Search NASA⌕ Search

SEARCH · Search NASA

Results for “total”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Total absorption spectroscopy measurement on neutron-rich 74,75 Cu isotopes

This paper reports on the first β-decay study of 74,75 Cu isotopes using the technique of total absorption spectroscopy (TAS). The experiment was performed at the National Superconducting Cyclotron Laboratory at Michigan State University using the Summing NaI(Tl) (SuN) detector. The Cu isotopes are good candidates to probe the single-particle structure in the region because they have one proton outside the Z = 28 shell. Comparing the β-decay intensity distributions in the daughter Zn isotopes to the theoretical predictions provides a stringent test of the calculations. The nuclei in this region are also identified as playing an important role in the astrophysical r-process. Furthermore, the measured β-decay intensity distributions provide essential nuclear physics inputs required to better understand heavy element nucleosynthesis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of total emitted solar-induced chlorophyll fluorescence (SIF) and top-of-canopy (TOC) SIF in estimating photosynthesis

We report many studies have shown that solar-induced fluorescence (SIF) has a good potential to predict gross primary production (GPP) of vegetation. What we measured by remote sensing or near-surface platforms is top-of-canopy (TOC) SIF (SIF toc ), which is not necessarily equal or proportional to total emitted SIF (SIF tot ) from the entire canopy due to the (re)absorption and scattering effects. However, photosynthesis, the process that plants use to fix carbon from the atmosphere, occurs at the entire vertical canopy. Here, by using the recollision theory, we calculated SIF tot at 760 nm from the measured SIF toc , hyperspectral reflectance (R), canopy interception (i) and leaf albedo (ω l ). Among them, both SIF toc and R can be obtained from concurrent TOC spectral measurements; i and ω l in the near-infrared region can be estimated from the open access datasets with a good accuracy. Our result confirms that the measured SIF toc only accounts for a small fraction of SIF tot : the above-the-canopy sensor can only “see” on average 22.9% of SIF tot at Harvard Forest. SIF tot has the following advantages over SIF toc in estimating GPP: (1) SIF tot improves the diurnal estimate of canopy GPP, especially capable to capture the midday depression of photosynthesis which may cause the large discrepancies between SIF toc and GPP on a diurnal basis, (2) SIF tot produces a stronger correlation with GPP from plants with complex canopy structure or under sky conditions with more diffuse irradiance, and (3) the SIF tot -GPP relationship shows a stronger resilience to environmental stresses. The fluorescence escape ratio (f esc ), the ratio between SIF toc multiplied by π and SIF tot , is mostly determined by the sun-canopy-sensor geometry and leaf inclination distribution. The effect of LAI and the leaf chlorophyll concentration on f esc is marginal at the 760 nm wavelength. Our results suggest that converting SIF toc into SIF tot provides a better tool to understand and estimate GPP.

54 ENVIRONMENTAL SCIENCES↗

Cation Short-Range Ordering of MgAl 2 O 4 and NiAl 2 O 4 Spinel Oxides at High Temperatures via In Situ Neutron Total Scattering

Complex oxides that adopt the isometric spinel structure (AB 2 O 4 ) are important for numerous technological applications and are relevant for certain geological processes, which involve exposure to extreme environments such as high pressures and temperatures. Recent studies have shown that the changes to the spinel structure caused by these environments are complex and depend on the material length scale under consideration. In this study we have expanded this approach to the behavior of spinels under high temperature. In situ neutron total scattering experiments, coupled with pair distribution function analysis, performed on two spinel compositions with various levels of pre-existing disorder (MgAl 2 O 4 and NiAl 2 O 4 ) revealed that both compositions trend to a state of maximum disorder where the A and B cations are randomly distributed amongst the two available sites. Temperature-induced cation inversion, conventionally understood as exchange of cations on the A and B sites, is locally expressed as an atomic rearrangement to a tetragonal symmetry, a correlation that is retained up to the maximum temperature studied (1000 °C). Furthermore, a complex thermal expansion behavior is revealed wherein the oxide materials expand heterogeneously at the level of coordination polyhedral with an apparent dependence on bond strength.

36 MATERIALS SCIENCE↗

Development of an Attenuated Total Reflectance–Ultraviolet–Visible Probe for the Online Monitoring of Dark Solutions

Optical spectroscopy is a valuable tool for on-line monitoring of a variety of processes. Ultraviolet-visible (UV-vis) spectroscopy in particular, can monitor the concentration of analytes as well as identify speciation and oxidation state. However, it can be difficult to impossible to employ UV-vis based sensors on chemical systems that are very dark (i.e., high optical density) as exceedingly short pathlengths are required (for transmission approaches) or effective means of backscattering are needed (for reflectance approaches). Examples of processes that would benefit significantly from the use of optical sensors and encounter these challenges include used nuclear fuel recycling and molten salts with high concentrations of dissolved uranium. Utilizing an attenuated total reflectance (ATR) UV-vis approach can overcome these challenges and allow for the measurement of solutions orders of magnitude more concentrated than transmission UV-vis. However, determining ideal sensor specifications for varied processes can be time consuming and expensive. Here, in this study, we evaluate the ability for a novel ATR-UV-vis probe to measure very concentrated solutions of Co(II) and Ni(II) nitrate as well as organic dyes (methylene blue, acid red 1, and crystal violet). This sensor design provides a modular method for exploring possible “pathlengths” by altering the exposed ATR fiber length. Also studied were approaches to loading and measuring the sensor cell. These results are compared to a traditional 1 cm cuvette measured by transmission UV-vis. It was found that the ATR-UV-vis probe was capable of measuring solutions 600 times more concentrated than the 1 cm cuvette. Advanced data analysis in the form of multivariate curve resolution (MCR) was used to analyze the speciation of methylene blue over a large concentration range. The application of this novel ATR-UV-vis probe to the interrogation of dark solutions is a promising avenue for use in on-line monitoring of nuclear processes.

47 OTHER INSTRUMENTATION↗

New Lightning-Derived Vertical Total Electron Content Data Provide Unique Global Ionospheric Measurements

A newly released, novel ionospheric data set of global gridded vertical total electron content (VTEC) is introduced in this paper. This VTEC data set, provided by Los Alamos National Laboratory (LANL), is derived from very high frequency (VHF; defined as 30–300 MHz) broadband radio-frequency (RF) measurements of lightning made by U.S. Department of Defense sensing systems on board Global Positioning System (GPS) satellites. This paper presents the new data set (LANL VTEC), discusses the errors inherent in VHF TEC estimation due to ionospheric dispersion, and compares the LANL VTEC to two community standard VTEC gridded products: Jet Propulsion Laboratory's Global Ionospheric Model (JPL GIM) and the CEDAR community's Open Madrigal VTEC gridded measurements of L-band GNSS (global navigation satellite systems) TEC. We find that the LANL VTEC data have an offset of 3 TECU from CEDAR Madrigal GNSS VTEC and a full-width-half-maximum (FWHM) of 6 TECU. In comparison, the offset between LANL VTEC and the JPL GIM model is –3 TECU, but with a FWHM of 5 TECU. We also compare to Jason-3 VTEC measurements over the ocean, finding an offset of less than 0.5 TECU and an FWHM of <5 TECU. Because this technique uses a completely different methodology to determine TEC, the sources of errors are distinct from the typical ground-based GNSS L-band (GHz) TEC measurements. Also, because it is derived from RF lightning signals, this data set provides measurements in regions that are not well covered by ground-based GPS measurements, such as over oceans and over central Africa.

79 ASTRONOMY AND ASTROPHYSICS↗

Bibliometric review and recent advances in total scattering pair distribution function analysis: 21 years in retrospect

Global research activities have been driven by the quest to develop and characterize novel materials for technological advancements. The total scattering pair distribution function (TSPDF) is a powerful and versatile characterization technique for examining the structural details of diverse complex materials including liquid, amorphous, disordered crystalline, and nanostructured materials. Thus, it is critical to keep track of research progress, identify research gaps, and future research directions of the application of the TSPDF technique in materials development and discovery. In this work, a bibliometric analysis of literature regarding the TSPDF technique between 2000 and 2021 was conducted using datasets retrieved from the Web of Science database. The research trends based on publication outputs, research subject distribution, co-authorships among institutions, countries/regions, co-citation of referenced sources, and keyword co-occurrence are evaluated and discussed herein. The impact of the TSPDF technique is projected to increase due to its importance in probing emerging functional materials, and the advances in specialized facilities and instrumentation among the scientific communities engaged with it. Finally, current and emerging research hotspots related to TSPDF technique such as catalysis, computer modeling and simulation, pharmaceutics, machine learning, hydrogen storage, battery materials, and layered structured materials are also identified and discussed.

36 MATERIALS SCIENCE↗

Isotopically resolved neutron total cross sections at intermediate energies

The neutron total cross sections σ tot of 16,18 O, 58 64 Ni, 103 Rh, and 112,124 Sn have been measured at the Los Alamos Neutron Science Center from low to intermediate energies (3 ≤ E lab ≤ 450 MeV) by leveraging wave-form-digitizer technology. The σ tot relative differences between isotopes are presented, revealing additional information about the isovector components needed for an accurate optical-model description away from stability. Digitizer-enabled σ tot -measurement techniques are discussed and a series of uncertainty-quantified dispersive optical model (DOM) analyses using these new data is presented, validating the use of the DOM for modeling light systems ( 16,18 O) and systems with open neutron shells ( 58,64 Ni and 112,124 Sn). Here, the valence-nucleon spectroscopic factors extracted for each isotope reaffirm the usefulness of high-energy proton reaction cross sections for characterizing depletion from the mean-field expectation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First measurement of the total inelastic cross section of positively charged kaons on argon at energies between 5.0 and 7.5 GeV

ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton liquid argon time projection chamber that operated in a hadron test beam at the CERN Neutrino Platform in 2018. We present a measurement of the total inelastic cross section of charged kaons on argon as a function of kaon energy using 6 and 7 GeV/𝑐 beam momentum settings. The flux-weighted average of the extracted inelastic cross section at each beam momentum setting was measured to be 380 ± 26 mbarns for the 6 GeV/𝑐 setting and 379 ± 35 mbarns for the 7 GeV/𝑐 setting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulating and benchmarking neutron total scattering instrumentation from inception of events to reduced and fitted data

In the design and realization of modern neutron scattering instrumentation, particularly when designing beamline concepts from the ground up, it is desirable to fully benchmark against realistically simulated data. This is especially true for total scattering beamlines, where the future deliverable data is to be analysed in both reciprocal- and real-space representations, and needs must be carefully balanced to ensure sufficient range, resolution and flux of the instrument. An approach to optimize the design of neutron scattering instrumentation via a workflow including ray-tracing simulations, event-based data reduction, heuristic analysis and fitting against realistically simulated spectra is demonstrated here. The case of the DISCOVER beamline concept at the Spallation Neutron Source is used as an example. The results of the calculations are benchmarked through simulation of existing instrumentation and subsequent direct comparison with measured data. Finally, on the basis of the validated models, the ability to explore design characteristics for future beamline concepts or future instrument improvements is demonstrated through the examples of detector tube size and detector layout.

47 OTHER INSTRUMENTATION↗

Pressure cells for in situ neutron total scattering: time and real-space resolution during deuterium absorption

In situ gas-loading sample holders for two-dimensionally arranged detectors in time-of-flight neutron total scattering experiments have been developed to investigate atomic arrangements during deuterium absorption using time and real-space resolution. A single-crystal sapphire container was developed that allows conditions of 473 K and 10 MPa hydrogen gas pressure. High-resolution transient measurements detected deuterium absorption by palladium that proceeded within a few seconds. A double-layered container with thick- and thin-walled vanadium allowed conditions of 423 K and 10 MPa hydrogen gas pressure. The deuterium occupation sites of a lanthanum–nickel–aluminium alloy are discussed in detail on the basis of real-space high-resolution data obtained from in situ neutron scattering measurements and reverse Monte Carlo structural modeling.

08 HYDROGEN↗

Rigid registration algorithm based on the minimization of the total variation of the difference map

Image registration is broadly used in various scenarios in which similar scenes in different images are to be aligned. However, image registration becomes challenging when the contrasts and backgrounds in the images are vastly different. This work proposes using the total variation of the difference map between two images (TVDM) as a dissimilarity metric in rigid registration. A method based on TVDM minimization is implemented for image rigid registration. The method is tested with both synthesized and real experimental data that have various noise and background conditions. The performance of the proposed method is compared with the results of other rigid registration methods. It is demonstrated that the proposed method is highly accurate and robust and outperforms other methods in all of the tests. The new algorithm provides a robust option for image registrations that are critical to many nano-scale X-ray imaging and microscopy applications.

36 MATERIALS SCIENCE↗

On single-crystal total scattering data reduction and correction protocols for analysis in direct space

Data reduction and correction steps and processed data reproducibility in the emerging single-crystal total-scattering-based technique of three-dimensional differential atomic pair distribution function (3D-ΔPDF) analysis are explored. All steps from sample measurement to data processing are outlined using a crystal of CuIr 2 S 4 as an example, studied in a setup equipped with a high-energy X-ray beam and a flat-panel area detector. Computational overhead as pertains to data sampling and the associated data-processing steps is also discussed. Various aspects of the final 3D-ΔPDF reproducibility are explicitly tested by varying the data-processing order and included steps, and by carrying out a crystal-to-crystal data comparison. Situations in which the 3D-ΔPDF is robust are identified, and caution against a few particular cases which can lead to inconsistent 3D-ΔPDFs is noted. Although not all the approaches applied herein will be valid across all systems, and a more in-depth analysis of some of the effects of the data-processing steps may still needed, the methods collected herein represent the start of a more systematic discussion about data processing and corrections in this field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lorentz factor for time-of-flight neutron Bragg and total scattering

We report the three fundamental origins of the Lorentz factor for neutron time-of-flight powder diffraction are revisited. A detailed derivation of the Lorentz factor is presented in the context of diffuse scattering modelling in reciprocal space when perfect periodicity is assumed, and the total scattering pattern is constructed in its discrete form – the factor in this case becomes 1/Q 2 (or d 2 ). Discussion is also presented with respect to practical data reduction where a vanadium measurement is usually taken as the normalization factor (to account for various factors such as detector efficiency), and it is shown that the existence of the Lorentz factor is independent of such a normalization process.

36 MATERIALS SCIENCE↗

Closed-Form Approximation of the Total Variation Proximal Operator

Total variation (TV) is a widely used function for regularizing imaging inverse problems that is particularly appropriate for images whose underlying structure is piecewise constant. TV regularized optimization problems are typically solved using proximal methods, but the way in which they are applied is constrained by the absence of a closed-form expression for the proximal operator of the TV function. A closed-form approximation of the TV proximal operator has previously been proposed, but its accuracy was not theoretically explored in detail. Here, we address this gap by making several new theoretical contributions, proving that the approximation leads to a proximal operator of some convex function, it is equivalent to a gradient descent step on a smoothed version of TV, and that its error can be fully characterized and controlled with its scaling parameter. We experimentally validate our theoretical results on image denoising and sparse-view computed tomography (CT) image reconstruction.

97 MATHEMATICS AND COMPUTING↗

New Total-Ionizing-Dose Resistant Data Storing Technique for NAND Flash Memory

This paper describes a new non-charge-based data storing technique in NAND flash memory called watermark that encodes read-only data in the form of physical properties of flash memory cells. Unlike traditional charge-based data storing method in flash memory, the proposed technique is resistant to total ionizing dose (TID) effects. To evaluate its resistance to irradiation effects, we analyze data stored in several commercial single-level-cell (SLC) flash memory chips from different vendors and technology nodes. These chips are irradiated using a Co-60 gamma-ray source array for up to 100 krad(Si) at Sandia National Laboratories. Experimental evaluation performed on a flash chip from Samsung shows that the intrinsic bit error rate (BER) of watermark increases from 0.8% for TID = 0 krad(Si) to 1% for TID = 100 krad(Si). Conversely, the BER of charge-based data stored on the same chip increases from 0% at TID = 0 krad(Si) to 1.5% at TID = 100 krad(Si). Overall, the results imply that the proposed technique may potentially offer significant improvements in data integrity relative to traditional charge-based data storage for very high radiation (TID > 100 krad(Si)) environments. These gains in data integrity relative to the charge-based data storage are useful in radiation-prone environments, but they come at the cost of increased write times and higher BERs before irradiation.

36 MATERIALS SCIENCE↗

Total-Ionizing-Dose Effects on Read Noise of MLC 3-D NAND Memories T

This paper analyzes the total ionizing dose (TID) effects on noise characteristics of commercial multi-level-cell (MLC) 3-D NAND memory technology during the read operation. Additionally, the chips were exposed to a Co-60 gamma-ray source for up to 100 krad(Si) of TID. We find that the number of noisy cells in the irradiated chip increases with TID. Bit-flip noise was more dominant for cells in an erased state during irradiation compared to programmed cells.

3-D NAND Flash↗

Domain Decomposition for Integer Optimal Control with Total Variation Regularization

Total variation integer optimal control problems admit solutions and necessary optimality conditions via geometric variational analysis. In spite of the existence of said solutions, algorithms which solve the discretized objective suffer from high numerical cost associated with the combinatorial nature of integer programming. Hence, such methods are often limited to small and medium-sized problems. We propose a globally convergent, coordinate descent–inspired algorithm that allows tractable subproblem solutions restricted to a partition of the domain. Our decomposition method solves relatively small trust-region subproblems that modify the control variable on a subdomain only. Given nontrivial subdomain overlap, we prove that a global first-order necessary optimality condition is equivalent to a first-order necessary optimality condition per subdomain. We additionally show that a sufficient decrease is achieved on a single subdomain by way of a trust-region subproblem solver using geometric measure–theoretic arguments, which we integrate with a greedy patch selection to prove convergence of our algorithm. In conclusion, we demonstrate the practicality of our algorithm on a benchmark large-scale, PDE-constrained integer optimal control problem and find that our method is faster than the state of the art.

domain decomposition↗

Total kinetic energy and mass yields from the fast neutron-induced fission of $^{239}\hbox {Pu}$

The total kinetic energy (TKE) release in fission is an important observable, constituting over 80% of the energy released in fission (E f ≈ 200MeV). While the TKE release in the 239 Pu(n,f) reaction was previously measured up to 50 MeV incident neutron energy (E n ), there were features in TKE release at the highest values of E n that were puzzling. There was a marked flattening of TKE release from E n = 30 to 50 MeV, in disagreement with the clearly decreasing TKE observed from E n = 0.5 to 30 MeV. To verify and clarify this trend, TKE measurements at higher values of E n were made. We present absolute measurements of TKE release in 239 Pu(n,f) from E n = 2.4 to 100 MeV. Here, we used silicon PIN detectors to measure the fragment energies and deduce mass-yield curves using the 2E-method. We also discuss fission asymmetry and the relationships between approx. fission fragment mass and distortion.

239Pu↗