Search NASA⌕ Search

SEARCH · Search NASA

Results for “Acceleration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Analysis of cell-based diffusion acceleration for the slice balance approach

In this work, we perform analysis on the use of cell-based diffusion acceleration methodologies to accelerate the convergence of transport solutions discretized with the slice balance approach (SBA) on unstructured polygonal grids.We investigated both linear diffusion synthetic acceleration (DSA) and non linear diffusion acceleration (NDA), including its partial-current variant (pNDA). DSA and NDA were both shown to diverge for intermediate ranges of mesh optical thicknesses. However, pNDA and Krylov methods like GMRES and Broyden stabilized the acceleration schemes, including problems with degenerate cells formed by mesh refinement. (author)

42 ENGINEERING↗

Constraints on models for the initial collision geometry in ultrarelativistic heavy ion collisions

Monte Carlo simulations are used to compute the centrality dependence of the collision zone eccentricities (epsilon{sub 2,4}), for both spherical and deformed ground state nuclei, for different model scenarios. Sizable model dependent differences are observed. They indicate that measurements of the second and fourth order Fourier flow coefficients v{sub 2,4}, expressed as the ratio (v{sub 4}/(v{sub 2}){sup 2}), can provide robust constraints for distinguishing between different theoretical models for the initial-state eccentricity. Such constraints could remove one of the largest impediments to a more precise determination of the specific viscosity from precision v{sub 2,4} measurements at the Relativistic Heavy Ion Collider (RHIC).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Manycore Parallel Computing for a Hybridizable Discontinuous Galerkin Nested Multigrid Method

In this work, we present a parallel computing strategy for a hybridizable discontinuous Galerkin (HDG) nested geometric multigrid (GMG) solver. Parallel GMG solvers require a combination of coarse-grain and fine-grain parallelism to improve time-to-solution performance. In this work we focus on fine-grain parallelism. We use Intel's second generation Xeon Phi (Knights Landing) manycore processor. The GMG method achieves ideal convergence rates of 0.2 or less, for high polynomial orders. A matrix free (assembly free) technique is exploited to save considerable memory usage and increase arithmetic intensity. HDG enables static condensation, and due to the discontinuous nature of the discretization, we developed a matrix vector multiply routine that does not require any costly synchronizations or barriers. Our algorithm is able to attain 80% of peak bandwidth performance for higher order polynomials. This is possible due to the data locality inherent in the HDG method. Very high performance is realized for high order schemes, due to good arithmetic intensity, which declines as the order is reduced.

97 MATHEMATICS AND COMPUTING↗

On Monte Carlo modeling of megavoltage photon beams: A revisited study on the sensitivity of beam parameters

Purpose: To commission Monte Carlo beam models for five Varian megavoltage photon beams (4, 6, 10, 15, and 18 MV). The goal is to closely match measured dose distributions in water for a wide range of field sizes (from 2x2 to 35x35 cm{sup 2}). The second objective is to reinvestigate the sensitivity of the calculated dose distributions to variations in the primary electron beam parameters. Methods: The GEPTS Monte Carlo code is used for photon beam simulations and dose calculations. The linear accelerator geometric models are based on (i) manufacturer specifications, (ii) corrections made by Chibani and Ma [''On the discrepancies between Monte Carlo dose calculations and measurements for the 18 MV Varian photon beam,'' Med. Phys. 34, 1206-1216 (2007)], and (iii) more recent drawings. Measurements were performed using pinpoint and Farmer ionization chambers, depending on the field size. Phase space calculations for small fields were performed with and without angle-based photon splitting. In addition to the three commonly used primary electron beam parameters (E{sub AV} is the mean energy, FWHM is the energy spectrum broadening, and R is the beam radius), the angular divergence ({theta}) of primary electrons is also considered. Results: The calculated and measured dose distributions agreed to within 1% local difference at any depth beyond 1 cm for different energies and for field sizes varying from 2x2 to 35x35 cm{sup 2}. In the penumbra regions, the distance to agreement is better than 0.5 mm, except for 15 MV (0.4-1 mm). The measured and calculated output factors agreed to within 1.2%. The 6, 10, and 18 MV beam models use {theta}=0 deg., while the 4 and 15 MV beam models require {theta}=0.5 deg. and 0.6 deg., respectively. The parameter sensitivity study shows that varying the beam parameters around the solution can lead to 5% differences with measurements for small (e.g., 2x2 cm{sup 2}) and large (e.g., 35x35 cm{sup 2}) fields, while a perfect agreement is maintained for the 10x10 cm{sup 2} field. The influence of R on the central-axis depth dose and the strong influence of {theta} on the lateral dose profiles are demonstrated. Conclusions: Dose distributions for very small and very large fields were proved to be more sensitive to variations in E{sub AV}, R, and {theta} in comparison with the 10x10 cm{sup 2} field. Monte Carlo beam models need to be validated for a wide range of field sizes including small field sizes (e.g., 2x2 cm{sup 2}).

43 PARTICLE ACCELERATORS↗

SU-E-T-226: Junction Free Craniospinal Irradiation in Linear Accelerator Using Volumetric Modulated Arc Therapy : A Novel Technique Using Dose Tapering

Purpose: Spatially separated fields are required for craniospinal irradiation due to field size limitation in linear accelerator. Field junction shits are conventionally done to avoid hot or cold spots. Our study was aimed to demonstrate the feasibility of junction free irradiation plan of craniospinal irradiation (CSI) for Meduloblastoma cases treated in linear accelerator using Volumetric modulated arc therapy (VMAT) technique. Methods: VMAT was planned using multiple isocenters in Monaco V 3.3.0 and delivered in Elekta Synergy linear accelerator. A full arc brain and 40° posterior arc spine fields were planned using two isocentre for short (<1.3 meter height ) and 3 isocentres for taller patients. Unrestricted jaw movement was used in superior-inferior direction. Prescribed dose to PTV was achieved by partial contribution from adjacent beams. A very low dose gradient was generated to taper the isodoses over a long length (>10 cm) at the conventional field junction. Results: In this primary study five patients were planned and three patients were delivered using this novel technique. As the dose contribution from the adjacent beams were varied (gradient) to create a complete dose distribution, therefore there is no specific junction exists in the plan. The junction were extended from 10–14 cm depending on treatment plan. Dose gradient were 9.6±2.3% per cm for brain and 7.9±1.7 % per cm for spine field respectively. Dose delivery error due to positional inaccuracy was calculated for brain and spine field for ±1mm, ±2mm, ±3mm and ±5 mm were 1%–0.8%, 2%–1.6%, 2.8%–2.4% and 4.3%–4% respectively. Conclusion: Dose tapering in junction free CSI do not require a junction shift. Therefore daily imaging for all the field is also not essential. Due to inverse planning dose to organ at risk like thyroid kidney, heart and testis can be reduced significantly. VMAT gives a quicker delivery than Step and shoot or dynamic IMRT.

60 APPLIED LIFE SCIENCES↗

A prediction interval method for uncertainty quantification of regression models

This paper considers calculation of prediction intervals (PIs) by neural networks (NNs) for quantifying uncertainty in regression tasks, so as to provide fast, accurate and robust emulators to accelerate scientific simulations. We propose a novel method to learn lower and upper bounds of the PI using independent NNs without defining an exclusive loss. Our method requires no distributional assumption, does not introduce extra hyper-parameters, and can effectively identify out-of-distribution samples and quantify their uncertainty. We demonstrate advantages of our method using a benchmark problem and two real-world scientific applications.

Zhang, Pei↗

SU-E-T-03: 3D GPU-Accelerated Secondary Checks of Radiation Therapy Treatment Plans

Purpose: Redundant treatment verifications in conformal and intensity-modulated radiation therapy techniques are traditionally performed with single point calculations. New solutions can replace these checks with 3D treatment plan verifications. This work describes a software tool (Mobius3D, Mobius Medical Systems) that uses a GPU-accelerated collapsed cone algorithm to perform 3D independent verifications of TPS calculations. Methods: Mobius3D comes with reference beam models for common linear accelerators. The system uses an independently developed collapsed cone algorithm updated with recent enhancements. 144 isotropically-spaced cones are used for each voxel for calculations. These complex calculations can be sped up by using GPUs. Mobius3D calculate dose using DICOM information coming from TPS (CT, RT Struct, RT Plan RT Dose). DVH-metrics and 3D gamma tests can be used to compare both TPS and secondary calculations. 170 patients treated with all common techniques as 3DCFRT (including wedged), static and dynamic IMRT and VMAT have been successfully verified with this solution. Results: Calculation times are between 3–5 minutes for 3DCFRT treatments and 15–20 for most complex dMLC and VMAT plans. For all PTVs mean dose and 90% coverage differences are (1.12±0.97)% and (0.68±1.19)%, respectively. Mean dose discrepancies for all OARs is (0.64±1.00)%. 3D gamma (global, 3%/3 mm) analysis shows a mean passing rate of (97.8 ± 3.0)% for PTVs and (99.0±3.0)% for OARs. 3D gamma pasing rate for all voxels in CT has a mean value of (98.5±1.6)%. Conclusion: Mobius3D is a powerful tool to verify all modalities of radiation therapy treatments. Dose discrepancies calculated by this system are in good agreement with TPS. The use of reference beam data results in time savings and can be used to avoid the propagation of errors in original beam data into our QA system. GPU calculations permit enhanced collapsed cone calculations with reasonable calculation times.

60 APPLIED LIFE SCIENCES↗

SU-F-T-475: An Evaluation of the Overlap Between the Acceptance Testing and Commissioning Processes for Conventional Medical Linear Accelerators

Purpose: This work’s objective is to determine the overlap of processes, in terms of sub-processes and time, between acceptance testing and commissioning of a conventional medical linear accelerator and to evaluate the time saved by consolidating the two processes. Method: A process map for acceptance testing for medical linear accelerators was created from vendor documentation (Varian and Elekta). Using AAPM TG-106 and inhouse commissioning procedures, a process map was created for commissioning of said accelerators. The time to complete each sub-process in each process map was evaluated. Redundancies in the processes were found and the time spent on each were calculated. Results: Mechanical testing significantly overlaps between the two processes - redundant work here amounts to 9.5 hours. Many beam non-scanning dosimetry tests overlap resulting in another 6 hours of overlap. Beam scanning overlaps somewhat - acceptance tests include evaluating PDDs and multiple profiles but for only one field size while commissioning beam scanning includes multiple field sizes and depths of profiles. This overlap results in another 6 hours of rework. Absolute dosimetry, field outputs, and end to end tests are not done at all in acceptance testing. Finally, all imaging tests done in acceptance are repeated in commissioning, resulting in about 8 hours of rework. The total time overlap between the two processes is about 30 hours. Conclusion: The process mapping done in this study shows that there are no tests done in acceptance testing that are not also recommended to do for commissioning. This results in about 30 hours of redundant work when preparing a conventional linear accelerator for clinical use. Considering these findings in the context of the 5000 linacs in the United states, consolidating acceptance testing and commissioning would have allowed for the treatment of an additional 25000 patients using no additional resources.

60 APPLIED LIFE SCIENCES↗

King City Asbestos Corporation (KCAC) Mine Carbon Mineralization Field Test (Final Combined Report)

The overall objective of the KCAC carbon mineralization project is to determine the most successful approaches to CO 2 mineralization of asbestos-bearing serpentinite rocks and mine waste at the closed KCAC asbestos mine. The objectives of Budget Period 1 (BP1) are to characterize the site including, mineralogical and geochemical variability in site materials, baseline conditions including CO 2 flux and local climate, and to establish the designs for the second, experimental phase of the project. As described in Section 3 of this report, all tasks outlined in the Statement of Project Objective (SOPO) have been completed or are on schedule to be completed by the end of BP1. As described in Section 4, all success criteria and milestones have been met or will be met by the end of BP1. We conclude that the findings of BP1 strongly support moving to the second phase of the project to investigate methods to increase the rate of CO 2 mineralization. CO 2 flux monitoring during BP1 established an estimated baseline uptake of CO 2 over the 142,193 m 2 KCAC mine site of 147 and 179 metric tons CO 2 /yr using dynamic closed chamber and eddy covariance monitoring methods, respectively. Mineralogical analysis shows that the loose surficial waste material contains pyroaurite and minor hydromagnesite, indicating past carbon mineralization. Sediment samples at depths below 60 cm contained ~3 wt% brucite and localized high brucite contents of ~24 wt% were measured at depth, indicating significant unreacted material at relatively shallow depths. Together, these results demonstrate that despite prolonged exposure to the atmosphere, reactive material is still present and accessible and is naturally taking up atmospheric CO 2 . However, these natural rates are still well below rates that can be achieved by applying practices that can accelerate the CO 2 mineralization reaction. Designs for the Field-Testing Phase (BP2) of the project have been established, incorporating the findings of BP1. Based on results to date we have selected two methods to accelerate the rate of CO 2 mineralization, which we refer to as the Tilling Method and the Greenhouse Method. We hypothesize that these methods can increase the CO 2 mineralization rate by up to 5 times greater than the natural background rate measured in BP1. An Initial Lifecyle Assessment (LCA) and techno-economic analysis (TEA) were conducted for these two methods. The LCA concluded that the baseline version of the Greenhouse and Tilling methods at commercial scale are expected to achieve a CDR efficiency of 97% and 71%, respectively (cumulative, over 30 years of operation). Incorporating the net CO 2 removal rates calculated in the LCA, the TEA found the levelized, 30-year costs of the baseline Greenhouse and Tilling methods to be $\$$95/t-CO 2 and $\$$119/t-CO 2 , respectively, and that costs could be brought to well below $\$$100/t-CO 2 for either method by scaling up the volume of rock utilized. An initial EH&S Risk Assessment, evaluating the potential EH&S risks of the proposed carbon mineralization methods at commercial scale, was completed by LLNL EH&S professionals for these two methods.

58 GEOSCIENCES↗

Outer Radiation Belt Dynamics During the October 2012 Storm Revisited: Rapid Inward Radial Transport From a Dynamic Outer Boundary

Earth's outer radiation belt electron flux is highly variable and can be enhanced by over an order of magnitude over timescales less than one day, as observed during the October 2012 storm. Previous studies of this storm (e.g., Reeves et al., 2013, https://doi.org/10.1126/science.1237743) have invoked local acceleration to explain this. However, here, we argue that the observations can instead be explained by fast inward radial transport. One method often invoked to distinguish between these two acceleration processes is the existence of local peaks in electron phase space density (PSD) as a function of L* at fixed first, M, and second, K, adiabatic invariants. However, this method relies on the assumption that the evolution of the PSD as a function of L* occurs over timescales slower than the satellite orbital period. Here, high spatiotemporal resolution data from the Global Positioning System (GPS) spacecraft constellation is used to show that enhancements in the PSD occur during the October 2012 storm over short timescales not resolvable by the Van Allen Probes. In addition, Geostationary Operational Environmental Satellite spacecraft data also indicate that these enhancements are consistent with relativistic electron injections. A radial diffusion model is shown to reproduce the PSD dynamics observed by the Van Allen Probes, once rapid variations at the simulation outer boundary are included, consistent with GPS data. This verifies that apparently “locally growing” peaks in PSD along high apogee satellite orbits can be produced by fast inward radial transport without requiring the action of any local acceleration processes.

99 GENERAL AND MISCELLANEOUS↗

Investigations on the multiple-sector hard-copper X-band accelerating structures

The development of advanced, high gradient accelerating structures is one of the leading activity of the particle accelerator community. In the technological research of new construction methods for these devices, high-power testing is a critical step for the verification of their viability. Recent experiments showed that accelerating cavities made out of hard copper, fabricated without high-temperature processes, can achieve better performance as compared with soft copper ones. Recently, we have built cavities using Tungsten Inert Gas welding and the high-power experiments confirmed that this joining process is a robust and low-cost alternative to brazing or diffusion bonding. This is a good solution for high-gradient operation, with a gradient of about 150 MV/m in X-band, at a breakdown rate of 10 -3 /pulse/meter using a shaped RF pulse with a 150 ns flat part. We continue the design, construction and high power tests of three-cells standing-wave X-band accelerating cavities fabricated with a split-open geometry, made of hard copper and vacuum-sealed by welding. Our aim is the fabrication of accelerating structures made out of hard copper alloys by using innovative cost-effective technologies. Moreover, our method of multiple-sector structures opens the way to new technological approaches and design methods, for example providing the possibility of placing dampers of the parasitic higher-order modes. Such structures with dampers allow for acceleration of multi-bunch beams, both in standing and in travelling-wave accelerating modality. Here, this paper describes the design of two cavities made of multiple sectors that were fabricated at the Italian Institute for Nuclear Physics in Frascati, Italy (INFN-LNF), assembled by means of clamping and then joined with the Tungsten Inert Gas welding in order to preserve the hardness of the metal. These are three-cell standing-wave X-band accelerating cavities, to be operated in the π-mode. We report the low-power RF tests of the first one, made of two halves, and the RF design of the second one, made of four quadrants. Both structures were built for high-gradient tests at SLAC National Accelerator Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Algorithm advances and applications of time‐dependent first‐principles simulations for ultrafast dynamics

Abstract Far from equilibrium phenomenon is a central theme of contemporary material research. Such phenomenon can exhibit itself in atomic structure and dynamics, but very often it also happens as non‐equilibrium phenomenon in the electronic structure. In ab initio material simulation, density functional theory (DFT) has played an essential role in studying electronic ground state problems. For excited states, besides many‐body perturbation theory, another powerful tool is the time dependent DFT (TDDFT) method. In particular, the real‐time TDDFT (rt‐TDDFT) method can be used to simulate many non‐equilibrium phenomena directly. Here we introduce our works on some algorithm advances based on our recently rt‐TDDFT method. This method uses the plane‐wave basis set, and significantly accelerates its efficiency by increasing the time step from 0.1–1 as in traditional methods to 0.2–0.5 fs. The noncollinear magnetic moments and spin–orbit coupling have also been included in our rt‐TDDFT method. Furthermore, a Boltzmann‐TDDFT algorithm has been developed to solve the hot carrier overheating problem in Ehrenfest dynamics, and a natural orbital branching algorithm has been developed to overcome the mean‐field approximation in Ehrenfest dynamics nuclear trajectory, thus allows stochastic multiple paths in chemical reactions. Utilizing these methods, we have studied the photoinduced ultrafast demagnetization, ultrafast phase transition, energy transfer between plasmon and hot carriers, as well as the high‐energy ion implantation and low‐energy atomic diffusion in semiconductors. We believe the tools as the ones introduced here can enable us to study a wide range of phenomena which are of great interest in modern day material research. This article is categorized under: Structure and Mechanism > Computational Materials Science Electronic Structure Theory > Ab Initio Electronic Structure Methods Electronic Structure Theory > Density Functional Theory

Liu, Wen‐Hao↗

Angular streaking of betatron X-rays in a transverse density gradient laser-wakefield accelerator

In a plasma with a transverse density gradient, laser wavefront tilt develops gradually due to phase velocity differences in different plasma densities. The wavefront tilt leads to a parabolic trajectory of the plasma wakefield and hence the accelerated electron beam, which leads to an angular streaking of the emitted betatron radiation. In this way, the temporal evolution of the betatron X-ray spectra will be converted into angular “streak,” i.e., having a critical energy-angle correlation. An analytical model for the curved trajectory of a laser pulse in a transverse density gradient is presented. This gives the deflection angle of the electron beam and the betatron X-rays as a function of the plasma and laser parameters, and it was verified by particle-in-cell simulations. This angular streaking could be used as a single-shot diagnostic technique to reveal the temporal evolution of betatron X-ray spectra and hence the electron acceleration itself.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Democratizing uncertainty quantification

Uncertainty Quantification (UQ) is vital to safety-critical model-based analyses, but the widespread adoption of sophisticated UQ methods is limited by technical complexity. In this paper, we introduce UM-Bridge (the UQ and Modeling Bridge), a high-level abstraction and software protocol that facilitates universal interoperability of UQ software with simulation codes. It breaks down the technical complexity of advanced UQ applications and enables separation of concerns between experts. UM-Bridge democratizes UQ by allowing effective interdisciplinary collaboration, accelerating the development of advanced UQ methods, and making it easy to perform UQ analyses from prototype to High Performance Computing (HPC) scale. In addition, we present a library of ready-to-run UQ benchmark problems, all easily accessible through UM-Bridge. These benchmarks support UQ methodology research, enabling reproducible performance comparisons. We demonstrate UM-Bridge with several scientific applications, harnessing HPC resources even using UQ codes not designed with HPC support.

Benchmarks↗

A Comprehensive Comparison of Relativistic Particle Integrators

We compare relativistic particle integrators commonly used in plasma physics, showing several test cases relevant for astrophysics. Three explicit particle pushers are considered, namely, the Boris, Vay, and Higuera–Cary schemes. We also present a new relativistic fully implicit particle integrator that is energy conserving. Furthermore, a method based on the relativistic guiding center approximation is included. The algorithms are described such that they can be readily implemented in magnetohydrodynamics codes or Particle-in-Cell codes. Here, our comparison focuses on the strengths and key features of the particle integrators. We test the conservation of invariants of motion and the accuracy of particle drift dynamics in highly relativistic, mildly relativistic, and non-relativistic settings. The methods are compared in idealized test cases, i.e., without considering feedback onto the electrodynamic fields, collisions, pair creation, or radiation. The test cases include uniform electric and magnetic fields, ${\boldsymbol{E}}\times {\boldsymbol{B}}$ fields, force-free fields, and setups relevant for high-energy astrophysics, e.g., a magnetic mirror, a magnetic dipole, and a magnetic null. These tests have direct relevance for particle acceleration in shocks and in magnetic reconnection.

79 ASTRONOMY AND ASTROPHYSICS↗

A fast, matrix-based method to perform omnidirectional pressure integration

Abstract Experimentally-measured pressure fields play an important role in understanding many fluid dynamics problems. Unfortunately, pressure fields are difficult to measure directly with non-invasive, spatially resolved diagnostics, and calculations of pressure from velocity have proven sensitive to error in the data. Omnidirectional line integration methods are usually more accurate and robust to these effects as compared to implicit Poisson equations, but have seen slower uptake due to the higher computational and memory costs, particularly in 3D domains. This paper demonstrates how omnidirectional line integration approaches can be converted to a matrix inversion problem. This novel formulation uses an iterative approach so that the boundary conditions are updated each step, preserving the convergence behavior of omnidirectional schemes while also keeping the computational efficiency of Poisson solvers. This method is implemented in Matlab and also as a GPU-accelerated code in CUDA-C++. The behavior of the new method is demonstrated on 2D and 3D synthetic and experimental data. Three-dimensional grid sizes of up to 125 million grid points are tractable with this method, opening exciting opportunities to perform volumetric pressure field estimation from 3D PIV measurements.

42 ENGINEERING↗

Neutron generation using pyroelectric crystals

According to one embodiment, a method for producing a directed neutron beam includes producing a voltage of negative polarity of at least −100 keV on a surface of a deuterated or tritiated target in response to a temperature change of a pyroelectric crystal of less than about 40° C., the pyroelectric crystal having the deuterated or tritiated target coupled thereto, pulsing a deuterium ion source to produce a deuterium ion beam, accelerating the deuterium ion beam to the deuterated or tritiated target to produce a neutron beam, and directing the ion beam onto the deuterated or tritiated target to make neutrons using at least one of a voltage of the pyroelectric crystal, and a high gradient insulator (HGI) surrounding the pyroelectric crystal. The directionality of the neutron beam is controlled by changing the accelerating voltage of the system. Other methods are presented as well.

Tang, Vincent↗

SU-F-J-179: Commissioning Dosimetric Data of a New 2.5 Megavoltage Imaging Beam from a TrueBeam Linear

Purpose: Recently a new 2.5 megavoltage imaging beam has become available in a TrueBeam linear accelerator for image guidance. There is limited information available related to the beam characteristics. Commissioning dosimetric data of the new imaging is necessary for configuration of the beam in a treatment planning system in order to calculate imaging doses to patients resulting from this new imaging beam. The purpose of this study is to provide measured commissioning data recommended for a beam configuration in a treatment planning system. Methods: A recently installed TrueBeam linear accelerator is equipped with a new low energy photon beam with a nominal energy of 2.5 MV which provides better image quality in addition to other therapeutic megavoltage beams. Dosimetric characteristics of the 2.5 MV are measured for commissioning. An ionization chamber was used to measure dosimetric data including depth-dose curves and dose profiles at different depths for field sizes ranging from 5×5 cm{sup 2} to 40×40 cm{sup 2}. Results: Although the new 2.5 MV beam is a flattening-filter-free (FFF) beam, its dose profiles are much flatter compared to a 6 MV FFF beam. The dose decrease at 20 cm away from the central axis is less than 30% for a 40×40 cm{sup 2} field. This moderately lower dose at off-axis distances benefits the imaging quality. The values of percentage depth-dose (PDD) curves are 53% and 63% for 10×10 cm{sup 2} and 40×40 cm{sup 2} fields respectively. The measured beam output is 0.85 cGy/MU for a reference field size at depth 5 cm obtained according to the AAPM TG-51 protocol. Conclusion: This systematically measured commissioning data is useful for configuring the new imaging beam in a treatment planning system for patient imaging dose calculations resulting from the application of this 2.5 MV beam which is commonly set as a default in imaging procedures.

60 APPLIED LIFE SCIENCES↗