Search NASA⌕ Search

SEARCH · Search NASA

Results for “ultraviolet radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Estimating UV-B, UV-Erithemic, and UV-A Irradiances From Global Horizontal Irradiance and MERRA-2 Ozone Column Information

The ground ultraviolet (UV) solar radiation is relevant due to its impacts on plastics degradation (mainly UVA) and on human health (UVB and erithemic UV (UVE)). UV ground measurements are not as ubiquitous as the relatively common global horizontal irradiance (GHI) measurements. Three simple models that estimate the UVA, UVB, and UVE components of solar irradiance from GHI and ozone column information are locally adjusted and validated. Five one-minute datasets from three sites in southeastern South America and two in the United States are used for simultaneous solar irradiance and UV data. All sites correspond to temperate mid-latitude regions. Simultaneous atmospheric total ozone column information is obtained from the reanalysis modern-era retrospective analysis for research and applications (MERRA-2) database for each site. Aside from locally adjusted models, average models with a single set of coefficients are also evaluated. For instance, the best average model is able to estimate UVE with a typical uncertainty below 12% and mean biases between +-3%, relative to the average of the measurements. Similar results are reported for the UVB and UVA components. These results, which can be useful in regions with similar climate and geography, provide a simple way to estimate UV irradiance under all-sky conditions with known uncertainty. This is an alternative to global satellite-based UV estimates, which can have high uncertainties at specific locations. Because MERRA-2 information has a global coverage, when coupled with good satellite-based estimates for GHI, UV irradiances can be estimated by this method over a large territory.

environmental UV radiation↗

Operating Lifetime Study of Ultraviolet (UV) Light-Emitting Diode (LED) Products

Light-emitting diodes (LEDs) can emit radiation that spans the range from near infrared (IR) to all three bands of ultraviolet (UV) radiation: UV-A, UV-B, and UV-C. This report focuses on LEDs that emit in one of the three UV bands because they have the potential to displace lowpressure mercury vapor (LPMV) lamps in a variety of industrial processes, including ink and adhesive curing, medical procedures, and germicidal disinfection. However, before emerging UV LED technologies can displace LPMV lamps, the efficiency and reliability of these sources must meet the user’s expectations in each application. An earlier report focused on the construction and initial performance of commercial UV LED products in radiometric and current-voltage (IV) tests [1]. This report focuses on the long-term performance and reliability of the same set of commercial products. The intent of this report is to provide to the lighting industry a benchmark of the state of UV LEDs as of mid-2021 when these products were purchased. Understanding the failure modes and failure rates of UV LEDs is important in improving UV product reliability at the LED, lamp, and luminaire level and is critical to developing products with higher efficiency, lower carbon footprint, and significantly reduced environmental impact than LPMV lamps.

42 ENGINEERING↗

Tailoring the Thickness‐Dependent Optical Properties of Conducting Nitrides and Oxides for Epsilon‐Near‐Zero‐Enhanced Photonic Applications

Abstract The unique properties of the emerging photonic materials, conducting nitrides and oxides, especially their tailorability, large damage thresholds, and, importantly, the so‐called epsilon‐near‐zero (ENZ) behavior, have enabled novel photonic phenomena spanning optical circuitry, tunable metasurfaces, and nonlinear optical devices. This work explores direct control of the optical properties of polycrystalline titanium nitride (TiN) and aluminum‐doped zinc oxide (AZO) by tailoring the film thickness, and their potential for ENZ‐enhanced photonic applications. This study demonstrates that TiN–AZO bilayers support Ferrell–Berreman modes using the thickness‐dependent ENZ resonances in the AZO films operating in the telecom wavelengths spanning from 1470 to 1750 nm. The bilayer stacks also act as strong light absorbers in the ultraviolet regime using the radiative ENZ modes and the Fabry–Perot modes in the constituent TiN films. The studied Berreman resonators exhibit optically induced reflectance modulation of 15% with picosecond response time. Together with the optical response tailorability of conducting oxides and nitrides, using the field enhancement near the tunable ENZ regime can enable a wide range of nonlinear optical phenomena, including all‐optical switching, time refraction, and high‐harmonic generation.

Saha, Soham↗

Fragmentation Dynamics of Fluorene Explored Using Ultrafast XUV-Vis Pump-Probe Spectroscopy

We report on the use of extreme ultraviolet (XUV, 30.3 nm) radiation from the Free-electron LASer in Hamburg (FLASH) and visible (Vis, 405 nm) photons from an optical laser to investigate the relaxation and fragmentation dynamics of fluorene ions. The ultrashort laser pulses allow to resolve the molecular processes occurring on the femtosecond timescales. Fluorene is a prototypical small polycyclic aromatic hydrocarbon (PAH). Through their infrared emission signature, PAHs have been shown to be ubiquitous in the universe, and they are assumed to play an important role in the chemistry of the interstellar medium. Our experiments track the ionization and dissociative ionization products of fluorene through time-of-flight mass spectrometry and velocity-map imaging. Multiple processes involved in the formation of each of the fragment ions are disentangled through analysis of the ion images. The relaxation lifetimes of the excited fluorene monocation and dication obtained through the fragment formation channels are reported to be in the range of a few tens of femtoseconds to a few picoseconds.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing coherent electronic superpositions of singly and doubly excited states of krypton with extreme-ultraviolet four-wave-mixing spectroscopy

Radiative nonlinear four-wave mixing can monitor the evolution of electronic wave packets, providing access to lifetimes and quantifying the light-induced couplings between excited states. In this article, we report the observation of quantum beats in an autoionizing electronic wave packet in krypton, probed using this technique. Analysis of the signal reveals that these beats originate from the contribution of previously unassigned, doubly excited states interacting with singly excited ones. We introduce a minimal theoretical model, based on multichannel quantum-defect theory, which quantitatively reproduces both the wave-packet dynamics and the static spectrum. This work combines a versatile, noncommensurate XUV-IR-based experimental scheme with a tractable model, establishing a powerful approach for the metrology and control of complex, correlated electronic states.

74 ATOMIC AND MOLECULAR PHYSICS↗

Jupiter in the Ultraviolet: Acetylene and Ethane Abundances in the Stratosphere of Jupiter from Cassini Observations between 0.15 and 0.19 μm

At wavelengths between 0.15 and 0.19 μm, the far-ultraviolet spectrum of Jupiter is dominated by the scattered solar spectrum, attenuated by molecular absorptions primarily by acetylene and ethane, and to a lesser extent ammonia and phosphine. We describe the development of our radiative transfer code that enables the retrieval of abundances of these molecular species from ultraviolet reflectance spectra. As a proof-of-concept we present an analysis of Cassini Ultraviolet Imaging Spectrograph (UVIS) observations of the disk of Jupiter during the 2000/2001 flyby. The ultraviolet-retrieved acetylene abundances in the upper stratosphere are lower than those predicted by models based solely on infrared thermal emission from the mid-stratosphere observed by the Composite Infrared Spectrometer (CIRS), requiring an adjustment to the vertical profiles above 1 mbar. We produce a vertical acetylene abundance profile that is compatible with both CIRS and UVIS, with reduced abundances at pressures <1 mbar: the 0.1 mbar abundances are 1.21 ± 0.07 ppm for acetylene and 20.8 ± 5.1 ppm for ethane. Finally, we perform a sensitivity study for the JUICE ultraviolet spectrograph, which has extended wavelength coverage out to 0.21 μm, enabling the retrieval of ammonia and phosphine abundances, in addition to acetylene and ethane.

79 ASTRONOMY AND ASTROPHYSICS↗

Ionizing-radiation beam monitoring system

A transmissive ionizing-radiation beam monitoring system includes an enclosure structure with at least one ultra-thin window to an incident ionizing-radiation beam, where the ultra-thin window is highly transmissive to ionizing-radiation. Embodiments include at least one thin or ultra-thin scintillator within the enclosure structure that is substantially directly in an incident ionizing-radiation beam path and transmissive to the incident radiation beam, and at least one ultraviolet (UV) illumination source within the enclosure structure facing the scintillator. Embodiments include at least one machine vision camera within the enclosure structure located out of an incident ionizing-radiation beam path and including a camera body and lens having a projection of its optical axis oriented at an angle of incidence of 45±35 degrees to a surface of the scintillator.

Friedman, Peter S.↗

A Lyα Transit Left Undetected: the Environment and Atmospheric Behavior of K2-25b

K2-25b is a Neptune-sized exoplanet (3.45R {sub ⊕}) that orbits its M4.5 host with a period of 3.48 days. Due to its membership in the Hyades Cluster, the system has a known age (727 ± 75 Myr). K2-25b’s youth and its similarities with Gl 436b suggested that K2-25b could be undergoing strong atmospheric escape. We observed two transits of K2-25b at Lyα using HST/STIS in order to search for escaping neutral hydrogen. We were unable to detect an exospheric signature, but placed an upper limit of (R {sub p}/R {sub ⋆})∣{sub Ly α} < 0.56 at 95% confidence by fitting the light curve of the Lyα red wing, or < 1.20 in the blue wing. We reconstructed the intrinsic Lyα profile of K2-25 to determine its Lyα flux, and analyzed XMM-Newton observations to determined its X-ray flux. Based on the total X-ray and extreme ultraviolet irradiation of the planet (8763 ± 1049 erg s{sup −1} cm{sup −2}), we estimated the maximum energy-limited mass-loss rate of K2-25b to be 10.6{sub −6.13}{sup +15.2}×10{sup 10} g s{sup −1} (0.56M {sub ⊕} per 1 Gyr), five times larger than the similarly estimated mass-loss rate of Gl 436b (2.2 × 10{sup 10} g s{sup −1}). The photoionization time is about 3 hr, significantly shorter than Gl 436b’s 14 hr. A nondetection of a Lyα transit could suggest K2-25b is not significantly losing its atmosphere, or factors of the system are resulting in the mass loss being unobservable (e.g., atmosphere composition or the system’s large high-energy flux). Further observations could provide more stringent constraints.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ionizing-radiation beam monitoring system

Embodiments are directed generally to an ionizing-radiation beam monitoring system that includes an enclosure structure with at least one ultra-thin window to an incident ionizing-radiation beam. Embodiments further include at least one scintillator within the enclosure structure that is substantially directly in an incident ionizing-radiation beam path and at least one ultraviolet illumination source within the enclosure structure and facing the scintillator. At least one pixelated imaging system within the enclosure structure is located out of an incident ionizing-radiation beam path and includes at least one pixelated photosensor device optically coupled to an imaging lens.

Friedman, Peter S.↗

Direct reconstruction of isolated XUV or soft x-ray attosecond pulses from high-harmonic generation streaking spectra

Characterization of an isolated attosecond pulse (IAP) in the extreme ultraviolet (XUV) or soft x-ray (SXR) region is essential for its applications. Here we propose to retrieve an IAP in the time domain directly through the modulation of high-harmonic generation (HHG) spectra in the presence of a time-delayed intense few-cycle infrared or mid-infrared laser. The retrieval algorithm is derived based on the strong-field approximation and an extended quantitative rescattering model. We show that both isolated XUV pulses with a narrow spectral bandwidth and isolated SXR pulses with a broad bandwidth can be well characterized through the HHG streaking spectra. Such an all-optical method for characterizing the IAP differs from the commonly used approach based on the streaked photoelectron spectra that would require electron spectrometers. We check the robustness of the retrieval method by changing the dressing laser or by adjusting the steps of time delay. We also show that the XUV pulse can be accurately retrieved by treating the HHG streaking spectra calculated from solving the time-dependent Schrödinger equation for single atoms as the ‘experimental’ data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Understanding the Structure and Dynamics of Complex Biomembrane Interactions by Neutron Scattering Techniques

The membrane is one of the key structural materials of biology at the cellular level. Composed predominantly of a bilayer of lipids with embedded and bound proteins, it defines the boundaries of the cell and many organelles essential to life and therefore is involved in almost all biological processes. Membrane-specific interactions, such as drug binding to a membrane receptor or the interactions of an antimicrobial compound with the lipid matrix of a pathogen membrane, are of interest across the scientific disciplines. Herein we present a review, aimed at nonexperts, of the major neutron scattering techniques used in membrane studies: small-angle neutron scattering, neutron membrane diffraction, neutron reflectometry, quasielastic neutron scattering, and neutron spin echo. Neutron scattering techniques are well suited to studying biological membranes. The nondestructive nature of cold neutrons means that samples can be measured for long periods without fear of beam damage from ultraviolet, electron, or X-ray radiation, and neutron beams are highly penetrating, thus offering flexibility in samples and sample environments. Most important is the strong difference in neutron scattering lengths between the two most abundant forms of hydrogen, protium and deuterium. Changing the relative amounts of protium/deuterium in a sample allows the production of a series of neutron scattering data sets, enabling the observation of differing components within complex membrane architectures. This approach can be as simple as using the naturally occurring neutron contrast between different biomolecules to study components in a complex by changing the solution H 2 O/D 2 O ratio or as complex as selectively labeling individual components with hydrogen isotopes. This review presents an overview of each experimental technique with the neutron instrument configuration, related sample preparation and sample environment, and data analysis, highlighted by a special emphasis on using prominent neutron contrast to understand structure and dynamics. This review gives researchers a practical introduction to the often enigmatic suite of neutron beamlines, thereby lowering the barrier to taking advantage of these large-facility techniques to achieve new understandings of membranes and their interactions with other molecules.

59 BASIC BIOLOGICAL SCIENCES↗

Use of a Mylar filter to eliminate vacuum ultraviolet pulse pileup in low-energy x-ray measurements

We describe a method to reduce vacuum ultraviolet (VUV) pulse pileup (PPU) in x-ray pulse-height Silicon Drift Detector (SDD) signals. An Amptek FAST SDD, with C1 (Si 3 N 4 ) window, measures bremsstrahlung emitted from PFRC-2 plasma to extract the electron temperature (T e ) and density (n e ). The C1 window has low transmissivity for photons with energy below 200 eV though will transmit some VUV and soft x-ray photons, which PFRC-2 plasmas abundantly emit. Multi-VUV-photon PPU contaminates the interpretation of x rays with energy > 100 eV, particularly in a low-energy exponential tail. The predicted low transmissivity of ~1 μm thick Mylar [polyethylene terephthalate (PET)] to photons of energy <100 eV led to the selection of Mylar as the candidate filter to reduce VUV PPU. Experiments were conducted on an x-ray tube with a graphite target and on a quasi-Maxwellian tenuous plasma (n e ~ 10 9 cm –3 ) with effective temperatures reaching 1500 eV. A Mylar filter thickness of 850 nm is consistent with the results. The Mylar-filter-equipped SDD was then used on the PFRC-2 plasma, showing a substantial reduction in the low-energy x-ray signal, supporting our hypothesis of the importance of VUV PPU. Here, we describe the modeling and experiments performed to characterize the effect of the Mylar filter on SDD measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Informing solar blind radioluminescence imaging through a calibrated spectrum

While direct radiation detection methods offer great insight into the origin of ionizing particles and photons, their use to locate contaminated areas or concealed radioactive sources can lead to undue exposure of personnel and equipment to ionizing radiation or the potential for contamination. These same sources induce ultraviolet (UV) optical photon fluorescence in air – a process referred to as radioluminescence – that may be imaged from low dose regions over larger attenuation lengths than ionizing radiation. However, most optical detection methods are limited to low lighting conditions to image the more abundant ultraviolet-A (UV-A) photons. To extend this capability to room light or daytime conditions, the solar blind region (Ultraviolet-C (UV-C), <280 nm) can be tapped. Though the emission yield of UV-C photons is roughly two orders of magnitude lower than that in the UV-A regime, the UV-C offers dramatic improvements in signal-to-noise ratios under bright lighting conditions due to decreased background interferences. The yield of specific UV-C lines, if present in the literature at all, varies widely, which has a large impact in modeling and analyzing standoff UV-C measurement scenarios. Thus, we have captured improved radioluminescence spectra over 250–400 nm and identified observed emission peaks in ambient air. Many of the UV-C photons produced by ionizing radiation excitation result from high-energy, molecular nitrogen Gaydon-Herman transitions which have had limited study to date for this application. Relating these findings to published UV-A yields, we estimate emissions between 0.15–0.19 photons/MeV over 250–280 nm. Additionally, we also use a commercial corona-discharge imaging camera to demonstrate outdoor UV-C radiation mapping of alpha and gamma emitters from 50 and 75 m standoffs, respectively. The imaged “counts” are compared to optically modelled values and show the same trend over distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of UV-light and pH on the Fate of Tc, I, and U in Wetlands at Savannah River Site - 20230

The Savannah River Site (SRS) is one of the major nuclear facilities owned by the U.S Department of Energy. During the Cold War, these facilities produced large amounts of radioactive and hazardous waste. On site, three unlined seepage basins in the F-Area received approximately 1.8 billion gallons of low-level waste containing nitric acid, radionuclides, and dissolved metals due to plutonium and tritium production operations. The acidic nature of the waste created a source of relatively mobile radionuclides below the basins. Radionuclides previously disposed of within the F-Area, including uranium isotopes (U), technetium-99 (Tc-99), and iodine-129 (I-129), are moving with groundwater towards Four Mile Branch Wetland, where they are subsequently upwelling and interacting with natural organic matter (NOM). Many environmental factors including redox conditions, porewater composition, pH, light, and temperature affect the degradation of organic matter as well as interactions with Tc-99, U, and I-129. In particular, the high concentrations of nitrate from the acidic waste may increase the formation of reactive oxygen species (ROS) that impact both degradation of NOM and behavior of contaminants. In the presence of sunlight, I-129, Tc-99, and U speciation and complexation behavior may be affected by ROS and NOM degradation products in addition to the factors generally considered in subsurface systems in the absence of light. This research aims to determine whether the interactions between radionuclides, NOM, and nitrate affect the fate of I-129, Tc-99, and U and which processes are controlling their behavior. Experiments were conducted at variable pH in the presence of NaNO{sub 3} in order to determine the impact of light and pH on NOM degradation and to evaluate the impact on the fate of contaminants of concern. Soil samples high in NOM collected from two sites in the Southeastern United States (Savannah River Site and the Everglades) were studied. Batch experiments were conducted with NOM and the following aqueous contaminants, U, I-129, Tc-99 with exposure to ultraviolet (UV) light in an environmental chamber. This study was conducted in a sterile environment in order to exclude the potential for microbial degradation of organic matter. Results indicated photodegradation of NOM and significant interaction of radionuclides with NOM. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measuring the electron temperature and identifying plasma detachment using machine learning and spectroscopy

A machine learning approach has been implemented to measure the electron temperature directly from the emission spectra of a tokamak plasma. This approach utilized a neural network (NN) trained on a dataset of 1865 time slices from operation of the DIII-D tokamak using extreme ultraviolet/vacuum ultraviolet emission spectroscopy matched with high-accuracy divertor Thomson scattering measurements of the electron temperature, T e . This NN is shown to be particularly good at predicting T e at low temperatures (T e < 10 eV) where the NN demonstrated a mean average error of less than 1 eV. Trained to detect plasma detachment in the tokamak divertor, a NN classifier was able to correctly identify detached states (T e < 5 eV) with a 99% accuracy (an F 1 score of 0.96) at an acquisition rate 10× faster than the Thomson scattering measurement. The performance of the model is understood by examining a set of 4800 theoretical spectra generated using collisional radiative modeling that was also used to predict the performance of a low-cost spectrometer viewing nitrogen emission in the visible wavelengths. Furthermore, these results provide a proof-of-principle that low-cost spectrometers leveraged with machine learning can be used to boost the performance of more expensive diagnostics on fusion devices and be used independently as a fast and accurate T e measurement and detachment classifier.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Multiwavelength Look at the GJ 9827 System: No Evidence of Extended Atmospheres in GJ 9827b and d from HST and CARMENES Data

GJ 9827 is a bright star hosting a planetary system with three transiting planets. As a multiplanet system with planets that sprawl within the boundaries of the radius gap between terrestrial and gaseous planets, GJ 9827 is an optimal target to study the evolution of the atmospheres of close-in planets with a common evolutionary history and their dependence from stellar irradiation. Here we report on the Hubble Space Telescope (HST) and CARMENES transit observations of GJ 9827 planets b and d. We performed a stellar and ISM characterization from the ultraviolet HST spectra, obtaining fluxes for Lyα and Mg ii of F(Lyα) = (5.42{sub −0.75}{sup +0.96}) × 10{sup −13} erg cm{sup −2} s{sup −1} and F(Mgii) = (5.64 ± 0.24) × 10{sup −14} erg cm{sup −2} s{sup −1}. We also investigated a possible absorption signature in Lyα in the atmosphere of GJ 9827b during a transit event from HST spectra, as well as Hα and He i signature for the atmosphere of GJ 9827b and d from CARMENES spectra. We found no evidence of an extended atmosphere in either of the planets. This result is also supported by our analytical estimations of mass loss based on the measured radiation fields for all three planets of this system, which led to a mass-loss rate of 0.4, 0.3, and 0.1 planetary masses per Gyr for GJ 9827b, c, and d, respectively. These values indicate that the planets could have lost their volatiles quickly in their evolution and probably do not retain an atmosphere at the current stage.

47 OTHER INSTRUMENTATION↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Dynamics of Product Branching from Radical Intermediates in Elementary Combustion Reactions (Final Technical Report)

While the total rate constant for many elementary reactions is well-characterized, understanding the product branching in complex reactions presents a formidable challenge. To gain an incisive probe of such reactions, our experiments investigate the dynamics of the product channels that arise from transient radical intermediates along the bimolecular reaction coordinates. Our recent published work uses the methodology developed in my group in the last fifteen years, using both imaging and scattering apparatuses. The experiments generate a particular isomeric form of an unstable radical intermediate along a bimolecular reaction coordinate and study the branching between the ensuing product channels of the energized radical as a function of its internal rotational and vibrational energy under collision-less conditions. The experiments use a combination of: 1) measurement of product velocity and angular distributions in a crossed laser-molecular beam apparatus, with electron bombardment detection in my lab in Chicago or 2) with tunable vacuum ultraviolet photoionization detection at Taiwan's National Synchrotron Radiation Research Center (NSRRC), and 3) velocity map imaging using state-selective REMPI and single photon VUV ionization of radical intermediates and reaction products. We also employ tunable VUV photoionization detection in our imaging apparatus, using difference frequency four-wave mixing to produce photoionization light tunable from 8 to 10.8 eV. This year of support funded our work to photolytically generate the radical intermediate important in the OH + propene reaction when OH adds to an end carbon. Our other major result this past year was on the photoionization detection of vinoxy radicals. Our experiments at the NSRRC definitively show that vinoxy dissociatively ionizes to both CH 3 + and HCO + , and establishes the absolute partial photoionization cross section of vinoxy to CH 3 + at 10.5 and 11.44 eV. This should allow experimentalists detecting vinoxy radicals produced in bimolecular reactions such as OH + propene to get good branching fractions to that product channel. Finally we initiated studies of the photodissociation of 1-bromo-2-chloroethane and 1,1-bromochloroethane at 193 nm at the NSRRC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗