triggered intensive research efforts over the past decade. An efficient strategy to boost the energy and power density of lithium-ion batteries is to increase the Ni content in the cathode materials. However, a higher Ni content in the cathode materials gives rise to safety issues. Herein, thermal expansion and oxygen vacancies are proposed as new critical factors that affect the thermal stability of charged Ni-rich cathode materials based on a systematic synchrotron-based X-ray study of Li 0.33 Ni 0.5+x Co 0.2 Mn 0.3-x O 2 (x = 0, 0.1, 0.2) cathode materials during a heating process. Charged cathode materials with higher Ni contents show larger thermal expansion, which accelerates transition metal migration to the Li layers. Oxygen vacancies are formed and accumulate mainly around Ni ions until the layered-to-spinel phase transition begins. The oxygen vacancies also facilitate transition metal migration to the Li layers. Thermal expansion and the presence of oxygen vacancies decrease the energy barrier for cation migration and facilitate the phase transitions in charged cathode materials during the heating process. These results provide valuable guidance for developing new cathode materials with improved safety characteristics.

25 ENERGY STORAGE↗

Experimental investigation on phase change material–based finned tube heat exchanger for thermal energy storage and building envelope thermal management

Phase change materials (PCMs) are attractive solutions for thermal energy storage (TES) applications by absorbing and releasing large amounts of latent heat during solid–liquid phase transitions. However, their relatively low thermal conductivity requires novel heat exchanger–based solutions to improve the power density and overall energy storage efficiency of the TES system. This work presents the design and experimental results of a finned tube heat exchanger to store collected natural thermal energy from a building envelope in a latent-based TES and to release it later for building heating/cooling applications. We experimentally evaluate the finned tube heat exchanger and evaluate the performance of TES in reducing building heating and cooling loads over 3–4 h of desired time of operation (e.g., peak load). The optimized design allows for maximum energy density by minimizing the heat exchanger volume, and the system is evaluated experimentally using commercially available heat exchanger materials and an organic PCM. Here, the experimental results reveal that the TES system is able to charge and discharge stored latent energy within 3–4 h, matching peak building electricity demand duration under an average fluid flow rate of 0.136 kg/s and temperature difference of 5.55 °C. Importantly, such optimized designs illuminate a path toward TES designs that are low-cost, scalable, and optimized for thermal energy and power availability under the desired time of operation.

25 ENERGY STORAGE↗

A Demonstration System for Geological Thermal Energy Storage of Concentrating Solar Thermal

Energy storage is increasingly necessary as variable energy technologies are deployed. Seasonal energy storage can shift energy generation from the summer to the winter, but these technologies must have extremely large energy capacities and low costs. Geological Thermal Energy Storage (GeoTES) is proposed as a solution for long-term energy storage [1]. Excess thermal energy can be stored in permeable reservoirs such as aquifers and depleted hydrocarbon reservoirs for several months. The energy capacity cost of GeoTES is very low which makes it suitable for both daily- and seasonal storage of Concentrating Solar Thermal (CST) energy, thus enabling CST to provide value to electricity markets and thermal energy off-takers. A CST-GeoTES demonstration system has been funded by the U.S. Department of Energy, Solar Energy Technology Office. In this article, we will describe this demonstration system and progress that has been made in its development. The demonstration system will comprise a 2 MWth parabolic trough with an 8m aperture developed by Gossamer Space Frames, seven wells, and a 100 kWe power cycle. The demonstration system will be deployed in Kern County, California by Premier Resource Management. A techno-economic model for CST-GeoTES systems has also been developed [3] and is applied to the demonstration system and its planned future expansion. The model integrates the output of specialist models of each subsystem, which enables the performance and cost of both the subsurface and surface systems to be captured. Off-design models enable the performance to be evaluated at each hour of the year, before being aggregated to evaluate the economic potential of CST-GeoTES. Initial analysis indicates that CST-GeoTES can provide long duration energy storage capabilities with low marginal costs of energy capacity - leading to a low value of Levelized Cost of Storage (LCOS) compared to alternative technologies, see Figure 2. In this article, we investigate the cost and performance of the specific demonstration site being developed by PRM and explore a range of operational profiles that can deliver different value streams, such as daily and seasonal storage, capacity, and resiliancy.

14 SOLAR ENERGY↗

Hydrophobic Lightweight Cement with Thermal Shock Resistance and Thermal Insulating Properties for Energy-Storage Geothermal Well Systems

This study assessed the possibility of using polymethylhydrosiloxane (PMHS)-treated fly ash cenospheres (FCS) for formulating a thermally insulating and thermal shock (TS)-resistant cementitious blend with calcium aluminate cement. To prevent FCS degradation in an alkaline cement environment at high temperatures, the cenospheres were pre-treated with sodium metasilicate to form silanol and aluminol groups on their surface. These groups participated in a dehydrogenation reaction with the functional ≡Si–H groups within PMHS with the formation of siloxane oxygen-linked M-FCS (M: Al or Si). At high hydrothermal temperatures of 175 and 250 °C, some Si–O–Si and SiCH 3 bonds ruptured, causing depolymerization of the polymer at the FCS surface and hydroxylation of the raptured sites with the formation of silanol groups. Repolymerization through self-condensation between the silanol groups followed, resulting in the transformation of siloxane to low crosslinked silicon-like polymer as a repolymerization-induced product (RIP) without carbon. The RIP provided adequate protection of FCS from pozzolanic reactions (PR), which was confirmed by the decline in zeolites as the products of PR of FCS. Cements with PMHS-treated FCS withstood both hydrothermal and thermal temperature of 250 °C in TS tests, and they also showed improved compressive strength, toughness, and water repellency as well as decreased thermal conductivity. The lubricating properties of PMHS increased the fluidity of lightweight slurries.

15 GEOTHERMAL ENERGY↗

Thermal Properties of the Very Low Thermal Conductivity Ternary Chalcogenide Cu 4 Bi 4 M 9 (M = S, Se)

Temperature-dependent thermal properties of phase-pure polycrystalline ternary chalcogenides Cu 4 Bi 4 S 9 and Cu 4 Bi 4 Se 9 are reported. The structure and bonding in these materials result in very low thermal conductivity values (<0.8 W m -1 K -1 at room temperature) for both materials. The lattice contribution, Debye temperatures, and Sommerfeld coefficient are obtained from low-temperature heat capacity data that also indicate very small electronic contributions to the heat capacity for these materials. This study aids in the identification of new nontoxic, earth-abundant resistive ternary chalcogenide materials with low thermal conductivity for potential thermal barrier coating and rewriteable storage applications.

36 MATERIALS SCIENCE↗

Precipitation-site competition in duplex stainless steels: Cu clusters vs spinodal decomposition interfaces as nucleation sites during thermal aging

Competing microstructural evolution mechanisms can exist simultaneously when duplex stainless steels are operating for several decades in a high temperature service environment. Such competition between different microstructural evolution pathways can be difficult to ascertain using simple model alloy systems necessitating detailed structural and compositional analysis of phase transformation mechanisms in complex alloys Thus, in this study duplex stainless steels with complex but well understood chemistries were used to investigate the relative importance of different heterogeneous nucleation sites – specifically spinodal decomposition and Cu clustering – on precipitation of Ni-Si-Mn particles during long term thermal aging. Precipitation of Ni-Si-Mn particles in duplex stainless steels and ferritic steels during thermal aging and irradiation is known to have profound effect on mechanical properties. Using duplex stainless steels with custom modified compositions along with atom probe tomography characterization and first-passage kinetic Monte Carlo (FPKMC) simulations it is revealed that while the interface between Cr and Fe formed during spinodal decomposition can be a pathway for diffusion of Ni, Si, Mn, and Cu, it is not a site that encourages precipitation of Ni-Si-Mn rich particles. Instead, the presence of a higher concentration of Cu in these steels leads to formation of small Cu clusters with high energy interfaces that act as nucleation sites for Ni-Si-Mn particles because of its strong interaction particularly with Ni increasing the chemical driving force for precipitation. These results will help inform predictive models for the use of duplex stainless steels and other precipitation-hardened alloys for extended operation at high temperatures.

Duplex stainless steel, Thermal aging, Precipitati↗

Damage development in neutron-irradiated concrete in a test reactor: Hygro-thermal and mechanical simulations

This paper reports the development of a 3D mesoscale hygro-thermal-mechanical simulation approach to predict damage in concrete irradiated in a test reactor. This framework, developed in MOOSE, considers the effects of elevated temperature, moisture content, and high neutron fluence (energy threshold, E > 0.1 MeV) on the mortar and aggregates separately. The first-stage simulation implements hygro-thermal analysis to determine the temperature and RH inside the specimen as a function of imposed radiation energy. These are used as inputs to the second stage, which considers radiation-induced volumetric expansion (RIVE) of aggregates, and creep, shrinkage, and stress-strain response of mortar to predict the expansion, stresses, and damage in specimens made using different coarse aggregates and subjected to different irradiation times. The irradiation time-dependent damage in the mortar is expressed using an isotropic damage parameter. This multi-physics model serves as a predictive tool for damage quantification in concrete due to neutron irradiation.

36 MATERIALS SCIENCE↗

A conceptual model for how to design for building envelope characteristics. Impact of thermal comfort intervals and thermal mass on commercial buildings in U.S. climates

The paper presents a simplified conceptual model for energy demand calculations based on building envelope characteristics, thermal mass and local climate. It is based on a network model and lumped analysis of the dynamic process. Characteristic parameters for the buildings are suggested; Driving temperature (DT), Driving temperature difference, (DTD), External Load Temperature (ELT), and Thermal Load Resistance (TLR). The Building Envelope Performance ( BEP 0 ), based on a controlled constant indoor temperature is introduced. Solution techniques using stable explicit forward differences based on analytical solutions are derived. The conceptual model has been used for mapping the Driving temperature difference and introduced two performance factors and . The first factor represents the effect of thermal comfort interval and thermal mass on the energy demand. The latter represents the ratio between cooling and heating energy demand. These three parameters and factors have been visualized on U.S. maps and enable a possibility to communicate the demand of energy, and cooling and the coupling to building characteristics, in a concise way.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooling Design and Thermal Analysis for Thermal Shields of a Cryocooler-Cooled Superconducting ECR Ion Source MARS-D Magnet

Here, a demonstrative NbTi based Mixed Axial and Radial field System (MARS-D) is being developed for a next-Generation Electron Cyclotron Resonance Ion Source (ECRIS) at Lawrence Berkeley National Laboratory (LBL), which employs a novel closed-loop coil design scheme that more efficiently utilizes conductor fields and extend the application of NbTi for high frequency (up to 45 GHz) ECR operation. The NbTi MARS-D magnet consists of a single hexagonally shaped closed-loop coil and a set of auxiliary solenoids. A cryostat for cooling the MARS-D magnet is under design at LBL. The MARS-D magnet working around 4.2 K will be bath-cooled in liquid helium using multiple two-stage cryocoolers. An intermediate temperature thermal radiation shield is adopted to reduce the heat leakage imposed on 4.2 K coil cold mass from room temperature. The thermal shield is conduction-cooled by the first-stage cold heads of four two-stage cryocoolers and the cold head of a single-stage cryocooler shared with nine binary leads. The temperature in the area of the shield that warm ends of HTS leads are mounted on is expected no higher than 60 K, which is limited by maximum allowable working temperature of HTS leads. The paper presents thermal analysis on the thermal radiation shield including heat loads and effects of eddy current induced during quench on its material selection.

ECRIS↗

Data Testing of Polyethylene Thermal Scattering Law with New Thermal Epithermal eXperiments (TEX) Plutonium Baseline Benchmark, PU-MET-MIXED-002

Five plutonium baseline experiments completed in September of 2018 from the Thermal Epithermal eXperiments (TEX) program have been accepted by the International Criticality Safety Benchmark Evaluation Project as PU-MET-MIXED-002 and will be included in the 2020 version of the handbook. The experiments were made up of stacked layers of plutonium Zero Power Physics Reactor (ZPPR) plates moderated by polyethylene (PE, chemical formula C2H4) to varying degrees to create configurations with five different neutron spectra, including one fast configuration, one thermal configuration, and three mixed configurations. Calculations of the benchmark show overprediction of k eff when using the most recent release of the Evaluated Nuclear Data File Version B (ENDF/B) library release (VIII.0) cross sections, particularly when compared to the previous ENDF/B-VII.1 results. One potential source of overprediction was hypothesized to be the new Molecular Dynamics (MD) generated PE Thermal Scattering Law (TSL). The overprediction was shown via calculation to not be caused by the new ENDF/B-VIII.0 thermal scattering law, and in fact the overprediction was mitigated by the new PE TSL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal Process Intensification: Transforming the Way Industry Uses Thermal Process Energy

The US Department of Energy’s (DOE’s) Advanced Manufacturing Office held the virtual workshop entitled “Thermal Process Intensification: Transforming the Way Industry Uses Thermal Process Energy” in November and December 2020. The workshop brought together participants from universities/laboratories, industries, equipment manufacturers, technology vendors, nongovernmental organizations, and subject-matter experts to discuss transformative technologies and strategies to substantially improve the performance (e.g., energy productivity, thermal efficiency, reduced greenhouse gas [GHG] emissions, reduced number of process steps) of thermal processing systems in the industrial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Steady-State System Package for Nuclear Thermal Propulsion Analysis Using Multi-Dimensional Thermal Hydraulics and Dimensionless Turbopump Treatment

Nuclear thermal propulsion is an evolving technology that can be utilized for long-distance space travel. This technology yields the advantage of a high thrust and specific impulse, but requires an examination of the potential design adjustments necessary to enhance its feasibility. The development of nuclear thermal propulsion requires a comprehensive understanding of the system-level behavior during transient and steady-state operation. This paper extends our previous research by including the proper handling of turbomachinery with multi-channel thermal hydraulic simulations only for steady-state solutions. The system-level approach presented here enables the treatment of the turbopump components through non-dimensional analysis that eliminates the assumption of constant efficiencies. All the other components within the system (e.g., reflector and core) can be discretized to multiple channels and layers, in which the full thermal hydraulic solution is established. The approach chosen here enables the realistic modeling of the propellant flow within the expander cycle by capturing the pressure losses, mass flow rate splits, and enthalpy gain for various operational conditions. The verification of the package is completed through point comparisons of previous investigations into similar system designs. Furthermore, sensitivity studies are used to benchmark the capabilities of the package and investigate solution variations due to the perturbation of operational conditions and regimes. The sensitivity studies performed here are important to capture variation in flow characteristics (e.g., temperature, pressure, mass flow rates) for different design objectives such as the thrust and specific impulse. This work demonstrates that system-level simulations lacking multi-channel capability and proper turbomachinery treatment may yield higher uncertainties in understanding the engine’s response and characteristics to changing various requirements. This is extremely important when screening the design space of such propulsion systems and when transient simulations are required.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗