Search NASA⌕ Search

SEARCH · Search NASA

Results for “visualization techniques and methodologies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

117 records · Page 7

Sub-pilot-scale Production of High-Value Products from U.S. Coals

Investigators from the University of Utah, University of Wyoming and Marshall University pursued a program to study the conversion of raw coal to high-value products of carbon fiber and silicon carbide. Team members also developed an initial framework for a data portal that can incorporate laboratory data on coal processing and product quality, and also work with tools for machine learning for data analysis, data visualization and economic assessment. Experimental R&D efforts focused on the conversion of raw coal to coal tar and other byproducts, and the resulting tar intermediates were upgraded to form anisotropic and isotropic pitch materials. These pitch materials were produced from coal using both thermal (pyrolysis) and chemical (mild solvolysis liquefaction) decomposition of raw coal. Four different coals were studied: Utah bituminous coal (Sufco), Wyoming PRB coal (Black Thunder), Illinois bituminous coal (Illinois #6), and West Virginia bituminous coal (Flying Eagle). Both metallurgical-grade coking coals and lower-grade steam coals were investigated, and controlled secondary gas-phase reactions were used during a two-stage pyrolysis process to induce cracking and condensation reactions among the pyrolytic tar species. This approach successfully improved the performance of the lower grade coals for yielding pitch materials, with properties more consistent with a commercial-grade pitch that had previously demonstrated success for quality carbon fiber production. The use of waste plastic materials was also studied, to help improve physical and chemical characteristics of the intermediate tars and final pitch product; in particular, for lowering the pitch softening point to an acceptable level for melt spinning carbon fiber. Mild solvolysis liquefaction was also used as a method for producing pitch for carbon fiber production. As expected, significantly higher pitch yields were obtained using this approach, and waste plastic materials were also successfully used to reduce pitch softening point to an acceptable level. The plastic materials were also utilized to create a solvent for the mild solvolysis process, and this plastic-derived solvent was shown to provide results consistent with more expensive commercial chemical solvents, and could thus avoid the need for costly recovery and recycle of a liquefaction solvent. Additional experimental R&D focused on the production of silicon carbide (β-SiC) from the residual char byproduct from pitch production, and also on the production of carbon fiber from the anisotropic pitch. SiC was successfully synthesized using a mixture of residual char and sandstone at a ratio of 1:1. Reaction temperature and residence time were optimized and yielded a product purity of 81%. For carbon fiber production, the most successful pitch samples were obtained from the mild solvolysis liquefaction approach, combined with the use of a plastic (HDPE)-derived solvent. Fiber properties improved over time as laboratory fiber production methodologies improved, and final yields of carbon fiber were obtained with a diameter of 12.14 ± 1.10 um, Modulus of 173.73 ± 15.25 GPa, and Tensile Strength of 1.04 ± 0.10 GPa. A proof-of-concept Modern Community Research Data Portal (MCRDP) was developed and deployed for coal and coal-derived pitch characterization, with the full support of (i) remote web-based access, (ii) distributed analysis, (iii) interactive visualization and exploration, (iv) shared and long-term data access, (v) advanced query capabilities and (vi) real-time collaboration. The Coal to Products Data Portal “coaltoproducts.org” provides researchers with space to store and share data within a project, tools for analyzing and understanding data for scientific investigation, and the ability to publish data to the broader community for reproducibility. The portal leverages the Material Commons 2.0 (MC) platform developed by the Center for PRedictive Integrated Structural Materials Science (PRISMS) of the University of Michigan, to achieve long-term longevity of data collections and, more importantly, collaborative science. A number of data visualization tools were also assessed and implemented for interrogating the experimental and modeling data. The machine learning portion of this project analyzed datasets from two different coal conversion processes performed on a diverse set of coal samples from both the coal pyrolysis experiments and the solvent liquefaction experiments. The work was initiated by exploring standard regression models on the pyrolysis data, aiming to understand the impact of sample characteristics and processing conditions on key product metrics. Over the course of the project, the focus expanded to include a variety of machine learning tools, delving into both supervised and unsupervised learning methods. Models tested on the pyrolysis data included linear, ridge, lasso, elastic-net, Gaussian process, random forest regression, and AutoSklearn, and the approach was continually refined to enhance predictive accuracy and model interpretability. Similar techniques were applied to the liquefaction data with an additional focus on feature engineering. Along with mesophase content, additional outputs of interest were the pitch yield, softening point, and QI content. Insights derived from these analyses are crucial in determining the factors influencing the quality and yield of coal-derived products. As the work progressed, the research evolved from foundational model comparisons to analyses of random forests, decision paths, and feature importance scores. A thorough market analysis was performed to examine the prospects of coal-based carbon fibers. The best opportunities for coal come from its lower and more stable price relative to petroleum, particularly for subbituminous coals, which is the primary advantage that a coal refinery may have over a petroleum refinery. Before a commercial CTP production facility can be modeled, however, several things need to be understood regarding the nature of the would-be coal refinery. These include the technology to be deployed, the size of facility, the volume(s) of co-product(s), and the waste and emissions profile of the plant. The volume of co-products and waste may be substantial and will require separate market analysis to ensure viability. In the near-term, the importance of coal tar pitch, in the form of carbon pitch, to the aluminum and steel industries is likely to overshadow the alternative use of this material as an input for carbon fiber. The importance of steel and aluminum in building materials, and the need for carbon materials in their manufacturing, will ensure that demand for these products remains for the long run. In addition, carbon fiber may also be the best substitute for steel and aluminum well into the future. While society will eventually be able to shift production of much of its electricity needs to renewables, it will not be able to shift away from fossil fuels for production of high-strength construction and vehicular materials. Demand for carbon fiber is expected to increase quickly, but the volume of carbon fiber and the amount of coal that would be needed to produce even a sizeable share of this market may still be relatively small compared to current coal production. Thus, other coal-based products like graphene, graphite, carbon foams, resins, and carbon-based building products will play important roles in sustaining coal production as coal-fired power generation continues to decline.

01 COAL, LIGNITE, AND PEAT↗

Validation of CT dose-reduction simulation

The objective of this research was to develop and validate a custom computed tomography dose-reduction simulation technique for producing images that have an appearance consistent with the same scan performed at a lower mAs (with fixed kVp, rotation time, and collimation). Synthetic noise is added to projection (sinogram) data, incorporating a stochastic noise model that includes energy-integrating detectors, tube-current modulation, bowtie beam filtering, and electronic system noise. Experimental methods were developed to determine the parameters required for each component of the noise model. As a validation, the outputs of the simulations were compared to measurements with cadavers in the image domain and with phantoms in both the sinogram and image domain, using an unbiased root-mean-square relative error metric to quantify agreement in noise processes. Four-alternative forced-choice (4AFC) observer studies were conducted to confirm the realistic appearance of simulated noise, and the effects of various system model components on visual noise were studied. The ''just noticeable difference (JND)'' in noise levels was analyzed to determine the sensitivity of observers to changes in noise level. Individual detector measurements were shown to be normally distributed (p>0.54), justifying the use of a Gaussian random noise generator for simulations. Phantom tests showed the ability to match original and simulated noise variance in the sinogram domain to within 5.6%{+-}1.6% (standard deviation), which was then propagated into the image domain with errors less than 4.1%{+-}1.6%. Cadaver measurements indicated that image noise was matched to within 2.6%{+-}2.0%. More importantly, the 4AFC observer studies indicated that the simulated images were realistic, i.e., no detectable difference between simulated and original images (p=0.86) was observed. JND studies indicated that observers' sensitivity to change in noise levels corresponded to a 25% difference in dose, which is far larger than the noise accuracy achieved by simulation. In summary, the dose-reduction simulation tool demonstrated excellent accuracy in providing realistic images. The methodology promises to be a useful tool for researchers and radiologists to explore dose reduction protocols in an effort to produce diagnostic images with radiation dose ''as low as reasonably achievable.''.

61 RADIATION PROTECTION AND DOSIMETRY↗

Structural and Stratigraphic Controls on Methane Hydrate occurrence and distribution: Gulf of Mexico, Walker Ridge 313 and Green Canyon 955: Final Report

The goal of this project was to determine structural and stratigraphic controls on hydrate occurrence and distribution in Green Canyon (GC) 955 and Walker Ridge (WR) 313 blocks using seismic and well data. Gas hydrate was discovered in these blocks in coarse- and fine-grained sediments during the 2009 Joint Industrial project (JIP) Leg 11 drilling expedition. Although the immediate interest of the exploration community is exclusively hydrate which is present in coarse–grained sediments, factors that control hydrate and free gas distribution in the two blocks and whether coarse and fine-grained hydrate-bearing units are related in any manner, formed the core of this research. The project spanned from 10/01/2012 to 07/31/2016. In the project, in both the leased blocks, the interval spanning the gas hydrate stability zone (GHSZ) was characterized using a joint analysis of sparse Ocean Bottom Seismic (OBS) and dense, surface–towed multichannel seismic (MCS) data. The project team had the luxury of calibrating their results with two well logs. Advance processing methods such as depth migration and full-waveform inversion (FWI) were used for seismic data analysis. Hydrate quantification was achieved through interpretation of the FWI velocity field using appropriate rock physics models at both blocks. The seismic modeling/inversion methodology (common to both GC955 and WR313 blocks) was as follows. First, the MCS data were depth migrated using a P-wave velocity (VP) model constructed using inversion of reflection arrival times of a few (four in both cases) key horizons carefully picked in the OBS data to farthest possible offsets. Then, the resolution of the traveltime VP model was improved to wavelength scale by inverting OBS gathers up to the highest frequency possible (21.75 Hz for GC955 and 17.5 for WR313) using FWI. Finally, the hydrate saturation (or the volume fraction) was estimated at the well location assuming one of the other hydrate morphology (filling the primary or the secondary porosity) was extrapolated out from the wells using the FWI VP as a guide. General outcomes were as follows. First and foremost, an imaging methodology using sparse seismic data, which is easily replicable at other sites with similar datasets, has been demonstrated. The end product of this methodology at both the leased blocks is quantitative estimates of hydrate distribution. Second, at both locations there is strong evidence that the base of the GHSZ, which does not appear as a clear Bottom Simulating Reflection (BSR), manifests in the VP perturbations created by FWI, suggesting that FWI is sensitive to subtle compositional changes in shallow sediments and establishes it as a valuable tool for investigations of hydrate-bearing basins. Third, through joint interpretation of the depth migrated image and the FWI VP model, how structure and stratigraphy jointly determine hydrate and free gas distribution in both blocks could be clearly visualized. The joint interpretation also suggests that the coarse and fine grained hydrate-bearing sediments at both leased are connected. Site specific results, in addition to general results, are as follows. At GC955 the overlying fine-grained hydrate-bearing unit could have been sourced from the underlying hydrate coarse-grained channel-levee complex through a chimney feature. The channel-levee system at GC955 is compartmentalized by faults, of which only a few may be impermeable. Although compartmentalized, the channel-levee system in the GC955 as a whole might be in communication except selected zones. At WR313 the overlying fine-grained fracture-filled hydrate unit appears to be sourced from below the GHSZ. The reason that only a particular fine-grained unit has hydrate, despite having lower porosity that the bounding units, could be the presence of secondary porosity (such as those formed from clay dewatering under compaction). In conclusion, the project was a pioneering effort in in joint analysis of OBS and MCS datasets for advancing the knowledge about a hydrate and free–gas system dynamics using advanced processing methods such as FWI and depth migration. Results obtained in this project can greatly advance the tools and techniques used for delineating specific hydrate prospects. Results obtained in this project can also be seamlessly incorporated into other DOE funded project on modeling the potential productivity and commercial viability of hydrate from sand-dominated reservoirs. The OBS and MCS data in this project were acquired in 2012 (after the JIP II drilling) by the USGS and therefore the results are a posteriori. Nonetheless, the seismic inversion workflow established through this project can be used to generate various what-if quantification scenarios even in absence of logs and serve as a valuable tool for guiding drilling operations. Results from this project can augment other DOE sponsored projects on determining the commercial viability of methane production from the Gulf of Mexico.

03 NATURAL GAS↗

Material separation in x-ray CT with energy resolved photon-counting detectors

Purpose: The objective of the study was to demonstrate that, in x-ray computed tomography (CT), more than two types of materials can be effectively separated with the use of an energy resolved photon-counting detector and classification methodology. Specifically, this applies to the case when contrast agents that contain K-absorption edges in the energy range of interest are present in the object. This separation is enabled via the use of recently developed energy resolved photon-counting detectors with multiple thresholds, which allow simultaneous measurements of the x-ray attenuation at multiple energies. Methods: To demonstrate this capability, we performed simulations and physical experiments using a six-threshold energy resolved photon-counting detector. We imaged mouse-sized cylindrical phantoms filled with several soft-tissue-like and bone-like materials and with iodine-based and gadolinium-based contrast agents. The linear attenuation coefficients were reconstructed for each material in each energy window and were visualized as scatter plots between pairs of energy windows. For comparison, a dual-kVp CT was also simulated using the same phantom materials. In this case, the linear attenuation coefficients at the lower kVp were plotted against those at the higher kVp. Results: In both the simulations and the physical experiments, the contrast agents were easily separable from other soft-tissue-like and bone-like materials, thanks to the availability of the attenuation coefficient measurements at more than two energies provided by the energy resolved photon-counting detector. In the simulations, the amount of separation was observed to be proportional to the concentration of the contrast agents; however, this was not observed in the physical experiments due to limitations of the real detector system. We used the angle between pairs of attenuation coefficient vectors in either the 5-D space (for non-contrast-agent materials using energy resolved photon-counting acquisition) or a 2-D space (for contrast agents using energy resolved photon-counting acquisition and all materials using dual-kVp acquisition) as a measure of the degree of separation. Compared to dual-kVp techniques, an energy resolved detector provided a larger separation and the ability to separate different target materials using measurements acquired in different energy window pairs with a single x-ray exposure. Conclusions: We concluded that x-ray CT with an energy resolved photon-counting detector with more than two energy windows allows the separation of more than two types of materials, e.g., soft-tissue-like, bone-like, and one or more materials with K-edges in the energy range of interest. Separating material types using energy resolved photon-counting detectors has a number of advantages over dual-kVp CT in terms of the degree of separation and the number of materials that can be separated simultaneously.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring Classification of Topological Priors With Machine Learning for Feature Extraction

In many scientific endeavors, increasingly abstract representations of data allow for new interpretive methodologies and conceptualization of phenomena. For example, moving from raw imaged pixels to segmented and reconstructed objects allows researchers new insights and means to direct their studies toward relevant areas. Thus, the development of new and improved methods for segmentation remains an active area of research. With advances in machine learning and neural networks, scientists have been focused on employing deep neural networks such as U-Net to obtain pixel-level segmentations, namely, defining associations between pixels and corresponding/referent objects and gathering those objects afterward. Topological analysis, such as the use of the Morse-Smale complex to encode regions of uniform gradient flow behavior, offers an alternative approach: first, create geometric priors, and then apply machine learning to classify. This approach is empirically motivated since phenomena of interest often appear as subsets of topological priors in many applications. Using topological elements not only reduces the learning space but also introduces the ability to use learnable geometries and connectivity to aid the classification of the segmentation target. Here, in this article, we describe an approach to creating learnable topological elements, explore the application of ML techniques to classification tasks in a number of areas, and demonstrate this approach as a viable alternative to pixel-level classification, with similar accuracy, improved execution time, and requiring marginal training data.

97 MATHEMATICS AND COMPUTING↗

Reproducibility of 'Intelligent' Contouring of Gross Tumor Volume in Non-Small-Cell Lung Cancer on PET/CT Images Using a Standardized Visual Method

Purpose: Positron emission tomography/computed tomography (PET/CT) is increasingly used for delineating gross tumor volume (GTV) in non-small-cell lung cancer (NSCLC). The methodology for contouring tumor margins remains controversial. We developed a rigorous visual protocol for contouring GTV that uses all available clinical information and studied its reproducibility in patients from a prospective PET/CT planning trial. Methods and Materials: Planning PET/CT scans from 6 consecutive patients were selected. Six 'observers' (two radiation oncologists, two nuclear medicine physicians, and two radiologists) contoured GTVs for each patient using a predefined protocol and subsequently recontoured 2 patients. For the estimated GTVs and axial distances, least-squares means for each observer and for each case were calculated and compared, using the F test and pairwise t-tests. In five cases, tumor margins were also autocontoured using standardized uptake value (SUV) cutoffs of 2.5 and 3.5 and 40% SUV{sub max}. Results: The magnitude of variation between observers was small relative to the mean (coefficient of variation [CV] = 3%), and the total variation (intraclass correlation coefficient [ICC] = 3%). For estimation of superior/inferior (SI), left/right (LR), and anterior/posterior (AP) borders of the GTV, differences between observers were also small (AP, CV = 2%, ICC = 0.4%; LR, CV = 6%, ICC = 2%; SI, CV 4%, ICC = 2%). GTVs autocontoured generated using SUV 2.5, 3.5, and 40% SUV{sub max} differed widely in each case. An SUV contour of 2.5 was most closely correlated with the mean GTV defined by the human observers. Conclusions: Observer variation contributed little to total variation in the GTV and axial distances. A visual contouring protocol gave reproducible results for contouring GTV in NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feedback on Forty-year Long Clean-up Operations of a Contaminated Soil for Environmental Purpose - 20026

One of the CEA facilities in France is the place of miscellaneous mapping and clean-up operations since the 1980's. The final purpose of the conducted work deals with the environmental remediation of the building. In France, the absence of a regulatory framework for the management of sites polluted by radioactive substances, especially as the lack of release thresholds, has led to develop different approaches of soil radiological characterization. The geostatistical approach is part of them. Preliminary investigations are an unavoidable step prior to clearance and remediation. First, historical analysis enables to define site perimeters to investigate as well as to precisely locate expected contaminated parts. For radioactive pollutants, the media (water, soil, air) and transfer routes participate in the definition of the investigation perimeter and thus also need to be identified through a geological study. At the same time, functional analysis leads to choose the best measurement means which could provide useful information when combined with visual inspection. An equipment well adapted to easy-to-measure radionuclides as gamma emitters, such as gamma probe or on-site gamma spectrometry, is usually selected as a non-destructive assay. Coupled with spatial positions, processed on-site radiological data can be mapped. Data processing consists in mapping and kriging before a geostatistical analysis in order to identify the zones of interest to be targeted. Selected zones are not only linked to high level count rates but also to low level ones so that a pollution-free reference is known in the area. This data processing also enables to categorize waste types according to their origin and contamination levels. An expected volume of different waste then follows as well as the waste characterization equipments. In-depth investigations, e.g. core drillings and samplings, naturally ensue to aim at remediation optimization through the assessment of environmental impact. After clean-up operations, non-destructive assays as well as destructive samplings enable to check the effective clearance. Following this methodology in the present remediation work, results of the first non-destructive assay campaign highlighted a long-lived transuranic radionuclides contamination in the concrete flagstone. Successive non-destructive assays were then performed in the defined zones of interest. Count rates measured with a surface probe were first mapped. The best localization of destructive assays, i.e. core drillings at a 1 meter depth, came from this surface mapping followed by a geostatistical analysis. The concrete flagstone was totally removed. Then, the depth of soil to remove under the flagstone was optimized from the results of radiological activities measured in core drillings samples. A new surface mapping was then drawn after this partial soil excavation. The sand and demolition rubble samples, homogeneously constituted from the flagstone fragments, were analyzed by gamma spectrometry. Meanwhile, waste drums and other containers were also measured by gamma spectrometry and passive neutron measurement devices. All these results have brought miscellaneous pieces of information. In this context, major issues appear in terms of physical constraints such as the premises tininess as well as of soil sampling techniques and in terms of measurement performances assessment and the representativeness of homogeneous samples. The choice of radiological soil and waste characterization devices is described in the light of enhanced performances by keeping in mind radiation protection requirements and a willing to always optimize waste categories (very low level waste) and volume. The improvement of the characterization methods appears through this forty-year long work while sharing the feedback of encountered difficulties. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reliability Assessment of Remote Visual Examination

Remote visual testing (RVT) is a commonly used nondestructive examination method for inservice inspection (ISI) of reactor internals to detect cracking and gross component failures. Despite widespread use, the detection reliability of RVT and the factors that impact overall RVT performance have been unresolved issues. This report describes the results from an assessment sponsored by the U.S. Nuclear Regulatory Commission and conducted by the Pacific Northwest National Laboratory, in cooperation with the Electric Power Research Institute, for evaluating the reliability of RVT methods currently being used for [reactor] in-vessel visual inspection. The goal was to assess the performance of commercially applied RVT examination procedures implemented by qualified personnel, as well as to identify and qualitatively assess enhancements to examination procedures for detecting flaws in test specimens. The assessment was performed over three phases of research, with the results of the first phase used to identify key controllable parameters impacting RVT performance and to design the next two phases (round-robin testing). Participants in the round-robin tests included teams of inspectors from commercial nuclear power ISI vendors. Participants were asked to determine if a specimen contained a crack and its approximate location, orientation, and length. The detection and location information were used to compute estimates of the probability of detection and false call probability for various scenarios such as the placement and orientation of the flaw on the specimen, team-to-team variations in detection performance, and effects of secondary review on RVT detection. Results showed that crack opening displacement (COD) is the dominant factor in the reliability of crack detection using commercially applied RVT procedures, with crack length being weakly correlated with detection probability. The implication is that RVT detection is likely heavily dependent on the contrast produced by the crack opening, with crack detection becoming less reliable as the COD decreases. Further, the results indicated RVT will be challenged when cracks are located in the vicinity of surface features such as scratches or weld ripples, or close to the edge of welds where shadowing and/or the presence of weld undercuts may complicate the ability to detect the crack. The assessment also reinforced earlier findings on the importance of lighting in flaw detection and appeared to align with other studies that find improved reliability when using multiple inspectors or analysts. Finally, the results pointed to the importance of practice with specimens that mimic conditions likely to be found in the field. Based on the findings and limitations of the assessment, a number of recommendations are made regarding best practices for improving the reliability of RVT in a field setting and for addressing remaining informational gaps. This report describes the design and noted limitations of the three phases of research, the analysis methodology for each phase, and the results of the research. The results of this assessment provide a benchmark set of data on the reliability of RVT for detecting cracking, assuming the implementation of field-like inspection procedures. The likely impact of several uncontrolled factors on RVT detection performance are discussed, and recommendations regarding the use of these results to assess field performance are provided. Finally, recent advances in RVT technology are briefly discussed and point to the potential need for continued research to evaluate the capability and effectiveness of the technique as improvements are implemented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A GPU based high-resolution multilevel biomechanical head and neck model for validating deformable image registration

Purpose: Validating the usage of deformable image registration (DIR) for daily patient positioning is critical for adaptive radiotherapy (RT) applications pertaining to head and neck (HN) radiotherapy. The authors present a methodology for generating biomechanically realistic ground-truth data for validating DIR algorithms for HN anatomy by (a) developing a high-resolution deformable biomechanical HN model from a planning CT, (b) simulating deformations for a range of interfraction posture changes and physiological regression, and (c) generating subsequent CT images representing the deformed anatomy. Methods: The biomechanical model was developed using HN kVCT datasets and the corresponding structure contours. The voxels inside a given 3D contour boundary were clustered using a graphics processing unit (GPU) based algorithm that accounted for inconsistencies and gaps in the boundary to form a volumetric structure. While the bony anatomy was modeled as rigid body, the muscle and soft tissue structures were modeled as mass–spring-damper models with elastic material properties that corresponded to the underlying contoured anatomies. Within a given muscle structure, the voxels were classified using a uniform grid and a normalized mass was assigned to each voxel based on its Hounsfield number. The soft tissue deformation for a given skeletal actuation was performed using an implicit Euler integration with each iteration split into two substeps: one for the muscle structures and the other for the remaining soft tissues. Posture changes were simulated by articulating the skeletal structure and enabling the soft structures to deform accordingly. Physiological changes representing tumor regression were simulated by reducing the target volume and enabling the surrounding soft structures to deform accordingly. Finally, the authors also discuss a new approach to generate kVCT images representing the deformed anatomy that accounts for gaps and antialiasing artifacts that may be caused by the biomechanical deformation process. Accuracy and stability of the model response were validated using ground-truth simulations representing soft tissue behavior under local and global deformations. Numerical accuracy of the HN deformations was analyzed by applying nonrigid skeletal transformations acquired from interfraction kVCT images to the model’s skeletal structures and comparing the subsequent soft tissue deformations of the model with the clinical anatomy. Results: The GPU based framework enabled the model deformation to be performed at 60 frames/s, facilitating simulations of posture changes and physiological regressions at interactive speeds. The soft tissue response was accurate with a R{sup 2} value of >0.98 when compared to ground-truth global and local force deformation analysis. The deformation of the HN anatomy by the model agreed with the clinically observed deformations with an average correlation coefficient of 0.956. For a clinically relevant range of posture and physiological changes, the model deformations stabilized with an uncertainty of less than 0.01 mm. Conclusions: Documenting dose delivery for HN radiotherapy is essential accounting for posture and physiological changes. The biomechanical model discussed in this paper was able to deform in real-time, allowing interactive simulations and visualization of such changes. The model would allow patient specific validations of the DIR method and has the potential to be a significant aid in adaptive radiotherapy techniques.

60 APPLIED LIFE SCIENCES↗