Search NASA⌕ Search

SEARCH · Search NASA

Results for “water heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Detailed Laboratory Evaluation of Electric Demand Load Shifting Potential of Controlled Heat Pump Water Heaters

The demand profile management of electric end uses is vital research for utilities and policymakers planning greenhouse gas emission reductions. In this study, detailed laboratory research was conducted on the load shifting potential of 4 grid-connected HPWHs and one electric resistance water heaters (ERWH). The testing applied different CTA-2045 shed and critical peak command designs under three water draw profiles. Highly-controlled laboratory experiments were conducted in Florida. One of the four HPWHs was a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load-up above tank setpoint. A three-hour morning (6 – 9 AM) and four-hour evening curtailment (4 – 8 PM) were defined as the shed or critical peak periods reflecting high-value control periods for utility coincident load for system-wide electric demand reductions. Tests were performed under baseline conditions (no load shift) and under varied load-shifting schemes, including load up and advanced load up, ahead of shed and critical peak commands. Data were collected from December 2020 – February 2022 in the laboratory and compared with field experiments in Florida and the Pacific Northwest. Grid-connected HPWHs were found to reduce peak demand by up to 0.47 kW compared to uncontrolled HPWH units, depending on time of day, control scheme, draw profile, and temperature cluster. The load up strategy demonstrated the ability of all units to utilize heat pump mode for extended periods ahead of peak events. Demand reductions for the HPWHs were much larger when compared with the ERWH— up to 1.64 kW with large hot water draws in winter.

Fenaughty, Karen↗

Pre-Commercial Scale-Up of a Gas-Fired Absorption Heat Pump

The project sought to advance the maturity of SMTI’s 80 kBTU/hr residential space and water heating GAHP from the engineering prototype stage (TRL-7) to pre-production readiness by addressing manufacturing, balance of system design and installation, cost, reliability, and field application questions. As part of this project, the project team has: (1) Matured the design package for a commercially ready product (2) Demonstrated compliance with relevant ANSI standards (3) Completed manufacturing and assembly process specifications (4) Completed total production cost estimates and capital equipment requirements (5) Initiated component and system level reliability assessments (6) Completed a small field demonstration including measured performance, installation requirements and expected costs, and customer/key stakeholder feedback. (7) Completed a Techno-economic analysis for representative applications and climate zones, including justification for utility incentive programs. (8) Completed a market intelligence report. Scope of Work: A multi-faceted project was completed that included: (a) design for manufacturing tasks for both the sealed system and balance of system, (b) development and trial of key manufacturing processes and techniques, (c) evaluation of component and system level reliability, (d) exploration of make/buy decisions including impact on cost and required capital. Additionally, (e) installation and monitoring of a small number of field test units was completed to demonstrate energy savings and collect customer/installer feedback, and (f) a focused market research task was completed to explore potential barriers and improve market introduction plans. These tasks addressed many of the remaining technical risks regarding long-term reliability, verification of manufacturing cost estimates and identification of cost concerns, identify installation and balance of system design criteria necessary to achieve energy savings and installed cost goals, and identify market barriers and strategies prior to product market introduction.

03 NATURAL GAS↗

Water and heat: New constraints on the evolution of the CV chondrite parent body

This paper focuses on the post-accretion history of CV3 chondrites, through a combination of petrographic and mineralogical characterization, magnetic measurements, spectral (Raman and Infrared) and thermo-gravimetric analysis of 31 meteorites (including 7 falls, 21 Antarctic and 3 non-Antarctic finds) spanning a wide metamorphic range. We classify the 21 Antarctic chondrites and the Bukhara fall into the CV Red , CV OxA , and CV OxB subgroups. We establish quantitative parameters relevant for this sub-classification. In comparison to CV Ox , CV Red chondrites are characterized by (i) a lower abundance of matrix, (ii) a higher abundance of metal, (iii) the presence of Ni-poor sulfides. In comparison to CV OxB , CV OxA are characterized by (i) similar matrix abundance, (ii) a higher abundance of metal, (iii) the presence of metal almost exclusively under the form of awaruite, (iv) lower Ni content of sulfides, (v) lower magnetic susceptibility and saturation remanence. In this work, both CV Ox (CV OxA and CV OxB ) and CV Red experienced aqueous alteration, and contain oxyhydroxides and phyllosilicates. We show that the abundance of these hydrated secondary minerals observed today in individual CV chondrites decreases with their peak metamorphic temperature. This is interpreted either as partial dehydration of these secondary minerals or limited hydration due to the rapid exhaustion of the water reservoir during parent body thermal metamorphism. Moreover, the lower abundance of oxyhydroxides (that have a lower thermal stability than phyllosilicates and may in large part postdate the peak of thermal metamorphism) in more metamorphosed CV chondrites is interpreted as lower availability of aqueous fluids during retrograde metamorphism in these meteorites. Lastly, we show that in comparison to CV OxB , CV OxA are systematically (i) more metamorphosed, (ii) less hydrated, (iii) depleted in ferromagnetic minerals, (iv) but enriched in metal in the form of secondary awaruite. CV OxA may be thermally metamorphosed CV OxB . CV Red are significantly different from CV Ox (matrix abundances, alteration products, opaque minerals), but span the same wide metamorphic range. This could be indicative of a laterally heterogeneous CV parent body, or suggest the existence of distinct parent bodies for CV Ox and CV Red chondrites.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparative Analysis of Model Predictive Control and MPC-Informed Rule-Based Control for Thermal Storage Operation in Ultra-Low Temperature 4th Generation District Heating Networks

The integration of thermal storage and heat pumps in district heating networks (DHNs) can significantly enhance operational flexibility and energy efficiency; however, the practical deployment of advanced control strategies is often hindered by forecasting requirements and computational complexity. This study presents a comparative analysis of thermal storage control strategies in an ultra-low-temperature fourth-generation DHN, focusing on the development of a simplified rule-based control (RBC) explicitly informed by Model Predictive Control (MPC) behavior. The proposed methodology systematically analyzes the charging and discharging decisions of an MPC-controlled system under ideal forecasting conditions and extracts recurrent control patterns as a function of key system variables, including outdoor temperature, thermal demand, and electricity price. These patterns are translated into a set of structured time- and condition-based rules, resulting in an MPC-informed RBC that embeds predictive insights while preserving implementation simplicity and operational transparency. The approach is validated on a realistic mixed-use urban district in Denver, Colorado, USA, equipped with a centralized air-source heat pump, distributed water-to-water heat pumps, and a central thermal storage unit. Results show that the tuned RBC attains approximately 96% of ideal MPC economic performance (-27% of costs), preserves values of technical and environmental indicators (reduction only of 2-3%), and substantially reduces complexity. Sensitivity analyses further demonstrate the robustness of the RBC under varying operational conditions (i.e., ambient temperature, electricity price). Overall, the study demonstrates that MPC-informed rule-based control represents an effective trade-off between control performance and real-world applicability, enabling the integration of additional system components while maintaining simplicity, robustness, and ease of implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing and Reducing Plug and Process Loads in Office Buildings

Plug and process loads (PPLs) account for 33% of U.S. commercial building electricity consumption (McKenney et al. 2010). (See Figure 1.) Minimizing these loads is a significant challenge in the design and operation of an energy-efficient building. Lobato et al. (2011) and Lobato et al. (2012) define PPLs as energy loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and that typically do not provide comfort to the occupants. The percentage of total building energy use from PPLs is increasing. According to the U.S. Department of Energy (DOE), by 2030, commercial building energy consumption is expected to increase by 24%; PPL energy consumption is anticipated to increase by 49% in the same time frame (DOE 2010). These trends illustrate the importance of PPL energy reduction to achieve an overall goal of reducing whole-building energy consumption.

30 DIRECT ENERGY CONVERSION↗

Assessing and Reducing Plug and Process Loads in Retail Buildings

Plug and process loads (PPLs) account for 33% of U.S. commercial building electricity consumption (McKenney et al. 2010). (See Figure 1.) Minimizing these loads is a significant challenge in the design and operation of an energy-efficient building. Lobato et al. (2011) and Lobato et al. (2012) define PPLs as energy loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and that typically do not provide comfort to the occupants. The percentage of total building energy use from PPLs is increasing. According to the U.S. Department of Energy (DOE), by 2030, commercial building energy consumption is expected to increase by 24%; PPL energy consumption is anticipated to increase by 49% in the same time frame (DOE 2010). These trends illustrate the importance of PPL energy reduction to achieve an overall goal of reducing whole-building energy consumption.

30 DIRECT ENERGY CONVERSION↗

Deep Reinforcement Learning for Autonomous Water Heater Control

Electric water heaters represent 14% of the electricity consumption in residential buildings. An average household in the United States (U.S.) spends about USD 400–600 (0.45 ¢/L–0.68 ¢/L) on water heating every year. In this context, water heaters are often considered as a valuable asset for Demand Response (DR) and building energy management system (BEMS) applications. To this end, this study proposes a model-free deep reinforcement learning (RL) approach that aims to minimize the electricity cost of a water heater under a time-of-use (TOU) electricity pricing policy by only using standard DR commands. In this approach, a set of RL agents, with different look ahead periods, were trained using the deep Q-networks (DQN) algorithm and their performance was tested on an unseen pair of price and hot water usage profiles. The testing results showed that the RL agents can help save electricity cost in the range of 19% to 35% compared to the baseline operation without causing any discomfort to end users. Additionally, the RL agents outperformed rule-based and model predictive control (MPC)-based controllers and achieved comparable performance to optimization-based control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental performance of ejector heat pump operating in the sub-critical mode

Ejector heat pump (EHP) is an efficient-energy technology with a promising potential to replace the vapor compression cycle in heating and cooling applications. It can be powered by low-grade waste heat and uses environmentally friendly working fluids. EHP has also become a viable solution in research seeking cooling applications. However, little attention has been paid to using EHP for heating purposes. In order to investigate this, a steam EHP for domestic water heating was designed and built. The coefficient of performance (COP) is evaluated at various operating and design conditions in sub-critical operational modes to achieve higher condensation temperatures. Two primary nozzles with a throat diameter of 1.5 mm and 2.0 mm were investigated. The primary nozzle is movable along the ejector’s axis, allowing investigation of its positional effects on the EHP’s COP. Further, experimental measurements revealed that using a smaller throat diameter results in a high COP and low back pressure. The EHP COP and back pressure increase when the LTE temperature increases. Using a throat diameter of 1.5 mm, the EHP COP increases as the nozzle exit position (NXP) becomes closer to the constant area section. A COP of 2.42 and a back pressure of 4.28 kPa are achieved at a high-temperature evaporator (HTE) temperature of 130 °C and a low-temperature evaporator (LTE) temperature of 30 °C using a primary nozzle with 1.5 mm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Results from DOE Cold Climate Heat Pump Challenge Field Validation

Space conditioning and water heating consume over 40% of the nation’s primary energy use and represent a significant component of many homeowners’ monthly energy bill. However, in cold climates, performance of heat pumps has traditionally suffered as the units have been unable to efficiently transfer heat from colder outdoor air temperatures to warm the interior space of homes. Optimizing heat pumps for cold climates (5 °F and below) requires coordinated effort to ensure heat pump technologies can be enjoyed by Americans living in these regions. The DOE Cold Climate Heat Pump (CCHP) Challenge sought to address this challenge by partnering with industry to develop, test, and validate the performance of new, highly efficient heat pumps in real homes. The Challenge, launched in 2021, brought together leading heating, ventilation, and air conditioning (HVAC) manufacturers to develop prototype units optimized for performance at cold climates. This report summarizes results from the field validation that occurred 2022-2024.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancements in Heat Transfer and Fluid Mechanics (Fundamentals and Applications)

Thermo-fluid science is a foundational discipline for numerous mechanical systems, particularly in energy production and building equipment, where thermal and mechanical energy transfer play critical roles. Advancements in heat transfer and fluid mechanics have significantly enhanced these systems, driving progress in associated market sectors. For instance, evaporator and condenser coils are essential for optimizing vapor compression cycles in building equipment. Heat pumps used for space and water heating constitute a major share of building systems, with microchannel heat exchanger technology at the forefront of these innovations. It is worth mentioning that advancements in heat transfer and fluid mechanics significantly alleviate the challenge of designing energy-efficient building equipment. The development of research techniques has contributed significantly to the advancement of science; for example, in the experimental field, non-intrusive measurement techniques such as Particle Image Velocimetry (PIV) are now capable of resolving flow behavior in a 3D format for different length and time scales.

42 ENGINEERING↗

Hydraulically opened cone vertical tube diffuser with slanted anti-siphon hole

A diffuser for a water heater fill tubes having a tube wall with an outside diameter. The diffuser includes an elongated flexible diffuser body for positioning at the outlet end of the fill tube. The diffuser body has a sealing end for sealing with an outside surface of the fill tube wall closest to the inlet end of the fill tube, and an open end for positioning at an end closest to the outlet end of the fill tube. The open end has a diameter larger than an outside diameter of the tube wall, thereby creating an diffuser water outlet opening between the diffuser body and the tube wall for redirecting radial water flow emanating from the fill tube water outlet opening(s) toward the diffuser outlet opening. A fill tube assembly for a water heater, a water heater, and a method for heating water are also disclosed.

Rendall, Joseph D.↗