Search NASA⌕ Search

SEARCH · Search NASA

Results for “utility scale”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Advancing the Deployment of Utility-Scale Photovoltaic Plants in the Northeast

As one of the premier research laboratories operated by the Department of Energy, Brookhaven National Laboratory (BNL) is pursuing an energy research agenda that focuses on renewable energy systems and will help to secure the nation's energy security. A key element of the BNL research is the advancement of grid-connected utility-scale solar photovoltaic (PV) plants, particularly in the northeastern part of the country where BNL is located. While a great deal of information has been generated regarding solar PV systems located in mostly sunny, hot, arid climates of the southwest US, very little data is available to characterize the performance of these systems in the cool, humid, frequently overcast climates experienced in the northeastern portion of the country. Recognizing that there is both a need and a market for solar PV generation in the northeast, BNL is pursuing research that will advance the deployment of this important renewable energy resource. BNL's research will leverage access to unique time-resolved data sets from the 37MWp solar array recently developed on its campus. In addition, BNL is developing a separate 1MWp solar research array on its campus that will allow field testing of new PV system technologies, including solar modules and balance of plant equipment, such as inverters, energy storage devices, and control platforms. These research capabilities will form the cornerstone of the new Northeast Solar Energy Research Center (NSERC) being developed at BNL. In this paper, an overview of BNL's energy research agenda is given, along with a description of the 37MWp solar array and the NSERC.

14 SOLAR ENERGY↗

Mechanisms of Dynamic Near-Wake Modulation of a Utility-Scale Wind Turbine

The current study uses large eddy simulations to investigate the transient response of a utility-scale wind turbine wake to dynamic changes in atmospheric and operational conditions, as observed in previous field-scale measurements. Most wind turbine wake investigations assume quasi-steady conditions, but real wind turbines operate in a highly stochastic atmosphere, and their operation (e.g. blade pitch, yaw angle) changes constantly in response. Furthermore, dynamic control strategies have been recently proposed to optimize wind farm power generation and longevity. Therefore, improved understanding of dynamic wake behaviours is essential. First, changes in blade pitch are investigated and the wake expansion response is found to display hysteresis as a result of flow inertia. The time scales of the wake response to different pitch rates are quantified. Next, changes in wind direction with different time scales are explored. Under short time scales, the wake deflection is in the opposite direction of that observed under quasi-steady conditions. Finally, yaw changes are implemented at different rates, and the maximum inverse wake deflection and time scale are quantified, showing a clear dependence on yaw rate. To gain further physical understanding of the mechanism behind the inverse wake deflection, the streamwise vorticity in different parts of the wake is quantified. The results of this study provide guidance for the design of advanced wake flow control algorithms. The lag in wake response observed for both blade pitch and yaw changes shows that proposed dynamic control strategies must implement turbine operational changes with a time scale of the order of the rotor time scale or slower.

flow-structure interactions↗

Utility-Scale Lithium-Ion Storage Cost Projections for Use in Capacity Expansion Models

This work presents U.S. utility-scale battery storage cost projections for use in capacity expansion models. We create battery cost projections based on a survey of literature cost projections of battery packs and balance of system costs, with a focus on lithium-ion batteries. Low, mid, and high cost trajectories are created for the overnight capital costs and the operating and maintenance costs. We then demonstrate the impact of these cost projections in the Regional Energy Deployment System (ReEDS) capacity expansion model. We find that under reference scenario conditions, lower battery costs can lead to increased penetration of variable renewable energy, with solar photovoltaics (PV) seeing the largest increase. We also find that additional storage can reduce renewable energy curtailment, although that comes at the expense of additional storage losses.

25 ENERGY STORAGE↗

Coordinating Permit Offices and the Development of Utility-Scale Geothermal Energy (Presentation)

Permitting is a major component of the geothermal development process. Better coordination across government agencies could reduce uncertainty of the process and the actual time of permitting. This presentation highlights various forms of coordinating permit offices at the state and federal level in the western United States, discusses inefficiencies and mitigation techniques for permitting natural resource projects, analyzes whether various approaches are easily adaptable to utility-scale geothermal development, and addresses advantages and challenges for coordinating permit offices. Key successful strategies identified include: 1. Flexibility in implementing the approach (i.e. less statutory requirements for the approach); 2. Less dependence on a final environmental review for information sharing and permit coordination; 3. State and federal partnerships developed through memorandum of understanding to define roles and share data and/or developer information. A few of the most helpful techniques include: 1. A central point of contact for the developer to ask questions surrounding the project; 2. Pre-application meetings to assist the developer in identifying all of the permits, regulatory approvals, and associated information or data required; 3. A permit schedule or timeline to set expectations for the developer and agencies; 4. Consolidating the public notice, comment, and hearing period into fewer hearings held concurrently.

15 GEOTHERMAL ENERGY↗

Highly Accurate Method for Real-Time Active Power Reserve Estimation for Utility-Scale Photovoltaic Power Plants

This paper applies a robust technique for determining the available power from a curtailed utility-scale photovoltaic (PV) power plant. The proposed technique does not require deploying any additional equipment or sensors and is based only on the addition of new control logic to the existing power plant controller. Also, the proposed method is universally applicable to PV plants with any type of smart inverters and PV modules. Accurate determination of available power is important for using curtailed PV generation as a resource for various types of active power controls, such as spinning reserves and primary and secondary frequency control. For PV plants to be able to maintain the desired regulation range, the plant controller must be able to estimate the available aggregate peak power that all the plant's inverters can produce at any point in time and ensure that the control error stays within the tolerance band at all times. In this paper, we explore a highly accurate control method that uses dedicated inverters within the plant as reference units and evaluates the available aggregate peak power for the whole plant under different cloud variability conditions.

14 SOLAR ENERGY↗

Framework for Evaluating Grid Readiness for Integrating Electric Vehicles and Utility Scale Storage in India

Electric vehicles (EVs) and distributed solar are poised to grow substantially in India in the coming years following ambitious Government of India targets. The localized impact of these changes, both in terms of infrastructure investments and demand patterns, are not well understood, nor are tools for this type of analysis readily available. This paper describes the development of a framework that can analyze network readiness in terms of feeder impacts for distributed energy resources (DERs) including growing EV penetration, and the potential solutions introduced by utility-scale battery energy storage systems (BESSs). The building blocks of the feeder analysis require multiple data sets to be compiled into a usable network model. The work is driven by feeder head and distribution transformer (DT) loading data along with all the technical specifications and schematics of distribution feeders. These measured data sets are conditioned to remove any afflictions, and the cleaned load profiles are used to perform multi-year quasi-static time-series power flow analyses on detailed three-phase feeder models. EVs translated to grid-tied loads are represented with aggregated EV demand profile estimates based on possible charging scenarios in residential sector, and in workplace and/or public charging stations. Finally, BESSs are evaluated for their cost-effectiveness in the framework through an initial screening that includes the benefits of grid service applications to mitigate present and future overloading scenarios. The outcomes from this framework are expected to help utilities gauge the readiness of their distribution grid for integrating an increasing number of EVs as well as load growth during a projected multi-year time horizon, where BESSs can contribute in making the grid more reliable.

electric vehicles↗

Lifetime fatigue response due to wake steering on a pair of utility-scale wind turbines

Quantifying the impacts on turbine loads during wind farm control is an important consideration in assessing power production benefits. Wake steering controls aim to improve total wind farm performance by coordinating the control actions of individual turbines, wherein an upstream turbine is intentionally yawed at an offset angle from the measured wind direction. Consequently, this redirects its wake for improved power production and potentially reduces fatigue loads of the downstream turbines. This paper studies the lifetime fatigue loads associated with wake steering by using utility-scale wind turbine experimental data to conduct an analysis on a pair of wind turbines. This study was part of a large field experiment in which a group of five GE 1.5-MW SLE CWE turbines were selected as targets for conducting wake steering research. A standard loads instrumentation package and data acquisition system were installed on two turbines within the cluster to measure turbine fundamental loads. The time-series databases were used to calculate loads statistics as well as short-term and lifetime damage equivalent loads. Fatigue calculations followed the guidance in Annex H of the International Electrotechnical Commission standard 61400-1, Edition 4. Lifetime fatigue calculation results are presented in this analysis; three methods of assessing lifetime fatigue were used to determine percent difference for blade root moments, main shaft moments, main shaft torque, and tower top torque. For all three fatigue treatments, some components’ lifetime fatigue increases for the controlled turbine; however, the downwind turbine experienced a reduction in lifetime fatigue and combined effect for the turbine pair results in a reduction of fatigue when wake steering controls are applied.

17 WIND ENERGY↗

Life Cycle Greenhouse Gas Emissions of Utility-Scale Wind Power: Systematic Review and Harmonization

A systematic review and harmonization of life cycle assessment (LCA) literature of utility-scale wind power systems was performed to determine the causes of and, where possible, reduce variability in estimates of life cycle greenhouse gas (GHG) emissions. Screening of approximately 240 LCAs of onshore and offshore systems yielded 72 references meeting minimum thresholds for quality, transparency, and relevance. Of those, 49 references provided 126 estimates of life cycle GHG emissions. Published estimates ranged from 1.7 to 81 grams CO{sub 2}-equivalent per kilowatt-hour (g CO{sub 2}-eq/kWh), with median and interquartile range (IQR) both at 12 g CO{sub 2}-eq/kWh. After adjusting the published estimates to use consistent gross system boundaries and values for several important system parameters, the total range was reduced by 47% to 3.0 to 45 g CO{sub 2}-eq/kWh and the IQR was reduced by 14% to 10 g CO{sub 2}-eq/kWh, while the median remained relatively constant (11 g CO{sub 2}-eq/kWh). Harmonization of capacity factor resulted in the largest reduction in variability in life cycle GHG emission estimates. This study concludes that the large number of previously published life cycle GHG emission estimates of wind power systems and their tight distribution suggest that new process-based LCAs of similar wind turbine technologies are unlikely to differ greatly. However, additional consequential LCAs would enhance the understanding of true life cycle GHG emissions of wind power (e.g., changes to other generators operations when wind electricity is added to the grid), although even those are unlikely to fundamentally change the comparison of wind to other electricity generation sources.

17 WIND ENERGY↗

DISTINCT: Diversity in Solar Talent Through INnovative Curriculum and Training: An Integrated Research and Education Approach towards Creating Diversity and Advancing Utility-Scale Solar Technology

The DISTINCT project research objective is to develop an innovative N-port power converter for a utility-scale PV system that is modular, compact and cost-effective and that will enable the integration of a high-frequency, high-voltage solid-state transformer. The novelty of the proposed research is the electrical power conversion architecture using an N-port converter system that replaces the output 60Hz transformer with an integrated high-frequency low-weight solid-state transformer reducing power electronics and BOS costs to meet SunShot goals through modularity and direct high-voltage interconnection. A challenge in direct integration with a 13.8kV line is the high voltage handling capacity of the converters combined with high efficiency operation. The front-end converter for each port is a Neutral-Point Clamped (NPC) Multi-Level dc-dc Dual-Active Bridge (ML-DAB) which allows Maximum Power Point Tracking (MPPT). The integrated high frequency transformer provides the galvanic isolation between the PV and grid side and also steps up the low dc voltage from PV source. Following the ML-DAB stage, in each port, is an inverter with H-bridge configuration or NPC configuration. N number of NPC inverters’ outputs are cascaded to attain the per-phase line-to-neutral voltage to connect directly to the distribution grid (i.e. 13.8 kV). The cascaded inverters have the inherent advantage of using lower rated devices, smaller filters and low Total Harmonic Distortion (THD) required for PV grid interconnection. Our analysis and simulation results show improved performance on cost, efficiency, service life with zero downtime and THD. A comprehensive control scheme is presented to ensure the maximum power from each port and each phase are sent to the grid. A functional prototype of a 2-port converter with ML-DAB and cascaded H-bridges has been designed, built, and tested in a laboratory setup to verify the target technical metrics. The N-port converter system due to its modular structure with individual control per port can be easily adapted to integrate functionalities that go well beyond the conventional grid support functions and mitigates impacts of forecasted fast ramp downs or ramp ups and single-fault conditions by automatic reconfiguration of the output.

14 SOLAR ENERGY↗

Light and Elevated Temperature Induced Degradation (LeTID) in a Utility-Scale Photovoltaic System

Here, we present a detailed case study of degradation in monocrystalline silicon photovoltaic modules operating in a utility-scale power plant over the course of approximately three years. We present the results of degradation analysis on arrays within the site, and find that five of the six arrays degraded faster than the best performing array, even though the arrays consist of modules of the same manufacturer and model. We also describe the results of extensive laboratory characterization of modules returned from the field, including module- and cell-level current–voltage characterization, luminescence imaging, and accelerated testing. The laboratory test results and the field performance are consistent with light and elevated temperature induced degradation (LeTID). Notably, we observe differences in back contact technology between affected and unaffected modules. This article also demonstrates a method to identify possible LeTID degradation in the field and confirm the result with laboratory testing of a small number of modules.

14 SOLAR ENERGY↗

Highly Accurate Method for Real-Time Active Power Reserve Estimation for Utility-Scale PV Power Plants: Preprint

This paper applies a robust technique for determining the available power reserve from a curtailed utility-scale photovoltaic (PV) power plant. The proposed technique does not require deploying any additional equipment or sensors and is based only on the addition of new control logic to the existing power plant controller. Also, the proposed method is universally applicable to PV plants with any type of smart inverters and PV modules. Accurate determination of available power is important for using curtailed PV generation as a resource for various types of active power controls, such as spinning reserves and primary and secondary frequency control. For PV plants to be able to maintain the desired regulation range, the plant controller must be able to estimate the available aggregate peak power that all the plant's inverters can produce at any point in time and ensure that the control error stays within the tolerance band at all times. In this paper, we explore a highly accurate control method that uses dedicated inverters within the plant as reference units and evaluates the available aggregate peak power for the whole plant under different cloud variability conditions.

14 SOLAR ENERGY↗

A TCN-Based Hybrid Forecasting Framework for Hours-Ahead Utility-Scale PV Forecasting

This paper presents a Temporal Convolutional Network (TCN) based hybrid PV forecasting framework for enhancing hours-ahead utility-scale PV forecasting. The hybrid framework consists of two forecasting models: a physics-based trend forecasting (TF) model and a data-driven fluctuation forecasting (FF) model. Three TCNs are integrated in the framework for: i) blending the inputs from different Numerical Weather Prediction sources for the TF model to achieve superior performance on forecasting hourly PV profiles, ii) capturing spatial-temporal correlations between detector sites and the target site in the FF model to achieve more accurate forecast of intra- hour PV power drops, and iii) reconciling TF and FF results to obtain coherent hours-ahead PV forecast with both hourly trends and intra-hour fluctuations well preserved. To automatically identify the most contributive neighboring sites for forming a detector network, a scenario-based correlation analysis method is developed, which significantly improves the capability of the FF model on capturing large power fluctuations caused by cloud movements. Here, the framework is developed, tested, and validated using actual PV data collected from 95 PV farms in North Carolina. Simulation results show that the performance of 6 hours ahead PV power forecasting is improved by 20% - 30% compared with state-of-the-art methods.

42 ENGINEERING↗

Utility-Scale Power Router: Dynamic Control of Grid Assets Using Direct AC Converter Cells

ADEPT Project: Georgia Tech is developing a cost-effective, utility-scale power router that uses an enhanced transformer to more efficiently direct power on the grid. Existing power routing technologies are too expensive for widespread use, but the ability to route grid power to match real-time demand and power outages would significantly reduce energy costs for utilities, municipalities, and consumers. Georgia Tech is adding a power converter to an existing grid transformer to better control power flows at about 1/10th the cost of existing power routing solutions. Transformers convert the high-voltage electricity that is transmitted through the grid into the low-voltage electricity that is used by homes and businesses. The added converter uses fewer steps to convert some types of power and eliminates unnecessary power storage, among other improvements. The enhanced transformer is more efficient, and it would still work even if the converter fails, ensuring grid reliability.

ADEPT↗

An Investigation on the Pollen-Induced Soiling Losses in Utility-Scale PV Plants

Here in this study, the impact of pollen as a PV soiling agent is investigated. The performance data of five utility-scale PV plants in North Carolina, USA, was collected and analyzed using two soiling extraction methods. Satellite and environmental data, including pollen counts, cropland, and vegetation, was also collected and analyzed to identify impacts to soiling losses. During the spring peak pollen season, performance losses of >15% were observed at all five sites. Partial performance recoveries following the pollen season were slow, with lack of correlation with rainfall. This means that the statistical soiling estimation methods that assume abrupt performance recovery from rain are not appropriate for pollen-impacted solar sites. When manual cleanings were performed on site the performance recovery ranged from 5% to 11% indicating persistent soiling impacts are present in this region. The results of this work provide new insights into the phenomenon of pollen deposition on PV systems, demonstrating that 1) soiling can also affect systems located in rainy locations and 2) that its effects cannot be determined using the current estimation methodologies.

14 SOLAR ENERGY↗