Search NASA⌕ Search

SEARCH · Search NASA

Results for “tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Synchrotron micro-computed tomography analysis of neutron-irradiated U-Mo fuel

The three-dimensional (3D) microstructure of neutron-irradiated uranium-10 wt.% molybdenum (U-10Mo) fuel with a burn-up of 9.8 × 10 21 fissions/cm 3 was characterized using a novel, multi-modal synchrotron micro-computed tomography approach combining propagation-based phase-contrast enhanced and absorption contrast techniques. The porosity development, porosity interconnectedness, swelling, composition, local thickness of the zirconium (Zr) diffusion barrier, and the influence of the fuel–cladding interaction on the local composition and pore morphology, were uniquely determined in 3D. Two cuboids were produced using a focused ion beam-scanning electron microscope at the Zr diffusion barrier–fuel interface and in the bulk fuel. The bulk fuel sample swelled by 53.3 [+9.7/−3.1]%, while the fuel near the Zr–fuel interface swelled by 63.3 [+14.7/−7.2]%. The average local thickness of the Zr diffusion barrier decreased by 53 %, compared to the expected pre-irradiated thickness. Four pore morphology regions were identified initiating parallel to the fuel–Zr interaction region: (1) an interaction layer of suppressed porosity, (2) a layer of elongated and interconnected porosity, (3) a transition zone of low porosity, and (4) a layer of unoriented porosity representative of the bulk fuel behavior. The increase in porosity near the diffusion barrier corresponded to a higher U concentration compared to that in the bulk fuel. The interconnected porosity in the fuel near the diffusion barrier was extensive and oriented parallel to the diffusion barrier, while the bulk fuel had more compact and isolated pore networks. The interaction layer, despite having suppressed porosity, was nearly 100 wt.% U. Porosity suppression at the diffusion barrier corresponds to the expected reduction in radiation-driven diffusion of Xe at the interface despite the anticipated increase in fission product nucleation originating from a higher U concentration. In conclusion, the novel 3D insights of the porosity, swelling, and compositional variations characterized herein can improve the fidelity of fuel performance codes for proliferation-resistant fuels for research and test reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Post-irradiation examination of AGR-3/4 TRISO fuel compacts using three-dimensional X-ray computed tomography

The AGR-3/4 irradiation tests combined the third and fourth planned irradiation experiments in the US Department of Energy’s Advanced Gas Reactor (AGR) testing campaign of tri-structural isotropic (TRISO) fuel compacts. In this article, we present post-irradiation examination (PIE) using X-ray computed tomography (XCT) of two unirradiated and two irradiated compacts from the AGR-3/4 irradiation tests. The irradiated compacts studied (compact 7–1 and compact 12–4) represent the upper and lower limit of burnup within the AGR-3/4 irradiation experiment. This article presents a detailed quantitative analysis on the post-irradiation structure of TRISO fuel compacts. Various quantitative parameters including shape, size, and packing of kernels, and their spatial distribution, were utilized to gain insights into the structural changes caused by irradiation. The equivalent diameter and sphericity were found to increase and decrease, respectively, in irradiated compact 7–1 due to its higher burnup. Nearest neighbor distance between fuel kernels decreased after irradiation, suggesting irradiation-induced shrinkage of graphitic matrix. Furthermore, each compact in AGR-3/4 irradiation tests contained 20 designed-to-fail (DTF) fuel particles that were meant to act as a source of fission product release to the experiment test train. Furthermore, in the present work, all DTF fuel particles in the four compacts studied were identified, and it was found that they exhibited larger kernel swelling in compact 12–4 and smaller kernel swelling in compact 7–1, compared to the driver particles.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Correlated transmission electron microscopy and atom probe tomography characterization of ion irradiated Ni-based alloy Hastelloy N

Ion irradiation of Hastelloy N was conducted to better characterize the effects of irradiation on Hastelloy N using modern tools compared to studies done in the 1950s. The 2 MeV Ni + ion irradiation at 600 °C of Hastelloy N has been investigated using atom probe tomography, transmission electron microscopy and energy dispersive spectroscopy. Irradiation is found to promote formation of nanoscale M 2 C carbides over the thermodynamically favored M 6 C. Segregation of Si to dislocation loops and grain boundaries was also evident and may have assisted in formation of M 2 C. These microstructural changes result in a 20 % hardness increase caused by irradiation alone. These observations are useful in the design of new materials better suited for the harsh environment of a molten salt reactor.

Atom probe tomography↗

Resolving three-dimensional nanoscale heterogeneities in lithium metal batteries with cryoelectron tomography

Current direct observation of sensitive battery materials and interfaces primarily relies on two-dimensional (2D) imaging, leaving out their three-dimensional (3D) relationship. Here, in this study, we used cryoelectron tomography (cryo-ET) to visualize the lithium metal anode in 3D at nanometer resolution and cryoelectron microscopy (cryo-EM) to reveal atomic details in local regions. We imaged both freshly prepared and calendar-aged Li metal anodes to reveal the development of LiH in Li dendrites and the Li-LiH interface, as well as the development of the solid-electrolyte interphase (SEI). Using a convolutional neural network-based technique, the 3D arrangement of Li metal, along with nanoscale LiH and Cu heterogeneities in dendrites, was visualized and annotated. In longer-term calendar aging, we observed more substantial LiH growth accompanied by extended SEI growth. Our results show that the growth of LiH and the extended SEI during battery calendar aging are temporally and spatially separate processes.

LiH↗

Measuring thermal curing induced shrinkage of material extrusion based additive manufacturing silicone elastomer lattices by X-ray computed tomography

Thermal curing induces shrinkage in material extrusion based additive manufacturing silicone elastomer samples, resulting in discrepancies between as printed and final geometries. Knowing the extent to which the samples change in shape and size allows us to make appropriate modifications to the printing design to better control the geometry of the samples. We present an X-ray computed tomography (CT) based approach to determine filament-level shrinkage due to thermal curing of silicone elastomer samples printed with direct ink writing (DIW). The approach relies on custom-designed build plates that are resistant to the elevated curing temperatures and that have sufficiently distinct X-ray absorption characteristics from the silicone elastomer to ensure adequate segmentation of the latter in X-ray imaging data. We implement the approach to evaluate shrinkage in DIW ‘log pile’ samples with three distinct strand arrangements and demonstrate of how filament-level information can be extracted from the X-ray CT data.

Additive manufacturing↗

On the instrument-dependent appearance of ion dissociation events in atom probe tomography mass spectra

The successful application of atom probe tomography (APT) relies on the accurate interpretation of the mass spectrum (i.e. m/z histogram) from a sample. Some materials yield mass spectra that are amenable to a straightforward peak assignment/ranging, however, there are many materials that produce mass spectra with features that defy simple interpretation. One such example is Ga 2 O 3 which yields mass spectra containing several broad and difficult to interpret features. Herein, we study the GaO 2+ → O 1+ + Ga 1+ dissociation and we explain how this dissociation process gives rise to broad and previously unassigned features in the mass spectrum. Trajectory simulations are performed for the dissociation reaction utilizing realistic electrostatic models and compared to experiments using commercially available straight flight and reflectron based local electrode (LE) APT instruments. It is shown that the appearance of these features is strongly dependent on the specific design of the time-of-flight (ToF) mass analyzer. Additionally, we explore how various experimental parameters can affect the appearance of the dissociation process in the one-dimensional (1D) mass spectrum and in the two-dimensional (2D) correlation histogram. While the focus of this work is on a particular dissociation process related to Ga 2 O 3 , the understanding gained in the course of these simulations and experiments should be applicable to the interpretation of dissociation processes in other materials.

47 OTHER INSTRUMENTATION↗

State-of-Charge Investigation of Lithium Manganese Dioxide Primary Batteries Utilizing X-ray Computed Tomography

Lithium primary batteries (LPBs) represent a class of energy storage devices, uniquely suited for mission-critical applications including emergency backup power, aerospace and defense electronics, implantable medical devices, and remote sensing. Despite their technological maturity and distinct advantages over rechargeable lithium-ion batteries (i.e., superior shelf life and operational simplicity), state-of-charge (SoC) estimation in these batteries remains a persistent challenge due to the lack of a reliable, quantifiable diagnostic technique. In this work, we investigate X-ray computed tomography (X-CT) as a transformative and accurate SoC estimation technique for LPBs. Results gained through X-CT measurements reveal systematic, quantifiable structural changes in cathode morphology and geometry during discharge, establishing a direct structural basis for SoC estimation, with a maximum relative standard deviation of 2.3%. This work establishes a pathway toward operando, imaging-driven SoC diagnostics that can significantly enhance the reliability of SoC estimation in LPBs.

25 ENERGY STORAGE↗

Porous Iron Electrodes Reduce Energy Consumption During Electrocoagulation of a Virus Surrogate: Insights into Performance Enhancements Using Three-Dimensional Neutron Computed Tomography

Electrocoagulation has attracted significant attention as an alternative to conventional chemical coagulation because it is capable of removing a wide range of contaminants and has several potential advantages. In contrast to most electrocoagulation research that has been performed with nonporous electrodes, in this study, we demonstrate energy-efficient iron electrocoagulation using porous electrodes. In batch operation, investigation of the external pore structures through optical microscopy suggested that a low porosity electrode with sparse connection between pores may lead to mechanical failure of the pore network during electrolysis, whereas a high porosity electrode is vulnerable to pore clogging. Electrodes with intermediate porosity, instead, only suffered a moderate surface deposition, leading to electrical energy savings of 21% and 36% in terms of electrocoagulant delivery and unit log virus reduction, respectively. Neutron computed tomography revealed the critical role of electrode porosity in utilizing the electrode’s internal surface for electrodissolution and effective delivery of electrocoagulant to the bulk. Energy savings of up to 88% in short-term operation were obtained with porous electrodes in a continuous flow-through system. Further investigation on the impact of current density and porosity in long-term operation is desired as well as the capital cost of porous electrodes.

42 ENGINEERING↗

Stratification of fluoride uptake among enamel crystals with age elucidated by atom probe tomography

Dental enamel is subjected to a lifetime of de- and re-mineralization cycles in the oral environment, the cumulative effects of which cause embrittlement with age. However, the understanding of atomic scale mechanisms of dental enamel aging is still at its infancy, particularly regarding where compositional differences occur in the hydroxyapatite nanocrystals and what underlying mechanisms might be responsible. Here, we use atom probe tomography to compare enamel from a young (22 years old) and a senior (56 years old) adult donor tooth. Findings reveal that the concentration of fluorine is elevated in the shells of senior nanocrystals relative to young, with less significant differences between the cores or intergranular phases. It is proposed that the embrittlement of enamel is driven, at least in part, by the infusion of fluorine into the nanocrystals and that the principal mechanism is de- and re-mineralization cycles that preferentially erode and rebuild the nanocrystals shells.

36 MATERIALS SCIENCE↗

Visualizing diverse lithium growth and stripping behaviors in anode-free solid-state batteries with operando X-ray tomography

Anode-free solid-state batteries (SSBs), which eliminate the need for lithium metal use during cell assembly, have the potential to enable high energy densities and simplified manufacturing. However, the factors that control lithium growth/stripping at the anode current collector are not well understood. Here, we use operando X-ray microcomputed tomography to comprehensively image and quantify lithium deposition and stripping under various conditions in three different Li|Li 6 PS 5 Cl|current collector cells, revealing diverse behavior that depends on interface morphology, cell resistance, and solid-state electrolyte (SSE) microstructure. A cell with high resistance exhibits extensive lithium filament growth across the entire current collector interface, with filaments that grow around pre-existing pores in the SSE rather than lithium filling these pores. Lithium filament formation is partially reversible, with the cracks shrinking as lithium metal is stripped. Uniform lithium deposition is achievable at low current densities in low-resistance cells, whereas higher current densities in these cells cause an increase in interfacial roughness, which is correlated with subsequent filamentary growth at the edges of the cell. These results provide insight into filamentary vs. planar lithium growth and highlight that the evolution of lithium is sensitively dependent on SSE microstructure and electrochemical processes.

25 ENERGY STORAGE↗

Molecular axis distribution moments in ultrafast transient absorption spectroscopy: A path toward ultrafast quantum state tomography

In ultrafast time-resolved experiments with gas phase molecules, the alignment of the molecular axis relative to the polarization of the interacting laser pulses plays a crucial role in determining the dynamics following this light–matter interaction. The molecular axis distribution is influenced by the interacting pulses and is intrinsically linked to the electronic coherences of the excited molecules. However, in typical theoretical calculations of such interactions, the signal is either calculated for a single molecule in the molecular frame or averaged over all possible molecular orientations to compare with the experiment. Such averaging removes information about anisotropy in the molecular-axis distribution, even though anisotropic contributions can play a significant role in the measured experimental signal. Here, we calculate the laboratory frame transient electronic first-order polarization [P (1) ] spectra in terms of separated molecular frame and laboratory frame quantities. The laboratory frame polarizations are compared with orientation-averaged quantum master equation calculations, demonstrating that orientation-averaging captures only the isotropic contributions. We show that our formalism also allows us to evaluate the anisotropic contributions to the spectrum. Lastly, we discuss the application of this approach to achieve ultrafast quantum state tomography using transient absorption spectroscopy and field observables in nonlinear spectroscopy.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cryogenic electron tomography by the numbers: Charting underexplored lineages in structural cell biology

Imaging cells and their interactions across the whole biosphere with molecular-scale resolution is key for understanding structure–function relations. Cryogenic electron tomography (cryo-ET) is a powerful method for obtaining this critical information. However, cryo-ET studies are challenging and often limited to a small number of cell types per study. Here, we collate cryo-ET data from hundreds of cells and tissues across the biosphere to i) identify emerging methodological trends, ii) pinpoint strategies to reduce imaging time and costs, iii) quantitatively compare methods for cell freezing and sectioning, and iv) census cryo-ET species coverage across all domains of life. Comparing the fraction of cellular material within a single lamella across all domains of life reveals an order of magnitude difference between eukaryotes (1%) compared to bacteria (9%) and archaea (14%). We calculate the fraction of cellular material which can be imaged using distinct sectioning methods on multicellular communities and tissues—identifying serial lift-out as a powerful approach for obtaining more complete cellular depictions. Finally, we show that the biodiversity of current cryo-ET studies is 2 to 3 orders of magnitude lower than in sequence libraries and 4 to 5 lower than the total predicted on Earth. Our analyses reveal major evolutionary lineages which remain critically understudied and highlight where future cryo-ET research would be most impactful.

HPF↗

Validation of the stochastic inversion algorithm for acoustic travel-time tomography: a large eddy simulation study

Acoustic tomography (AT) is explored as a remote sensing technique to obtain instantaneous snapshots of temperature and velocity fluctuations for wind energy applications. This study integrates Large Eddy Simulation (LES) with the Stochastic Inversion (SI) method to validate the algorithm’s capacity for accurate reconstruction of atmospheric fluctuations. The initial findings demonstrate the efficacy of the method in accurately capturing the predominant flow structures. Normalized L2 error evaluations further inform the algorithm’s precision, with errors accentuated in less sampled peripheral regions. The results underscore the method’s promise as a non-intrusive observational tool, with ongoing development poised to improve its precision and reliability.

17 WIND ENERGY↗

Seismic imaging of the Ecuadorian forearc and arc from joint ambient noise, local, and teleseismic tomography: catching the Nazca slab in the act of flattening

SUMMARY The Ecuadorian Andes are a complex region characterized by accreted oceanic terranes driven by the ongoing subduction of the oceanic Nazca plate beneath South America. Present-day tectonics in Ecuador are linked to the downgoing plate geometry featuring the subduction of the aseismic, oceanic Carnegie Ridge, which is currently entering the trench. Using seismic tomography, we jointly invert arrival times of P and S waves from local and teleseismic earthquakes with surface wave dispersion curves to image the structure of the forearc and magmatic arc of the Ecuadorian Andes. Our data set includes > 100 000 traveltimes recorded at 294 stations across Ecuador. Our images show the basement of the central forearc is composed of accreted oceanic terranes with high elastic wave speeds. Inboard of the Carnegie Ridge, the westernmost forearc and coastal cordilleras display relatively low Vp and Vs and high Vp/Vs values, which we attribute to the increased hydration and fracturing of the overriding plate due to the subduction of the thick oceanic crust of the Carnegie Ridge. We additionally image across-arc differences in magmatic architecture. The frontal volcanic arc overlies accreted terranes and is characterized by low velocities and high Vp/Vs indicative of partial melt reservoirs which are limited to the upper crust. In contrast, the main arc displays regions of partial melt across a wider range of depths. The Subandean zone of Ecuador has two active volcanoes built on continental crust suggesting the arc is expanding eastwards. The mid to lower crust does not show indications of being modified from the magmatic process. We infer that the slab is in the process of flattening as a consequence of early-stage subduction of the buoyant Carnegie Ridge.

58 GEOSCIENCES↗

Atom Probe Tomography Investigation of Clustering in Model P 2 O 5 -Doped Borosilicate Glasses for Nuclear Waste Vitrification

Atom probe tomography (APT) has been utilized to investigate the microstructure of two model borosilicate glasses designed to understand the solubility limits of phosphorous pentoxide (P 2 O 5 ). This component is found in certain high-level radioactive defence wastes destined for vitrification, where phase separation can potentially lead to a number of issues relating to the processing of the glass and its long-term chemical and structural stability. The development of suitable focused ion beam (FIB)-preparation routes and APT analysis conditions were initially determined for the model glasses, before examining their detailed microstructures. In a 3.0 mol% P 2 O 5 -doped glass, both visual inspection and sensitive statistical analysis of the APT data show homogeneous microstructures, while raising the content to 4.0 mol% initiates the formation of phosphorus-enriched nanoscale precipitates. This study confirms the expected inhomogeneities and phase separation of these glasses and offers routes to characterizing these at near-atomic scale resolution using APT.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scanning Transmission Electron Microscopy–Atom Probe Tomography Correlative Analysis for the Characterization of Solute-defect Interactions

Atom probe tomography (APT) and (scanning) transmission electron microscopy ((S)TEM) are complementary techniques that provide spatially resolved chemical and structural information at the atomic scale. Here, in this study, we employ two different STEM/APT correlative analysis methods to investigate Cr segregation at dislocation loops in ultra-high purity Fe–Cr alloys. APT needles for the correlative analysis were extracted either from bulk material or from thinned TEM lamellae. STEM analysis was used to determine the Burgers vectors of ion-irradiation-induced dislocation loops, while APT reconstruction of the same region revealed the Cr segregation to these loops. We extended the g•b = 0 invisibility criterion of dislocation loops from TEM mode in a lamella to STEM mode in a needle-shaped specimen. STEM and APT analysis on the same needle provide straightforward correlative analysis, although it is limited by a small observation volume. In contrast, iterative STEM analysis of TEM lamellae, followed by the selective extraction of specific regions of interest for APT analysis, expands the observation area by up to 100 times but requires additional time-consuming steps for APT needle extraction from the lamellae.

47 OTHER INSTRUMENTATION↗

Reducing the Energy Consumption of Magnetic Resonance Imaging and Computed Tomography Scanners: Integrating Ecodesign and Sustainable Operations

This review aims to provide valuable insights into how energy consumption in magnetic resonance imaging (MRI) and computed tomography (CT) scanners can be effectively monitored, managed, and reduced, thereby contributing to more sustainable medical imaging practices. Demand for advanced imaging technologies such as MRI and CT scanners continues to increase, and understanding the resultant impact on greenhouse gas emissions requires a thorough evaluation of their energy consumption. Here, this review examines the energy monitoring and consumption characteristics of MRI and CT scanners, highlighting potential approaches for energy savings. An overview of MRI and CT principles, hardware components, and their associated energy consumption is provided. After addressing the technical aspects, the hardware and software requirements essential for accurate energy metering are detailed. Baseline measurements of energy consumption data are then provided as a foundation to understand current usage patterns and identify areas for improvement. Ongoing efforts to reduce energy consumption are categorized into 3 main strategies: operations, scanner design enhancements, and active scanning techniques, including accelerated MRI protocols. Ultimately, we emphasize that achieving sustainability in medical imaging requires collaboration across disciplines. By incorporating eco-friendly design in new imaging equipment, we can reduce the environmental impact, promote sustainability, and set a health care industry standard for a healthier planet.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deep-learning methods for contrast enhancement and artifact reduction in cryo-electron tomography: a systematic analysis of the state of the art and proposed improvements

Cryo-electron tomography (cryo-ET) has emerged as the preferred technique for visualizing the organization of macromolecular complexes in situ and resolving their structures at subnanometre resolution [Tegunov et al. (2021)View full citation, Nat. Methods, 18, 186–193]. Despite improvements in data quality as a result of advances in detector technology, microscope stability and stage precision, the analysis and interpretation of tomograms remains challenging due to a low signal-to-noise ratio and reconstruction artifacts stemming from experimental constraints in specimen tilt during data collection resulting in a missing wedge in the Fourier space. Recently, self-supervised deep-learning methods have been proposed for contrast enhancement and reduction of resolution anisotropy in reconstructed tomograms. Here, we evaluate several state-of-the-art deep-learning methods which aim to improve the interpretability of cryo-ET reconstructions, with a focus on their performance on downstream tasks of template matching, sub­tomogram averaging and segmentation. We propose new training architectures and a loss function based on Fourier shell correlation that show improved performance over the standard U-Net with L1/L2 losses. We demonstrate our analysis on four diverse experimental datasets: purified 80S ribosomes, in situ Chlamydomonas reinhardtii, immature HIV-1 virus-like particles and INS-1E cells.

contrast enhancement↗