Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage phasor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

With the increased requirements of real-time grid monitoring, disturbance location, and situation awareness, Phasor Measurement Units (PMUs) have become more critical for the Wide Area Measurement System (WAMS). However, the vulnerability of PMUs has not been well studied, especially under electromagnetic pulse (EMP) scenarios. The stable operation of the power system will be affected directly once EMP damages them. Therefore, studying their immunity to EMP events is urgent and necessary. In this paper, the effective impedance measurement scheme and pulsed current injection (PCI) testing are proposed for the port impedance measurement and immunity levels of PMUs. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then, the circuit of the pulsed current generator is set to generate a damping sinusoid, and the double exponential wave is applied to the port. Finally, using measured impedance as a generator load, the voltage and current responses of different ports are calculated in the PCI testing simulation. In conclusion, results reveal the characteristics of port impedance, waveforms of voltage and current, and distribution of accumulative energy. The relation between port impedance and the waveforms is discussed.

42 ENGINEERING↗

Inorganic voltage nanosensors for bioelectricity studies in bacterial communities

We developed both membrane potential nanosensors (MPNs) and voltage sensing dyes (VSDs), and quantitative optical measurement tools to measure membrane potential (MP) at the level of a single bacterial cell, with voltage resolution of ~10 mV changes. Our approach relied on (i) novel MPNs and novel VSDs that measures MPs via fluorescence lifetime; (ii) a quantitative approach to fluorescence lifetime imaging microscopy (FLIM) data based on a novel time-resolved camera and phasor analysis. We demonstrate MP measurements over time for single bacterial cells.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluating Methods for Measuring Grid Frequency in Low-Inertia Power Systems: Preprint

Accurate measurement of grid frequency is a critical component of reliable grid control. Traditionally, methods such as phase locked loops (PLLs) and discrete Fourier transforms (DFTs) have been used in inverters and phasor measurement units (PMUs) to measure frequency. However, as the percentage of inverter-based resources (IBRs) such as solar and wind has increased, these conventional frequency measurement methods are proving unable to guarantee reliable control in some cases. One challenge is measuring frequency during transient events, where there is a disruption in the steady state sinusoidal voltage. During these events, the underlying frequency of the grid may barely change, but measurement methods report a large spike in frequency due to the disrupted waveform. New methods must balance between suppressing spikes in frequency during faults, and providing fast, accurate, measurements in all other grid operation conditions, especially during events with high rate-of-change-of frequency (ROCOF), which are more prevalent in high-IBR power systems. This paper first surveys frequency measurement methods that have been proposed to reduce measurement errors during transient events. Then, both conventional and more novel frequency measurement methods are tested against an IEEE standard and industry recommendations, and their performance is evaluated for events simulated in PSCAD. Results quantify the trade-offs in performance during different grid conditions and lead to suggestions for the most appropriate frequency and ROCOF measurement methods for low inertia grids.

frequency↗

Phasor Measurement Units Optimal Placement and Performance Limits for Fault Localization

Here, the performance limits of faults localization are investigated using synchrophasor data. The focus is on a non-trivial operating regime where the number of Phasor Measurement Unit (PMU) sensors available is insufficient to have full observability of the grid state. Proposed analysis uses the Kullback Leibler (KL) divergence between the distributions corresponding to different fault location hypotheses associated with the observation model. This analysis shows that the most likely locations are concentrated in clusters of buses more tightly connected to the actual fault site akin to graph communities. Consequently, a PMU placement strategy is derived that achieves a near-optimal resolution for localizing faults for a given number of sensors. The problem is also analyzed from the perspective of sampling a graph signal, and how the placement of the PMUs i.e. the spatial sampling pattern and the topological characteristic of the grid affect the ability to successfully localize faults. To highlight the superior performance of presented fault localization and placement algorithms, the proposed strategy is applied to a modified IEEE 34, IEEE-123 bus test cases and to data from a real distribution grid. Additionally, the detection of cyber-physical attacks is also examined where PMU data and relevant Supervisory Control and Data Acquisition (SCADA) network traffic information are compared to determine if a network breach has affected the integrity of the system information and/or operations.

42 ENGINEERING↗

Online Monitoring Applications Enabled by Phasor Measurement Units: Technical Assistance to the Power Sectors of Southeast Asia

In this report, an overview of several online applications enabled by PMU measurements is provided. Besides a brief technical background for each application, the report also discusses control room displays and alarming methodologies used by North American organizations, and applicable standards set by the North American Electric Reliability Corporation (NERC). The five applications discussed herein are inertia monitoring, linear state estimation, voltage stability monitoring, small-signal stability monitoring, and forced oscillation monitoring.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Noncontact Monitoring of Overhead Transmission Lines Using Space Potential Phasor Measurements

Power system reliability requirements necessitate the development of measurement systems to monitor the operational state of critical transmission lines. Here in this article, a novel noncontact method for monitoring overhead transmission lines is proposed. The method is based on measuring the amplitude and relative phase of the transmission line's space potential at two or more strategically located points in space along with the use of passive phase shifters to enhance the sensitivity of the measurements. Applications of voltage unbalance and conductor sag measurements are demonstrated along with the results of conductor sag measurements on an operating 230-kV transmission line. It is shown that using enhanced relative phase measurements can significantly improve the sensitivity of the measurements.

47 OTHER INSTRUMENTATION↗

Event Screening Methods for the Eastern Interconnection Situational Awareness and Monitoring System (ESAMS)

The Eastern Interconnection Situational Awareness and Monitoring System (ESAMS) is a tool developed to explore the applications and advantages of sharing phasor measurement unit (PMU) data among operating entities. An initial conclusion from testing was that detected events required further screening before being reported to ensure that events would be of interest to system operators. The methods described in this report were integrated into ESAMS to meet this need. First, an event is screened for whether the change in voltage angle measurements indicates that the detected disturbance is sufficiently large. Next, an event is classified to determine if it was related to a loss of generation. Finally, a neural network is used to determine if the system’s response to the disturbance is normal or abnormal. These methods were tested with one month of field-measured PMU data. Results indicate that the additional information provided by these additional screening tools will improve selection of events for inclusion in the daily event reports automatically generated by ESAMS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PMU-data-driven Event Classification in Power Transmission Grids

This paper presents an event classification in transmission grids. The convolutional neural network (CNN)-based classifier is proposed to capture the temporal similarity of time-synchronized data stream from phasor measurement units (PMUs). The proposed CNN is trained using Bayesian optimization to search for the best hyperparameters. The effectiveness of the proposed event classification is validated through the real-world dataset from the U.S. transmission grids. This dataset includes line outage, transformer outage, frequency, and oscillation events. The validation process also includes different PMU outputs, such as voltage magnitude, phase angle, current magnitude, frequency, and rate of change of frequency (ROCOF). The results show that ROCOF gives the best classification performance compared to other PMU outputs. In addition, it is shown that the classifier trained with a larger dataset has higher accuracy. Moreover, the superiority of the proposed method is validated through comparison with other state-of-the-art classification methods.

Niazazari, Iman↗

Protection and Restoration Solutions to Reliable and Resilient Integration of Grid-connected PV Installations and Distributed Energy Resources: Design, Testbed, Proof of Work and Impact Studies (Final Report)

To gain a better understanding of the complex transients in a utility grid with a large number of solar PV installations coupled by PWM inverters during the protection and restoration period of the power grid, in this project a kW-level experimental system with dominating inverter-based resources and a hardware-in-loop simulation system with transmission and distribution models, as well as several SEL protective relays have been built and used. The major research findings of the project are summarized below in two perspectives: Experimental research: A self-organized ultra-high frequency solitary waveform is discovered and demonstrated in the hardware experimental system. Despite the familiarities, such a solitary waveform is distinct from any harmonics, transient, or resonance waves in that, it is 1) non-dispersive over time and space, 2) not associated with any active source or the linear superposition of sources, 3) half-cycle asymmetric, 4) not responding to filters or change of system characteristic resonance frequency, 5) ubiquitous as it occurs simultaneously everywhere in the system from DC supply, power lines, and the utility grid, and 6) explosive through tripping the protection or damaging susceptible devices or circuits. Analytical study: The nature of such a new waveform and an analytical explanation of its formation are studied based on related physics and non-linear science principles, with the following highlights: 1) such a new waveform follows the solutions to the Non-linear Schrödinger equation, so the classic linear perturbation theory is unable to explain or predict such a unique waveform as confirmed with the research team of RTDS; 2) the critical condition of occurrence of such a waveform is derived, which indicates that the breakings of solitary wave is a system synchronous issue between the utility grid in the 60Hz phasor domain and duty-ratio modulation of DC sources in the inverter switching frequency domain; 3) such a waveform carries energy mass so it could be detrimental; 4) such a waveform is deceiving as it is not readily detectable in the energy propagation direction by the primary protection equipment, while it is detrimental in the perpendicular direction of energy propagation, i.e. voltage direction. Thus, it has more likely challenges to the second primary equipment and devices, particularly at the weakest link and point such as aging insulation and inappropriate setting of susceptible devices. Therefore, such a waveform can be easily ignored in the aftermath investigation. The intellectual merits: The experimental discovery reveals certain unfamiliar transient phenomena that could challenge the integration of large-scale grid-connected solar PV installation during the group ride-through period of solar PV installations, commissioning of large-solar farms, or dramatic change of solar radiation conditions. Particularly, the research findings suggest that the occurrence of the unfamiliar transient phenomena is uniquely associated with the inverter-based solar PV installation, which is less likely to happen for rotary energy systems. The physics and non-linear science-based research work laid down an analytical path to the challenging transient stability problems including those that have been observed currently and future calls. Both experimental and analytical research results explain the limitation of many current research effects including some DoE research undertakings as well as possible solutions. The broader impacts: The research outcome of the project advances the understanding of the possible transient problems for the integration of inverter-based solar PV installation. It also highlights the theoretical and technical barriers for applying the conventional theory and technology to design and implement countermeasures against their adverse impacts of the large-scale solar PV installation and operation on grid reliability and security. More broadly, the research outcomes have shed some light on the open, fundamental challenges in the integration of large-scale solar photovoltaic energy into current and next-generation power grids across the country, and worldwide. The advanced physics and non-linear science-based analysis open up a path to harmonization of the renewables for societal energy needs via building a resilient and sustainable electric power infrastructure.

14 SOLAR ENERGY↗

Phasor-Based Adaptive Control of a Test-Feeder Distribution Network

Control in the power distribution system is needed to match the generation of electricity (that is, supply) with the demand for power (that is, load) at all times while maintaining a high level of power quality [1] (see "Summary"). The complexity of controlling the electric distribution system increases when distributed intermittent energy sources, such as solar photovoltaics (PVs), displace large-scale dispatchable generation [2]-[10]. Furthermore, if the supply from distributed resources exceeds the time-varying demand across a feeder, then the feeder-level voltage will increase. In extreme cases, large voltage increases will trigger the disconnection of distributed generation to protect electrical equipment and ensure customer safety. Consequently, coordinating renewable energy sources that are distributed throughout the distribution system-to match real-time demand across an entire power network-brings the additional challenge of maintaining a high level of supply reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Protection of Distribution Circuits with High Penetration of Solar PV: Distance, Learning, and Estimation-Based Methods

The results of DOE Solar Energy Technologies Office project 34233 are presented. The newest version of IEEE Standard 1547 enables photovoltaic inverters to ride through voltage disturbances, improving bulk system reliability, at the expense of removing undervoltage trip as a fast method of de facto fault detection in high PV adoption scenarios. The project explored new methods of fault detection that don't rely on communication systems and could be available quickly, including distance-based schemes, focused directional relays, and two different data-driven schemes. The schemes were evaluated with fast-phasor simulation, electromagnetic transient simulation, and field data collection at partner utilities Chattanooga Electric Power Board and Dominion Energy Virginia. Accomplishments and possible paths forward are summarized.

14 SOLAR ENERGY↗

Control of multiple resonant power processors in a multi-source system

Analysis and test results show that phasor-regulated, Mapham-derived resonant inverters can be paralleled to provide standardizing interfaces for multiple sources on a utility-type, aerospace power distribution bus. The basic sources do not require matching in any way, and may have grossly different characteristics. Fully stable system architectures with multiple sources, parallel/redundant distribution buses, and a wide variety of loads can be easily constructed and controlled. The commands and parameters available for system control allow for tight tolerance bus voltage control, and absolute power-sharing control from the various sources over the full range of possible source and load variations. That level of control enables simplified load power processing hardware and the distribution of losses to optimally load the source thermal control system. Positive control of all system performance and allocation of losses are not required by all missions or vehicles, and overall vehicle considerations do not always require the loads on vehicle energy sources and thermal control systems to be balanced. In those cases, power system control can be simplified, and a hierarchical set of defaults can be substituted for computer-generated or supervisory input commands to allow for stable, fully autonomous system operation.

Mildice, James↗

Enhancement of Distribution System State Estimation Using Pruned Physics-Aware Neural Networks

Realizing complete observability in the three-phase distribution system remains a challenge that hinders the implementation of classic state estimation algorithms. In this paper, a new method, called the pruned physics-aware neural network (P2N2), is developed to improve the voltage estimation accuracy in the distribution system. The method relies on the physical grid topology, which is used to design the connections between different hidden layers of a neural network model. To verify the proposed method, a numerical simulation based on one- year smart meter data of load consumptions for three-phase power flow is developed to generate the measurement and voltage state data. The IEEE 123-node system is selected as the test network to benchmark the proposed algorithm against the classic weighted least squares (WLS). Numerical results show that P2N2 outperforms WLS in terms of data redundancy and estimation accuracy.

distribution system state estimation↗

Extended Frequency Divider for Bus Frequency Estimation Considering Virtual Inertia from DFIGs

Accurate estimation of local bus frequency is important for effectively controlling both synchronous and nonsynchronous generators. As the power grid evolves to accommodate essential reliability services such as virtual inertia from nonsynchronous generators, conventional techniques to estimate frequency face challenges. This paper proposes a new frequency estimation method that can effectively include the inertia contributions from double-fed wind generators (DFIGs). This is achieved through the proposed extended frequency divider formula (FDF) to include the contributions of DFIGs via Thevenin equivalents. The proposed extended FDF does not suffer from numerical issues as compared to existing phasor angle derivative-based approaches. Moreover, the knowledge of the rotor speeds of the synchronous machine and DFIGs as well as of the network admittance matrix allows estimating the frequencies of all buses in the grid, thereby significantly improving system situational awareness with a limited number of measurements. Numerical results on the IEEE 39-bus power system with DFIGs show that the proposed method achieves more accurate bus frequency estimations than the original FDF formula and other approaches based on the numerical derivation of the bus voltage phase angles.

double-fed induction generator↗

Online Voltage Event Detection Using Synchrophasor Data with Structured Sparsity-Inducing Norms

This paper develops an accurate and computationally efficient data-driven framework to detect voltage events from PMU data streams. It develops an innovative Proximal Bilateral Random Projection (PBRP) algorithm to quickly decompose the PMU data matrix into a low-rank matrix, a row-sparse event-pattern matrix and a noise matrix. Here, the row-sparse pattern matrix significantly distinguishes events from normal behavior. These matrices are then fed into a clustering algorithm to separate voltage events from normal operating conditions. Large-scale numerical study results on real-world PMU data show that the proposed algorithm is computationally more efficient and achieves higher F scores than state-of-the-art benchmarks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Big Data Synchrophasor Monitoring and Analytics for Resiliency Tracking (BDSMART)

This report contains key findings from a project titled Big Data Synchrophasor Monitoring and Analytics for Resiliency Tracking (BDSMART), which was carried out through a collaborative effort of a team of researchers from Texas A&M Engineering Experiment Station, Temple University, and Quanta Technology, LLC. The in-kind support came from OSIsoft (acquired by AVEVA), which provided their PI Historian software to demonstrate the use case of streaming PMU data. The first section of the report describes the project goals and objectives related to the development of Machine Learning (ML) models capable of detecting and classifying events by processing phasor measurements captured in the field by Phasor Measurement Units (PMUs). The data for this study was contributed by the utilities/ISOs from the Western and Eastern interconnects and ERCOT, further referred to as Interconnect B (IC B), Interconnect A (IC A), and Interconnect C (IC C), respectively. The approach that the BDSMART Research Team proposed and the key research tasks defined by the team are outlined in this section. The next section describes the technical approach. We first discuss the data constraints related to the PMU measurements and data interpretation constraints imposed by the data contributors. They provided neither the topological information of the grid nor PMU placement locations and captured recorded data at very few locations in the system with the reporting rate of either 30 or 60 fps. The recordings are mostly positive sequence voltage, frequency, and ROCOF, and in some limited cases, three-phase voltages and currents. We then reflect on the bad data issues that stem from poor recording practices and vague definitions of the PMU status bits to supposedly be used for bad data identification. Finally, the data discovery points to imprecise time stamps with incomplete event start/end time, as well as inconsistent and incomplete event labeling, which combined make the implementation of the data models using supervising learning quite challenging. Following the data discovery study, we hypothesize that because the IC B data has the most complete labels, we should focus our model development on that data and then test it on data from other interconnects. We also define the common metrics used to evaluate the results from the ML algorithm tests. We concluded this section by summarizing the common ML models we used and explaining how we implemented and tested them. The issues from this section are expanded in the Training Dataset Report from this project. The final section of this report deals with the accomplishments and conclusions. As the accomplishments, we formulate the problem we are solving and what is achieved by solving the problem. We then reflect on each of the analytics tools we developed and point out the performance of each tool when applied to solving the mentioned problems. We reference this work for further details to the papers we published on each tool. In the conclusions, we give recommendations on how to improve future PMU recording practices to facilitate the ML algorithm implementation and guidance for the future standardization work aimed at clarifying the ambiguities associated with the PMU status bits. We finally list future tasks that can bring about further improvements in the proposed algorithms. The issues from this section are expanded in the Training, and Test Dataset Report filed at the project completion date.

97 MATHEMATICS AND COMPUTING↗