Search NASA⌕ Search

SEARCH · Search NASA

Results for “transfer standard”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Film condensation with high heat fluxes and scaled experiments using pure steam for reactor containment cooling

Condensation tests were performed using a newly developed test facility for scaling the passive containment cooling system (PCCS) to a small modular reactor (SMR). The PCCS of the SMR plays a pivotal role in ensuring greater safety, reliability, and compactness than what is afforded by traditional reactors. Therefore, a well-designed PCCS is essential to SMRs. However, previous studies and test data were unsuitable for scaling, due to high variation in the test geometry and operating conditions. This study intends to close this research gap by using a novel designed scaled test facility consisting of vertical condensing test sections featuring 1-, 2-, and 4-inch-diameter condensing tubes with annular water cooling, and by applying superheated and saturated steam with different steam mass flow ranges of 5–25 g/s. Further, the primary test data, including axial temperatures, mass flow rates, and pressures, were used in conjunction with a standard data reduction method to estimate critical parameters such as heat fluxes, heat transfer coefficients, and condensation rates. These scaled test data would support improving empirical correlations and validating condensation models to identify scaling distortion for SMR PCCSs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Bayesian Inference for the Seismic Moment Tensor Using Regional Waveforms and Teleseismic- P Polarities with a Data-Derived Distribution of Velocity Models and Source Locations

The largest source of uncertainty in any source inversion is the velocity model used in the transfer function that relates observed ground motion to the seismic moment tensor. However, standard inverse procedure often does not quantify uncertainty in the seismic moment tensor due to error in the Green’s functions from uncertain event location and Earth structure. Here, we incorporate this uncertainty into an estimation of the seismic moment tensor using a data-derived distribution of velocity models based on complementary geophysical data sets, including thickness constraints, velocity profiles, gravity data, surface-wave group velocities, and regional body-wave travel times. The data-derived distribution of velocity models is then used as a prior distribution of Green’s functions for use in Bayesian inference of an unknown seismic moment tensor using regional and teleseismic-P waveforms. The use of multiple data sets is important for gaining resolution to different components of the moment tensor. The combined likelihood is estimated using data-specific error models and the posterior of the seismic moment tensor is estimated and interpreted in terms of the most probable source type.

58 GEOSCIENCES↗

Flash Diffusivity Measurement of Semi-Porous Insulation Material Intended for Radioisotope Thermoelectric Generators

This research involves the analysis of flash-heating data pursuant to find the thermal diffusivity of a semi-porous insulation material (Min-K) that is being considered for use in a radioisotope thermoelectric generator (RTG). An RTG uses radioactive nuclear fuel to produce electricity through a temperature difference imposed on a bimetallic thermocouple. Insulation is required to protect sensitive equipment from high temperatures and to conserve heat in the fuel. Using flash diffusivity temperature data, various simulations were fitted in order to find the most appropriate heat transfer model for the experiments. Four models were allowed to compete and the standard deviation of the residuals were compared for each model in evaluating model performance. The residuals are simply the difference in temperatures between the measurements and the mathematical models at each measurement point.

McMasters, Robert L.↗

Reactor Containment Passive Safety Analysis: Steam Condensation in Presence of Non-condensable Gas Scaled Experiment and Modeling

This study presents steam condensation scaled experiments and semi-empirical models in presence of nitrogen (N)—a noncondensable gas (NCG), simulating air in the reactor containment—to support water-cooled small modular reactors (SMRs) passive containment cooling system (PCCS) design and analysis. Previous experimental studies on PCCS are focused on fixed and smaller tube (mostly 2-in.) geometries and specific test condition variations, bringing challenges with geometric scaling and mismatching with SMR prototypic design. To address these challenges, this study presents steam condensation test dataset obtained from three scaled test sections of 1-, 2-, and 4-in.-diameter steam condensers with an annular/jacket cooling of 2-, 3-, and 6 in.-diameter tubes, respectively. Test data were collected for steam ranges from 58 to 63 kg/hr., and NCG flow of 4.4 to 13.3 kg/hr. Annular cooling water flow was varied to obtain required testing conditions of saturated steam inlet and fully condensed outlet. Axial temperature test data of bulk cooling water, steam and condensate were collected by thermocouples for three test sections and various steam-NCG mixing/testing conditions. A standard data reduction method was adopted—utilizing iterative and nodalized mass and heat transfer calculation—to estimate axial local heat fluxes, heat transfer coefficients (HTCs), condensation rates, film thickness, and Nusselt number. Based on the obtained dataset semi-empirical model results—a ratio of experimental and Nusselt’s theoretical HTC are presented. Such results and findings are supportive of developing scaled-up testing facility, to enable model validations and accelerate next generation of reactors development and deployment

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Presentation: Reactor Containment Passive Safety Analysis: Steam Condensation in Presence of Non-condensable Gas Scaled Experiment and Modeling

This study presents steam condensation scaled experiments and semi-empirical models in presence of nitrogen--a noncondensable gas (NCG), simulating air in the reactor containment--to support water-cooled small modular reactors (SMRs) passive containment cooling system (PCCS) design and analysis. Previous experimental studies on PCCS are focused on fixed and smaller tube (mostly 2-in.) geometries and specific test condition variations, bringing challenges with geometric scaling and mismatching with SMR prototypic design. To address these challenges, this study presents steam condensation test dataset obtained from three scaled test sections of 1-, 2-, and 4-in.-diameter steam condensers with an annular/jacket cooling of 2-, 3-, and 6 in.-diameter tubes, respectively. Test data were collected for steam ranges from 58 to 63 kg/hr., and NCG flow of 4.4 to 13.3 kg/hr. Annular cooling water flow was varied to obtain required testing conditions of saturated steam inlet and fully condensed outlet. Axial temperature test data of bulk cooling water, steam and condensate were collected by thermocouples for three test sections and various steam-NCG mixing/testing conditions. A standard data reduction method was adopted--utilizing iterative and nodalized mass and heat transfer calculation to estimate axial local heat fluxes, heat transfer coefficients (HTCs), condensation rates, film thickness, and Nusselt number. Based on the obtained dataset semi-empirical model results--a ratio of experimental and Nusselt's theoretical HTC are presented. Such results and findings are supportive of developing scaled-up testing facility, to enable model validations and accelerate next generation of reactors development and deployment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Tuned Reactivity at the Lithium Metal–Argyrodite Solid State Electrolyte Interphase

Thin intermetallic Li 2 Te–LiTe 3 bilayer (0.75 µm) derived from 2D tellurene stabilizes the solid electrolyte interphase (SEI) of lithium metal and argyrodite (LPSCl, Li 6 PS 5 Cl) solid-state electrolyte (SSE). Tellurene is loaded onto a standard battery separator and reacted with lithium through single-pass mechanical rolling or transferred directly to SSE surface by pressing. State-of-the-art electrochemical performance is achieved, e.g., symmetric cell stable for 300 cycles (1800 h) at 1 mA cm -2 and 3 mAh cm -2 (25% DOD, 60 µm foil). Cryo-stage focused ion beam (Cryo-FIB) sectioning and Raman mapping demonstrate that the Li 2 Te–LiTe 3 bilayer impedes SSE decomposition. The unmodified Li–LPSCl interphase is electrochemically unstable with a geometrically heterogeneous reduction decomposition reaction front that extends deep into the SSE. Decomposition drives voiding in Li metal due to its high flux to the reaction front, as well as voiding in the SSE due to the associated volume changes. Analysis of cycled SSE found no evidence for pristine (unreacted) lithium metal filaments/dendrites, implying failure driven by decomposition phases with sufficient electrical conductivity that span electrolyte thickness. In conclusion, DFT calculations clarify thermodynamic stability, interfacial adhesion, and electronic transport properties of interphases, while mesoscale modeling examines interrelations between reaction front heterogeneity (SEI heterogeneity), current distribution, and localized chemo-mechanical stresses.

25 ENERGY STORAGE↗

Effects of molar expansion ratio of fuels on engine efficiency

Fuel properties have a strong impact on the efficiency of internal combustion engines. Contrary to other physical and thermochemical fuel properties, the molar expansion ratio is normally ignored. Molar expansion ratio is the ratio of number of moles of the products to the reactants. In this work, the impact of the fuel’s molar expansion ratio on engine efficiency is investigated. Findings are based on simulations of a spark ignition engine using different fuels (standard fuels and user-defined fuels) and different dilution ratios. Simulations without heat transfer and friction were performed first. The combustion then takes place at top dead center with a very short combustion duration to approach the ideal Otto cycle. The heat transfer and friction were then added step by step. From this analysis, it could be concluded that the heat loss and friction work decrease as molar expansion ratio increases. The gross indicated and brake thermal efficiencies thus increase. User-defined fuels with different molar expansion ratio, but the same physical and thermochemical properties were then employed. The simulated results showed that the brake thermal efficiency increases by around 1.15% with an increase in molar expansion ratio of 0.02 compared to a fuel with a molar expansion ratio of unity. Lastly, the simulation was also done with air and exhaust gas recirculation dilution.

42 ENGINEERING↗

Evaluating Limits of Machine Learning-Assisted Raman Spectroscopy in Classification of Biological Samples

Machine learning (ML)-assisted Raman spectroscopy has become a powerful analytical tool for the classification and identification of analytes; however, technical challenges impacting its detection accuracy have not been thoroughly investigated. This study explores experimental factors affecting classification performance. Among the evaluated ML models, ML algorithms show minimal impact on classification accuracy. Instead, experimental factors, including spectral similarity between tested samples and data quality, dominate detection performance. Increases in spectral noise and spectral similarity significantly reduce classification accuracy. In well-controlled samples with low experimental noise, ML-assisted Raman spectroscopy can discriminate lipid mixtures with a composition difference of 1.85 mol %. To assess the effect of biological heterogeneity, we analyzed single-cell Raman spectra from Saccharomyces cerevisiae strains carrying single, double, or triple gene mutations. Intrinsic cell-to-cell variability introduced substantial spectral differences, severely reducing the accuracy of multiclass classification of these genetically similar strains at the single-cell level. Averaging Raman spectra across multiple cells improved classification accuracy by reducing this spectral variability. We also assess the effectiveness of transfer learning across different Raman spectrometers, specifically by applying an ML model trained on one instrument to another Raman spectrometer. Transfer learning can be improved with proper instrument calibration, highlighting the importance of instrument standardization. Overall, our results demonstrate that data quality and spectral similarity are the primary bottlenecks in ML-assisted Raman spectroscopy. Careful attention to sample preparation, data acquisition, measurement conditions, and instrument calibration is critical to achieving robust and reliable classification performance.

Fungi↗

DDCP framework

DDCP protocol software 1.0 This repository contains the C++ implementation of version 1.x of the Distributed Data Communications Protocol (DDCP). DDCP provides request/reply, feature discovery, data transfer, control, interrupt, and transaction support for communicating with accelerator instrumentation over UDP. The standard server port is 65000. The framework is a source dependency for services that communicate directly with DDCP hardware. It is not a deployable service by itself.

Joshi, Shreya [Fermi National Accelerator Laborato↗

Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Presentation: Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Uranium Mill Tailings Radiation Control Act Title II DOE Due Diligence and Lessons Learned from a Previous Site Transfer - 20352

Title II of the Uranium Mill Tailings Radiation Control Act (UMTRCA) established that a government agency will provide perpetual care for closed uranium and thorium ore-processing sites that were operating under an NRC source material license in 1978 or were licensed thereafter. Commercial owners (licensees) operating under an NRC or agreement state specific license when UMTRCA was passed are responsible for conducting reclamation of any byproduct material remaining from uranium-ore processing operations in accordance with an NRC or agreement state approved reclamation plan. Reclamation includes both surface and groundwater remedies. Upon completion of reclamation and approval by NRC, the site is required to be transferred to either the host state or the DOE for long-term surveillance and maintenance. Since UMTRCA's enactment, six Title II sites have been transferred to DOE; an additional 24 Title II sites are anticipated to be transferred before 2050. DoE's role mandated under UMTRCA Title II as the long-term care custodian is to perform 'monitoring, maintenance, and emergency measures necessary to protect the public health and safety.' UMTRCA requires that the licensee pay a long-term surveillance charge 'sufficient to cover the annual costs of site surveillance.' However, at some sites such as the Bluewater, New Mexico, Disposal Site, this mandate has required additional effort and expense by DOE, beyond the originally anticipated and intended scope within UMTRCA, but within the authority of DOE under UMTRCA. In 1997, the Bluewater site became the second UMTRCA Title II site to be transferred to DOE. The site was the location of a uranium mill operated from 1953 until 1982. The specific licensee began site reclamation in 1991, and by 1995 all tailings and contaminated materials were encapsulated in two tailings disposal cells and other disposal areas. In addition to surface contamination, milling activities impacted groundwater in the two upper aquifers. In 1989, the specific licensee attempted active groundwater remediation; however, no significant reduction in contaminant concentrations was observed. As a result, the specific licensee applied to NRC for alternate concentration limits (ACLs) in 1990, which were approved in 1996 as being protective, after additional corrective actions were performed. Since transfer of the Bluewater site to DOE, unforeseen challenges have occurred, requiring additional actions. The first challenge is the occurrence of surface depressions located on the northern section of the main tailings disposal cell. The depressions were first observed during DoE's initial inspection in 1998; however, evidence of these can be observed on satellite images taken prior to transfer. Since being first observed, the depressions have continued to grow both in depth and areal extent. Due to the design of the main tailings disposal cell, the depressions impede storm water from being effectively shed off the 101- hectare (250-acre) top slope of the main tailings disposal cell. Instead, storm water accumulates in the depressions, forming a large ephemeral pond that has stored up to 16.3 x 10{sup 6} liters (4.3 million gallons) of stormwater. The ponding poses a potential risk to the integrity of the main tailings disposal cell in the case of a large storm event, with the potential to cause the pond to overtop and erode the cover material and underlying waste. DOE has taken a number of short-term actions to monitor, measure, and reduce the ponding and is currently working with the US Army Corps of Engineers to design and construct a repair. Additional challenges are associated with groundwater at the Bluewater site. Nine wells were present on the 1335-hectare (3300-acre) site upon transfer. Groundwater compliance was called into question after the State of New Mexico reduced its uranium groundwater standard from 5.0 to 0.03 milligrams per liter in 2004, and when an ACL for uranium was exceeded in a site monitoring well in 2010. Acquiring historical groundwater data and subsequent evaluations as well as additional DOE groundwater monitoring led to installing 10 new monitoring wells and performing additional site hydrogeology recharacterization. DOE continues to evaluate groundwater conditions at the site and works with the NRC to determine regulatory requirements and a path forward. As a result of lessons learned at the Bluewater site and other Title II sites, improved processes have been implemented at a programmatic level to increase due diligence before site transfer and prevent similar issues from occurring at other UMTRCA Title II sites under long-term management. DoE's due diligence process is documented in the Process for Transition of UMTRCA Title II Disposal Sites to DOE for Long-Term Surveillance and Maintenance and is designed to ensure that DOE has no technical or compliance concerns with regulatory decisions that might compromise protectiveness following site transfer to DOE. Implementation of the due diligence process has increased DoE's role prior to site transfer and has been effective in identifying potential issues. Actions by NRC and specific licensees, in response to enhanced due diligence efforts by DOE, are expected to minimize, if not totally prevent, the need for unanticipated actions by DOE pertaining to the surface and groundwater remedies after site transfer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pb-Apatite Framework as a Generator of Novel Flat-Band CuO-Based Physics

Based upon density functional theory (DFT) calculations, we present the basic electronic structure of CuPb 9 (PO 4 ) 6 O (Cu-doped lead apatite, aka LK-99), in two scenarios: (1) where the structure is constrained to the P3 symmetry and (2) where no symmetry is imposed. At the DFT level, the former is predicted to be metallic while the latter is found to be a charge-transfer insulator. In both cases the filling of these states is nominally d 9 , consistent with the standard Cu 2+ valence state, and Cu with a local magnetic moment of order 0.7 μ B . In the metallic case we find these states to be unusually flat (∼0.2 eV dispersion), giving a very high density of electronic states (DOS) at the Fermi level that we argue can be a host for novel electronic physics. The flatness of the bands is the likely origin of symmetry-lowering gapping possibilities that would remove the spectral weight from E F . Motivated by some initial experimental observations of metallic or semiconducting behavior, we propose that disorder (likely structural) is responsible for closing the gap. Here, we consider a variety of possibilities that could possibly close the charge-transfer gap but limit consideration to kinds of disorder that preserve electron count. Of the possible kinds we considered (spin disorder, O populating vacancy sites, and Cu on less energetically favorable Pb sites), the local Cu moment, and consequently the charge-transfer gap, remains robust. We conclude that disorder responsible for metallic behavior entails some kind of doping where the electron count changes. Further, we claim that the emergence of the flat bands should be due to weak wave function overlap between the orbitals on Cu and O sites, owing to the directional character of the constituent orbitals. Therefore, finding an appropriate host structure for minimizing hybridization between Cu and O while allowing them to still weakly interact should be a promising route for generating flat bands at E F which can lead to interesting electronic phenomena, regardless of whether LK-99 is a superconductor.

36 MATERIALS SCIENCE↗

Uncertainty analysis of steady-state measurements with a hot-filament type calorimetric emissometer

Calorimetric emissometers measure total hemispherical emissivity by measuring the heat transferred from a heated sample to its surroundings under a vacuum. The accuracy of emissometers standardized by the ASTM C835-06 are well understood. This work uses the Guide to the Evaluation of Uncertainty in Measurement (GUM) for the propagation uncertainties for an ASTM compliant emissometer. The GUM method was able to develop a measurement model and expressions to determine the uncertainty for other emissometers of this type. Data on ‘as-received’ Hastelloy X was used to develop a detailed uncertainty analysis of the emissivity measurement. Data on ‘as-received’ SS 347 and sandblasted A387 Gr. 91 and previous data by the group on A508/A533B were used to determine uncertainty over the ranges 0.16 to 0.81. For all samples, relative uncertainties in emissivities varied from 0.77% to 2.5% when using a fluxgate magnetometer sensor (FMS) to measure the DC heating current. Data on Hastelloy X using a Hall-effect sensor for DC current and low alloy steel showed the DC current and voltage across the test section to be dominate sources of uncertainty. When these sources were reduced, the specimen temperature and the surface area of the test sections were main sources of uncertainty in the emissivity, especially at higher temperatures. As thermal expansion of the surface was considered in the calculations, correlation between specimen temperature and surface area was examined. It was found to be a small contribution to emissivity's uncertainty despite the differences in linear CTE and its uncertainty for the materials analyzed in this study. For low temperatures, the chamber temperature can be a significant source of uncertainty if not sufficiently cooled. The GUM was also briefly compared to uncertainty from the 2nd and 3rd expansions of the Taylor series. We found that the results were the same when rounding to two significant figures.

42 ENGINEERING↗

Catalyzing deep decarbonization with federated battery diagnosis and prognosis for better data management in energy storage systems

Industrial data analytics methods play a central role in improving energy storage performance and efficiency, impacting the future of electrified transportation and renewable electricity generation. However, significant challenges hinder the large-scale deployment of batteries. Conventional methods rely on centralized collection and processing of fleet-level data, leading to database size issues and privacy concerns due to potential data breaches. To enable scalable deployment of battery management systems, this article proposes a federated battery diagnosis and prognosis model, which distributes the processing of battery standard current-voltage-time-usage data in a privacy-preserving manner. Instead of transferring the raw data, this approach communicates only the locally processed parameters, thus reducing communication load and preserving data confidentiality. The federated model offers a paradigm shift in battery health management through privacy-preserving distributed methods for battery data processing and lifetime prediction, ensuring the reliable and sustainable deployment of lithium-ion batteries in a rapidly evolving world.

asset health management↗

Small-scale validation tests for MFIX-Exa CFD-DEM

This report describes several bench-scale fluidization experiments that can be used to validate the CFD-DEM method as encapsulated in the MFIX-Exa code. The five cases considered are the cold-flow fluidized beds of Müller et al., Link et al. (spout-fluid), and Goldschmidt et al. (bi-disperse), the hot fluidized bed of Patil et al., and the adsorbing fluidized bed of Li et al. and Janssen. In most cases, MFIX-Exa with “standard” or “typical” CFD-DEM settings, the Gidaspow drag model, and the Gunn heat transfer provide a relatively good prediction of the quantities considered: mean void fraction profiles, mean velocity profiles, fluctuating velocity profiles, mean particle temperature and segregation index. These results, with other verification and validation tests reported elsewhere, contribute to a body of work providing confidence and credibility in CFD predictions from the MFIX-Exa code.

97 MATHEMATICS AND COMPUTING↗

An Experimental Investigation of Heat Transfer for Supercritical Carbon Dioxide Cooling in a Staggered Pin Fin Array

Pin fin geometry in the trailing edge as turbulators in tur-bine blades has been a subject thoroughly researched for the past several decades. To improve the efficiency of turbomachinery, higher turbine inlet temperatures are necessary, introducing the need for internal cooling channel features, such as pin fin arrays. These solutions are necessary to avoid material failure at higher operating conditions by enhancing the heat transfer of the blade. Over the past decade, a shift toward applying supercritical carbon dioxide or sCO2 cycles has shown increased potential compared to the industry standard air cycles. Promising higher cycle ef¬ficiency, smaller footprints, and zero greenhouse gas emissions, sCO2 has become an attractive alternative to well-established air cycles. This alternative cycle introduces the need to re-visit the heat transfer capabilities of internal cooling geometries within this novel operating fluid environment. The first objective of this paper is to experimentally demonstrate the heat transfer charac-teristics of sCO2 as the secondary internal cooling fluid environ¬ment through testing a pin fin array in a closed loop at 200 bar and 400 Celsius inlet conditions, which stands well within the supercritical region of sCO2. Secondly, the experimental process aims to validate numerical simulation methodology for studying sCO2 environments for internal cooling of turbine blades in a matching pin fin geometry.

Wardell, Ryan J↗

Best Practices for Measuring the Modulation Transfer Function of Video Endoscopes

Endoscopes are crucial for assisting in surgery and disease diagnosis, including the early detection of cancer. The effective use of endoscopes relies on their optical performance, which can be characterized with a series of metrics such as resolution, vital for revealing anatomical details. The modulation transfer function (MTF) is a key metric for evaluating endoscope resolution. However, the 2020 version of the ISO 8600-5 standard, while introducing an endoscope MTF measurement method, lacks empirical validation and excludes opto-electronic video endoscopes, the largest family of endoscopes. Measuring the MTF of video endoscopes requires tailored standards that address their unique characteristics. This paper aims to expand the scope of ISO 8600-5:2020 to include video endoscopes, by optimizing the MTF test method and addressing parameters affecting measurement accuracy. We studied the effects of intensity and uniformity of image luminance, chart modulation compensation, linearity of image digital values, auto gain control, image enhancement, image compression and the region of interest dimensions on images of slanted-edge test charts, and thus the MTF based on these images. By analyzing these effects, we provided recommendations for setting and controlling these factors to obtain accurate MTF curves. Our goal is to enhance the standard’s relevance and effectiveness for measuring the MTF of a broader range of endoscopic devices, with potential applications in the MTF measurement of other digital imaging devices.

47 OTHER INSTRUMENTATION↗