Search NASA⌕ Search

SEARCH · Search NASA

Results for “time of flight”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Effects of exposure time during flight maneuvers on passenger subjective comfort rating

The effects were investigated of length of exposure time to a flight maneuver environment on subjective passenger evaluation of ride comfort. Four statistical analysis tests were performed on ride comfort ratings obtained during one two-hour test flight wherein eleven test subjects were exposed to two identical programmed sequences of twenty four flight segments which covered a wide range of maneuver conditions. The results of the analysis indicate that, for over ninety five percent of the segments, there is no significant change in the test subjects comfort ratings of identical segments spaced one hour apart. These results are in contrast to those found in previous studies involving a vibration environment, rather than flight maneuver environment, where increased exposure-time was found to cause a degradation of ride comfort ratings.

Brown, V. J.↗

Configuration management issues and objectives for a real-time research flight test support facility

An account is given of configuration management activities for the Western Aeronautical Test Range (WATR) at NASA-Ames, whose primary function is the conduct of aeronautical research flight testing through real-time processing and display, tracking, and communications systems. The processing of WATR configuration change requests for specific research flight test projects must be conducted in such a way as to refrain from compromising the reliability of WATR support to all project users. Configuration management's scope ranges from mission planning to operations monitoring and performance trend analysis.

Yergensen, Stephen↗

Effect of electron beam pulse width on time-of-flight spectra

A simple but useful formula describing the effect of electron gun pulse width on the time of flight (TOF) spectra measured in translational spectroscopy experiments is developed. An approximately monoenergetic pulsed electrostatically focused electron beam traverses a scattering cell filled with a Maxwellian gas. Inelastic electron collisions with the gas produce metastable particles, ions, scattered electrons, and photons which then pass through a collimating slit system at right angles to the electron beam. TOF techniques are used to separate the photon signal from the metastable particle signal and to measure the TOF distribution of the metastable species.

Misakian, M.↗

Configuration management issues and objectives for a real-time research flight test support facility

Presented are some of the critical issues and objectives pertaining to configuration management for the NASA Western Aeronautical Test Range (WATR) of Ames Research Center. The primary mission of the WATR is to provide a capability for the conduct of aeronautical research flight test through real-time processing and display, tracking, and communications systems. In providing this capability, the WATR must maintain and enforce a configuration management plan which is independent of, but complimentary to, various research flight test project configuration management systems. A primary WATR objective is the continued development of generic research flight test project support capability, wherein the reliability of WATR support provided to all project users is a constant priority. Therefore, the processing of configuration change requests for specific research flight test project requirements must be evaluated within a perspective that maintains this primary objective.

Yergensen, Stephen↗

Miniature Time-of-Flight Mass Spectrometer

Major advances must occur to protect astronauts from prolonged periods in near-zero gravity and high radiation associated with extended space travel. The dangers of living in space must be thoroughly understood and methods developed to reverse those effects that cannot be avoided. Six of the seven research teams established by the National Space Biomedical Research Institute (NSBRI) are studying biomedical factors for prolonged space travel to deliver effective countermeasures. To develop effective countermeasures, each of these teams require identification of and quantitation of complex pharmacological, hormonal, and growth factor compounds (biomarkers) in humans and in experimental animals to develop an in-depth knowledge of the physiological changes associated with space travel. At present, identification of each biomarker requires a separate protocol. Many of these procedures are complicated and the identification of each biomarker requires a separate protocol and associated laboratory equipment. To carry all of this equipment and chemicals on a spacecraft would require a complex clinical laboratory; and it would occupy much of the astronauts time. What is needed is a small, efficient, broadband medical diagnostic instrument to rapidly identify important biomarkers for human space exploration. The Miniature Time-Of- Flight Mass Spectrometer Project in the Technology Development Team is developing a small, high resolution, time-of-flight mass spectrometer (TOFMS) to quantitatively measure biomarkers for human space exploration. Virtues of the JHU/APL TOFMS technologies reside in the promise for a small (less than one cubic ft), lightweight (less than 5 kg), low-power (less than 50 watts), rugged device that can be used continuously with advanced signal processing diagnostics. To date, the JHU/APL program has demonstrated mass capability from under 100 to beyond 10,000 atomic mass units (amu) in a very small, low power prototype for biological analysis. Further, the electronic nature of the TOFMS output makes it ideal for rapid telemetry to earth for in-depth analysis by ground support teams.

Potember, Richard S.↗

Improved time-of-flight mass spectrometer

External signal-conditioning electronics assembled from commercially available components improves dynamic capability of time-of-flight mass spectrometer.

Lincoln, K. A.↗

Synopsis of a computer program designed to interface a personal computer with the fast data acquisition system of a time-of-flight mass spectrometer

Briefly described are the essential features of a computer program designed to interface a personal computer with the fast, digital data acquisition system of a time-of-flight mass spectrometer. The instrumentation was developed to provide a time-resolved analysis of individual vapor pulses produced by the incidence of a pulsed laser beam on an ablative material. The high repetition rate spectrometer coupled to a fast transient recorder captures complete mass spectra every 20 to 35 microsecs, thereby providing the time resolution needed for the study of this sort of transient event. The program enables the computer to record the large amount of data generated by the system in short time intervals, and it provides the operator the immediate option of presenting the spectral data in several different formats. Furthermore, the system does this with a high degree of automation, including the tasks of mass labeling the spectra and logging pertinent instrumental parameters.

Bechtel, R. D.↗

New high-resolution electrostatic ion mass analyzer using time of flight

The design of a high-resolution ion-mass analyzer is described, which is based on an accurate measurement of the time of flight (TOF) of ions within a region configured to produce a harmonic potential. In this device, the TOF, which is independent of ion energy, is determined from a start pulse from secondary electrons produced when the ion passes through a thin carbon foil at the entrance of the TOF region and at a stop pulse from the ion striking a microchannel plate upon exciting the region. A laboratory prototype instrument called 'VMASS' was built and was tested at the Goddard Space Flight Center electrostatic accelerator, showing a good mass resolution of the instrument. Sensors of the VMASS type will form part of the WIND Solar Wind and Suprathermal Ion experiment, the Soho mission, and the Advanced Composition Explorer.

Hamilton, D. C.↗

A fast data acquisition system for the study of transient events by high repetition rate time-of-flight mass spectrometry

Recent advances in commercially available data acquisition electronics embodying high speed A/D conversion coupled to increased memory storage have now made practical (at least within time intervals of a third of a millisecond or more) the capturing of all of the data generated by a high repetition rate time-of-flight mass spectrometer producing complete spectra every 25 to 35 microseconds. Such a system was assembled and interfaced with a personal computer for control and management of data. The applications are described for recording time-resolved spectra of individual vapor plumes induced from the pulsed-laser heating of material. Each laser pulse triggers the system to generate automatically a 3-dimensional (3-D) presentation of the time-resolved spectra with m/z labeling of the major mass peaks, plus an intensity versus time display of both the laser pulse and the resulting vapor pulse. The software also permits storing of data and its presentation in various additional forms.

Lincoln, K. A.↗

Trajectories for Flyby Sample Return at Saturn's Moons

Ballistic trajectories are computed which would enable a sample return mission to Titan or Enceladus without capturing, descending, or landing. The low-cost mission concept utilizes a free return trajectory that also involves a close flyby of the moon. This work extends the concept, and related trajectory analysis methodology, previously applied to a Europa mission. Specifically, a broad search algorithm is employed to systematically locate potentially feasible itineraries over an entire Saturn period. High-quality approximate solutions are then optimized to be continuous using high-fidelity dynamics. Techniques and software from the Europa analysis, were readily adapted and able to find numerous mission enabling trajectories. A direct mission to Titan is possible with flight time under 16 years and Earth-relative speeds below 11.0 km/sec. The VEEGA option is shown to substantially reduce launch C3, but flight times exceed 21 years. Unfortunately, an Enceladus mission requires a flight time of 25 years or more, and incurs fairly high relative speeds. Nevertheless, an optimized reference mission is computed.

Jones, Drew Ryan↗

Guidance concepts for time-based flight operations

Airport congestion and the associated delays are severe in today's airspace system and are expected to increase. NASA and the FAA is investigating various methods of alleviating this problem through new technology and operational procedures. One concept for improving airspace productivity is time-based control of aircraft. Research to date has focused primarily on the development of time-based flight management systems and Air Traffic Control operational procedures. Flight operations may, however, require special onboard guidance in order to satisfy the Air Traffic Control imposed time constraints. The results are presented of a simulation study aimed at evaluating several time-based guidance concepts in terms of tracking performance, pilot workload, and subjective preference. The guidance concepts tested varied in complexity from simple digital time-error feedback to an advanced time-referenced-energy guidance scheme.

Vicroy, Dan D.↗

Theory and operation of a three-gate time-of-flight velocity analyzer

Theoretical considerations and test results are presented for a new-type velocity analyzer for incident fast neutral particles, positive ions, and negative ions. Velocity analysis is carried out by means of a pulsed, three-gate time-of-flight (TOF) technique capable of eliminating alias velocities (harmonics) to sixth order. In addition the design and operation are presented of a four-element ion lens system, with small spherical and chromatic aberrations, suitable for interfacing a large-diameter ion beam from the TOF section with a subsequent mass analyzer.

Martus, K. E.↗

Characterization of a Carbon Nanotube Field Emission Electron Gun for the VAPoR Miniaturized Pyrolysis-Time-of-Flight Mass Spectrometer

We are developing the VAPoR (Volatile Analysis by Pyrolysis of Regolith) instrument towards studying soil composition, volatiles, and trapped noble gases in the polar regions of the Moon. VAPOR will ingest a soil sample and conduct analysis by pyrolysis and time-of-flight mass spectrometry (ToF-MS). Here, we describe miniaturization efforts within this development, including a carbon nanotube (CNT) field emission electron gun that is under consideration for use as the electron impact ionization source for the ToF-MS.

Getty, Stephanie↗

Exploring Transfers Between Earth-Moon Halo Orbits via Multi-Objective Reinforcement Learning

Multi-Reward Proximal Policy Optimization, a multi-objective deep reinforcement learning algorithm, is used to examine the design space of low-thrust trajectories for a SmallSat transferring between two libration point orbits in the Earth-Moon system. Using Multi-Reward Proximal Policy Optimization, multiple policies are simultaneously and efficiently trained on three distinct trajectory design scenarios. Each policy is trained to create a unique control scheme based on the trajectory design scenario and assigned reward function: a unique combination of weights scaling competing objectives that guide the spacecraft to the target mission orbit, incentivize faster flight times, and penalize propellant mass usage. Then, the policies are evaluated on the same set of perturbed initial conditions in each scenario to generate the propellant mass usages, flight times, and state discontinuities from a reference trajectory for each control scheme. This solution space of low-thrust trajectories for a SmallSat is used to examine the multi-objective trade space for the trajectory design scenario. By autonomously constructing the solution space, insights into the required propellant mass, flight time, and transfer geometry are rapidly achieved.

Christopher J Sullivan↗

Exploring Transfers Between Earth-Moon Halo Orbits via Multi-Objective Reinforcement Learning

Multi-Reward Proximal Policy Optimization, a multi-objective deep reinforcement learning algorithm, is used to examine the design space of low-thrust trajectories for a SmallSat transferring between two libration point orbits in the Earth- Moon system. Using Multi-Reward Proximal Policy Optimiza- tion, multiple policies are simultaneously and efficiently trained on three distinct trajectory design scenarios. Each policy is trained to create a unique control scheme based on the trajectory design scenario and assigned reward function: a unique combination of weights scaling competing objectives that guide the spacecraft to the target mission orbit, incentivize faster flight times, and penalize propellant mass usage. Then, the policies are evaluated on the same set of perturbed initial conditions in each scenario to generate the propellant mass usages, flight times, and state discontinuities from a reference trajectory for each control scheme. This solution space of low-thrust trajectories for a SmallSat is used to examine the multi-objective trade space for the trajectory design scenario. By autonomously constructing the solution space, insights into the required propellant mass, flight time, and transfer geometry are rapidly achieved.

Mashiku, Alinda K.↗

Development of a Robust, High Current, Low Power Field Emission Electron Gun for a Spaceflight Reflectron Time-of-Flight Mass Spectrometer

Carbon materials, including carbon nanotubes (CNTs) and nitrogen-incorporated ultrananocrystalline diamond (N-UNCD), have been of considerable interest for field emission applications for over a decade. In particular, robust field emission materials are compelling for space applications due to the low power consumption and potential for miniaturization. A reflectron time-of-flight mass spectrometer (TOF-MS) under development for in situ measurements on the Moon and other Solar System bodies uses a field emitter to generate ions from gaseous samples, using electron ionization. For these unusual environments, robustness, reliability, and long life are of paramount importance, and to this end, we have explored the field emission properties and lifetime of carbon nanotubes and nitrogen-incorporated ultrananocrystalline diamond (N-UNCD) thin films, the latter developed and patented by Argonne National Laboratory. We will present recent investigations of N-UNCD as a robust field emitter, revealing that this material offers stable performance in high vacuum for up to 1000 hours with threshold voltage for emission of about 3-4 V/lJm and current densities in the range of tens of microA. Optimizing the mass resolution and sensitivity of such a mass spectrometer has also been enabled by a parallel effort to scale up a CNT emitter to an array measuring 2 mm x 40 mm. Through simulation and experiment of the new extended format emitter, we have determined that focusing the electron beam is limited due to the angular spread of the emitted electrons. This dispersion effect can be reduced through modification of the electron gun geometry, but this reduces the current reaching the ionization region. By increasing the transmission efficiency of the electron beam to the anode, we have increased the anode current by two orders of magnitude to realize a corresponding enhancement in instrument sensitivity, at a moderate cost to mass resolution. We will report recent experimental and modeling results to describe the performance of a field emission electron gun as employed in the Volatile Analysis by Pyrolysis of Regolith (VAPoR) TOF-MS prototype.

Southard, Adrian E.↗

Data acquisition techniques for exploiting the uniqueness of the time-of-flight mass spectrometer: Application to sampling pulsed gas systems

Mass spectra are produced in most mass spectrometers by sweeping some parameter within the instrument as the sampled gases flow into the ion source. It is evident that any fluctuation in the gas during the sweep (mass scan) of the instrument causes the output spectrum to be skewed in its mass peak intensities. The time of flight mass spectrometer (TOFMS) with its fast, repetitive mode of operation produces spectra without skewing or varying instrument parameters and because all ion species are ejected from the ion source simultaneously, the spectra are inherently not skewed despite rapidly changing gas pressure or composition in the source. Methods of exploiting this feature by utilizing fast digital data acquisition systems, such as transient recorders and signal averagers which are commercially available are described. Applications of this technique are presented including TOFMS sampling of vapors produced by both pulsed and continuous laser heating of materials.

Lincoln, K. A.↗