Search NASA⌕ Search

SEARCH · Search NASA

Results for “utility costs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Development of an All-Aqueous Thermally Regenerative Redox Flow Battery to Support Fossil Fuel Assets

Low-temperature thermal energy, a largely untapped resource, holds significant promise for large-scale electrical power generation globally. Various stationary sources, including industrial entities and thermal power plants, emit considerable low-temperature heat that currently remains unutilized. This energy is often overlooked because its low temperature renders it unsuitable for efficient power generation using conventional methods. However, current research is exploring diverse technologies capable of converting low-temperature heat into grid-scale power, aiming to enhance grid efficiency, further decarbonization initiatives, and facilitate a shift toward more decentralized power systems. One such innovative technology is the thermally regenerative battery (TRB), noted for its high power and energy densities compared to similar technologies, positioning it as a potential game-changer in power generation. TRBs integrate two scalable and well-established unit operations: a redox flow battery and a distillation column. This integration suggests that once an effective TRB chemistry is established, the pathway to commercialization could be expedited. The copper-based thermally regenerative ammonia battery (Cu aq -TRAB) stands out as the first TRB that circumvents electrodeposition/dissolution reactions, stabilizing Cu(I) and Cu(II) within the electrolyte and maintaining stability of all electroactive species in an aqueous phase. This stabilization has led to improvements in coulombic efficiency, open circuit potential, and copper solubility, thereby enhancing power density, energy density, and overall energy efficiency. Preliminary tests were conducted to determine the effects of various electrolyte species on the performance metrics of the battery, both theoretically and experimentally. These tests revealed that the solubility of copper in the Cu aq -TRAB electrolyte was constrained by the Cu(I)-NH 3 complex. Adjusting the background electrolyte to 5 M NH4Br and the ligand concentration to 4 M NH 3 enabled the copper concentration to reach a maximum of 0.6 M. This modification led to an estimated theoretical maximum energy density of 9.5 Wh L -1 for the Cu aq -TRAB. Additionally, full cell testing indicated a tradeoff between peak power and energy density with varying copper and ammonia concentrations. Increasing the applied current density during discharge linearly raised the average power output, with a minimal reduction in energy density due to a balance between higher ohmic overpotential and reduced time for undesirable ammonia crossover. Furthermore, a comprehensive numerical sensitivity analysis of the complete Cu aq -TRAB system was performed. This analysis aimed to assess how the battery and the distillation column responded to changes in system input parameters, providing insights into optimal research directions for enhancing system performance. The analysis revealed that at room temperature, battery power was significantly more sensitive to ohmic losses than to mass transfer, with reaction rates having minimal impact. This trend continued even at higher temperatures. Also, the thermal energy required for ammonia separation was studied, showing that increased temperatures generally reduced energy requirements, except in low-pressure scenarios above 65 °C. An investigation into membrane performance in the Cu aq -TRAB was undertaken, given the significant impact of ammonia transport control and ohmic losses on system performance. Various membranes were evaluated to identify key performance metrics. Among the tested membranes, Selemion CMVN exhibited the highest performance, with a peak power density of 84 mW cm -2 and average values of 26 ± 6.8 mW cm -2 for power density and 2.9 Wh L -1 for energy density at an applied current density of 50 mA cm -2 . An economic assessment indicated a levelized cost of storage at $410 per MWh under optimal conditions, highlighting the commercial potential of the Cu aq -TRAB when utilizing cost-effective, readily available materials.

25 ENERGY STORAGE↗

Assessing the Interactive Impacts of Energy Efficiency and Demand Response on Power System Costs and Emissions

Utilities are increasingly interested in integrating energy efficiency (EE) and demand response (DR) measures and technologies (as well as other distributed energy resources) as a strategic approach to improve their cost-effectiveness and performance. However, the specific EE and DR features that may be best integrated, the interplay between changing EE and DR resource potential, and resulting utility system impacts are not well understood. We quantify the impacts of EE and DR in isolation and in combination on bulk power system costs and emissions based on changes in generation expansion, transmission expansion, and dispatch patterns. The study methodology mimics utility resource planning and uses more novel techniques to select least-cost generation and transmission capacity from supply-and demand-side resources, as compared to more commonly used utility approaches that only consider supply-side resources. The results identify key EE and DR characteristics affecting each other’s power system value and the most valuable technologies and strategies that can be jointly deployed. We discuss implications for EE and DR cost-effectiveness frameworks, program design, and integrated resource planning.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Disaggregating growth in future retail electricity rates

The retail rate impacts of a number of emerging trends (e.g., rapid deployment of electric vehicles and storage, transmission build-out for large-scale renewables deployment, and grid modernization) are unknown. Importantly, decision-makers are concerned about the potential future rate impacts on energy affordability and equity. We disaggregate the key drivers of retail electricity rates and assess their impacts on future rate growth considering their interactions and uncertainty. Specifically, we develop ranges of future cost growth for a generic investor-owned and vertically-integrated electric utility representing typical cost and operating characteristics. The rate driver growth rate ranges are applied in isolation and jointly to quantify the uncertainty and variability in future retail electricity rates. The results identify what rate drivers and factors may minimize and/or decrease uncertainty in retail rate growth and their linkages to industry trends.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Economic perspective of ethanol and biodiesel coproduction from industrial hemp

Herein, the economics of producing biofuels from an industrial hemp (Cannabis sativa) genotype e 19m96136 was investigated. A lignocellulosic biofuel plant, hourly consuming 85 metric tons of hemp biomass was modeled in SuperPro Designer®. The integrated bioenergy plant produced hemp biodiesel and bioethanol from lipids and carbohydrates, respectively. The structural composition of the industrial hemp plant was analyzed in a previous study. The data obtained was used to simulate feedstock composition in SuperPro Designer®. The simulation results indicated that Hemp containing 2% lipids can yield up to 3.95 million gallons of biodiesel annually. On improving biomass lipid content to 5 and 10%, biodiesel production increased to 9.88 and 19.91 million gallons, respectively. The breakeven unit production cost of hemp biodiesel with 2, 5, and 10% lipid containing hemp was $18.49, $7.87, and $4.13/gallon, respectively. The biodiesel unit production cost when utilizing 10% lipid-containing hemp was comparable to soybean biodiesel at $4.13/ gallon. Furthermore, sensitivity analysis revealed the possibility of a 7.80% reduction in unit production cost upon a 10% reduction in hemp feedstock cost. Furthermore, industrial hemp was capable of pro- ducing between 307.80 and 325.82 gallons of total biofuels per hectare of agricultural land than soybean.

09 BIOMASS FUELS↗

Data from Economic Perspective of Ethanol and Biodiesel Coproduction from Industrial Hemp

In this study, the economics of producing biofuels from an industrial hemp (Cannabis sativa) genotype – 19m96136 was investigated. A lignocellulosic biofuel plant, hourly consuming 85 metric tons of hemp biomass was modeled in SuperPro Designer®. The integrated bioenergy plant produced hemp biodiesel and bioethanol from lipids and carbohydrates, respectively. The structural composition of the industrial hemp plant was analyzed in a previous study. The data obtained was used to simulate feedstock composition in SuperPro Designer®. The simulation results indicated that Hemp containing 2% lipids can yield up to 3.95 million gallons of biodiesel annually. On improving biomass lipid content to 5 and 10%, biodiesel production increased to 9.88 and 19.91 million gallons, respectively. The breakeven unit production cost of hemp biodiesel with 2, 5, and 10% lipid containing hemp was $18.49, $7.87, and $4.13/gallon, respectively. The biodiesel unit production cost when utilizing 10% lipid-containing hemp was comparable to soybean biodiesel at $4.13/gallon. Furthermore, sensitivity analysis revealed the possibility of a 7.80% reduction in unit production cost upon a 10% reduction in hemp feedstock cost. Furthermore, industrial hemp was capable of producing between 307.80 and 325.82 gallons of total biofuels per hectare of agricultural land than soybean.

Conversion↗

Appendix Q: Recommendations for Developing Molecular Assays for Microbial Pathogen Detection Using Modern In Silico Approaches

We describe the use of in silico approaches to improve the process of molecular assay development and reduce time and cost by utilizing available databases of whole genome pathogen sequences combined with modern bioinformatics and physical modeling tools. Well-characterized assays are needed for accurately detecting pathogens in environmental and patient samples and also for evaluation of the efficacy of a medical countermeasure that may be administered to patients. The polymerase chain reaction (PCR) remains the gold standard for pathogen detection due to the simplicity of its instrumentation, low cost of reagents, and outstanding limit of detection (LOD), sensitivity, and specificity. However, creation of such PCR assays often involves iterations of design, preliminary testing, and thorough validation with clinical isolates and testing in relevant matrices, which can be time consuming, costly, and result in suboptimal assays. Since formal validation (e.g., for Emergency Use Authorization [EUA] or Food and Drug Administration [FDA] licensure) of an infectious disease assay can be very expensive and can require extensive time of development, having a well-designed assay up front is a critical first step. Yet, many assays described in the literature utilized limited design capabilities and many initially promising assays fail the validation process, resulting in increased costs and timelines for successful product development. While the computational approaches outlined in this document by no means obviate the need for wet lab testing, they can reduce the amount of effort wasted on empirical optimization and iterative redesigns and also guide validation studies. The proposed computational approaches also result in higher performing assays with better sensitivity, specificity, and lower LOD and reduce the possibility of assay failure due to signature erosion. To provide clarity, an extensive glossary of defined terms is provided.

59 BASIC BIOLOGICAL SCIENCES↗

The role of above-code labeling programs in reducing CO 2 e emissions in residential buildings

Residential buildings account for 15 % of total U.S. carbon dioxide (CO 2 ) emissions. Voluntary, above-code labeling programs, such as the ENERGY STAR and Zero Energy Ready Home programs, can play a crucial role in reducing the carbon footprint of the new construction residential building sector by encouraging adoption of more energy-efficient and lower emissions building practices and technologies. It's important for the industry to understand the carbon dioxide equivalent (CO 2 e) and energy cost savings potential of these programs. Here, to estimate the potential CO 2 e emissions savings for homes built to above-code labeling program levels, it is imperative to have reliable and accurate tools for estimating emissions from buildings. The open-source OpenStudio-ERI workflow employs detailed physics-based building energy modeling (BEM) to estimate energy usage and operational CO 2 e emissions. In this study we use the OpenStudio-ERI workflow and regional, time-varying emissions factors from the Cambium database to compare the CO 2 e emissions and energy costs of homes built to performance levels required by these above-code labeling programs relative to homes built to model energy codes. We present the results of our analysis and provide a range of emissions and annual energy cost savings for the above-code labeling programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Charging Hub Scenario Sheet Screenshot

The Excel-based CHECT tool estimates the LCOC ($/kWh) by charger type (Level 1, Level 2, and DC fast charging) for a given charging hub scenario. CHECT requires users to input certain charging hub scenario parameters, including the number of chargers, daily utilization, and charger replacement frequency by charger type. Additional inputs such as the charging schedule, local utility rates, capital/operational costs, and financial inputs can be customized by the user, or the tool can generate results using appropriate default values from literature for the charging hub scenario and service location(s). Using the above inputs, CHECT performs a robust techno-economic analysis to generate the LCOC by charger type, broken down by cost category (e.g., capital, operational, utility, taxes) for various combinations of charging hub types (multiunit dwelling or public) and ownership models (residential, utility, or private company). It also outputs the annual discounted cash flows and determines the most sensitive input variables. In addition, the tool allows users to easily compare the LCOC across various ownership models or across different states.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Active and passive cooling approaches for a Southern California residential community

This study assesses cooling strategies in a low-income community in Southern California that lacks air conditioning and struggles with heat and air pollution. We used an urban building energy model and an electric distribution system model to evaluate active and passive cooling measures. The most effective space cooling measures were high-performance air-source heat pumps, cool coatings, window films, and harnessing the space cooling effect from heat pump water heaters. The results show that combining heat pump water heaters with window films and cool coatings reduces heat index hazard hours within buildings by 95 % to 99 % but increases total energy costs (equipment costs plus changes in utility bills) by 20 % to 60 % where the higher end includes building electrical upgrades. These measures also led to increased space heater use during colder months to avoid overcooling. Replacing conventional heaters with air source heat pumps eliminated unsafe indoor temperatures and reduced total energy use, but increased cost by 125 % to 150 %. In total, using heat pumps for space and water heating could reduce primary energy use by up to 57 %. The higher cost of active and passive cooling measures can be mitigated by existing and emerging incentive programs, especially those that support heat pumps. Electric distribution upgrades to support community electrification are estimated to increase utility costs by $\$$25 to $\$$40 per ratepayer per year. The results underscore the potential and challenges of adapting building infrastructure in communities at risk from climate and environmental stressors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding and Strategies for Controlled Interfacial Phenomena in Lithium-Ion Batteries and Beyond

Electrolyte chemistry and properties and electrode structure and chemical properties particularly at the interfaces are crucial for the development of advanced battery components. This project focused on elucidating the roles of the electrolyte and electrode on the formation and evolution of the SEI layer and cell electrochemical performance on silicon and on Li metal anodes. For Si nano/microstructures we evaluated lithiation, volume changes, reactivity, and chemo-mechanical transformations as functions of nanoparticle size, shape, presence of coatings, electrolyte composition, electron leakage to the electrolyte, and cycling. For Li metal anodes we provided detailed analyses of the electrode and electrolyte effects on interfacial reactivity and as a function of microstructural evolution and underlying stochasticity as dendrites nucleate and grow. We thoroughly investigated and simulated how the chemistry of the various components of the electrolyte and the electrode architecture may affect the electrochemical reactions as well as cell degradation. A multiscale modeling approach was utilized, where atomistic simulations informed about the microscopic behavior of the system, and intermediate time and length scales were investigated with mesoscopic models. Results were also tested against selected experiments from our collaborators. The combined theoretical-experimental strategy saves costs by utilizing predictions from computational analyses to guide experimentation.

25 ENERGY STORAGE↗

Low-Cost Highly Recyclable Structural Composites Utilizing Vitrimers and Natural Fibers (Basalt) Manufactured via a Novel Pultrusion Method for High-Volume Applications

The project’s overall goal is to explore and demonstrate as proof-of-concept that a highly recyclable and repairable composite material system, that is reinforced with natural fibers, can be used to produce lightweight structural components using a low-cost manufacturing process for high-volume automotive applications. More specifically, the project’s objectives will focus on vitrimer resins (which are a hybrid polymeric system of thermoplastics and thermosets) reinforced with basalt fibers and manufactured using pultrusion technologies. Pultrusion, as a method, is well-known to be one of the lowest-cost manufacturing processes for high-volume applications. However, to date, the validity and viability of such attractive objectives have not been demonstrated in support of the automotive industry.

36 MATERIALS SCIENCE↗

Cost Effectiveness of ASHRAE Standard 90.1-2016 for the State of Rhode Island

This report describes the methodology and results of a state cost-effectiveness analysis of ASHRAE Standard 90.1-2016. Moving to the Standard 90.1-2016 edition from Standard 90.1-2013 is found to be cost-effective for the state. Annual energy cost savings, added construction costs, and life-cycle costs are all described and presented here for various building types and climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost Effectiveness of ASHRAE Standard 90.1-2016 for the State of South Carolina

This report describes the methodology and results of a state cost-effectiveness analysis of ASHRAE Standard 90.1-2016. Moving to the Standard 90.1-2016 edition from Standard 90.1-2013 is found to be cost-effective for the state. Annual energy cost savings, added construction costs, and life-cycle costs are all described and presented here for various building types and climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost Effectiveness of ASHRAE Standard 90.1-2016 for the State of South Dakota

This report describes the methodology and results of a state cost-effectiveness analysis of ASHRAE Standard 90.1-2016. Moving to the Standard 90.1-2016 edition from Standard 90.1-2013 is found to be cost-effective for the state. Annual energy cost savings, added construction costs, and life-cycle costs are all described and presented here for various building types and climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost Effectiveness of ASHRAE Standard 90.1-2016 for the State of Tennessee

This report describes the methodology and results of a state cost-effectiveness analysis of ASHRAE Standard 90.1-2016. Moving to the Standard 90.1-2016 edition from Standard 90.1-2013 is found to be cost-effective for the state. Annual energy cost savings, added construction costs, and life-cycle costs are all described and presented here for various building types and climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost Effectiveness of ASHRAE Standard 90.1-2016 for the State of Utah

This report describes the methodology and results of a state cost-effectiveness analysis of ASHRAE Standard 90.1-2016. Moving to the Standard 90.1-2016 edition from Standard 90.1-2013 is found to be cost-effective for the state. Annual energy cost savings, added construction costs, and life-cycle costs are all described and presented here for various building types and climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost Effectiveness of ASHRAE Standard 90.1-2016 for the State of Vermont

This report describes the methodology and results of a state cost-effectiveness analysis of ASHRAE Standard 90.1-2016. Moving to the Standard 90.1-2016 edition from Standard 90.1-2013 is found to be cost-effective for the state. Annual energy cost savings, added construction costs, and life-cycle costs are all described and presented here for various building types and climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost Effectiveness of ASHRAE Standard 90.1-2016 for the State of Virginia

This report describes the methodology and results of a state cost-effectiveness analysis of ASHRAE Standard 90.1-2016. Moving to the Standard 90.1-2016 edition from Standard 90.1-2013 is found to be cost-effective for the state. Annual energy cost savings, added construction costs, and life-cycle costs are all described and presented here for various building types and climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗