Search NASA⌕ Search

SEARCH · Search NASA

Results for “xenon isotopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The composition of the atmosphere at the surface of Mars

The current status is summarized of investigations of the composition of the Martian atmosphere, in which use was made of the mass spectrometers that function as the analytical component of the molecular analysis experiments on the two Viking landers. The following points seem well established: N2, Ar-40, Ne, Kr, Xe, and the primordial isotope of Ar are present. The present atmosphere of Mars represents only a small fraction of the total amount of volatiles outgassed by the planet, so that high surface pressure and abundant water may have been present. The noble gases in the Martian atmosphere exhibit a relative abundance pattern similar to that in the earth's atmosphere and (except for Xe) to that in the primordial component of meteorites. The existence of a 'planetary component' is thus proven, supporting the arguments of those who favor a fractionation of noble gases prior to the formation of the planets. In spite of these similarities, the isotopic ratios of nitrogen, argon, and xenon indicate that the histories of the Martian and the earth's atmospheres have been very different.

Owen, T.↗

Krypton and xenon in the atmosphere of Venus

The paper reports a determination by the Pioneer Venus large probe neutral mass spectrometer of upper limits to the concentration of krypton and xenon along with most of their isotopes in the atmosphere of Venus. The upper limit to the krypton mixing ratio is estimated at 47 ppb, with a very conservative estimate at 69 ppb. The probable upper limit to the sum of the mixing ratios of the isotopes Xe-128, Xe-129, Xe-130, Xe-131, and Xe-132 is 40 ppb by volume, with a very conservative upper limit three times this large.

Donahue, T. M.↗

Nitrogen isotopes in lunar highlands breccias

Lunar highlands breccias from Apollo 14 and 16 which may have trapped solar wind gases at a very early epoch in the history of the moon, as implied by their high content of parentless fissiogenic xenon and sometimes of parentless radiogenic Xe-129, are analyzed for nitrogen content and isotopic composition using stepwise heating techniques. The results show that the nitrogen is not particularly light and was not acquired in very ancient times. The conflicting presence of both parentless xenon and nitrogen of relatively recent isotopic signature can be explained if the hypothetical light nitrogen is diluted by more abundant, heavier nitrogen. Accordingly, the very ancient soil components implied in these breccias by the presence of excess fission xenon were reexposed at a much later epoch, or mixed with younger soil components, before the compaction event.

Fourcade, S.↗

First STAX detector installation at the National Institute for Radioelements (IRE)

The Source Term Analysis of Xenon (STAX) project has been installing stack detectors at medical isotope production facilities to measure radioxenon emissions to investigate the effect of radioxenon releases on nuclear explosion monitoring. This paper outlines the installation of the first STAX detection system at the National Institute for Radioelements (IRE) in Fleurus, Belgium which has been operating for over three years and transferring collected data to the STAX repository. Information about the equipment installed, the data flow established, and calculations for determination of radioxenon releases from the facility are presented. Further. data quality was investigated to confirm values reported by STAX automated data processing and in a comparison of collected STAX data with data collected by IRE for regulatory reporting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isotopic compositions of rare gases in the carbonaceous chondrites Mokoia and Allende.

The isotopic compositions have been measured mass spectrometrically for neon, argon, krypton and xenon released from the carbonaceous chondrites Mokoia and Allende in stepwise heating experiments. The isotopic compositions of rare gases released from the meteorites at different temperatures varied quite considerably. A marked enrichment of Xe129 due to the decay of extinct nuclide I129 was observed in both meteorites. The variations of the isotopic ratios are partly caused by the presence of cosmic-ray spallation and neutron-capture products. In addition, however, a marked trend of mass-dependent variation of the isotopic ratios was observed in this work. The rare gas isotopes released from the meteorites appear to be systematically mass-fractionated relative to the relative abundances of the average carbonaceous chondrite. It seems that this phenomenon can be best explained as due to the fact that there exist reservoirs of two isotopically distinct gases in the meteorites and mixtures of these gases are being released at each temperature fraction.

Manuel, O. K.↗

Composition of solar wind noble gases released by surface oxidation of a metal separate from the Weston meteorite

The paper reports on a set of experiments intended to test the feasibility of determining elemental and isotopic ratios of the noble gases and nitrogen in the solar wind in metal separates from gas-rich ordinary chondrites. Helium, neon, and argon show clear evidence of a solar wind signature, while no solar component could be identified for xenon and nitrogen. Helium, neon, and argon elemental isotopic ratios appear to depend on depth within the metal grains. The ratios derived indicate that the Weston meteorite did not acquire its solar wind gases from a recent exposure to solar wind, but more probably at a time in the past similar to or even earlier than the exposure time of Apollo 17 breccias. The Ar-36/Ar-38 ratio, in tandem with other recent determinations of this value, indicates that the solar and terrestrial values can no longer be assumed to be equivalent.

Becker, R. H.↗

Supernovae, grains and the formation of the solar system

An investigation is conducted concerning the possibility that observed Mg-26 anomalies in meteorites may be related to a nucleosynthetic event which preceded the formation of the solar system by at most a few million years. The Al-26, which decayed to form the observed excess Mg-26, could have been produced in either explosive carbon burning or in a high temperature carbon burning shell source immediately preceding the explosion. The results of supernova grain condensation calculations are presented and related to the hypothesis that a 'last event' supernova was indeed related to the formation of the solar system and thus might have created the observed isotopic anomalies in magnesium, oxygen, neon, and xenon.

Lattimer, J. M.↗

Krypton and xenon in Apollo 14 samples - Fission and neutron capture effects in gas-rich samples

Gas-rich Apollo 14 breccias and trench soil are examined for fission xenon from the decay of the extinct isotopes Pu-244 and I-129, and some samples have been found to have an excess fission component which apparently was incorporated after decay elsewhere and was not produced by in situ decay. Two samples have excess Xe-129 resulting from the decay of I-129. The excess is correlated at low temperatures with excess Xe-128 resulting from neutron capture on I-127. This neutron capture effect is accompanied by related low-temperature excesses of Kr-80 and Kr-82 from neutron capture on the bromine isotopes. Surface correlated concentrations of iodine and bromine are calculated from the neutron capture excesses.

Drozd, R.↗

Lunar mass spectrometer test program

The procedures are described along with results obtained in a test program conducted to demonstrate the performance of a candidate lunar mass spectrometer. The instrument was designed to sample and measure gases believed to exist in the lunar atmosphere at the surface. The subject instrument consists of a cold cathode ion source, a small quadrupole mass analyzer and an off axis electron multiplier ion counting detector. The major program emphasis was placed on demonstrating instrument resolution, sensitivity and S/N ratio over the mass range 0-150 amu and over a partial pressure range from 10 to the minus 9th power to 10 to the minus 13th power torr. Ultrahigh vacuum tests were conducted and the minimum detectable partial pressure for neon, argon, krypton and xenon was successfully determined for the spectrometer using isotopes of these gases. With the exception of neon, the minimum detectable partial pressure is approximately 4 x 10 to the minus 14th power torr for the above gases.

Torney, F. L.↗

Lunar and Planetary Science XXXVI, Part 13

Contents include the following: A Fast, Non-Destructive Method for Classifying Ordinary Chondrite Falls Using Density and Magnetic Susceptibility. An Update on Results from the Magnetic Properties Experiments on the Mars Exploration Rovers, Spirit and Opportunity. Measurement Protocols for In Situ Analysis of Organic Compounds at Mars and Comets. Piping Structures on Earth and Possibly Mars: Astrobiological Implications. Uranium and Lead in the Early Planetary Core Formation: New Insights Given by High Pressure and Temperature Experiments. The Mast Cameras and Mars Descent Imager (MARDI) for the 2009 Mars Science Laboratory. MGS MOC: First Views of Mars at Sub-Meter Resolution from Orbit. Analysis of Candor Chasma Interior Layered Deposits from OMEGA/MEX Spectra. Analysis of Valley Networks on Valles Marineris Plateau Using HRSC/MEX Data. Solar Abundance of Elements from Neutron-Capture Cross Sections. Preliminary Evaluation of the Secondary Ion/Accelerator Mass Spectrometer, MegaSIMS. Equilibrium Landforms in the Dry Valleys of Antarctica: Implications for Landscape Evolution and Climate Change on Mars. Continued Study of Ba Isotopic Compositions of Presolar Silicon Carbide Grains from Supernovae. Paleoenviromental Evolution of the Holden-Uzboi Area. Stability of Magnesium Sulfate Minerals in Martian Environments. Tungsten Isotopic Constraints on the Formation and Evolution of Iron Meteorite Parent Bodies. Migration of Dust Particles and Volatiles Delivery to the Inner Planets. On the Sitting of Trapped Noble Gases in Insoluble Organic Matter of Primitive Meteorites. Trapping of Xenon Upon Evaporation-Condensation of Organic Matter Under UV Irradiation: Isotopic Fractionation and Electron Paramagnetic Resonance Analysis. Stability of Water on Mars. A Didactic Activity. Analysis of Coronae in the Parga Chasma Region, Venus. Photometric and Compositional Surface Properties of the Gusev Crater Region, Mars, as Derived from Multi-Angle, Multi-Spectral Investigation of Mars Express HRSC Data. Mapping Compositional Diversity on Mars: Spatial Distribution and Geological Implications. A New Simulation Chamber for Studying Planetary Environments. Folded Structure in Terra Sirenum. Mars. Nitrogen-Noble Gas Static Mass Spectrometry of Genesis Collector Materials. Neon Isotope Heterogeneity in the Terrestrial Mantle: Implication for the Acquisition of Volatile Elements in Terrestrial Planets. The Cosmic Clock, the Cycle of Terrestrial Mass Extinctions.

Source record↗

Low-Energy Sputtering Research

An experimental study is described to measure low-energy (less than 600 eV) sputtering yields of molybdenum with xenon ions using Rutherford backscattering spectroscopy (RBS) and secondary neutral mass spectroscopy (SNMS). An ion gun was used to generate the ion beam. The ion current density at the target surface was approximately 30 (micro)A/sq cm. For RBS measurements, the sputtered material was collected on a thin aluminum strip which was mounted on a semi-circular collector plate. The target was bombarded with 200 and 500 eV xenon ions at normal incidence. The differential sputtering yields were measured using the RBS method with 1 MeV helium ions. The differential yields were fitted with a cosine fitting function and integrated with respect to the solid angle to provide the total sputtering yields. The sputtering yields obtained using the RBS method are in reasonable agreement with those measured by other researchers using different techniques. For the SNMS measurements, 150 to 600 eV xenon ions were used at 50deg angle of incidence. The SNMS spectra were converted to sputtering yields for perpendicular incidence by normalizing SNMS spectral data at 500 eV with the yield measured by Rutherford backscattering spectrometry. Sputtering yields as well as the shape of the yield-energy curve obtained in this manner are in reasonable agreement with those measured by other researchers using different techniques. Sputtering yields calculated by using two semi-spherical formulations agree reasonably well with measured data. The isotopic composition of secondary ions were measured by bombarding copper with xenon ions at energies ranging from 100 eV to 1.5 keV. The secondary ion flux was found to be enriched in heavy isotopes at low incident ion energies. The heavy isotope enrichment was observed to decrease with increasing impact energy. Beyond 700 eV, light isotopes were sputtered preferentially with the enrichment remaining nearly constant.

Ray, P. K.↗

Transport of Highly Volatile Gases Related to Noble Gases and Tritium in the MSRE

This study aims to comprehend mass transfer in the closed-loop circulation of highly volatile gases, including noble gases and tritium. We explore the impact of steady-state xenon-135 and tritium on the MSRE and reveal their isotopic distributions using online noble gas stripping of fuel salts. The MSRE was engineered to extract fission product gases from fuel salts and efficiently eliminate inert gases with the help of helium bubbles within a circulating fuel pump. These reactors introduce significant theoretical challenges in estimating interfacial area and mass transfer coefficients, crucial for modeling mass transfer processes. An essential component of our analysis is the mass transfer coefficient. These coefficients are important for understanding how radionuclides move during various phase transitions within a nuclear reactor. Xenon-135 and tritium are found in both liquid and gas phases within the reactor system. In the liquid phase, they dissolve in molten salts, while in the gas phase, they manifest as bubbles. These elements have significant adverse effects on reactor operation due to their strong neutron absorption properties, influencing both safety and performance. The Mole code, which predicts the behavior of chemical species under steady-state conditions, facilitates multiphysics coupling with Griffin to update species distributions and address inherent MSR safety.

Lee, Kyoung↗

Troctolite 76535 - A study in the preservation of early isotopic records

The lunar rock considered in the present investigation is a coarse-grained troctolite granulite containing about 58(vol)% plagioclase, 37% olivine, 4% pyroxene, and less than 1% accessory phases with a texture which indicates formation as a cumulate at depths between 10 and 30 km followed by an extended period of slow cooling. A description is presented of noble gas studies of separated minerals from 76535. The quantity of fission xenon from the in situ decay of Pu-244 provides further evidence for different, mineral-specific, isotopic closure times. The presented data shows that 76535 loses its surface-correlated xenon component upon disaggregation. No other xenon component is lost. The presence of solar gases in 76535 would seem to argue in favor of the external acquisition of the parentless extinct isotope effects and consequently favor 'thermal diffusion' and 'adsorption' over local redistribution models.

Caffee, M.↗

Iodine Effects on Medical Isotope Producer Delay & Guard Bed Temperature and Performance in Support of NA-23 Program

In support of NA-23’s objective to accelerate the establishment of a reliable commercial United States (U.S.) domestic supply of 99Mo produced without the use of highly enriched uranium (HEU), the Pacific Northwest National Laboratory (PNNL) was tasked with modeling the performance of activated carbon delay and guard beds that may be typical for non-HEU 99Mo production processes. The specific tasks accomplished by PNNL included calculations of long-term effects of iodine on delay bed performance and development of a finite element simulation to better understand delay bed performance under various scenarios specifically with radioxenon and radioiodine decay heating of the delay beds. The main issue of interest in this study is understanding the effect of iodine on the abatement performance of the beds if iodine is not sufficiently removed from gases prior to reaching the delay beds. Finite element simulations of delay bed performance were developed using COMSOL Multiphysics® Software. These simulations are based on partial differential equations that describe xenon and iodine adsorption, heat transfer and decay of radioxenon and radioiodine isotopes. Heat transfer in the activated carbon beds is simulated with a heat source tied to the decay of radioactive xenon and iodine species. These simulations were used to investigate delay bed temperature and hold up time using radioxenon and radioiodine activities and flowrates expected from a non-HEU production process. A bounding case scenario was simulated, where all the iodine was released into the delay beds due to insufficient guarding of the delay beds. In addition, preliminary investigations of the guard beds were conducted.

07 ISOTOPE AND RADIATION SOURCES↗

Pressurized Lunar Rover (PLR)

The objective of this project was to design a manned pressurized lunar rover (PLR) for long-range transportation and for exploration of the lunar surface. The vehicle must be capable of operating on a 14-day mission, traveling within a radius of 500 km during a lunar day or within a 50-km radius during a lunar night. The vehicle must accommodate a nominal crew of four, support two 28-hour EVA's, and in case of emergency, support a crew of six when near the lunar base. A nominal speed of ten km/hr and capability of towing a trailer with a mass of two mt are required. Two preliminary designs have been developed by two independent student teams. The PLR 1 design proposes a seven meter long cylindrical main vehicle and a trailer which houses the power and heat rejection systems. The main vehicle carries the astronauts, life support systems, navigation and communication systems, lighting, robotic arms, tools, and equipment for exploratory experiments. The rover uses a simple mobility system with six wheels on the main vehicle and two on the trailer. The nonpressurized trailer contains a modular radioisotope thermoelectric generator (RTG) supplying 6.5 kW continuous power. A secondary energy storage for short-term peak power needs is provided by a bank of lithium-sulfur dioxide batteries. The life support system is partly a regenerative system with air and hygiene water being recycled. A layer of water inside the composite shell surrounds the command center allowing the center to be used as a safe haven during solar flares. The PLR 1 has a total mass of 6197 kg. It has a top speed of 18 km/hr and is capable of towing three metric tons, in addition to the RTG trailer. The PLR 2 configuration consists of two four-meter diameter, cylindrical hulls which are passively connected by a flexible passageway, resulting in the overall vehicle length of 11 m. The vehicle is driven by eight independently suspended wheels. The dual-cylinder concept allows articulated as well as double Ackermann steering. The primary power of 8 kW is supplied by a dynamic isotope system using a closed Brayton cycle with a xenon-hydrogen mixture as the working fluid. A sodium-sulfur battery serves as the secondary power source. Excess heat produced by the primary power system and other rover systems is rejected by radiators located on the top of the rear cylinder. The total mass of the PLR 2 is 7015 kg. Simplicity and low total weight have been the driving principles behind the design of PLR 1. The overall configuration consists of a 7-m-long, 3-m-diameter cylindrical main vehicle and a two-wheeled trailer. The cylinder of the main body is capped by eight-section, faceted, semi-hemispherical ends. The trailer contains the RTG power source and is not pressurized. The shell of the main body is constructed of a layered carbon fiber/foam/Kevlar sandwich structure. Included in the shell is a layer of water for radiation protection. The layer of water extends from the front of the rover over the crew compartment and creates a safe haven for the crew during a solar flare-up. The carbon fiber provides the majority of the strength and stiffness and the Kevlar provides protection from micrometeoroids. The Kevlar is covered with a gold foil and multi-layer insulation (MLI) to reduce radiation degradation and heat transfer through the wall. A thin thermoplastic layer seals the fiber and provides additional strength.

Creel, Kenneth↗

Phase II testing of Xenon International on Mount Schauinsland, Germany

Station RN33 on Mount Schauinsland near Freiburg, Germany, is part of the International Monitoring System monitoring radioxenon in air ( 131m Xe, 133 Xe, 133m Xe, and 135 Xe) for verification of the Comprehensive Nuclear Test Ban Treaty. Here, we present data from phase II testing of a new system, Xenon International at RN33, July 14th, 2021 to Jan 22nd, 2022, together with SPALAX data from the same time period. Radioxenon could be detected in 473 of 719 samples, among them many multiple isotope detections. Activity concentrations of spiked and selected environmental samples were verified by laboratory reanalysis. Finally, the sensitivity of Xenon International for radioxenons is up to one order of magnitude better for the metastable isotopes than that of the SPALAX, with a shorter sampling duration of 6 h.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Uncertainties in tellurium-based dark matter searches stemming from nuclear structure uncertainties

Using tellurium dioxide as a target, we calculate uncertainties on 90% upper confidence limits of Galilean effective field theory (Galilean EFT) couplings to a weakly interacting massive particle (WIMP) dark matter candidate due to uncertainties in nuclear shell models. We find that these uncertainties in naturally occurring tellurium isotopes are comparable across the different Galilean EFT couplings to uncertainties in xenon, with some reaching over 100%. We also consider the effect these nuclear uncertainties have on estimates of the annual modulation of dark matter from these searches, finding that the uncertainties in the modulation amplitude are proportional to the nonmodulating upper confidence limit uncertainties. We also show that the determination of the modulation phase is insensitive to changes in the nuclear model for a given isotope.

79 ASTRONOMY AND ASTROPHYSICS↗