Search NASA⌕ Search

SEARCH · Search NASA

Results for “trip analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Exploring urban typologies using comprehensive analysis of transportation dynamics

Abstract As urban areas continue to expand and develop, categorizing cities into typologies offers a valuable framework for understanding metropolitan dynamics and fostering inter-city collaboration. However, existing typologies related to urban mobility have limitations, failing to consider cities within a single large urban region and often overlooking crucial dimensions such as trip demand and traffic flow. In this paper, we introduce a transportation-focused characterization for cities within a large urban region, specifically the San Francisco Bay Area, California. We incorporate over 40 metrics across five transportation dimensions: trip demand, road network, multi-modal network, traffic flow, and land use. Specifically, for the trip demand dimension, we include metrics capturing residents’ trip characteristics, such as mode share, intra-city trips, and inter-city trips. Additionally, we analyze the purpose of trips entering the city to gain a deeper understanding of incoming trip patterns. In the traffic flow dimension, we examine metrics like vehicle miles traveled, delay, and congestion to assess the traffic conditions on the street network. These, combined with other dimensions, provide a comprehensive view of a city’s transportation dynamics. Using unsupervised machine learning clustering methods, we identified eight distinct typologies for the Bay Area: Live Work Cities; Job and Activity Magnet Cities; Anchor Cities; Multi-modal Cities; Hyper-connected Cities; Low-density Residential Cities; Medium-density Residential Cities; and Mixed-use Residential Cities. Our findings show that many clusters are strongly influenced by trip demand and traffic flow metrics. Finally, we examine the practicality of this typology and its potential to guide collaborative transportation management strategies. The typologies provide a foundation for dialogue among Bay Area cities, focusing on evaluating shared characteristics and leveraging successes or challenges to develop unified strategies for transportation management.

Kuncheria, Anu↗

A physics‐informed learning technique for fault location of DC microgrids using traveling waves

Abstract Fast and accurate fault location in DC power systems is of particular importance to ensure their reliable operation. One of the approaches for implementing a fast‐tripping protection scheme is to use Traveling waves (TW) initiated by a fault scenario. This paper proposes a physics‐informed machine learning approach that utilizes TWs for fault location in DC microgrids. TWs are extracted by the so‐called multiresolution analysis which identifies the TW's wavelet coefficients for multiple frequency ranges. This paper deploys Parseval's theorem to find the energy of wavelet coefficients as a quantitative metric for describing TWs. The hypothesis of this paper is that once the Parseval energy curves for a specific cable are extracted, they can be utilized to locate faults along with that cable regardless of the DC system in which the cable is deployed. The fault location algorithm uses Parseval energy curves to train a Gaussian Process (GP) estimator. With the Parseval energy values of measured current at the protection device location, the GP estimator is able to estimate fault locations with high accuracy. The effectiveness of the proposed algorithm is verified by simulating a DC microgrid system in PSCAD/EMTDC.

Paruthiyil, Sajay Krishnan↗

Fault Current Control and Protection in a Standalone DC Microgrid Using Adaptive Droop and Current Derivative

This report presents a novel fault detection, characterization, and fault current control algorithm for a standalone solar-photovoltaic (PV) based dc microgrids. The protection scheme is based on the current derivative algorithm. The overcurrent and current directional/differential comparison based protection schemes are incorporated for the dc microgrid fault characterization. For a low impedance fault, the fault current is controlled based on the current/voltage thresholds and current direction. Generally, the droop method is used to control the power-sharing between the converters by controlling the reference voltage. In this article, an adaptive droop scheme is also proposed to control the fault current by calculating a virtual resistance R droop , and to control the converter output reference voltage. For a high impedance fault, differential comparison method is used to characterize the fault. These algorithms effectively control the converter pulsewidth and reduce the flow of source current from a particular converter, which helps to increase the fault clearing time. Additionally, a trip signal is sent to the corresponding dc circuit breaker (DCCB), to isolate the faulted converter, feeder or a dc bus. The dc microgrid protection design procedure is detailed, and the performance of the proposed method is verified by simulation analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary Component Design and Cost Estimation of a Novel Electric-Thermal Energy Storage System Using Solid Particles

Energy storage will become indispensable to complement the uncertainty of intermittent renewable resources and to firm the electricity supply as renewable power generation becomes the mainstream new-built energy source and fossil fuel power plants are phased out to meet carbon-neutral utility targets. Current energy storage methods based on pumped storage hydropower or batteries have many limitations. Thermal energy storage (TES) has unique advantages in scale and siting flexibility to provide grid-scale storage capacity. A particle-based TES system is projected to have promising cost and performance characteristics to meet the future growing energy storage needs. This paper introduces the system and components required for particle TES to become technically and economically competitive. The system integrates electric particle heaters, particle TES within insulated concrete silos, and an efficient air-Brayton combined-cycle power system to provide power for storage durations up to several days via low-cost, high-performance storage cycles. Design specifications and cost estimation of major components in a commercial-scale system are presented in this paper. A techno-economic analysis based on preliminary component designs and performance indicates that particle TES integrated with an air-Brayton combined-cycle power system has a path to achieve the targeted levelized cost of storage of 5 ¢/kWh-cycle at a round-trip efficiency of 50% when taking low-cost energy-specific components and leveraging basic assets from existing thermal power plants. The cost model provides insights for further development and economic potentials for long-duration energy storage.

14 SOLAR ENERGY↗

Alternative Fuel Vehicle Usage and Owner Demographics in New York State

With mounting concerns over climate change and the environmental impact of fossil fuels, the United States has witnessed a growing interest in alternative fuel vehicles (AFVs). In 2021, approximately 1.5 million battery EVs (BEVs), 0.8 million plug-in hybrid EVs (PHEVs), and 5.5 million hybrid EVs (HEVs) were registered in the United States. In the state of New York, a total of 51,900 BEVs, 44,600 PHEVs, and 221,600 HEVs were registered in 2021. The current report presents the results of an analysis of AFV adoption patterns in New York State and the rest of the United States based on data from the 2017 National Household Travel Survey (NHTS). Overall, the report reveals the demographics and mobility factors (e.g., household income, homeownership, and trip length) that contribute to the adoption of AFVs. This study provides insights that can inform policy decisions aimed at promoting sustainable transportation solutions.The 2017 NHTS data showed that the percentage of households owning at least one AFV is lower in New York City compared with that in other regions of New York State. From the NHTS samples, of the 25 households that owned at least one BEV in New York State, 15 households (60%) lived within a 5-mile radius, based on the great circle distance, of the nearest charging station, and 23 households (92%) lived within a 10-mile radius of the nearest charging station. Furthermore, among the 40 households in New York State that own at least one PHEV, 48% (19 households) lived within a 5-mile radius of the closest EV charging station, and 83% (33 households) lived within a 10-mile radius of the nearest charging station. The rest of the United States had a higher percentage of households that own at least one AFV compared with that of New York State. A comparison was made between EV adoption levels using NHTS and EValuateNY, which is a tool that gathers statistics on the electric car market in New York State. The estimates obtained from New York State household samples in NHTS were slightly lower than the data provided by EValuateNY. In New York State and the rest of the United States, households with higher incomes tended to have a higher proportion of AFV ownership compared with those with lower incomes. For example, households in New York State earning $\$ $150,000 or more had an approximately 6% share of owning at least one AFV, which was markedly higher than those earning less than $\$ $100,000 (less than 3%). Additionally, homeowners in New York State and the rest of the United States also exhibited a significantly higher share of AFV ownership compared with that of renters. In New York State, households that own at least one AFV tended to travel farther and had longer travel times compared with their counterparts without an AFV. In terms of households with at least one AFV, households with HEVs tended to have more person trips, longer person miles of travel, and more vehicle miles traveled, resulting in longer travel times than that of households with BEVs or PHEVs. Notably, households with AFVs had a slightly lower share of family and personal business trips but a higher share of social and recreational trips compared with households without AFVs. Additionally, households with at least one AFV tended to have a slightly higher share of walking trips than their counterparts without an AFV. However, the comparisons were not statistically significant. These travel patterns observed in New York State were consistent with those observed in other regions of the United States.

33 ADVANCED PROPULSION SYSTEMS↗

Data-Driven Modeling of a High Capacity Cryogenic System for Control Optimization

The Cryogenic Moderator System (CMS) is responsible for maintaining a steady flow of cold neutrons for numerous physics experiments at the Spallation Neutron Source (SNS) in Oak Ridge National Laboratory (ORNL). Sudden losses in beam power, known as beam trips, cause a major disturbance to the CMS due to large step changes in cooling demands. Ongoing efforts on upgrading the neutron beam power from 1.4 to 2.0MW are expected to generate larger transients that can further strain the CMS subsystems if they are not properly controlled. To manage such disturbances, four flow valves and one electric heater are adjusted by five decentralized proportional-integral-derivative (PID) controllers. However, the original PID gains were calibrated empirically based only on tracking performance and not based on disturbance rejection. To address this issue without compromising current CMS operations, a control-oriented model was developed to recalibrate the PID controllers offline. The zero-dimensional (0-D) model was based on simple physics-based principles and data-driven system identification techniques. The CMS was broken into several subsystems for analysis, each of which corresponds to a parametric model tied to the thermodynamic states of the working fluid. The model parameters were identified using the nonlinear least squares method where the residuals were calculated from available sensor data. Simulation results show that the proposed model can capture the dynamics of the CMS at steady state and during beam trips.

Maldonado Puente, Bryan↗

Cybersecurity for Distance Relay Protection

This project is a DOE follow-up effort on the CREDC workshop held on September 13, 2018 in Cambridge, MA to discuss cybersecurity of distance relays, which considered the benefits, vulnerabilities and risk mitigations for the use of communication systems in power system protection. The objectives of this project are to define the taxonomy of relay protection and associated communications; define use cases describing approaches to reduce the cyber-attack surface on those protective relays; and evaluate the loss of operational functional capability from changes to communication coverage. Mitigating controls will also be evaluated to understand if there are other approaches to reduce attack surfaces while maintaining communications or partial communications. Distance relays are used to protect transmission lines of approximately 10 to 300 miles in length, by detecting short circuits (i.e., faults) on the lines and then tripping circuit breakers in the substation. Such protection systems are a subset of the power system and they incorporate sensing, logic and communication functions. Protection system exposure to cyberattack could be drastically limited by disconnecting relays from all vulnerable communication systems, but this may adversely impact overall power system performance in the absence of cyberattack. This project began with a use case analysis of protection systems with communications, as summarized in this report. It continued with modeling, testing and evaluation in a miniature power system (MPS), located in the Western Area Power Administration (WAPA) Electric Power Training Center (EPTC). The project also incorporated feedback from two industry meetings held in February and September 2019. The suggested next steps account for and complement the work already underway with DOE/CESER funding: 1. Study the performance of LCD and PC vs. PUTT, which is less reliant on communication system performance and GPS timing references. The PUTT scheme could prove to be more resilient to cyberattack or communications-related disruption. It could also be more tolerant of message re-routing with SDN/SDR communication systems. On the other hand, it will be more vulnerable to false tripping during dynamic events or to loss of the voltage signal. The optimum choice of scheme may depend on the specific power system and risk assessment. This study could provide a new template for evaluation based on business functions. 2. Research and develop new methods to detect and monitor distributed physical attacks, possibly using drones, video sensors, thermal sensors, machine learning and other advanced techniques. This will help mitigate the impact of cyberattack on the protection system, and will also help mitigate the impact of wild fires. 3. Implement a scalable PKI for use in electric utility protection systems. This will encourage widespread adoption of secure authentication methods that are already available, but not widely used at present. This will help secure engineering access to the relays. 4. Investigate the use of SDN in combination with SDR to achieve better cybersecurity and electromagnetic security of the network, incorporating path variability. This would help secure both engineering access and peer-to-peer GOOSE messaging. 5. Perform additional testing, with operator evaluation of “red button” scenarios, PUTT vs. LCD, relay mis-operations, and other cyberattacks in the EPTC. This is an important advantage of testing in the EPTC rather than by computer simulation or even hardware-in-the-loop simulation; the EPTC is already dedicated to managing the situational awareness, operator response times and other human impacts. One of the project objectives was to settle on a common nomenclature for this problem space. We have concluded that the OSI layer model, supplemented by ANSI device numbers and other IEEE standards, is already well-accepted by the industry. The IEEE PSRC knowledge base provides a great deal of public information

24 POWER TRANSMISSION AND DISTRIBUTION↗

Vibration of a cryomodule’s coupler during road transportation: Multibody analysis and experimental validation

The road transportation of critical components for cryogenic cryomodules is a challenging task. Indeed, the shipping and the handling of fundamental sub-assemblies can expose these components to harmful dynamic loads that can jeopardize their structural integrity. This article has the purpose of developing a finite element multibody model capable of assessing the acceleration on a test coupler for a cavity of the Single Spoke Resonator 1 subjected to a typical road transportation trip. A multibody model consisting of rigid bodies and finite element–imported flexible bodies has been created allowing a comparison of the simulated and experimental acceleration. Afterwards, an experimental on-road test, whose set-up is described in this article, has been carried out at Fermilab with instrumented components. Being able to effectively simulate and validate the dynamic effects on such sub-assemblies makes it possible, for the future, to simulate more complex structures subject to dynamic loadings, such as the entire cryomodules during shipping. Furthermore, the results from the simulations can be used to guide the design of new suspension systems suitable for the reduction mitigation of structural vibration during the road transportation of cryomodules.

42 ENGINEERING↗

Analysis of Loss-of-Offsite-Power Events: Update

Loss-of-offsite power (LOOP) can have a negative impact on a nuclear power plant’s ability to achieve and maintain safe shutdown conditions. LOOP event frequencies and times required for subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study were based on the operating experience during calendar years 1987–2020, while the most recent 15-year data (i.e., from 2006–2020) were used for most analyses in this report. LOOP events during critical operation that did not result in a reactor trip are not included. Frequencies and durations were determined for four LOOP event categories: plant-centered, switchyard-centered, grid-related, and weather related. Highly significant decreasing trends in the LOOP occurrence rates were identified for All-LOOPs during critical operation (p-value = 0.001) and switchyard-centered LOOPs during critical operation (p-value = 0.002) for the most recent 10-year period (2011–2020). Adverse trends in LOOP durations continue for switchyard-centered LOOPs (p-value = 0.005), All-LOOPs (p-value = 0.019), as well as All-LOOPs during shutdown operation (p-value = 0.003). Statistical tests show the LOOP counts are not uniformly distributed across the 12 months, and variation among the months exists for plant-centered LOOPs (p-value = 0.028), grid-related LOOPs (p-value = 0.021), All-LOOPs (p-value = 0.003), and All-LOOPs during critical operation (p-value = 0.008). The engineering analysis of LOOP data showed for the period of 2006–2020, the equipment failure events were dominated by failures of circuits and relay; human errors have been less frequent and occurred primarily in maintenance; and weather events were dominated by tornadoes and lightning.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Understanding Electric Vehicle Range and Charging Needs: Interactions Between Ambient Temperature, Commute Patterns, and State-of-Charge Usage

Electric vehicle (EV) performance can vary substantially under real-world operating conditions, particularly due to ambient temperature effects on energy consumption, battery behavior, and thermal management requirements. This study quantifies how weather conditions, daily driving patterns, and State-of-Charge (SOC) usage strategies jointly influence EV driving range, charging frequency, and overall energy efficiency. A detailed and experimentally validated Autonomie vehicle model is developed, integrating a powertrain, a mono-zonal cabin model, and a battery electro-thermal model. Three battery sizes (200-, 300-, and 400-mile homologated ranges) are assessed across five commute profiles (20–200 miles) and six ambient temperatures (−18 °C to 50 °C), including scenarios with and without preconditioning. Results show that extreme temperatures could significantly decrease the maximum achievable range by up to 55% in cold conditions (−18 °C) and 40% in hot conditions (50 °C), relative to moderate conditions. Larger battery packs retain a greater fraction of their nominal range under thermal stress, while smaller packs experience sharper relative penalties due to the higher contribution of thermal loads to total energy demand. The analysis further demonstrates that limiting operation to partial SOC windows (e.g., 80–20%), a common real-world practice, significantly reduces achievable range and increases charging frequency, particularly in cold weather. Thermal preconditioning while plugged in is shown to mitigate these effects for short trips, reducing energy consumption by up to 31% in hot conditions and 7% in cold conditions. The findings demonstrate how climate, SOC usage behavior, and thermal management jointly shape the practical driving capability of EVs, highlighting the importance of efficient thermal management and realistic user charging strategies for ensuring reliable EV operation across diverse climatic scenarios.

33 ADVANCED PROPULSION SYSTEMS↗

Impact of Regional and Seasonal Characteristics on Battery Electric Vehicle Operational Costs in the U.S.

This study investigates the operational cost competitiveness of battery electric vehicles (BEVs) in the United States, considering regional climates, energy prices, and driving patterns. By comparing BEVs with plug-in hybrid electric vehicles (PHEVs), hybrid electric vehicles (HEVs), and the alternative use of BEVs and conventional vehicles (Convs), the analysis incorporates thermal dynamometer tests, real-world vehicle miles traveled (VMT), and state-specific energy prices. Using detailed simulations, the study evaluates energy consumption across varying temperatures and driving distances. The findings reveal that, while BEVs remain cost-effective for short trips in moderate climates, PHEVs are more economical for long-range trips and cold environments, due to the excessive cost of using external direct current fast chargers (DCFCs) and reduced BEV efficiency at low temperatures. HEVs are identified as the most cost-efficient option in regions like New England, characterized by high residential electricity prices. These insights are critical for shaping vehicle electrification strategies, particularly under diverse regional and seasonal conditions, and for advancing policies on alternative energy and fuels.

Kim, Kyung-Ho (ORCID:0009000450851732)↗

Optimal Coordination of Electric Vehicles for Grid Services using Deep Reinforcement Learning

Recent research has shown the effectiveness of reinforcement learning (RL) in coordinating electric vehicles (EVs) with vehicle-to-grid capabilities for grid services. However, many of these studies rely on lookup table and deep Q-network techniques, which can be impractical when dealing with continuous states and actions. In addition, existing RL designs inadequately account for battery aging effects, EV user satisfaction, uncertain departure and arrival time, and trip distance, which may compromise effective coordination. This paper aims to bridge these gaps by developing an innovative deep deterministic policy gradient-based RL framework for optimal coordination of EVs. Case studies were carried out using a test system with 100 EVs, and numerical analysis results showed that the proposed RL framework can effectively coordinate EVs to maximize economic benefits and user satisfaction while ensuring the expected battery lifespan.

Das, Avijit↗

Idaho Falls Power Black Start Field Demonstration (Preliminary Outcomes Paper)

This April 2021 field demonstration builds upon a 2017 field demonstration in which it was determined IFP’s HPPs, on their own, can support islanded black start and operation up to 2.5 MW loading. Modeling and hardware-in-the-loop testing was used in the intervening period to design an energy storage solution, specifically using ultracapacitors, to reduce likelihood of generators tripping during the field demonstration. Overall, the 2021 field demonstration tested three different options for meeting IFP’s requirements: innovating the hydropower controls, synchronizing multiple HPPs on the system, and integrating an ultracapacitor energy storage system. This report documents the testing performed. Follow-on analysis will provide additional insights, for example, including a complete table of comparative results between the tests and scenarios. The analysis will also propose a refined design for an energy storage system to meet IFP’s grid islanded needs.

13 HYDRO ENERGY↗

Initiating Event Rates at U.S. Nuclear Power Plants, 2021 Update

Analyzing initiating event rates is important because it indicates trends and patterns of plant performance and provides inputs to several U.S. Nuclear Regulatory Commission (NRC) risk-informed regulatory activities. This report presents an analysis of initiating event frequencies at U.S. commercial nuclear power plants from calendar year 1988 through 2021, as reported in licensee event reports. Engineers with nuclear power plant experience reviewed each event report since the last update to this report to categorize and characterize reactor trips. To be included in this study, an event had to meet all of the following criteria: (1) the event included an unplanned reactor trip (not a scheduled reactor trip on the daily operations schedule), (2) the sequence of events started when the reactor was critical and at or above the point of adding heat, (3) the event occurred at a U.S. commercial nuclear power plant (excluding Fort St. Vrain and LaCrosse), and (4) the event was reported by a licensee event report. Sixteen initiating event groupings are trended and displayed. For some of the categories, relevant events are plotted separately for boiling-water reactors (BWR) and pressurized-water reactors (PWR). P-values are given for the possible presence of a trend over the most recent 10 years. The following trends were identified for the most recent 10 years (2012–2021): • A highly statistically significant decreasing trend was identified for Loss of Offsite Power (p-value = 0.002) • A statistically significant decreasing trend was identified for BWR general transients (p-value = 0.025) • A statistically significant decreasing trend was identified for PWR general transients for the second year in a row (p-value = 0.038).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Initiating Event Rates at U.S. Nuclear Power Plants: 2022 Update

Analyzing initiating event rates is important because it indicates trends and patterns of plant performance and provides inputs to several U.S. Nuclear Regulatory Commission (NRC) risk-informed regulatory activities. This report presents an analysis of initiating event frequencies at U.S. commercial nuclear power plants from calendar year 1988 through 2022, as reported in licensee event reports. Engineers with nuclear power plant experience reviewed each event report since the last update to this report to categorize and characterize reactor trips. To be included in this study, an event had to meet all of the following criteria: (1) the event included an unplanned reactor trip (not a scheduled reactor trip on the daily operations schedule), (2) the sequence of events started when the reactor was critical and at or above the point of adding heat, (3) the event occurred at a U.S. commercial nuclear power plant (excluding Fort St. Vrain and LaCrosse), and (4) the event was reported by a licensee event report. Sixteen initiating event groupings are trended and displayed. For some of the categories, relevant events are plotted separately for boiling-water reactors (BWR) and pressurized-water reactors (PWR). P-values are given for the possible presence of a trend over the most recent 10 years.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of Loss-of-Offsite-Power Events: 2021 Update

Loss-of-offsite power (LOOP) can have a negative impact on a nuclear power plant’s ability to achieve and maintain safe shutdown conditions. LOOP event frequencies and times required for subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study were based on the operating experience during calendar years 1987–2021, while the most recent 15-year data (i.e., from 2007–2021) were used for most analyses in this report. LOOP events during critical operation that did not result in a reactor trip are not included. Frequencies and durations were determined for four LOOP event categories: plant-centered, switchyard-centered, grid-related, and weather-related. These categories (and the All-LOOPs group which contains all LOOPs without regarding of the four categories) could be further grouped by whether a LOOP event occurred during critical operation, during shutdown operation, or during all operations. The following decreasing trends in the LOOP occurrence rates were identified for the most recent 10-year period (2012–2021): All-LOOPs during critical operation, switchyard-centered LOOPs during critical operation, and grid-related LOOPs during critical operation. Adverse trends in LOOP durations continue for switchyard-centered LOOPs during all operations, All-LOOPs during all operations, and All-LOOPs during shutdown operation for the 1997–2021 period. Statistical tests show the LOOP counts for the period of 2007–2021 are not uniformly distributed across the 12 months, and variation among the months exists for grid-related LOOPs during all operations, All-LOOPs during all operations, and All-LOOPs during critical operation. The engineering analysis of LOOP data showed for the period of 2007–2021, the equipment failure events were dominated by failures of relay and other; human errors have been less frequent and occurred primarily in maintenance and switching; and weather were dominated by tornadoes then by lightning and hurricane. Weather was the cause for 45% of LOOPs for the last fifteen years (2007– 2021) but only for 20% of LOOPs for the previous 20 years (1987–2006) .

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Techno-Economic Analysis of a Thermally Integrated Solid Oxide Fuel Cell and Compressed Air Energy Storage Hybrid System

Natural-gas-fueled solid oxide fuel cell (SOFC) systems have the potential for high-efficiency conversion of carbon to power due to the underlying electrochemical conversion process while readily facilitating carbon capture through the separation of the fuel and oxidant sources. Compressed air energy storage (CAES) technology can potentially store significant quantities of energy for later use with a high round-trip efficiency and lower cost when compared with state-of-the-art battery technology. The base load generation capability of SOFC can be coupled with CAES technology to provide a potentially flexible, low-carbon solution to meet the fluctuating electricity demands imposed by the increasing share of intermittent variable renewable energy (VRE) production. SOFC and CAES can be hybridized through thermal integration to maximize power output during periods of high electrical demand and then store power when either demand is low or renewable generation reduces power prices. The techno-economics of a low-carbon hybrid SOFC and CAES system was developed and investigated in the present study. The proposed hybrid system was found to be cost-competitive with other power-generating base-load facilities when power availability was considered. The hybrid system shows increased resilience to changes in a high VRE grid market scenario.

25 ENERGY STORAGE↗

Analysis of pumped thermal energy storage using particle media integrated with concentrating solar power

Pumped Thermal Energy Storage (PTES) is an electricity storage system that converts electricity into thermal energy which is stored and later transformed back into electricity. Previous work has illustrated that particles have low capital costs and can be operated over a wide range of temperatures. PTES with particle storage achieves higher round-trip efficiency and specific power output than when molten salt thermal energy storage is used. This article explores hybrid systems that combine PTES with Concentrating Solar Power (CSP). Hybrid systems share the majority of components thereby reducing costs compared to two stand-alone devices. In addition, hybrid systems can provide multiple services (such as renewable power generation and electricity storage services). Using particle thermal storage in these hybrid concepts provides freedom in choosing the design conditions, since a wide range of operating temperatures is allowable, therefore making it possible to identify hybrid system designs that have good performance. In this article, two concepts for hybrid PTES-CSP are introduced. Thermodynamic models are developed and these are used to evaluate the performance of two hybrid systems. These models account for turbomachinery efficiency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The “Solar Top-Up” Concept uses CSP to increase the temperature delivered by the charging heat pump. The discharging system uses a topping gas cycle and a bottoming steam cycle to fully exploit the available energy. Using solar heat to increase the maximum temperature from 750 K to 1100 K increases the round-trip efficiency from 41 % to 62 % and the specific work output from 88 kJ/kg to 301 kJ/kg. The second concept is a “Dual-Mode” device which provides both electricity storage and solar electricity generation with the same set of components. The PTES-mode and CSP-mode performance are optimized at different design values but careful parameter selection leads to good performance of both modes: one design produces PTES round-trip efficiency > 60 %, CSP heat engine efficiency > 40 %, and specific work outputs > 150 kJ/kg (for both cycles), when the particle receiver temperature is > 1200 K and maximum heat pump temperature is 1100 K.

14 SOLAR ENERGY↗