Solid-State Transformer and Hybrid Transformer With Integrated Energy Storage in Active Distribution Grids: Technical and Economic Comparison, Dispatch, and Control

Solid-state transformer (SST) and hybrid transformer (HT) are promising alternatives to the line-frequency transformer (LFT) in smart grids. The SST features medium-frequency isolation, full controllability for voltage regulation, reactive power compensation, and the capability of battery energy storage system (BESS) integration with multiport configuration. The HT has a partially-rated converter for fractional controllability and can integrate a small BESS. Fast grid-edge voltage fluctuations from increased solar photovoltaic (PV) and electric vehicle (EV) penetration are difficult to manage for mechanical load tap changers. Hence, along with the trend towards more BESS in the grid, the controllability and the storage integration capability of the SST and HT are of strong interest. However, a review of literature shows existing SST and HT research is mostly at converter level, while system-level assessments are scarce. Assessing technical and economic impacts is critical to understanding the benefits and role of the SST and HT to guide future research, which is presented for the first time in this article. Experimental results from medium-voltage (MV) SST and MV HT prototypes are shown to confirm equipment-level feasibility, where the voltage controllability waveforms of a MV HT prototype are reported for the first time. Comparative simulations are performed on a modified IEEE 34-bus system. Here, a grid-model-less decentralized grid-edge voltage control method and a day-ahead BESS dispatch method are proposed for the SST and HT. The simulations show that the SST and HT with integrated storage can host more PV, achieve peak shaving, mitigate voltage fluctuation and reverse power flow, and support energy arbitrage for operational cost reduction, as compared to the LFT. Moreover, comprehensive analyses of net present value (NPV) and internal rate of return (IRR) are performed under different installed PV capacities, HT’s partial converter ratings, and BESS capacities. Sensitivities to future cost reductions of the PV and BESS are studied. Although the NPV and IRR are currently negative, 60% capital cost reduction or 150% revenue increase will make the SST and HT economically viable in the use case studied.

14 SOLAR ENERGY↗

Renewable Thermal Energy Systems: Systemic Challenges and Transformational Policies (Report 2)

Two important challenges for RTES are the need for significant further innovation and deployment, particularly in the United States. In the face of continued success of other renewable energy technologies, such as solar photovoltaics (PV) and land-based wind energy for electricity, it is worthwhile to evaluate the current state of select RTES technologies in the context of technology innovation systems and energy transitions. This report marks a departure from the existing body of research we are aware of and have contributed to relating to RTES applications for industrial process heat in the United States. Our objectives for this report are fourfold: 1) Begin considering the challenges of RTES deployment in the United States through application of socio-technical and transitions frameworks; 2) Begin applying the theory of RTES as configurational technology innovation systems in the United States and for industrial process heat specifically; 3) Review RTES innovation, policies, and market formation activities in the contexts of Objectives 1 and 2; 4) Identify future paths for RTES research. Ultimately, the challenges associated with scaling the deployment of RTES in the United States are related to the need to develop a well-functioning innovation system that can overcome resistance from a highly stable socio-technical regime within a shrinking window of time to address the climate crisis, U.S. industrial competitiveness, and volatile energy commodity price shocks. Current efforts toward scaling for RTES applications in industry and buildings emphasize the need for further cost reductions, but not for interventions that support actors and their interactions and that increase the legitimacy of the technologies. As a result, there are significant opportunities to analyze the social contexts of RTES that can then be used to inform the design of effective, transformational policy portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On the black hole/string transition

We discuss aspects of the possible transition between small black holes and highly excited fundamental strings. We focus on the connection between black holes and the self gravitating string solution of Horowitz and Polchinski. This solution is interesting because it has non-zero entropy at the classical level and it is natural to suspect that it might be continuously connected to the black hole. Surprisingly, we find a different behavior for heterotic and type II cases. For the type II case we find an obstruction to the idea that the two are connected as classical solutions of string theory, while no such obstruction exists for the heterotic case. We further provide a linear sigma model analysis that suggests a continuous connection for the heterotic case. We also describe a solution generating transformation that produces a charged version of the self gravitating string. This provides a fuzzball-like construction of near extremal configurations carrying fundamental string momentum and winding charges. We provide formulas which are exact in α' relating the thermodynamic properties of the charged and the uncharged solutions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Aircraft observations in a tropical supercluster over the equatorial Indian Ocean during MISO-BOB field campaign

The Monsoon Intra-Seasonal Oscillations in the Bay of Bengal (MISO-BOB) field campaign was conducted in the Indian Ocean during the 2018 and 2019 summer monsoon seasons. WC-130J aircraft of the 53rd Weather Reconnaissance Squadron of the US Air Force participated in the campaign in June 2018. The dropsonde observations across a tropical supercluster showed zonal wind variations in association with the structure of the convectively coupled Kelvin wave (CCKW). Within the supercluster, easterlies (westerlies) were observed in the upper (lower) troposphere; this transformation occurred just below the 0° C level. The cold pool had an easterly component throughout, and it was coldest (by 2.5° C) at the center of the supercluster, deepest (~ 1000 m) at its rear/western end, and shallowest (~ 300 m) at the front/eastern end. The level of free convection (LFC) at the front end was at 897 m altitude. At the eastern flank of the supercluster, zonal convergence in the lower troposphere occurred between 500-1500 m levels above the surface between the westerlies within the supercluster and opposing ambient easterlies. Thus, the uplifting of conditionally unstable air parcels above LFC to the east of the supercluster was likely to occur due to this convergence rather than the cold pool influence. Conversely, the western flank of the supercluster had low-level zonal divergence. These observations support the notion of ‘self-similarity’ among the mesoscale convective systems and large-scale waves.

54 ENVIRONMENTAL SCIENCES↗

The Future of Renewable Energy Transmission: An Autonomous Energy Grid

The drastic price reduction in variable renewable energy, such as wind and solar, coupled with the ease of use of smart technologies at the consumer level, is driving dramatic changes to the power system that will significantly transform how power is made, delivered, and used. Distributed energy resources (DERs)—which can include solar photovoltaic (PV), fuel cells, microturbines, gensets, distributed energy storage (e.g., batteries, ice storage), and new loads (e.g., electric vehicles (EVs), light-emitting diode (LED) lighting, smart appliances, and electric heat pumps)—are being added to electric grids and causing bidirectional power flows and voltage fluctuations that can impact optimal control and system operation. Residential solar installations, customer battery systems, and EVs are all seeing rapid increases in deployments. With DER seeing such increased use, it is not unreasonable to imagine a residential electricity customer having at least five controllable DERs. In future electric grids, as more DERs are integrated, the number of active control points will be too much for current control approaches to effectively manage.

30 DIRECT ENERGY CONVERSION↗

Predictive Direct DC-Link Control for 7.2 kV Three-Port Low-Inertia Solid-State Transformer With Active Power Decoupling

Promising for applications including renewable energy and electric vehicle fast charging, a medium-voltage (MV) solid-state transformer (SST) typically has multiple modules series stacked, which requires the modules to be single phase. One critical issue of the single-phase SST is the double-line-frequency power ripple. Traditionally, large passives are used to buffer the ripple, resulting in significantly increased volume and cost. This article for the first time proposes active power decoupling (APD) for the SST and a predictive direct DC-link control method, using a current-source single-stage SST as an example. An electrolytic capacitor-less buffer port is used to absorb the ripple, which tolerates up to a 30% voltage ripple for small capacitance. The APD SST control is challenging. First, the current-source SST realizes isolation, DC link, and multiport in a single stage. Second, different from conventional SSTs or APD converters, the low-inertia DC link in this SST has a 40% switching ripple, which is difficult to stabilize. To address the control challenge, a direct DC-link control architecture and a predictive control method are proposed. Simulation and experimental results verify the proposed control method on an MV SiC modular soft-switching solid-state transformer (M-S4T) prototype. Here, the proposed APD reduces the SST volume by 53.8%. Importantly, the proposed concept is not limited to the M-S4T but is generic to other SSTs or APD converters.

14 SOLAR ENERGY↗

On the effectiveness of neural operators at zero-shot weather downscaling

Machine-learning (ML) methods have shown great potential for weather downscaling. These data-driven approaches provide a more efficient alternative for producing high-resolution weather datasets and forecasts compared to physics-based numerical simulations. Neural operators, which learn solution operators for a family of partial differential equations, have shown great success in scientific ML applications involving physics-driven datasets. Neural operators are grid-resolution-invariant and are often evaluated on higher grid resolutions than they are trained on, i.e., zero-shot super-resolution. Given their promising zero-shot super-resolution performance on dynamical systems emulation, we present a critical investigation of their zero-shot weather downscaling capabilities, which is when models are tasked with producing high-resolution outputs using higher upsampling factors than are seen during training. To this end, we create two realistic downscaling experiments with challenging upsampling factors (e.g., 8x and 15x) across data from different simulations: the European Centre for Medium-Range Weather Forecasts Reanalysis version 5 (ERA5) and the Wind Integration National Dataset Toolkit. While neural operator-based downscaling models perform better than interpolation and a simple convolutional baseline, we show the surprising performance of an approach that combines a powerful transformer-based model with parameter-free interpolation at zero-shot weather downscaling. We find that this Swin-Transformer-based approach mostly outperforms models with neural operator layers in terms of average error metrics, whereas an Enhanced Super-Resolution Generative Adversarial Network-based approach is better than most models in terms of capturing the physics of the ground truth data. We suggest their use in future work as strong baselines.

17 WIND ENERGY↗

A Generalized Copula-Polynomial Chaos Expansion for Probabilistic Power Flow Considering Nonlinear Correlations of PV Injections

This paper develops a generalized Copula-polynomial chaos expansion (PCE) framework for power system probabilistic power flow that can handle both linear and nonlinear correlations of uncertain power injections, such as wind and PVs. A data-driven Copula statistical model is used to capture the correlations of uncertain power injections. This allows us to resort to the Rosenblatt transformation to transform correlated variables into independent ones while preserving the dependence structure. This paves the way of leveraging the PCE for surrogate modeling and uncertainty quantification of power flow results, i.e., achieving the probabilistic distributions of power flows. Simulations carried out on the IEEE 57-bus system show that the proposed framework can get much more accurate results than other alternatives with different linear and nonlinear power injection correlations.

copula↗

Guest Editorial: Control interactions in power electronic converter dominated power systems

The modern power systems have undergone significant transformations at the generation, transmission, distribution, and utilization levels due to the remarkable advancements in power electronic converter technology. Power electronic converters are now prevalent in various applications, including wind turbine converters, photovoltaic inverters, flexible AC transmission systems (FACTS) and high-voltage DC (HVDC) converters, distributed generators, microgrids, and electric vehicles. The widespread adoption of power electronic converters has revolutionized the power system by providing fast and flexible controllability. However, their unique characteristics, such as fast response, multi-time scale dynamics, reconfigurable control, and varying sizes and capacities, have introduced new stability challenges, fundamentally altering the dynamics of modern power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

7.2 kV Three-Port SiC Single-Stage Current-Source Solid-State Transformer With 90 kV Lightning Protection

This article proposes a multiport modular single-stage current-source solid-state transformer (SST) for applications like photovoltaic, energy storage integration, electric vehicle fast charging, data center, etc. The 7.2 kV 50 kVA current-source SST consists of five input-series output-parallel modules, each based on 3.3 kV SiC reverse-blocking MOSFET-plus-diode modules. The proposed SST has some unique features. First, compared to the voltage-source or matrix converter-based SSTs, the current-source SST has a unique advantage of single-stage isolated AC/DC or AC/AC conversion with an inductive DC link, but no medium-voltage (MV) AC experiments have been reported. This article for the first time demonstrates MV AC current-source SST up to 7.5 kV peak. Second, the multiport SST has a buffer port for active power decoupling (APD) or energy storage integration. The double-line-frequency power ripple from single-phase AC grid normally results in a large capacitor size in MV SSTs. The APD scheme is proposed in MV applications for the first time to enable a reduced DC link and the electrolytic capacitor-less SST with high reliability. Third, as a direct grid-connected converter without line-frequency transformer, insulation and protection are critical. A medium-frequency transformer design passes 55 kV basic-insulation level (BIL) and 60 kV high potential dielectrics withstand test with only 0.09% leakage inductance. Importantly, a lightning protection scheme is presented to protect the SST itself from 90 kV BIL impulse. Fourth, the proposed current-source SST topology is a modular soft-switching solid-state transformer (M-S4T) with full-range zero-voltage switching and controlled dv/dt for low electromagnetic interference. Furthermore, these concepts are verified in a three-port M-S4T prototype with forced oil cooling under single-module, stacked-module, steady-state, and dynamic operations.

14 SOLAR ENERGY↗

South Asia Group for Energy - Sri Lanka

Sri Lanka set a target of generating 70% of its electricity from renewable energy sources by 2030. This goal includes the addition of 5.8 GW of renewable power capacity, comprising hydropower, solar, wind, and biomass, between 2023 and 2030, with an interim target of adding 2.5 GW of renewable capacity by 2026. To accomplish this, Sri Lanka's power grid needs significant transformation and modernization to handle the integration of variable renewable energy sources effectively. The South Asia Group for Energy (SAGE) is helping Sri Lanka's grid operator, the Ceylon Electricity Board (CEB), understand the gaps for operating the grid with higher renewable share and identifying technology and research requirements to establish a variable renewable energy control center.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

A simplified, efficient approach to hybrid wind and solar plant site optimization

Abstract. Wind plant layout optimization is a difficult, complex problem with a large number of variables and many local minima. Layout optimization only becomes more difficult with the addition of solar generation. In this paper, we propose a parameterized approach to wind and solar hybrid power plant layout optimization that greatly reduces problem dimensionality while guaranteeing that the generated layouts have a desirable regular structure. Thus far, hybrid power plant optimization research has focused on system sizing. We go beyond sizing and present a practical approach to optimizing the physical layout of a wind–solar hybrid power plant. We argue that the evolution strategy class of derivative-free optimization methods is well-suited to the parameterized hybrid layout problem, and we demonstrate how hard layout constraints (e.g., placement restrictions) can be transformed into soft constraints that are amenable to optimization using evolution strategies. Next, we present experimental results on four test sites, demonstrating the viability, reliability, and effectiveness of the parameterized evolution strategy approach for generating optimized hybrid plant layouts. Completing the tool kit for parameterized layout generation, we include a brief tutorial describing how the parameterized evolutionary approach can be inspected, understood, and debugged when applied to hybrid plant layouts.

14 SOLAR ENERGY↗

Multiport Control with Partial Power Processing in Solid-State Transformer for PV, Storage, and Fast-Charging Electric Vehicle Integration

This article proposes a multiport control method to enable partial power processing (PPP) in a medium-voltage (MV) multiport solid-state transformer (SST). MV multiport SSTs are promising in integrating low-voltage DC sources or loads such as solar photovoltaic, energy storage, and electric vehicles into smart grids without bulky line-frequency transformers. Compared to voltage-source SST, current-source (CS) SST features single-stage isolated bidirectional AC/AC, AC/DC, or DC/DC conversion using an inductive DC link. For a multiport CS SST, it is revealed in this article that the PPP capability can be enabled through the proposed control without extra hardware, different from the case of voltage-source converters where special hardware architecture is required for the PPP. With the PPP, most power exchange between LV ports is processed by only a fraction of the entire conversion stage, leading to reduced DC-link current, volume, loss, and improved efficiency. The proposed multiport PPP control scheme is analyzed to verify the advantages across a wide voltage and power range against conventional full power processing (FPP) multiport control, using the soft-switching solid-state transformer (S4T) with reduced conduction loss as an example. Comparative experimental results based on a SiC three-port S4T prototype verify the effectiveness of the proposed PPP scheme against the FPP scheme under both steady state and dynamic conditions. Here, the DC-link current reduction is measured to be more than 36%. Significantly, the proposed multiport PPP control scheme is generic and applicable to any hard-switching or soft-switching CS SSTs without extra hardware.

14 SOLAR ENERGY↗

Impedance Methods for Analyzing Stability Impacts of Inverter-Based Resources: Stability Analysis Tools for Modern Power Systems

Power systems around the world are undergoing a major transformation because of the increasing shares of renewable energy, growing deployment of energy storage systems, proliferation of distributed energy resources, electrification of other sectors, and so on. In the United States, wind and solar provided almost 10% of electricity in 2019. The U.S. Energy Information Administration, in its 2020 Annual Energy Outlook, forecasted that the share of electricity from renewables will reach 38% by 2050, of which more than 80% will come from wind and solar. Wind and solar, along with battery energy storage systems, interface with the grid using power electronic inverters; hence, they are collectively referred to as inverter-based resources (IBRs). The increasing annual share of electricity from IBRs in a power system means that during more times of the year, the system will operate at a much higher concentration of IBRs. Figure 1 presents the hourly share of wind and solar generation in the Electric Reliability Council of Texas (ERCOT) system in Texas in 2019. While the annual wind share was at 20%, the instantaneous percentage share was much higher. Moments of high shares of IBRs (>50%) will continue to grow as more IBRs will be deployed in a power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and Optimization of High-frequency Transformer for Isolated Single-Stage Three-Phase AC/DC Converter using Bidirectional Switches

This paper presents the design and optimization of the high-frequency transformer for an isolated single-stage threephase AC/DC converter enabled by the 4H-SiC BiDirectional Field Effect Transistor (BiDFET). Non-dominated Sorting Genetic Algorithm II (NSGA-II) is used to perform a multiobjective optimization to minimize loss, weight, and volume. A 20 kW, 50 kHz hardware prototype based on the selected optimal point is characterized by a power amplifier. The finite element analysis simulation results are also presented to validate the core magnetic flux density and winding electric field strength. The experimental prototype was tested at 800 Vdc/480 Vrms at 10 kW rated power.

BiDFET, High-frequency transformer, Multiobjective↗

Mechanisms of Low-Level Jet Formation in the U.S. Mid-Atlantic Offshore

Abstract Low-level jets (LLJs), in which the wind speed attains a local maximum at low altitudes, have been found to occur in the U.S. mid-Atlantic offshore, a region of active wind energy deployment as of 2023. In contrast to widely studied regions such as the U.S. southern Great Plains and the California coastline, the mechanisms that underlie LLJs in the U.S. mid-Atlantic are poorly understood. This work analyzes floating lidar data from buoys deployed in the New York Bight to understand the characteristics and causes of coastal LLJs in the region. Application of the Hilbert–Huang transform, a frequency analysis technique, to LLJ case studies reveals that mid-Atlantic jets frequently occur during times of adjustment in synoptic-scale motions, such as large-scale temperature and pressure gradients or frontal passages, and that they do not coincide with motions at the native inertial oscillation frequency. Subsequent analysis with theoretical models of inertial oscillation and thermal winds further reveals that these jets can form in the stationary geostrophic wind profile from horizontal temperature gradients alone—in contrast to canonical LLJs, which arise from low-level inertial motions. Here, inertial oscillation can further modulate the intensity and altitude of the wind speed maximum. Statistical evidence indicates that these oscillations arise from stable stratification and the associated frictional decoupling due to warmer air flowing over a cold sea surface during the springtime land–sea breeze. These results improve our conceptual understanding of mid-Atlantic jets and may be used to better predict low-level wind speed maxima. Significance Statement The purpose of this work is to identify and characterize the atmospheric mechanisms that result in an occasional low-level maximum in the wind speed off the U.S. mid-Atlantic coastline. Our findings show that these low-level jets form due to horizontal temperature gradients arising from fronts and synoptic systems, as well as from the land–sea breeze that forces warmer air over the cold ocean surface. This work aids predictability of such jets, improves our understanding of this coastal environment, and has implications for future deployment of offshore wind energy in this region.

17 WIND ENERGY↗

Solar Energy from a Big Picture Perspective to Nanoscale Insights via TOF-SIMS

The world is undergoing a rapid transformation in the ways that we generate and store energy. This has been driven not only by concerns about the climate but by simple economic factors due to the dramatic cost decreases in wind in solar power. In most places of the world where one would now want to build a new power plant, the cheapest option is to use wind of solar for power generation. Abundant clean energy when the sun shines most is driving new research for daily and seasonal energy storage in many different technologies. Here, we will briefly these discuss energy trends as a whole, before diving into our recent contributions to the field using time-of-flight secondary-ion mass spectrometry (TOF-SIMS) to improve the performance and reliability of solar cells.