Search NASA⌕ Search

SEARCH · Search NASA

Results for “total temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

High-Spatial-Resolution OH and CH2O PLIF Visualization in a Dual-Mode Scramjet Combustor

A high-spatial-resolution planar laser-induced fluorescence (PLIF) imaging system was constructed and used to image a cavity-stabilized, premixed ethylene-air flame. The flame was created within a continuous flow, electrically-heated supersonic combustion facility consisting of a Mach 2 nozzle, an isolator with flush-wall fuel injectors, a combustor with a cavity flameholder of height 9 mm and optical access, and an extender. Tests were conducted at total temperature 1200 K, total pressure 300 kPa, equivalence ratio near 0.4 in the combustor, and Mach number near 0.6 in the combustor. A frequency-doubled Nd:YAG laser pumped a dye laser, which produced light at 283.55 nm. The beam was shaped into a light sheet with full width half-maximum 25 microns, which illuminated a streamwise plane that bisected the cavity. An intensified camera system imaged OH in this plane with a square 6.67 mm field of view and in-plane resolution 39 microns. Images were taken between the backward-facing step and 120 mm downstream of the step. OH structures as small as 110 microns were observed. CH2O was excited using 352.48 nm light; the smallest observed CH2O structures were approximately 200 microns wide. Approximately 15,000 images per species were processed and used to compute composite images.

Geipel, Clayton M.↗

Evaluation of water cooled supersonic temperature and pressure probes for application to 1366 K flows

Water cooled supersonic probes are developed to investigate total pressure, static pressure, and total temperature in high-temperature jet plumes and thereby determine the mean flow properties. Two probe concepts, designed for operation at up to 1366 K in a Mach 2 flow, are tested on a water cooled nozzle. The two probe designs - the unsymmetric four-tube cooling configuration and the symmetric annular cooling design - take measurements at 755, 1089, and 1366 K of the three parameters. The cooled total and static pressure readings are found to agree with previous test results with uncooled configurations. The total-temperature probe, however, is affected by the introduction of water coolant, and effect which is explained by the increased heat transfer across the thermocouple-bead surface. Further investigation of the effect of coolant on the temperature probe is proposed to mitigate the effect and calculate more accurate temperatures in jet plumes.

Lagen, Nicholas↗

Effects of vertical distribution of water vapor and temperature on total column water vapor retrieval error

Results are presented of a test of the physically based total column water vapor retrieval algorithm of Wentz (1992) for sensitivity to realistic vertical distributions of temperature and water vapor. The ECMWF monthly averaged temperature and humidity fields are used to simulate the spatial pattern of systematic retrieval error of total column water vapor due to this sensitivity. The estimated systematic error is within 0.1 g/sq cm over about 70 percent of the global ocean area; systematic errors greater than 0.3 g/sq cm are expected to exist only over a few well-defined regions, about 3 percent of the global oceans, assuming that the global mean value is unbiased.

Sun, Jielun↗

Supersonic combustion of a silane/methane mixture

A test program was conducted to evaluate the ignition and combustion characteristics of a 20 volume percent silane/methane mixture using a model scramjet combustor with Mach 2 combustor entrance conditions. The test gas total temperature was varied from 1200 to 3900 R. The mixture autoignited at a total temperature of 1650 R. This autoignition temperature can be contrasted with 2330 R for hydrogen and 1350 R for a 20 percent silane/hydrogen mixture in similar hardware. Methane without the silane additive did not autoignite in this configuration at temperatures as high as 3900 R.

Northam, G. B.↗

Theoretical study of nonadiabatic boundary-layer stabilization times in a cryogenic wind tunnel for typical stainless steel wing and fuselage models

The time varying effect of nonadiabatic wall conditions on boundary layer properties was studied for a two dimensional wing section and an axisymmetric fuselage. The wing and fuselage sections are representative of the wing root chord and fuselage of a typical transport model for the National Transonic Facility. The analysis was made with a solid wing and three fuselage configurations (one solid and two hollow with varying skin thicknesses) all made from AISI type 310S stainless steel. The displacement thickness and local skin friction were investigated at a station on the model in terms of the time required for these two boundary layer properties to reach an adiabatic wall condition after a 50 K step change in total temperature. The analysis was made for a free stream Mach number of 0.85, a total temperature of 117 K, and stagnation pressures of 2, 6, and 9 atm.

Johnson, C. B.↗

Performance of a high-work, low-aspect-ratio turbine stator tested with a realistic inlet radial temperature gradient

A 0.767-scale model of a turbine stator designed for the core of a high-bypass-ratio aircraft engine was tested with uniform inlet conditions and with an inlet radial temperature profile simulating engine conditions. The principal measurements were radial and circumferential surveys of stator-exit total temperature, total pressure, and flow angle. The stator-exit flow field was also computed by using a three-dimensional Navier-Stokes solver. Other than temperature, there were no apparent differences in performance due to the inlet conditions. The computed results compared quite well with the experimental results.

Stabe, Roy G.↗

Turbulent boundary layer in an adverse pressure gradient without effect of wall curvature

The hypersonic compressible turbulent boundary layer in an adverse pressure gradient along a cylindrical axisymmetric body was studied. The tests were conducted in a Mach 6 contoured axisymmetric nozzle. An external compression cowl was used to produce the gradual adverse pressure gradient and a maximum pressure rise of 7 times the freestream static pressure was achieved in a test region of 23 cm. Boundary layer profiles of static pressure, total pressure, and total temperature, as well as wall transient heat transfer rates were measured. Comparisons of the velocity total temperature profiles to linear and quadratic relations were made. Measured heat transfer data were in good agreement with the prediction from the flat-plate reference enthalpy method. Integral parameters were also in good agreement with results of numerical solutions for compressible turbulent boundary layer equations.

Zakkay, V.↗

Turbulent Flow Field Measurements of Separate Flow Round and Chevron Nozzles with Pylon Interaction Using Particle Image Velocimetry

Particle Image Velocimetry (PIV) measurements for six separate flow bypass ratio five nozzle configurations have recently been obtained in the NASA Langley Jet Noise Laboratory. The six configurations include a baseline configuration with round core and fan nozzles, an eight-chevron core nozzle at two different clocking positions, and repeats of these configurations with a pylon included. One run condition representative of takeoff was investigated for all cases with the core nozzle pressure ratio set to 1.56 and the total temperature to 828 K. The fan nozzle pressure ratio was set to 1.75 with a total temperature of 350 K, and the freestream Mach number was M = 0.28. The unsteady flow field measurements provided by PIV complement recent computational, acoustic, and mean flow field studies performed at NASA Langley for the same nozzle configurations and run condition. The PIV baseline configuration measurements show good agreement with mean flow field data as well as existing PIV data acquired at NASA Glenn. Nonetheless, the baseline configuration turbulence profile indicates an asymmetric flow field, despite careful attention to concentricity. The presence of the pylon increases the upper shear layer turbulence levels while simultaneously decreasing the turbulence levels in the lower shear layer. In addition, a slightly shorter potential core length is observed with the addition of the pylon. Finally, comparisons of computational results with PIV measurements are favorable for mean flow, slightly over-predicted for Reynolds shear stress, and underpredicted for Reynolds normal stress components.

Doty, Michael J.↗

Minimum Energy Test Direction Design in the Control of Cryogenic Wind Tunnels

The advent of the cryogenic wind tunnel concept is attributable to the need for high Reynolds number flow in wind tunnels. The cryogenic wind tunnel concept consists of operating the test medium of a conventional tunnel at cryogenic temperatures down to 80 K. Nitrogen gas, cooled by injected liquid nitrogen, proves to be ideal for the cryogenic tunnel test medium because of its near perfect behavior in insentropic flow. Cryogenic operation of a wind tunnel results in reduced fan power consumption and no penalty in flow dynamic pressure. In a cryogenic tunnel, the flow parameters (Reynolds number, Mach number and flow dynamic pressure) can be independently controlled by separately controlling the tunnel flow variables: total temperature, test section mass flow, and the tunnel total pressure. The problem of closed-loop control of the tunnel total temperature, flow Mach number, and total pressure is addressed and reported.

Balakrishna, S.↗

Static and Wind Tunnel Aero-Performance Tests of NASA AST Separate Flow Nozzle Noise Reduction Configurations

This report presents the results of cold flow model tests to determine the static and wind tunnel performance of several NASA AST separate flow nozzle noise reduction configurations. The tests were conducted by Aero Systems Engineering, Inc., for NASA Glenn Research Center. The tests were performed in the Channels 14 and 6 static thrust stands and the Channel 10 transonic wind tunnel at the FluiDyne Aerodynamics Laboratory in Plymouth, Minnesota. Facility checkout tests were made using standard ASME long-radius metering nozzles. These tests demonstrated facility data accuracy at flow conditions similar to the model tests. Channel 14 static tests reported here consisted of 21 ASME nozzle facility checkout tests and 57 static model performance tests (including 22 at no charge). Fan nozzle pressure ratio varied from 1.4 to 2.0, and fan to core total pressure ratio varied from 1.0 to 1.19. Core to fan total temperature ratio was 1.0. Channel 10 wind tunnel tests consisted of 15 tests at Mach number 0.28 and 31 tests at Mach 0.8. The sting was checked out statically in Channel 6 before the wind tunnel tests. In the Channel 6 facility, 12 ASME nozzle data points were taken and 7 model data points were taken. In the wind tunnel, fan nozzle pressure ratio varied from 1.73 to 2.8, and fan to core total pressure ratio varied from 1.0 to 1.19. Core to fan total temperature ratio was 1.0. Test results include thrust coefficients, thrust vector angle, core and fan nozzle discharge coefficients, total pressure and temperature charging station profiles, and boat-tail static pressure distributions in the wind tunnel.

Mikkelsen, Kevin L.↗

Performance and Operational Characteristics of a Python Turbine-propeller Engine at Simulated Altitude Conditions / Carl L. Meyer and Lavern A. Johnson

The performance and operational characteristics of a Python turbine propeller engine have been investigated over a range of engine operating conditions at simulated altitudes from 5000 to 40,000 feet in the NACA Lewis altitude wind tunnel . For the performance phase of the investigation, a single cowl-inlet ram pressure ratio was maintained and independent control of engine speed and fuel flow was used to obtain a range of power at each engine speed. Engine performance data obtained at a given altitude could not be used to predict performance accurately at other altitudes by use of the standard air pressure and temperature generalizing factors. Specific fuel consumption based on shaft horsepower decreased as the shaft horsepower increased at a given engine speed. At a given altitude condition and turbine -inlet total temperature, there was an optimum engine speed at which maximum shaft horsepower was obtained. At a given engine speed and turbine-inlet total temperature, a greater portion of the total available energy was converted to propulsive power as the altitude increased. Windmilling starts were made at altitudes up to 40,000 feet; the minimum true airspeed required for successful windmilling starts increased as the altitude was raised. In general, the engine control prevented large overshoots or undershoots of engine speed during starts, accelerations, and decelerations.

Engines - Armstrong-Siddely Python Turbo-Propeller↗

Turbulence measurements and noise generation in a transonic cryogenic wind tunnel

A high-frequency combination probe was used to measure dynamic flow quality in the test section of the NASA Langley 0.3-m Transonic Cryogenic Tunnel. The probe measures fluctuating stagnation (total) temperature and pressure, static pressure, and flow angles in two orthogonal planes. Simultaneous measurements of unsteady total temperature and pressure were also made in the settling chamber of the tunnel. The data show that the stagnation temperature fluctuations remain constant, and the stagnation pressure fluctuations increase by a factor of two, as the flow accelerates from the settling chamber to the test section. In the test section, the maximum rms value of the normalized fluctuating velocity is 0.7 percent. Correlation coefficients failed to show vorticity, entropy, or sound as the dominant mode of turbulence in the tunnel.

Ng, W. F.↗

Heat transfer from cylinders in subsonic slip flows

The heat transfer in heated wires was measured using a constant temperature anemometer over a Mach number range from 0.05 to 0.4 and pressures from 0.5 to 8.0 atmospheres. The total temperature ranged from 80 to 120 F and the wire diameters were 0.00015, 0.00032, and 0.00050 inch. The heat transfer data is presented in the form of a corrected Nusselt number. Based on suggested criteria, much of the data was obtained in the slip flow regime. Therefore, the data is compared with data having comparable flow conditions. The possible application of the heat transfer data to hot wire anemometry is discussed. To this end, the sensitivity of the wires to velocity, density, and total temperature is computed and compared using two different types of correlations.

Nagabushana, K. A.↗

Oblique shock-sound interaction at a freestream Mach number of about 20 in helium.

Detailed experimental measurements of the characteristics and level of pre- and postshock disturbances obtained for typical disturbance modes and shock angles are presented to aid in the evaluation of transition studies conducted in 'noisy' hypersonic wind tunnels. The presented data suggest that the shock is probably generating total temperature fluctuations in a fashion directly related to shock strength. Since in high supersonic and hypersonic flows the total temperature fluctuations are mainly contained in velocity fluctuations, it may be concluded that the predominant disturbances generated are vorticity as long as the postshock flow is at a sufficiently high Mach number.-

Weinstein, L. M.↗

Unsteady stagnation-point heat transfer during passage of a concentrated vortex

The unsteady boundary layer due to a single rectilinear vortex filament approaching a 2-D stagnation point is investigated. Assuming the vortex remains far from the surface, incompressible potential flow theory is used to determine the time dependent inviscid flow field. The unsteady boundary layer equations are solved by an alternating-direction-implicit finite-difference method. Two mechanisms which cause fluctuations in heat transfer are the unsteady velocity field in the boundary layer and secondly, the unsteady total temperature at the edge of the boundary layer. The relative importance of these mechanisms is dependent upon the total temperature fluctuations relative to the imposed temperature difference. As a vortex approaches a stagnation point it may be forced to one side of the stagnation line or the other, depending on its initial position. Results are presented for both of these cases.

Rigby, David L.↗

Unsteady stagnation-point heat transfer during passage of a concentrated vortex

The unsteady boundary layer due to a single rectilinear vortex filament approaching a two-dimensional stagnation point is investigated. The unsteady boundary-layer equations are solved by an alternating-direction-implicit finite-difference method. Two mechanisms which cause fluctuations in heat transfer are the unsteady velocity field in the boundary layer and secondly, the unsteady total temperature at the edge of the boundary layer. The relative importance of these mechanisms is dependent upon the total temperature fluctuations relative to the imposed temperature difference.

Rigby, David L.↗

Evaluation of Equilibrium Turbulence for a Hypersonic Boundary Layer at Nonadiabatic Wall Conditions

This paper presents an experimental study to characterize the naturally developing compressible turbulent boundary layer produced along a flat plate measuring 9.7 feet long in the NASA Langley 8-Foot High Temperature Tunnel and to determine the test conditions necessary to achieve equilibrium turbulence. The measurements consist of pitot pressure, static pressure, and total temperature distributions in the boundary layer. In addition, surface measurements consisting of heat transfer and pressure distributions were obtained. The tests were conducted at a nominal free-stream Mach number of 6.5, total temperatures of 2700 and 3300 R, and angles of attack of 5 and 13 degrees. The corresponding nominal boundary-layer edge Mach numbers were 6.2 and 5.0. The nominal ratios of adiabatic wall temperature to cold wall temperature were 4.4 and 5.4 and the momentum thickness Reynolds numbers at the boundary layer probe locations ranged from 400 to 7800. The results of this study indicate that momentum thickness Reynolds numbers of at least 4000 are required to obtain an equilibrium turbulent boundary layer in the Langley 8-Foot High Temperature Tunnel. This evaluation is based primarily on the behavior of shape factors inferred from the boundary-layer measurements.

Albertson, Cindy W.↗

Development and evaluation of a plasma jet flameholder for scramjets

The objective of the work reported herein was to explore the use of a continuous operation plasma torch as an ignitor and flameholder for scramjet combustion. This research was motivated by the desire to eliminate the use of pyrophoric or toxic ignition and/or combustion enhancement materials in operational aircraft or shipboard systems. The total temperatures and torch powers used to ignite/flamehold Mach 2 combustion with hydrogen, ethylene, ethane, and methane were determined. The minimum ignition total temperatures for the fuels tested were hydrogen - 1065 R (lowest test temperature); ethylene - 1500 R; ethane - 2000 R; methane - 2700 R. These temperatures were obtained while operating the torch at a nominal 2 kw net power. The torch was shown to be a good ignitor and flameholder in that both hydrogen and hydrocarbon fuels could be stabilized by the torch and would 'blow off' when the torch was extinguished. The effectiveness of the torch was very sensitive to relative fuel injection location. Best combustion resulted when fuel was injected both upstream and downstream of the torch. These results indicated that an adiabatic plasma torch operating at about 2 kw could be an effective ignitor and flameholder for high-speed combustion.

Northam, G. B.↗