Undulator Radiation Damage Experience at LCLS

The SLAC National Accelerator Laboratory has been running the Linac Coherent Light Source (LCLS), the first x-ray Free Electron Laser since 2009. Undulator magnet damage from radiation, produced by the electron beam traveling through the 133-m long straight vacuum tube, has been and is a concern. A damage measurement experiment has been performed in 2007 in order to obtain dose versus damage calibrations. Radiation reduction and detection devices have been integrated into the LCLS undulator system. The accumulated radiation dose rate was continuously monitored and recorded. In addition, undulator segments have been routinely removed from the beamline to be checked for magnetic (50 ppm, rms) and mechanic (about 0.25 µm, rms) changes. A reduction in strength of the undulator segments is being observed, at a level, which is now clearly above the noise. Recently, potential sources for the observed integrated radiation levels have been investigated. The paper discusses the results of these investigation as well as comparison between observed damage and measured dose accumulations and discusses, briefly, strategies for the new LCLS-II upgrade, which will be operating at more than 300 times larger beam rate.

43 PARTICLE ACCELERATORS↗

DEVELOPMENT OF SHORT UNDULATORS FOR ELECTRON-BEAM-RADIATION INTERACTION STUDIES

Interaction of an electron beam with external field or its own radiation has widespread applications ranging from coherent-radiation generation, phase space cooling or formation of temporally-structured beams. An efficient coupling mechanism between an electron beam and radiation field relies on the use of a magnetic undulator. In this contribution we detail our plans to build short (11-period) undulators with 7-cm period refurbishing parts of the aladdin U3 undulator [1]. Possible use of these undulators at available test facilities to support experiments relevant to cooling techniques and radiation sources are outlined.

43 PARTICLE ACCELERATORS↗

Simulation Study of the Helical Superconducting Undulator Installation at the Advanced Photon Source

A helical superconducting undulator is planned for installation at the APS. Such an installation would be first of its kind – helical devices were never installed in synchrotron light sources before. Due to its reduced horizontal aperture, a lattice modification is required to accommodate for large horizontal oscillations during injection. We describe the lattice change details and show the new lattice experimental test results. To understand the effect of the undulator on single-particle dynamics, first, its kick maps were computed using different methods. We have found that often-used Elleaume formula* for kick maps gives wrong results for this undulator. We then used the kick maps obtained by other methods to simulate the effect of the undulator on injection and lifetime.

Sajaev, V.↗

Start-to-end global imaging as a sunward propagating, SAPS-associated giant undulation event

We present high-time resolution global imaging of a sunward propagating giant undulation event from start to finish. The event occurred on November 24, 2001 during a very disturbed storm interval. The giant undulations began to develop at around 13UT and persisted for approximately 2 hours. The sunward propagation speed was on the order of 0.6 km/s (relative to SM coordinate system). The undulations had a wavelength of {approx} 750 km, amplitudes of {approx} 890 km and produced ULF pulsations on the ground with a period of {approx} 1108s. We show that the undulations were associated with SAPs flows that were caused by the proton plasma sheet penetrating substantially farther Earthward than the electron plasma sheet on the duskside. The observations appear to be consistent with the development of a shear flow and/or ballooning type of instability at the plasmapause driven by intense SAPS-associated shear flows.

79 ASTRONOMY AND ASTROPHYSICS↗

UNDULATOR-BASED LASER WAKEFIELD ACCELERATOR ELECTRON BEAM DIAGNOSTIC

to couple the THUNDER undulator to the LOASIS Lawrence Berkeley National Laboratory (LBNL) laser wakefield accelerator (LWFA). Currently the LWFA has achieved quasi-monoenergetic electron beams with energies up to 1 GeV. These ultra-short, high-peak-current, electron beams are ideal for driving a compact XUV free electron laser (FEL). Understanding the electron beam properties such as the energy spread and emittance is critical for achieving high quality light sources with high brightness. By using an insertion device such as an undulator and observing changes in the spontaneous emission spectrum, the electron beam energy spread and emittance can be measured with high precision. The initial experiments will use spontaneous emission from 1.5 m of undulator. Later experiments will use up to 5 m of undulator with a goal of a high gain, XUV FEL.

43 PARTICLE ACCELERATORS↗

Tapered helical undulator system for high efficiency energy extraction from a high brightness electron beam

In this work we discuss the design choices and construction strategy of the tapered undulator system designed for a high energy extraction efficiency experiment in the ultraviolet region of the electromagnetic spectrum planned for installation at the Argonne National Laboratory Linac Extension Area (LEA) beamline. The undulator is comprised of 4 sections pure permanent magnet Halbach array separated by short break sections, each one of them housing a focusing quadrupole doublet and a phase shifter. The quadrupoles use a novel hybrid design which allows one to vary the gradient and match the beam transversely. Finally, the undulator tapering profile is optimized to maximize the energy conversion efficiency from a 340 MeV 1 kA beam into coherent 257.5 nm radiation taking into account the longitudinal current profile generated by the linac.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Analysis of a Helical Superconducting Undulator Cryostat

A novel cryocooler-cooled helical superconducting undulator (HSCU) was built and installed in the Advanced Photon Source (APS) storage ring and has been in operation since January 2018. The new cryostat for the HSCU is a major improvement of the cryogenic system used for the existing APS planar superconducting undulators. In both systems, superconducting magnets are cooled independently from the beam chamber by liquid helium (LHe) passing through a channel in the magnet/mold assembly. The original planar undulator cryostat consists of three thermal circuits: the outer shield circuit to cool both the warm part of the magnet current leads and the outer shield, the beam chamber cooling circuit to cool the beam chamber and the inner shield, and the magnet cooling circuit to cool the magnets and the LHe tank. On the other hand, the new system consists of only two thermal circuits: the thermal shield circuit to cool the beam chamber, the shield, and the warm part of the magnet leads; and the magnet cooling circuit to cool the LHe tank and the magnet/mold assembly. An finite element analysis-based thermal model of the new HSCU cryostat was developed while the cryogenic performance of the HSCU was measured in a series of standalone tests as well as after installation in the storage ring. This paper presents a thermal analysis of the new HSCU cryostat and, in particular, a comparison of calculated and measured temperatures as well as the excess cooling capacity of the new cryostat in static and dynamic (beam-induced heating) modes.

cryocooler↗

Resistive Wall Heating of the Undulator in High Repetition Rate

In next generation high repetition rate FELs, beam energy loss due to resistive wall wakefields will produce significant amount of heat. The heat load for a superconducting undulator (operating at low temperature), must be removed and will be expensive to remove. In this paper, we study this effect in an undulator proposed for a Next Generation Light Source (NGLS) at LBNL. We benchmark our calculations with measurements at the LCLS and carry out detailed parameter studies using beam from a start-to-end simulation. Our preliminarym results suggest that the heat load in the undulator is about 2 W/m or lower with an aperture size of 6 mm for nominal NGLS preliminary design parameters.

43 PARTICLE ACCELERATORS↗

Controlling beam trajectory and transport in a tapered helical undulator

In this paper we present a detailed discussion of the helical undulator system developed for high extraction efficiency experiments in the tapered-enhanced stimulated superradiant amplification regime. The design is based on permanent magnet technology and comprises two Halbach arrays orthogonally oriented and shifted by 90° with respect to each other. When used in low energy beamlines for THz generation, the electron beam trajectory and transport are particularly sensitive to the undulator off-axis fields so that it becomes important to complement on-axis field measurements with analysis and tuning of the higher-order field components. Here we describe how the pulsed wire measurement technique can be effectively used to retrieve on- and off-axis magnetic field characteristics of the undulator. A simple two-dipole model is developed to guide the final adjustments to the permanent magnet positions along the array to tune the quadrupole and sextupole components of the field.

free-electron lasers↗

Fabrication and Testing of 18-mm-Period, 0.5-m-Long Nb 3 Sn Superconducting Undulator

The Advanced Photon Source at Argonne National Laboratory, in collaboration with FNAL and LBNL, is developing a Nb 3 Sn superconducting undulator with the goal of installing this device on the APS storage ring and providing APS users with the novel radiation source. A series of short, similar to ~ 8-cm-long, 18-mm-period undulator prototype magnets have been designed, fabricated, and tested. The same design was scaled to fabricate a 0.5-m-long undulator prototype. Tests of this prototype showed that the designed peak magnetic field of 1.2 T at 850 A was successfully achieved. It represents at least a 20% improvement in comparison with a NbTi SCU having the same period and magnetic gap. Test results and lessons learned from the design process are reported here.

43 PARTICLE ACCELERATORS↗

Multicascade X-Ray Free-Electron Laser with Harmonic Multiplier and Two-Frequency Undulator

The feasibility of generation of powerful x-ray radiation by a cascade free-electron laser (FEL) with amplification of higher harmonics using a two-frequency undulator is studied. To analyze the FEL operation, a complex phenomenological single-pass FEL model is developed and used. It describes linear and nonlinear generation of harmonics in the FEL with seed laser that takes into account initial electron beam noise and describes all main losses of each harmonic in each FEL cascade. The model is also calibrated against and approved by the experimental FEL data and available results of three-dimensional numerical simulation. The electron beam in the undulator is assumed to be matched and focused, and the dynamics of power in the singlepass FEL with cascade harmonic multipliers is investigated to obtain x-ray laser radiation in the FEL having the shortest length, beam energy, and frequency of the seed laser as low as possible. In this context, the advantages of the two-frequency undulator used for generation of harmonics are demonstrated. The evolution of harmonics in a multicascade FEL with multiplication of harmonics is investigated. The operation of the cascade FEL at the wavelength λ = 1.14 nm, generating ~30 MW already on 38 m with the seed laser operating at a wavelength of 11.43 nm corresponding to the maximal reflectivity of the multilayered mirror MoRu/Be coating is investigated. In addition, the operation of the multicascade FEL with accessible seed UVlaser operating at a wavelength of 157 nm (F2 excimer UV-laser) and electron beam with energy of ~0.5 GeV is investigated. X-ray radiation simulated in it at the wavelength λ ~ 3.9 nm reaches power of ~50 MW already at ~27 m, which is by two orders of magnitude shorter than 3.4 km of the x-ray FEL recently put into operation in Europe.

43 PARTICLE ACCELERATORS↗

Undulator radiation in a periodic magnetic field with a constant component

We present an analytical investigation of radiation emitted by an electron moving in a planar undulator with a constant magnetic field component added to the periodic one. In order to calculate the spectrum and angular distribution of radiation, we use the technique of generalized Bessel functions. In particular, this method is effectively applied for the study of the influence of the constant magnetic field on the undulator radiation emitted both along and off its axis. The analytical formulation of the effect of the weak constant field enables us to estimate its critical magnitude that may produce a significant distortion in the undulator radiation distributions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring The Source Brilliance at An Undulator Beamline

Third-generation X-ray synchrotrons like the European Synchrotron Radiation Facility (ESRF) are optimized to produce intense undulator radiation. Insertion devices, such as undulators, ensure the highest possible brilliance--the key parameter for the success of e.g. coherent scattering, which is one of the main techniques employed at ESRF's TROIKA beamline. Nowadays, the constant efforts to reduce the emittance and improve the stability of the electron beam allow using small-gap insertion devices and increase the brilliance. Obviously, it is important to have an experimental technique for evaluating the performance of the undulator source. Here we present a method based on measuring the diffuse scattering from a light amorphous material by a photon counting detector. The measured spectral intensities show a very good agreement with the simulated spectra, demonstrating the high brilliance (above 10{sup 20} ph/s/0.1%bw/mrad{sup 2}/mm{sup 2}) achieved at modern facilities.

43 PARTICLE ACCELERATORS↗

Plasma wave undulator for laser-accelerated electrons

Laser-plasma accelerators have become compact sources of ultrashort electron bunches at energies up to the gigaelectronvolt range thanks to the remarkable progress made over the past decade. A direct application of these electron bunches is the production of short pulse x-ray radiation sources. In this letter, we study a fully optically driven x-ray source based on the combination of a laser-plasma accelerator and a plasma wave undulator. The longitudinal electric field of a laser-generated plasma wave is used to wiggle electrons transversally. The period of this plasma undulator being equal to the plasma wavelength, tunable photon energies in the 10 keV range can be achieved with electron energies in the 100-200 MeV range. Considering a 10s TW class femtosecond laser system, undulators with a strength parameter K{approx}0.5 and with about ten periods can be combined with a laser-plasma accelerator, resulting in several 10{sup -2} emitted x-ray photons per electron.

43 PARTICLE ACCELERATORS↗

Negative-mass mitigation of Coulomb repulsion for terahertz undulator radiation of electron bunches

It is proposed to utilize the effect of negative mass for stabilization of the effective axial size of very dense and short electron bunches produced by photo-injector guns by using combined undulator and strong uniform magnetic fields. It has been shown that in the “abnormal” regime, an increase in the electron energy leads to a decrease in the axial velocity of the electron; due to the negative-mass effect, the Coulomb repulsion of electrons leads to their attraction and formation of a fairly stable and compact bunch “nucleus.” An undulator with a strong uniform magnetic field providing the negative-mass effect is designed for an experimental source of terahertz radiation. The use of the negative-mass regime in this experiment should result in a long-pulse coherent spontaneous undulator emission from a short dense moderately relativistic (5.5 MeV) photo-injector electron bunch with a high (up to 20%) efficiency and a narrow frequency spectrum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generation of a wakefield undulator in plasma with transverse density gradient

Here, we show that a short relativistic electron beam propagating in a plasma with a density gradient perpendicular to the direction of motion generates a wakefield in which a witness bunch experiences a transverse force. A density gradient oscillating along the beam path would create a periodically varying force$-$an undulator, with an estimated strength of the equivalent magnetic field more than ten Tesla. This opens an avenue for creation of a high-strength, short-period undulators, which eventually may lead to all-plasma, free electron lasers where a plasma wakefield acceleration is naturally combined with a plasma undulator in a unifying, compact setup.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectrum-Based Alignment of In-Vacuum Undulators in a Low-Emittance Storage Ring

In-vacuum undulators (IVU) are used extensively at light source facilities, in particular at medium-energy storage rings, where these devices are the main sources of high-brightness hard X-rays. The relatively small vertical magnetic gaps that are used in these planar undulators make them rather sensitive to misalignments of magnet arrays with respect to the electron orbit in the vertical plane. Based on commissioning results of undulator-based hard X-ray beamlines at the National Synchrotron Light Source II (NSLS-II)—a Department of Energy Office of Science User Facility at Brookhaven National Laboratory— IVU misalignment was found to be the most frequent cause of spectral “underperformance.” It is possible, nevertheless, to restore the performance using a spectrum-based IVU alignment procedure described in this article.

47 OTHER INSTRUMENTATION↗

Thermal Analysis of a Superconducting Undulator Cryostat for the APS Upgrade

The Advanced Photon Source Upgrade includes four 4.8-m-long superconducting undulator (SCU) cryostats, each containing two planar undulator NbTi magnets up to 1.9 m long. The cooling is provided by six cryocoolers arranged in three thermal circuits. The magnets are indirectly cooled with LHe penetrating through channels in the magnet cores. This 4 K circuit, which also includes a LHe tank, is cooled by five 4 K cryocooler 2nd stages. A beam vacuum, which is thermally isolated from the magnets, is cooled by one 10 K cryocooler 2nd stage. A thermal shield and warm parts of current leads are cooled by the 1st stages of all six cryocoolers. This paper presents an ANSYS-based thermal analysis of the new SCU cryostat including all thermal circuits. The benchmarked thermal conductance between the cryocooler cold heads and the LHe tank are used in the calculations as well as the measured cryocooler load lines. The model predicts temperatures in the system, total 4 K heat loads, and excess cooling power for various operational modes of the undulator.