Search NASA⌕ Search

SEARCH · Search NASA

Results for “visualization software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

COMBIgor (A data assistant for combinatorial scientists in Igor Pro) [SWR-19-16]

Combinatorial materials science experiments involve synthesis and spatially-resolved characterization of thin film sample libraries. As a result, the modern combinatorial materials science laboratory produces large, diverse, and complex data sets, requiring automation of analysis and visualization techniques. COMBIgor is a software package aimed to assist a combinatorial material scientists with large volumes of experimental data. This package, written in Igor Pro, offers a systematic approach to the loading, processing, and visualizing combinatorial data sets. COMBIgor is designed to be expanded on a laboratory, group, or individual basis to adopt additional loading, processing and visualization capabilities. By utilizing COMBIgor software package the burden of data management in combinatorial materials science experiments can be significantly reduced.

Bauers, Sage↗

Visualization Quality Assessment

Understanding how inaccuracies in visualizations affect users’ perception and understanding of scientific data is hard. Inaccuracies in visualizations are quite common and could arise from a range of sources such as errors in the original dataset arising from compression artifacts, errors in the capturing device, noise during transmission of the data, effects due to the algorithm being used to convert data to visualization images, images generated from neural networks, and sources we have yet to discover. Many image quality assessment metrics have been developed to quantify image errors. However, these are usually focused on “natural images” rather than visualizations of scientific data. Common image quality assessment metrics (IQAs) include MSE, PSNR, perceptual metrics such SSIM, FSIM as well as perceptual metrics using deep learning approaches. However, a critical part of understanding how errors are perceived by humans, and subsequently developing more accurate quality assessment metrics, is through user evaluation studies. The goal of this software is to develop a visualization quality assessment (VQA) process that will enable the generation of VQAs that can be used to quantify errors in scientific data visualizations. The VQA development process will include software to support user evaluation experimental design, analysis of visualization differences against standard quality metrics, and the ability to develop additional VQA metrics specific to scientific visualization images.

Grosset, Andre↗

Parallel Planes Information Visualization (DEPRECATED) [SWR-16-13]

This DEPRECATED software presents a user-provided multivariate dataset as an interactive three dimensional visualization so that the user can explore the correlation between variables in the observations and the distribution of observations among the variables.

Bush, Brian↗

From Data to Models and Analytics: An Integrated Scientific Computing Platform to Accelerate Environmental Research SBIR Phase I (Final Technical Report)

Phase I research was conducted to investigate the technical feasibility of an integrated open source platform GeoLib to provide turnkey solutions for model-data integration for environmental systems science (ESS), using modern web technologies, advances in HPC and cloud computing and high-performance visualization. A key feature of our platform is that it minimizes and automates data movement between data storage and computing systems. Another critical feature of the design is that it enables users to perform high-fidelity post-processing by performing high-performance visualization server-side and in-situ on the compute cluster close to the data. The investigation, which was performed over a 12-month period ending April 2019, centered on developing prototype software to demonstrate the key enabling technologies required for this system. This included: (i) rapid access to data from multiple remote sources, via a unified data interface; (ii) software for scalable geospatial visualization of raster, vector, and point cloud data on the web; (iii) development of an easy-to-use API for creating simulation and modeling workflows; (iv) remote data visualization and processing on middle-tier servers; and (v) remote data processing on high-performance computing systems. A critical part of this work is that all of these capabilities be accessible to end users through standard desktop tools such as Project Jupyter, which is widely adopted for ESS simulation and modeling.

97 MATHEMATICS AND COMPUTING↗

CaveMan Enterprise version 1.0 Software Validation and Verification.

The U.S. Department of Energy Strategic Petroleum Reserve stores crude oil in caverns solution-mined in salt domes along the Gulf Coast of Louisiana and Texas. The CaveMan software program has been used since the late 1990s as one tool to analyze pressure mea- surements monitored at each cavern. The purpose of this monitoring is to catch potential cavern integrity issues as soon as possible. The CaveMan software was written in Microsoft Visual Basic, and embedded in a Microsoft Excel workbook; this method of running the CaveMan software is no longer sustainable. As such, a new version called CaveMan Enter- prise has been developed. CaveMan Enterprise version 1.0 does not have any changes to the CaveMan numerical models. CaveMan Enterprise represents, instead, a change from desktop-managed work- books to an enterprise framework, moving data management into coordinated databases and porting the numerical modeling codes into the Python programming language. This document provides a report of the code validation and verification testing.

Hart, David↗

HunStat2 – a simple and low-cost potentiostat with electrochemical impedance spectroscopy capability

We have developed a low-cost (30 USD), simple do-it-yourself (DIY) potentiostat with cyclic voltammetry (CV), open circuit potential (OCP) and electrochemical impedance spectroscopy (EIS) capability. The HunStat2 potentiostat is based on Analog Devices' AD5941 Analog Front End chip, which significantly simplifies the construction of potentiostats for both direct and alternating current (DC and AC, respectively) techniques. Interested readers are provided with circuit diagrams and a bill of materials to build the potentiostat on their own. In addition, control software is also provided free of charge. The software enables acquisition and visualization of data. In summary, HunStat2 introduces a simple and low-cost DIY potentiostat recommended for both analytical and educational purposes.

Vamos, Istvan [Lajos Petrik Vocational Chemistry S↗

Science & Technology Review: The Road to Exascale Computing

At Lawrence Livermore National Laboratory, we focus on science and technology research to ensure our nation’s security. We also apply that expertise to solve other important national problems in energy, bioscience, and the environment. Science & Technology Review is published eight times a year to communicate, to a broad audience, the Laboratory’s scientific and technological accomplishments in fulfilling its primary missions. The publication’s goal is to help readers understand these accomplishments and appreciate their value to the individual citizen, the nation, and the world. The Department of Energy’s Exascale Computing Project (ECP) and Lawrence Livermore’s RADIUSS (Rapid Application Development via an Institutional Universal Software Stack) initiative benefit from strategically developed software tools. The front cover shows a simulation of advection under twisting rotation that uses high-order finite elements from Livermore’s Modular Finite Element Methods (MFEM) software library and GLVis visualization tool. On the back cover, the logo (also created with GLVis) for the MFEM project illustrates the curved mesh and sub-element resolution used in high-order simulations. MFEM and GLVis are key components of the ECP’s co-design Center for Efficient Exascale Discretizations (CEED) and RADIUSS. MFEM is also part of ECP’s Extreme-Scale Scientific Software Development Kit (xSDK).

97 MATHEMATICS AND COMPUTING↗

SU-E-J-199: A Software Tool for Quality Assurance of Online Replanning with MR-Linac

Purpose: To develop a quality assurance software tool, ArtQA, capable of automatically checking radiation treatment plan parameters, verifying plan data transfer from treatment planning system (TPS) to record and verify (R&V) system, performing a secondary MU calculation considering the effect of magnetic field from MR-Linac, and verifying the delivery and plan consistency, for online replanning. Methods: ArtQA was developed by creating interfaces to TPS (e.g., Monaco, Elekta), R&V system (Mosaiq, Elekta), and secondary MU calculation system. The tool obtains plan parameters from the TPS via direct file reading, and retrieves plan data both transferred from TPS and recorded during the actual delivery in the R&V system database via open database connectivity and structured query language. By comparing beam/plan datasets in different systems, ArtQA detects and outputs discrepancies between TPS, R&V system and secondary MU calculation system, and delivery. To consider the effect of 1.5T transverse magnetic field from MR-Linac in the secondary MU calculation, a method based on modified Clarkson integration algorithm was developed and tested for a series of clinical situations. Results: ArtQA is capable of automatically checking plan integrity and logic consistency, detecting plan data transfer errors, performing secondary MU calculations with or without a transverse magnetic field, and verifying treatment delivery. The tool is efficient and effective for pre- and post-treatment QA checks of all available treatment parameters that may be impractical with the commonly-used visual inspection. Conclusion: The software tool ArtQA can be used for quick and automatic pre- and post-treatment QA check, eliminating human error associated with visual inspection. While this tool is developed for online replanning to be used on MR-Linac, where the QA needs to be performed rapidly as the patient is lying on the table waiting for the treatment, ArtQA can be used as a general QA tool in radiation oncology practice. This work is partially supported by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

XtalCAMP: a comprehensive program for the analysis and visualization of scanning Laue X-ray micro-/nanodiffraction data

XtalCAMP is a software package based on the MATLAB platform, which is suitable for, but not limited to, the analysis and visualization of scanning Laue X-ray micro-/nanodiffraction data. The main objective of the software is to provide complementary functionalities to the Laue indexing software packages used at several synchrotron beamlines. Here, the graphical user interfaces allow the easy analysis of characteristic microstructure features, including real-time intensity mapping for a quick examination of phase, grain and defect distribution, 2D color-coded mapping of microstructural properties from the output of other Laue indexing software, crystal orientation visualization, grain boundary characterization based on orientation/misorientation calculation, principal strain/stress analysis, and strain ellipsoid representation, as well as a series of additional toolkits. As an example, XtalCAMP is applied to the microstructural investigation of a solution-heat-treated Ni-based superalloy manufactured using a laser 3D-printing technique, and a deformed natural quartzite from Val Bregaglia in the Central Alps.

36 MATERIALS SCIENCE↗

A framework for stochastic simulations and visualization of biological electron-transfer dynamics

Electron transfer (ET) dictates a wide variety of energy-conversion processes in biological systems. Visualizing ET dynamics could provide key insight into understanding and possibly controlling these processes. We present a computational framework named VizBET to visualize biological ET dynamics, using an outer-membrane Mtr–Omc cytochrome complex in Shewanella oneidensis MR-1 as an example. Starting from X-ray crystal structures of the constituent cytochromes, molecular dynamics simulations are combined with homology modeling, protein docking, and binding free energy computations to sample the configuration of the complex as well as the change of the free energy associated with ET. This information, along with quantum-mechanical calculations of the electronic coupling, provides inputs to kinetic Monte Carlo (KMC) simulations of ET dynamics in a network of heme groups within the complex. Visualization of the KMC simulation results has been implemented as a plugin to the Visual Molecular Dynamics (VMD) software. Finally, VizBET has been used to reveal the nature of ET dynamics associated with novel nonequilibrium phase transitions in a candidate configuration of the Mtr–Omc complex due to electron–electron interactions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Impact of compressed breast thickness and dose on lesion detectability in digital mammography: FROC study with simulated lesions in real mammograms

Purpose: The aim of this work was twofold: (1) to examine whether, with standard automatic exposure control (AEC) settings that maintain pixel values in the detector constant, lesion detectability in clinical images decreases as a function of breast thickness and (2) to verify whether a new AEC setup can increase lesion detectability at larger breast thicknesses. Methods: Screening patient images, acquired on two identical digital mammography systems, were collected over a period of 2 yr. Mammograms were acquired under standard AEC conditions (part 1) and subsequently with a new AEC setup (part 2), programmed to use the standard AEC settings for compressed breast thicknesses ≤49 mm, while a relative dose increase was applied above this thickness. The images were divided into four thickness groups: T1 ≤ 29 mm, T2 = 30–49 mm, T3 = 50–69 mm, and T4 ≥ 70 mm, with each thickness group containing 130 randomly selected craniocaudal lesion-free images. Two measures of density were obtained for every image: a BI-RADS score and a map of volumetric breast density created with a software application (VolparaDensity, Matakina, NZ). This information was used to select subsets of four images, containing one image from each thickness group, matched to a (global) BI-RADS score and containing a region with the same (local) VOLPARA volumetric density value. One selected lesion (a microcalcification cluster or a mass) was simulated into each of the four images. This process was repeated so that, for a given thickness group, half the images contained a single lesion and half were lesion-free. The lesion templates created and inserted in groups T3 and T4 for the first part of the study were then inserted into the images of thickness groups T3 and T4 acquired with higher dose settings. Finally, all images were visualized using the ViewDEX software and scored by four radiologists performing a free search study. A statistical jackknife-alternative free-response receiver operating characteristic analysis was applied. Results: For part 1, the alternative free-response receiver operating characteristic curves for the four readers were 0.80, 0.65, 0.55 and 0.56 in going from T1 to T4, indicating a decrease in detectability with increasing breast thickness. P-values and the 95% confidence interval showed no significant difference for the T3-T4 comparison (p = 0.78) while all the other differences were significant (p < 0.05). Separate analysis of microcalcification clusters presented the same results while for mass detection, the only significant difference came when comparing T1 to the other thickness groups. Comparing the scores of part 1 and part 2, results for the T3 group acquired with the new AEC setup and T3 group at standard AEC doses were significantly different (p = 0.0004), indicating improved detection. For this group a subanalysis for microcalcification detection gave the same results while no significant difference was found for mass detection. Conclusions: These data using clinical images confirm results found in simple QA tests for many mammography systems that detectability falls as breast thickness increases. Results obtained with the AEC setup for constant detectability above 49 mm showed an increase in lesion detection with compressed breast thickness, bringing detectability of lesions to the same level.

60 APPLIED LIFE SCIENCES↗

SU-C-201-07: Validation of a GATE Gamma Camera Model for the Siemens Symbia

Purpose: To develop a simulation model of a clinical gamma camera/SPECT system and to validate the model using experimental and published measurements from the clinical system. Methods: Geant4 Application for Tomographic Emission (GATE) was used to create a model of the Siemens Symbia gamma camera. A modular model was implemented that allows specifying combinations of crystal thickness (3/8”, 5/8”) and collimator (LEHR, MELP, HE). Shielding, energy resolution, intrinsic resolution, crystal thickness, and collimator properties were set based on manufacturer specifications. Validation of the model was performed by simulating NEMA 2007 gamma camera tests including spatial resolution and sensitivity for Tc99; these were compared with experimental and published data for the scanner. The simulated energy spectra of a Tc99 line source in acrylic blocks was visually compared with the corresponding experimental acquisition. For a 4 cm diameter sphere filled with Tc99, the attenuation maps were generated from simulation data, and the photopeak and scatter window were extracted from GATE output using ROOT to create DICOM files to use in the clinical reconstruction. Results: Simulated spatial resolutions for LEHR 3/8” crystal at 0, 10 cm, 10 cm (with scatter), and 30 cm were 4, 6.7, 7.9, and 14.5 mm FWHM; these were 9% less than published data. For 5/8” crystal the spatial resolutions were 4.5, 7.0, 8.5, and 14.7 mm FWHM; these were 4% to 10% less than published data. Simulated sensitivity was within 3.5% of published data for both LEHR 3/8” and 5/8”. The simulated energy spectra matched the photopeak and scatter window well, but did overestimate the counts below 90 keV. The simulated attenuation map and projection data were successfully reconstructed with the clinical software, and the passed visual inspection. Conclusions: Validation of a specific clinical scanner allows future studies of quantification accuracy for both planar and SPECT imaging. Research reported in this publication was supported by the National Cancer Institute of the National Institutes of Health under Award Number R01CA138986. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

How does C-VIEW image quality compare with conventional 2D FFDM?

Purpose: The FDA approved the use of digital breast tomosynthesis (DBT) in 2011 as an adjunct to 2D full field digital mammography (FFDM) with the constraint that all DBT acquisitions must be paired with a 2D image to assure adequate interpretative information is provided. Recently manufacturers have developed methods to provide a synthesized 2D image generated from the DBT data with the hope of sparing patients the radiation exposure from the FFDM acquisition. While this much needed alternative effectively reduces the total radiation burden, differences in image quality must also be considered. The goal of this study was to compare the intrinsic image quality of synthesized 2D C-VIEW and 2D FFDM images in terms of resolution, contrast, and noise. Methods: Two phantoms were utilized in this study: the American College of Radiology mammography accreditation phantom (ACR phantom) and a novel 3D printed anthropomorphic breast phantom. Both phantoms were imaged using a Hologic Selenia Dimensions 3D system. Analysis of the ACR phantom includes both visual inspection and objective automated analysis using in-house software. Analysis of the 3D anthropomorphic phantom includes visual assessment of resolution and Fourier analysis of the noise. Results: Using ACR-defined scoring criteria for the ACR phantom, the FFDM images scored statistically higher than C-VIEW according to both the average observer and automated scores. In addition, between 50% and 70% of C-VIEW images failed to meet the nominal minimum ACR accreditation requirements—primarily due to fiber breaks. Software analysis demonstrated that C-VIEW provided enhanced visualization of medium and large microcalcification objects; however, the benefits diminished for smaller high contrast objects and all low contrast objects. Visual analysis of the anthropomorphic phantom showed a measureable loss of resolution in the C-VIEW image (11 lp/mm FFDM, 5 lp/mm C-VIEW) and loss in detection of small microcalcification objects. Spectral analysis of the anthropomorphic phantom showed higher total noise magnitude in the FFDM image compared with C-VIEW. Whereas the FFDM image contained approximately white noise texture, the C-VIEW image exhibited marked noise reduction at midfrequency and high frequency with far less noise suppression at low frequencies resulting in a mottled noise appearance. Conclusions: Their analysis demonstrates many instances where the C-VIEW image quality differs from FFDM. Compared to FFDM, C-VIEW offers a better depiction of objects of certain size and contrast, but provides poorer overall resolution and noise properties. Based on these findings, the utilization of C-VIEW images in the clinical setting requires careful consideration, especially if considering the discontinuation of FFDM imaging. Not explicitly explored in this study is how the combination of DBT + C-VIEW performs relative to DBT + FFDM or FFDM alone.

60 APPLIED LIFE SCIENCES↗

VTAnDeM: A python toolkit for simultaneously visualizing phase stability, defect energetics, and carrier concentrations of materials

Phase stability, defect formation energies, and carrier concentrations are closely interrelated features of semiconductors. Due to their joint dependence on the multidimensional chemical potential space, it is challenging to quantitatively establish patterns between these quantities in a given semiconductor, especially when the semiconductor is comprised of multiple elements. To enable synchronous visualization and analysis of these complementary material properties and their interdependence, we developed the Visualization Toolkit for Analyzing Defects in Materials (VTAnDeM). This python-based toolkit allows users to interactively explore how defect formation energies and carrier concentrations vary across the composition and chemical potential spaces of multicomponent semiconductors. Here, we illustrate the computational workflow that employs VTAnDeM as a post-processing tool for first-principles calculations and describe the data organization and theory underlying the visualization scheme. Furthermore, we believe that this software will serve as a useful tool for simultaneously visualizing the often complex and non-intuitive chemical potential – defect – carrier concentration phase space of semiconductors.

36 MATERIALS SCIENCE↗

Immersive Digital Twin Laboratory for Engineering Education (CRADA Final Report)

This project aimed to create an immersive digital twin laboratory that incorporates advanced tracking and visualization capabilities. In collaboration with Fort Lewis College, NREL designed a state-of-the-art physical visualization laboratory, developed a software platform to enable interaction with tracked physical objects in the laboratory, and provided proof-of-concept curricula that included manipulating these tracked objects. The project was initiated to address the growing need for innovative educational tools in engineering education. As renewable energy systems, particularly solar installations, become more complex, there is a pressing need to bridge the gap between theoretical knowledge and practical application. Traditional methods of teaching solar engineering concepts often fall short of providing students with a comprehensive, hands-on understanding. This immersive digital twin laboratory was conceived to fill that gap by creating a safe, non-energized setting where students can interact with augmented solar installation objects, gaining valuable insights into system performance, design, and maintenance. The project utilized extended reality (XR) technologies, including head-mounted displays (HMDs) and a whole-room optical motion tracking system, to connect physical objects with their digital twins in real time. The laboratory was equipped with MagicLeap 2 HMDs, supported by a Vicon Vero 2.2 Optical Tracking System, which provided precise 6-degrees-of-freedom (6-DOF) tracking. We developed a software platform to manage the interaction between the tracked physical objects and their virtual counterparts, enabling real-time data synchronization, object recognition, and virtual overlays. We designed the system to be flexible and extendable, allowing for future integration of additional objects and curriculum. This research advances the field of engineering education by demonstrating the potential of immersive digital twin environments. The laboratory provides a dynamic learning space where students can experiment, collaborate, and learn without the risks associated with live experimentation. The ability to simulate and manipulate solar installation objects under various conditions has broad implications for workforce development, particularly in renewable energy. The project also highlights the economic feasibility of using XR technologies in educational settings, offering a cost-effective solution for institutions looking to enhance their curriculum. By fostering a deeper understanding of solar energy systems, this work contributes to the broader goal of supporting the global energy transition and preparing the next generation of engineers and technicians.

24 POWER TRANSMISSION AND DISTRIBUTION↗