Search NASA⌕ Search

SEARCH · Search NASA

Results for “uniform methods project”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Encapsulation task of the low-cost silicon solar array project. Investigation of test methods, material properties, and processes for solar cell encapsulants

The results of an investigation of solar module encapsulation systems applicable to the Low-Cost Solar Array Project 1986 cost and performance goals are presented. Six basic construction elements were identified and their specific uses in module construction defined. A uniform coating basis was established for each element. The survey results were also useful in revealing price ranges for classes of materials and estimating the cost allocation for each element within the encapsulating cost goal. The six construction elements were considered to be substrates, superstrates, pottants, adhesives, outer covers and back covers.

Willis, P. B.↗

An algorithm for efficient metal artifact reductions in permanent seed implants

Purpose: In permanent seed implants, 60 to more than 100 small metal capsules are inserted in the prostate, creating artifacts in x-ray computed tomography (CT) imaging. The goal of this work is to develop an automatic method for metal artifact reduction (MAR) from small objects such as brachytherapy seeds for clinical applications. Methods: The approach for MAR is based on the interpolation of missing projections by directly using raw helical CT data (sinogram). First, an initial image is reconstructed from the raw CT data. Then, the metal objects segmented from the reconstructed image are reprojected back into the sinogram space to produce a metal-only sinogram. The Steger method is used to determine precisely the position and edges of the seed traces in the raw CT data. By combining the use of Steger detection and reprojections, the missing projections are detected and replaced by interpolation of non-missing neighboring projections. Results: In both phantom experiments and patient studies, the missing projections have been detected successfully and the artifacts caused by metallic objects have been substantially reduced. The performance of the algorithm has been quantified by comparing the uniformity between the uncorrected and the corrected phantom images. The results of the artifact reduction algorithm are indistinguishable from the true background value. Conclusions: An efficient algorithm for MAR in seed brachytherapy was developed. The test results obtained using raw helical CT data for both phantom and clinical cases have demonstrated that the proposed MAR method is capable of accurately detecting and correcting artifacts caused by a large number of very small metal objects (seeds) in sinogram space. This should enable a more accurate use of advanced brachytherapy dose calculations, such as Monte Carlo simulations.

60 APPLIED LIFE SCIENCES↗

A solid iodinated phantom material for use in tomographic x-ray imaging

PURPOSE: Iodinated phantoms are of value in x-ray imaging for quality control measurements, system calibration, and for use in the research setting; however, the liquid phantoms that are most often used have several limitations including variability between repeated dilutions, inhomogeneities from air bubbles or precipitants, and long set up times. Although suitable materials have been investigated for projection radiography, quantitative measurements of contrast enhancement in computed tomography (CT) have become increasingly important in the clinic, and a need exists for a durable and reproducible iodinated phantom material. In this work, the authors describe a solid radiographic phantom material that has an accurately known concentration of iodine distributed uniformly throughout its volume and that has stable properties over time. This material can be molded or machined into a desired shape to create a test object or for use in an anthropomorphic phantom. Methods: Two sets of calibration phantoms were produced with a clinically relevant range of iodine concentrations. Measurements were made on these phantoms to characterize the material properties in terms of accuracy of iodine concentration, radiographic uniformity, temporal stability of x-ray attenuation, and manufacturing repeatability. Experimentally measured linear x-ray attenuation coefficients were compared to those predicted by a theoretical model. The uniformity of the iodine distribution in the material was assessed by measuring image intensity variation, both in projection images and in reconstructed CT volumes. The reproducibility of manufacture was estimated on a set of independently produced samples. A longitudinal study was performed to assess the stability of the material x-ray characteristics over time by making measurements at 6 month intervals. Results: Good agreement was seen between the experimental measurements of effective attenuation and the theoretically predicted values. It is estimated that a desired iodine concentration could be produced to within 0.04 mg/ml. Comparison of the measured effective linear iodine attenuation coefficients of eight 1.0 mg/ml samples indicated a manufacturing reproducibility of {+-}0.03 mg/ml iodine. Variations in uniformity across each of the samples were on the order of image intensity fluctuations ({sigma}). No inhomogeneities due to mixing or settling were apparent. An analysis of longitudinal data collected for both calibration sets revealed no perceptible change in radiographic properties over the first 6 months after manufacture, nor over a subsequent 1.5 yr period from 1 yr postmanufacture onward. Conclusions: The uniformity, stability, and precision of this iodinated material suggest that it is suitable for use in accurate calibration tools for contrast tomographic imaging.

36 MATERIALS SCIENCE↗

Projection of two-dimensional diffusion in narrow asymmetric channels onto the longitudinal direction

Diffusive transport of particles is a ubiquitous feature of physical, chemical and biological systems. Typical structures like pores, tubes or fibers, are quasi one-dimensional, such that we need to solve 2+1 or 3+1 dimensional differential equations to describe correctly transport along them. The so-called Fick-Jacobs approach dramatically simplifies the problem if one assumes that a solute distribution in any cross-section of the channel is uniform at equilibrium. That study focuses on the mapping of the diffusion equation in a two-dimensional narrow asymmetric channel of varying cross section onto the longitudinal coordinate. We present a generalization to the case of an asymmetric channel using the projection method introduced earlier by Kalinay and Percus. We derive an expansion of the effective diffusion coefficient, which represents corrections to the Fick-Jacobs equation and contains the well-known previous results as special cases. Finally, we study numerically some specific two-dimensional asymmetric channel configurations to test and show the broader applicability of this effective diffusion coefficient formula.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of a variable dose acquisition technique for microcalcification and mass detection in digital breast tomosynthesis

In this article the authors evaluate a recently proposed variable dose (VD)-digital breast tomosynthesis (DBT) acquisition technique in terms of the detection accuracy for breast masses and microcalcification (MC) clusters. With this technique, approximately half of the total dose is used for one center projection and the remaining dose is split among the other tomosynthesis projection views. This acquisition method would yield both a projection view and a reconstruction view. One of the aims of this study was to evaluate whether the center projection alone of the VD acquisition can provide equal or superior MC detection in comparison to the 3D images from uniform dose (UD)-DBT. Another aim was to compare the mass-detection capabilities of 3D reconstructions from VD-DBT and UD-DBT. In a localization receiver operating characteristic (LROC) observer study of MC detection, the authors compared the center projection of a VD acquisition scheme (at 2 mGy dose) with detector pixel size of 100 {mu}m with the UD-DBT reconstruction (at 4 mGy dose) obtained with a voxel size of 100 {mu}m. MCs with sizes of 150 and 180 {mu}m were used in the study, with each cluster consisting of seven MCs distributed randomly within a small volume. Reconstructed images in UD-DBT were obtained from a projection set that had a total of 4 mGy dose. The current study shows that for MC detection, using the center projection alone of VD acquisition scheme performs worse with area under the LROC curve (A{sub L}) of 0.76 than when using the 3D reconstructed image using the UD acquisition scheme (A{sub L}=0.84). A 2D ANOVA found a statistically significant difference (p=0.038) at a significance level of 0.05. In the current study, although a reconstructed image was also available using the VD acquisition scheme, it was not used to assist the MC detection task which was done using the center projection alone. In the case of evaluation of detection accuracy of masses, the reconstruction with VD-DBT (A{sub L}=0.71) was compared to that obtained from the UD-DBT (A{sub L}=0.78). The authors found no statistically significant difference between the two (p-value=0.22), although all the observers performed better for UD-DBT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Proton dose calculation on scatter-corrected CBCT image: Feasibility study for adaptive proton therapy

Purpose: To demonstrate the feasibility of proton dose calculation on scatter-corrected cone-beam computed tomographic (CBCT) images for the purpose of adaptive proton therapy. Methods: CBCT projection images were acquired from anthropomorphic phantoms and a prostate patient using an on-board imaging system of an Elekta infinity linear accelerator. Two previously introduced techniques were used to correct the scattered x-rays in the raw projection images: uniform scatter correction (CBCT{sub us}) and a priori CT-based scatter correction (CBCT{sub ap}). CBCT images were reconstructed using a standard FDK algorithm and GPU-based reconstruction toolkit. Soft tissue ROI-based HU shifting was used to improve HU accuracy of the uncorrected CBCT images and CBCT{sub us}, while no HU change was applied to the CBCT{sub ap}. The degree of equivalence of the corrected CBCT images with respect to the reference CT image (CT{sub ref}) was evaluated by using angular profiles of water equivalent path length (WEPL) and passively scattered proton treatment plans. The CBCT{sub ap} was further evaluated in more realistic scenarios such as rectal filling and weight loss to assess the effect of mismatched prior information on the corrected images. Results: The uncorrected CBCT and CBCT{sub us} images demonstrated substantial WEPL discrepancies (7.3 ± 5.3 mm and 11.1 ± 6.6 mm, respectively) with respect to the CT{sub ref}, while the CBCT{sub ap} images showed substantially reduced WEPL errors (2.4 ± 2.0 mm). Similarly, the CBCT{sub ap}-based treatment plans demonstrated a high pass rate (96.0% ± 2.5% in 2 mm/2% criteria) in a 3D gamma analysis. Conclusions: A priori CT-based scatter correction technique was shown to be promising for adaptive proton therapy, as it achieved equivalent proton dose distributions and water equivalent path lengths compared to those of a reference CT in a selection of anthropomorphic phantoms.

60 APPLIED LIFE SCIENCES↗

Existing evidence on the effects of climate variability and climate change on ungulates in North America: a systematic map

Abstract Background Climate is an important driver of ungulate life-histories, population dynamics, and migratory behaviors. Climate conditions can directly impact ungulates via changes in the costs of thermoregulation and locomotion, or indirectly, via changes in habitat and forage availability, predation, and species interactions. Many studies have documented the effects of climate variability and climate change on North America’s ungulates, recording impacts to population demographics, physiology, foraging behavior, migratory patterns, and more. However, ungulate responses are not uniform and vary by species and geography. Here, we present a systematic map describing the abundance and distribution of evidence on the effects of climate variability and climate change on native ungulates in North America. Methods We searched for all evidence documenting or projecting how climate variability and climate change affect the 15 ungulate species native to the U.S., Canada, Mexico, and Greenland. We searched Web of Science, Scopus, and the websites of 62 wildlife management agencies to identify relevant academic and grey literature. We screened English-language documents for inclusion at both the title and abstract and full-text levels. Data from all articles that passed full-text review were extracted and coded in a database. We identified knowledge clusters and gaps related to the species, locations, climate variables, and outcome variables measured in the literature. Review findings We identified a total of 674 relevant articles published from 1947 until September 2020. Caribou ( Rangifer tarandus ), elk ( Cervus canadensis ), and white-tailed deer ( Odocoileus virginianus ) were the most frequently studied species. Geographically, more research has been conducted in the western U.S. and western Canada, though a notable concentration of research is also located in the Great Lakes region. Nearly 75% more articles examined the effects of precipitation on ungulates compared to temperature, with variables related to snow being the most commonly measured climate variables. Most studies examined the effects of climate on ungulate population demographics, habitat and forage, and physiology and condition, with far fewer examining the effects on disturbances, migratory behavior, and seasonal range and corridor habitat. Conclusions The effects of climate change, and its interactions with stressors such as land-use change, predation, and disease, is of increasing concern to wildlife managers. With its broad scope, this systematic map can help ungulate managers identify relevant climate impacts and prepare for future changes to the populations they manage. Decisions regarding population control measures, supplemental feeding, translocation, and the application of habitat treatments are just some of the management decisions that can be informed by an improved understanding of climate impacts. This systematic map also identified several gaps in the literature that would benefit from additional research, including climate effects on ungulate migratory patterns, on species that are relatively understudied yet known to be sensitive to changes in climate, such as pronghorn ( Antilocapra americana ) and mountain goats ( Oreamnos americanus ), and on ungulates in the eastern U.S. and Mexico.

Malpeli, Katherine C. (ORCID:000000030780918X)↗

Influence of Thermally-Grown Oxide (TGO) Layer on the Driving Forces Associated with Failure in Environmental Barrier Coating (EBC) Systems

Environmental barrier coatings (EBC) is an enabling technology for the successful application of ceramic matrix composites (CMCs) in air-breathing gas turbine engines. Spallation of environmental barrier coating (EBC) induced by thermally grown oxide (TGO) layer is a key EBC failure mode. The TGO layer, resulting from steam oxidation, grows either from a silicon bond coat layer (if present) or from the silicon carbide (SiC) based substrate itself. Critical thickness of the TGO layer for failure is in the range of 20-30 microns but it can vary due to exposure temperature, microstructure etc. Current work at NASA Glenn Research Center, under the Revolutionary Tools and Methods (RTM) project is aimed at addressing associated failure modes in EBC systems and developing robust analysis tools to aid in the design/analysis of these systems. The objective of the current work is to conduct a sensitivity study to examine the influence of uniformly and non-uniformly grown oxide layers with or without damage on the associated driving forces leading to spallation of the EBC when subjected to isothermal loading. Initial results indicate that the presence of damage (vertical cracks caused by in-plane stresses) enhances the stresses that are present due to non-uniformity. However, the presence of non-uniformity itself is still the main factor influencing the magnitude of peel and shear stresses in the TGO layer.

Mital, Subodh K.↗

Accretion rates of protoplanets

Projections are made of the collision/accretion rates of planetesimals in a uniform surface-density disk with a massive protoplanet, whose collision cross-section is enhanced, relative to its geometric cross-section, by a gravitational focusing of the planetesimals' trajectories. A scaling method is presented which generalizes the results obtained to protoplanets of arbitrary mass, radius, and orbital semimajor axis. It is established that, in the case where one protoplanet dominates gravitational scattering in a given protoplanetary disk region, planetesimal inclinations are substantially less rapidly excited than eccentrocities; the skewed velocity dispersion thus generated allows for a more rapid rate of protoplanet growth.

Greenzweig, Yuval↗

Launch Pad Coatings for Smart Corrosion Control

Corrosion is the degradation of a material as a result of its interaction with the environment. The environment at the KSC launch pads has been documented by ASM International (formerly American Society for Metals) as the most corrosive in the US. The 70 tons of highly corrosive hydrochloric acid that are generated by the solid rocket boosters during a launch exacerbate the corrosiveness of the environment at the pads. Numerous failures at the pads are caused by the pitting of stainless steels, rebar corrosion, and the degradation of concrete. Corrosion control of launch pad structures relies on the use of coatings selected from the qualified products list (QPL) of the NASA Standard 5008A for Protective Coating of Carbon Steel, Stainless Steel, and Aluminum on Launch Structures, Facilities, and Ground Support Equipment. This standard was developed to establish uniform engineering practices and methods and to ensure the inclusion of essential criteria in the coating of ground support equipment (GSE) and facilities used by or for NASA. This standard is applicable to GSE and facilities that support space vehicle or payload programs or projects and to critical facilities at all NASA locations worldwide. Environmental regulation changes have dramatically reduced the production, handling, use, and availability of conventional protective coatings for application to KSC launch structures and ground support equipment. Current attrition rate of qualified KSC coatings will drastically limit the number of commercial off the shelf (COTS) products available for the Constellation Program (CxP) ground operations (GO). CxP GO identified corrosion detection and control technologies as a critical, initial capability technology need for ground processing of Ares I and Ares V to meet Constellation Architecture Requirements Document (CARD) CxP 70000 operability requirements for reduced ground processing complexity, streamlined integrated testing, and operations phase affordability. Researchers at NASA's Corrosion Technology Laboratory at KSC are developing a smart, environmentally friendly coating system for early corrosion detection, inhibition, and self healing of mechanical damage without external intervention. This smart coating will detect and respond actively to corrosion and mechanical damage such as abrasion and scratches, in a functional and predictable manner, and will be capable of adapting its properties dynamically. This coating is being developed using corrosion sensitive microcapsules that deliver the contents of their core (corrosion inhibiting compounds, corrosion indicators, and self healing agents) on demand when corrosion or mechanical damage to the coating occurs.

Calle, Luz M.↗

An approach to multiobjective optimization of rotational therapy

Multiobjective optimization is used in radiotherapy, especially IMRT, to generate treatment plans which meet different objectives to varying extents. Trade-off surfaces can be constructed representing the gains and losses of different objectives when switching from one plan to another, and the planner can interactively explore different treatment possibilities without the need for reoptimization. In this work a method for the multiobjective optimization of rotational therapy is introduced. The proposed method is applied slice per slice and uses the geometry of the slice directly to construct several arcs, each conformally irradiating the tumor and blocking a number (0,1,2,...) of different organs at risk present in the treatment. The blocked arc dose distributions so obtained are quite inhomogeneous in the target. An algorithm, based on the iterative reconstruction of images from projections, has been developed to compensate for this inhomogeneity, leading to compensated blocked arcs which deliver more uniform target doses but still block critical structures. Different treatments can be obtained as linear combinations of these arcs, each involving different trade-offs among the objectives involved. The compensatory algorithm substantially improves the target dose uniformity of blocked arcs at the cost of slightly increasing the dose to the rest of the body, allowing delivery of good uniform dose distributions to the target without significantly irradiating the blocked organ(s). Trade-off surfaces are presented for slices containing a target and one or two critical structures. The method is directly implementable using axial or helical tomotherapy. Implementation for conventional linear accelerators will be more difficult because the number of arcs needed to deliver such treatments can be large, an issue to be explored in future work.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Performance Piezoelectric MEMS Manufacturing & Application on Micro Power Generators (CRADA Final Report)

This project aimed to develop and characterize a micro-fabrication technology for wafer-scale heterogeneous integration of bulk piezoelectric materials on silicon substrates that could enable manufacturing of high-performance micro transducers. Typical technical challenges for piezoelectric microfabrication technologies are high-temperature processing, non-uniform film quality, and low process repeatability, which will be addressed during this project. Progress was made on preliminary research towards development of a technology platform that will enable a new micro-fabrication process to provide the highest electromechanical coupling among any other thin/thick-film deposition methods available today. This work has tested and characterized samples that we hope will further our goal of refining and enabling existing micro transducers to achieve unprecedentedly high performance. This project focused solely on the characterization of the proposed microfabrication process technology, and it did not consist of design or manufacturing of new transducers, such as sensors, actuators or energy harvesters based on this fabrication process. Future work will be aimed at the research and development of process steps specifically to enable integration of on-chip electronics with piezoelectric materials.

36 MATERIALS SCIENCE↗

An Infrared Study of the Dust Properties and Geometry of the Arched Filaments H ii Region with SOFIA/FORCAST

Massive stellar clusters provide radiation (∼10{sup 7}--10{sup 8} L{sub ⊙}) and winds (∼1000 km s{sup −1}) that act to heat dust and shape their surrounding environment. In this paper, the Arched Filaments in the Galactic center were studied to better understand the influence of the Arches cluster on its nearby interstellar medium (ISM). The Arched Filaments were observed with the Faint Object InfraRed CAMera for the SOFIA Telescope at 19.7, 25.2, 31.5, and 37.1 μm. Color–temperature maps of the region created with the 25.2 and 37.1 μm data reveal relatively uniform dust temperatures (70–100 K) over the extent of the filaments (∼25 pc). Distances between the cluster and the filaments were calculated assuming equilibrium heating of standard-size ISM dust grains (∼0.1 μm). The distances inferred by this method are in conflict with the projected distance between the filaments and the cluster, although this inconsistency can be explained if the characteristic grain size in the filaments is smaller (∼0.01 μm) than typical values. DustEM models of selected locations within the filaments show evidence of depleted abundances of polycyclic aromatic hydrocarbons (PAHs) by factors of ∼1.6–10 by mass compared to the diffuse ISM. The evidence for both PAH depletion and a smaller characteristic grain size points to processing of the ISM within the filaments. We argue that the eroding of dust grains within the filaments is not likely attributable to the radiation or winds from the Arches cluster, but may be related to the physical conditions in the Galactic center.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of Helical Tomotherapy for Partial-Breast Irradiation of Prone-Positioned Patients

Purpose: To investigate whether helical tomotherapy can provide conformal, uniform target-dose coverage for partial-breast irradiation (PBI) of patients positioned prone while achieving organ-at-risk sparing compliant with National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39/Radiation Therapy Oncology Group (RTOG) 0413 guidelines; and to report our initial experience with the delivery of prone-breast PBI treatments using tomotherapy. Methods and Materials: For our pilot study, we generated helical tomotherapy plans upon the images of 10 prone-positioned patients previously treated using conventional techniques. We also generated plans for 4 left-breast prone-positioned PBI patients who were treated using helical tomotherapy, and recalculated the planned sinograms upon the pretreatment megavoltage computed tomographic images. Of the planning target volume (PTV), 95% was prescribed to receive 38.5 Gy, administered twice daily for 5 days. Results: For our pilot study, on average the maximum point dose to the PTV was 41.3 Gy, and 99% or more of the PTV received 90% or more of the prescribed dose. RTOG 0413 dose-volume histogram objectives were fulfilled for all organs at risk except the contralateral breast, which received a maximum point dose as high as 3.2 Gy in 1 case. For the prospective prone-positioned tomotherapy PBI plans, all objectives were met except the contralateral-breast maximum dose, which was 3.7 Gy on average. Dose calculation using the planned sinogram upon the pretreatment megavoltage computed tomographic images indicated consistency with the planned dose distributions. Conclusions: Helical tomotherapy can provide conformal and uniform target-dose coverage simultaneous with adequate sparing of critical structures; in this study only the contralateral breast dose exceeded RTOG 0413 guidelines. Dosimetric results for our 4 prospective patient cases were consistent with those for our 10-case pilot study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Standard random number generation for MBASIC

A machine-independent algorithm is presented and analyzed for generating pseudorandom numbers suitable for the standard MBASIC system. The algorithm used is the polynomial congruential or linear recurrence modulo 2 method. Numbers, formed as nonoverlapping adjacent 28-bit words taken from the bit stream produced by the formula a sub m + 532 = a sub m + 37 + a sub m (modulo 2), do not repeat within the projected age of the solar system, show no ensemble correlation, exhibit uniform distribution of adjacent numbers up to 19 dimensions, and do not deviate from random runs-up and runs-down behavior.

Tausworthe, R. C.↗

Spectral Analysis of Regular Material Point Method and its Application to Study High Pressure Reverse Osmosis Membrane Compaction and Embossing

Material Point Method (MPM) is gaining widespread interest in applied continuum mechanics. The fact that all the continuum properties are stored on the particles (or material points) and the governing equations are solved on these material points makes MPM extremely suited to problems involving severe material deformations, such as crack propagation, soil movement, and fluid flows. Despite its popularity, only a few studies have focused on the numerical properties of MPM. This presentation introduces a global spectral analysis of the regular material point method. Contrary to previous studies, the analysis focuses on the numerical properties of the method in the spectral space. The amplification factor is derived as a function of the non- dimensional wave numbers. It provides insights into the stability and dissipative properties of the method for various CFL and Fourier numbers. The effect of the grid shape functions, number of particles per cell and their locations inside the grid cell are also analyzed. The EXAGOOP MPM solver (https://github.com/NREL/Exagoop.git) is developed at the National Renewable Energy Laboratory as a part of the NAWI UHPRO project and is based on the AMReX framework. A single-level, uniform cartesian grid is used as the background mesh, while the particle class in AMReX is used to manage the material point operations. Linear hat and B-splines are used as grid shape functions, while the time integration is performed using explicit Euler time integration. EXAGOOP is both CPU and GPU compatible and has been demonstrated to work well on multiple compute architectures. The performance of EXAGOOP on various computing architectures is presented along with its application to study compaction and embossing of high-pressure reverse osmosis membranes. The MPM solution accurately reproduces the membrane deformation. The deformed pore size and structure simulated using MPM also agree well with experimental SEM images.

material point method↗

WE-G-207-03: Mask Guided Image Reconstruction (MGIR): A Novel Method for Ultra-Low-Dose 3D and Enhanced 4D Cone-Beam Computer-Tomography

Purpose: Recently, compressed sensing (CS) based iterative reconstruction (IR) method is receiving attentions to reconstruct high quality cone beam computed tomography (CBCT) images using sparsely sampled or noisy projections. The aim of this study is to develop a novel baseline algorithm called Mask Guided Image Reconstruction (MGIR), which can provide superior image quality for both low-dose 3DCBCT and 4DCBCT under single mathematical framework. Methods: In MGIR, the unknown CBCT volume was mathematically modeled as a combination of two regions where anatomical structures are 1) within the priori-defined mask and 2) outside the mask. Then we update each part of images alternatively thorough solving minimization problems based on CS type IR. For low-dose 3DCBCT, the former region is defined as the anatomically complex region where it is focused to preserve edge information while latter region is defined as contrast uniform, and hence aggressively updated to remove noise/artifact. In 4DCBCT, the regions are separated as the common static part and moving part. Then, static volume and moving volumes were updated with global and phase sorted projection respectively, to optimize the image quality of both moving and static part simultaneously. Results: Examination of MGIR algorithm showed that high quality of both low-dose 3DCBCT and 4DCBCT images can be reconstructed without compromising the image resolution and imaging dose or scanning time respectively. For low-dose 3DCBCT, a clinical viable and high resolution head-and-neck image can be obtained while cutting the dose by 83%. In 4DCBCT, excellent quality 4DCBCT images could be reconstructed while requiring no more projection data and imaging dose than a typical clinical 3DCBCT scan. Conclusion: The results shown that the image quality of MGIR was superior compared to other published CS based IR algorithms for both 4DCBCT and low-dose 3DCBCT. This makes our MGIR algorithm potentially useful in various on-line clinical applications. Provisional Patent: UF#15476; WGS Ref. No. U1198.70067US00.

60 APPLIED LIFE SCIENCES↗

AMIP Simulation with the CAM4 Spectral Element Dynamical Core

We evaluate the climate produced by the Community Earth System Model, version 1, running with the new spectral-element atmospheric dynamical core option. The spectral-element method is congured to use a cubed-sphere grid, providing quasi-uniform resolution over the sphere, increased parallel scalability and removing the need for polar filters. It uses a fourth order accurate spatial discretization which locally conserves mass and moist total energy. Using the Atmosphere Model Intercomparison Project protocol, we compare the results from the spectral-element dy- namical core with those produced by the default nite-volume dynamical core and with observations.

CAM-SE↗