Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Digitral Down Conversion Technology for Tevatron Beam Line Tuner at FNAL

Fermilab is presently in Run II collider operations and is developing instrumentation to improve luminosity. Improving the orbit matching between accelerator components using a Beam Line Tuner (BLT) can improve the luminosity. Digital Down Conversion (DDC) has been proposed as a method for making more accurate beam position measurements. Fermilab has implemented a BLT system using a DDC technique to measure orbit oscillations during injections from the Main Injector to the Tevatron. The output of a fast ADC is downconverted and filtered in software. The system measures the x and y positions, the intensity, and the time of arrival for each proton or antiproton bunch, on a turn-by-turn basis, during the first 1024 turns immediately following injection. We present results showing position, intensity, and time of arrival for both injected and coasting beam. Initial results indicate a position resolution of {approx}20 to 40 microns and a phase resolution of {approx}25 ps.

43 PARTICLE ACCELERATORS↗

Modeling of the charge-state separation at ITEP experimental facility for material science based on a Bernas ion source

The experiment automation system is supposed to be developed for experimental facility for material science at ITEP, based on a Bernas ion source. The program CAMFT is assumed to be involved into the program of the experiment automation. CAMFT is developed to simulate the intense charged particle bunch motion in the external magnetic fields with arbitrary geometry by means of the accurate solution of the particle motion equation. Program allows the consideration of the bunch intensity up to 10{sup 10} ppb. Preliminary calculations are performed at ITEP supercomputer. The results of the simulation of the beam pre-acceleration and following turn in magnetic field are presented for different initial conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Brightness measurement of an electron impact gas ion source for proton beam writing applications

We are developing a high brightness nano-aperture electron impact gas ion source, which can create ion beams from a miniature ionization chamber with relatively small virtual source sizes, typically around 100 nm. A prototype source of this kind was designed and successively micro-fabricated using integrated circuit technology. Experiments to measure source brightness were performed inside a field emission scanning electron microscope. The total output current was measured to be between 200 and 300 pA. The highest estimated reduced brightness was found to be comparable to the injecting focused electron beam reduced brightness. This translates into an ion reduced brightness that is significantly better than that of conventional radio frequency ion sources, currently used in single-ended MeV accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Repetition Rate, LINAC-based Nuclear Resonance Fluorescence FY 2009 Final Report

Nuclear Resonance Fluorescence (NRF), which is possible for nuclei with atomic numbers greater than helium (Z=2), occurs when a nuclear level is excited by resonant absorption of a photon and subsequently decays by reemission of a photon. The excited nuclear states can become readily populated, provided the incident photon’s energy is within the Doppler-broadened width of the energy level being excited. Utilizing continuous energy photon spectra, as is characteristic of a bremsstrahlung photon beam, as the inspection source, ensures that at least some fraction of the impinging beam will contribute to the population of the excited energy levels in the material of interest. Upon de-excitation, either to the ground state or to a lower-energy excited state, the emitted fluorescence photon’s energy will correspond to the energy difference between the excited state and the state to which it decays. As each isotope inherently contains unique nuclear energy levels, the NRF states for each isotope are also unique. By exploiting this phenomenon, NRF photon detection provides a well-defined signature for identifying the presence of individual nuclear species. This report summarizes the second year (Fiscal Year [FY] 2009) of a collaborative research effort between Idaho National Laboratory, Idaho State University’s Idaho Accelerator Center, and Pacific Northwest National Laboratory. This effort focused on continuing to assess and optimize NRF-based detection techniques utilizing a slightly modified, commercially available, pulsed medical electron accelerator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon Reconstruction and Identification in CMS

We present the design strategies and status of the CMS muon reconstruction and identification identification software. Muon reconstruction and identification is accomplished through a variety of complementary algorithms. The CMS muon reconstruction software is based on a Kalman filter technique and reconstructs muons in the standalone muon system, using information from all three types of muon detectors, and links the resulting muon tracks with tracks reconstructed in the silicon tracker. In addition, a muon identification algorithm has been developed which tries to identify muons with high efficiency while maintaining a low probability of misidentification. The muon identification algorithm is complementary by design to the muon reconstruction algorithm that starts track reconstruction in the muon detectors. The identification algorithm accepts reconstructed tracks from the inner tracker and attempts to quantify the muon compatibility for each track using associated calorimeter and muon detector hit information. The performance status is based on detailed detector simulations as well as initial studies using cosmic muon data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon Irradiation Response on Ge and Al-Doped SiO{sub 2} Optical Fibres

Recently, research groups have reported a number of radiation effects on the applications of SiO{sub 2} optical fibres with possible use as dosimeter material because these optical fibre provide a good basis for medical radiation dosimetry. The objective of this study is to investigate the thermoluminescence response and fading characteristic for germanium and aluminium doped SiO{sub 2} optical fibres with photon irradiation. These optical fibres are placed in solid phantom and irradiated to 6 and 10 MV photon beam at dose ranging from 0.06 Gy to 0.24 Gy using Primus MLC 3339 linear accelerator at Hospital Sultan Ismail, Johor Bahru. In fading studies, the TL measurements were continued up to 14 days period. The optical fibres will produce glow curves whereby the information is then analyzed. Al and Ge-doped optical fibres have a linear dose-TL signal relationship that is proportionality between the TL signal and the doses. Comparison for TL response between different linear accelerator showed a good agreement because these optical fibres also have a linear dose-TL signal relationship even using different equipments.

36 MATERIALS SCIENCE↗

1972713

Energy-frontier particle accelerators are among the most exciting, complex, challenging, and expensive research instruments performing high precision measurements confirming the fundamentals of the physics and broadening new research horizons. Currently the highest energy machines (under design or commissioned), from multi-GeV to several TeV, (ILC, FCC, CLIC) capable of searching for the most basic building blocks of matter are either driven by circular or linear accelerators [1-6]. Here (see also [7,8]) we suggest a novel design of circular-linear accelerator based on the merging of the weakly emitting, low-energy storage rings and energy recovery linear accelerators. To enable the operation of such a system and in particular the energy recovery from spent, high-intensity beams the use of the dual-axis asymmetric cavities is suggested. Merging circular and linear systems, and applications of dual axes cavities, aims to resolve both scientific and societal challenges. The merge of the systems will allow: 1) maintain high beam quality, high luminosity, and high energy efficiency; 2) offer a ?flexible? energy management via ?separation? of the collider and storage rings operations; 3) attract private partners via use of the storage rings to drive the next generation of the photon factories. The concept presented can be potentially used to reach ultimate energy frontiers in high-energy physics as well as to drive next generation light sources. We note that the numbers which will be presented are for illustration purpose and can be improved further.

Konoplev, I.↗

Microwaves and particle accelerators: a fundamental link

John Cockcroft's splitting of the atom and Ernest Lawrence's invention of the cyclotron in the first half of the twentieth century ushered in the grand era of ever higher energy particle accelerators to probe deeper into matter. It also forged a link, bonding scientific discovery with technological innovation that continues today in the twenty first century. The development of radar and high power vacuum electronics, especially microwave power tubes like the magnetrons and the klystrons in the pre-second world war era, was instrumental in the rapid development of circular and linear charged particle accelerators in the second half of the twentieth century. We had harnessed the powerful microwave radio-frequency sources from few tens of MHz to up to 90 GHz spanning L-band to W-band frequencies. Simultaneously in the second half of the twentieth century, lasers began to offer very first opportunities of controlling charged particles at smaller resolutions on the scale of wavelengths of visible light. We also witnessed in this period the emergence of the photon and neutron sciences driven by accelerators built-by-design producing tailored and ultra-bright pulses of bright photons and neutrons to probe structure and function of matter from aggregate to individual molecular and atomic scales in unexplored territories in material and life sciences. As we enter the twenty first century, the race for ever higher energies, brightness and luminosity to probe atto-metric and atto-second domains of the ultra-small structures and ultra-fast processes continues. These developments depend crucially on yet further advancements in the production and control of high power and high frequency microwaves and light sources, often intricately coupled in their operation to the high energy beams themselves. We give a glimpse of the recent developments and innovations in the electromagnetic production and control of charged particle beams in the service of science and society. (author)

43 PARTICLE ACCELERATORS↗

Non-destructive single-pass low-noise detection of ions in a beamline

We have conceived, built, and operated a device for the non-destructive single-pass detection of charged particles in a beamline. The detector is based on the non-resonant pick-up and subsequent low-noise amplification of the image charges induced in a cylindrical electrode surrounding the particles’ beam path. The first stage of the amplification electronics is designed to be operated from room temperature down to liquid helium temperature. The device represents a non-destructive charge counter as well as a sensitive timing circuit. We present the concept and design details of the device. We have characterized its performance and show measurements with low-energy highly charged ions (such as Ar{sup 13+}) passing through one of the electrodes of a cylindrical Penning trap. This work demonstrates a novel approach of non-destructive, low noise detection of charged particles which is, depending on the bunch structure, suitable, e.g., for ion traps, low-energy beamlines or accelerator transfer sections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heavy Ion Radiation Effects Studies With Ion Photon Emission Microscopy

The development of a new radiation effects microscopy (REM) technique is crucial as emerging semiconductor technologies demonstrate smaller feature sizes and thicker back end of line (BEOL) layers. To penetrate these materials and still deposit sufficient energy into the device to induce single event effects, high energy heavy ions are required. Ion photon emission microscopy (IPEM) is a technique that utilizes coincident photons, which are emitted from the location of each ion impact to map out regions of radiation sensitivity in integrated circuits and devices, circumventing the obstacle of focusing high-energy heavy ions. Several versions of the IPEM have been developed and implemented at Sandia National Laboratories (SNL). One such instrument has been utilized on the microbeam line of the 6 MV tandem accelerator at SNL. Another IPEM was designed for ex-vacu use at the 88'' cyclotron at Lawrence Berkeley National Laboratory (LBNL). Extensive engineering is involved in the development of these IPEM systems, including resolving issues with electronics, event timing, optics, phosphor selection, and mechanics. The various versions of the IPEM and the obstacles, as well as benefits associated with each will be presented. In addition, the current stage of IPEM development as a user instrument will be discussed in the context of recent results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An interface for the direct coupling of small liquid samples to AMS

We describe the moving wire interface attached to the 1-MV AMS system at LLNL’s Center for Accelerator Mass Spectrometry for the analysis of nonvolatile liquid samples as either discrete drops or from the direct output of biochemical separatory instrumentation, such as high-performance liquid chromatography (HPLC). Discrete samples containing at least a few 10 s of nanograms of carbon and as little as 50 zmol 14 C can be measured with a 3–5% precision in a few minutes. The dynamic range of our system spans approximately 3 orders in magnitude. Sample to sample memory is minimized by the use of fresh targets for each discrete sample or by minimizing the amount of carbon present in a peak generated by an HPLC containing a significant amount of 14 C. As a result, liquid sample AMS provides a new technology to expand our biomedical AMS program by enabling the capability to measure low-level biochemicals in extremely small samples that would otherwise be inaccessible.

14C↗

Investigation of Calibrating Force Transducer Using Sinusoidal Force

Sinusoidal force calibration method was studied several years before at Physikalisch-Technische Bundesanstalt (PTB). A similar dynamic force calibration system is developed at Changcheng Institute of Metrology and Measurement (CIMM). It uses electro-dynamic shakers to generate dynamic force in the range from 1 N to 20 kN, and heterodyne laser interferometers are used for acceleration measurement. The force transducer to be calibrated is mounted on the shaker, and a mass block is screwed on the top of force transducer, the sinusoidal forces realized by accelerated load masses are traceable to acceleration and mass according to the force definition. The methods of determining Spatial-dependent acceleration on mass block and measuring the end mass of force transducer in dynamic force calibration are discussed in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a High-Energy Neutron Sniffer and Subsequent Dose Quantification for High-Energy Particle Accelerator Shielding Surveys

The objective of this research is to design a portable neutron detector that is lightweight and responds to neutrons with energies of 20 MeV and greater. The instrument will be used as a ‘sniffer’ probe for identifying shielding weaknesses at high-energy particle accelerators and be paired with a plastic scintillator to quantify the high-energy neutron dose equivalent. The sniffer probes are two different sizes and comprised of either cesium iodide or sodium iodide, all doped with thallium, making a total of four detectors. The probes were calibrated to respond only to radiations with 8 MeV electron equivalent energy or higher, vastly reducing detector response from background and lower energy radiations. The sniffer probes were tested using californium- 252 and americium-beryllium sources, followed by high-energy (up to 800 MeV) neutron exposures at the Los Alamos Neutron Science Center Weapons Neutron Research (WNR) facility. The sniffer probes were then used to identify areas around the accelerator facility where elevated levels of high-energy radiation was present and the plastic scintillators were placed in these locations to determine the high-energy neutron dose equivalent. The dose equivalent is calculated by measuring the 12 C(n,2n) 11 C reaction, which has a 20.4 MeV neutron threshold. Two locations behind the WNR facility were identified with the probes and the dose equivalent rates from neutron energies above 20 MeV were calculated to be 1.24 mrem/h behind flightpath 30-left and 1.53 behind flightpath 30-right. Of the four sniffer probes, the 2-inch x 2-inch cesium iodide is the recommended probe for performing high-energy shielding surveys. The larger crystal size yields higher sensitivity at lower count rates and the more dense material increases the likelihood of interaction within the crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Basic Research Needs for High Energy Physics Detector Research & Development: Report of the Office of Science Workshop on Basic Research Needs for HEP Detector Research and Development: December 11-14, 2019

Transformative discovery in science is driven by innovation in technology. Our boldest undertakings in particle physics have at their foundation precision instrumentation. To reveal the profound connections underlying everything we see from the smallest scales to the largest distances in the Universe, to understand its fundamental constituents, and to reveal what is still unknown, we must invent, develop, and deploy advanced instrumentation. Investments in High Energy Physics (HEP) enabled by instrumentation have been richly rewarded with discoveries of the tiny masses of the neutrinos, the origin of mass itself: the enigmatic Higgs boson, and the surprising accelerating expansion of the Universe. What we have learned is remarkable, unexpected, exciting and mysterious; raising many new questions waiting to be answered. The quest to answer them drives innovation that improves the nation's health, wealth, and security, inspiring the public and drawing young people to science. Excellence and innovation come most effectively from diverse teams of people. Success, therefore, depends critically on attracting, engaging, and supporting a diverse cadre of young people to the field, and ensuring an inclusive environment at all levels. The program laid out in the 2014 Particle Physics Projects Prioritization Panel (P5) report "Building for Discovery - A Strategic Plan for U.S. Particle Physics in a Global Context" guides current and near future experiments to exploit these and other discoveries, and the instrumentation innovation they require, to push the frontiers of science into new territory. To explore this territory HEP will soon embark on planning the next generation of experiments. Realizing these experiments will require giant leaps in capabilities beyond the instrumentation of today. Accordingly, now is a pivotal moment to invest in the accelerated development of cost-effective instrumentation with greatly improved sensitivity and performance that will make measurable the unmeasurable, enabling a tool-driven revolution to open the door to future discoveries. Historic scientific opportunities await us, enabled by executing the instrumentation research plan outlined here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement Of Gas Electron Multiplier (GEM) Detector Characteristics

The High Energy Physics group of the University of Texas at Arlington has been developing gas electron multiplier detectors to use them as sensitive gap detectors in digital hadron calorimeters for the International Linear Collider, a future high energy particle accelerator. For this purpose, we constructed numerous GEM detectors that employ double GEM layers. In this study, two kinds of prototype GEM detectors were tested; one with 28x28 cm{sup 2} active area double GEM structure with a 3 mm drift gap, a 1 mm transfer gap and a 1 mm induction gap and the other with two 3x3 cm{sup 2} GEM foils in the amplifier stage with a 5 mm drift gap, a 2 mm transfer gap and a 1 mm induction gap. The detectors' characteristics from exposure to high-energy charged particles and other radiations were measured using cosmic rays and {sup 55}Fe radioactive source. From the {sup 55}Fe tests, we observed two well separated characteristic X-ray emission peaks and confirmed the detectors' functionality. We also measured chamber gains to be over 6000 at a high voltage of 395 V across each GEM electrode. The responses to cosmic rays show the spectra that fit well to Landau distributions as expected from minimum ionizing particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a fast digital integrator in on-field magnetic measurements for particle accelerators

The fast digital integrator has been conceived to face most demanding magnet test requirements with a resolution of 10 ppm, a signal-to-noise ratio of 105 dB at 20 kHz, a time resolution of 50 ns, an offset of 10 ppm, and on-line processing. In this paper, the on-field achievements of the fast digital integrator are assessed by a specific measurement campaign at the European Organization for Nuclear Research (CERN). At first, the architecture and the metrological specifications of the instrument are reported. Then, the recent on-field achievements of (i) {+-}10 ppm of uncertainty in the measurement of the main field for superconducting magnets characterization, (ii) {+-}0.02 % of field uncertainty in quality assessment of small-aperture permanent magnets, and (iii) {+-}0.15 % of drift, in an excitation current measurement of 600 s under cryogenic conditions, are presented and discussed.

43 PARTICLE ACCELERATORS↗

Conceptual design of a heavy ion beam probe diagnostic for the Wendelstein 7-X Stellarator

This article describes the current state of the design of the heavy ion beam probe (HIBP) for Wendelstein 7-X (W7-X). It will be the first HIBP diagnostic on an optimized stellarator and is designed to study electric fields and ion scale turbulence in all W7-X reference magnetic configurations. The use of an existing 2 MV accelerator, located outside of the torus hall, results in the need for a circuitous primary beamline. This increases the complexity of the ion optics design to deliver a focused beam to the plasma. To access most of the magnetic configuration space of W7-X, the secondary beamline and an energy analyzer are designed to pivot, thereby redirecting a wider range of secondary beam trajectories. Signal level estimates indicate that the equilibrium potential can be measured at all radii and that the radial coverage for potential and density fluctuations measurements depends on the plasma density.

47 OTHER INSTRUMENTATION↗

The McDonald Accelerating Stars Survey (MASS): White Dwarf Companions Accelerating the Sun-like Stars 12 Psc and HD 159062

We present the discovery of a white dwarf companion to the G1 V star 12 Psc found as part of a Keck adaptive optics imaging survey of long-term accelerating stars from the McDonald Observatory Planet Search Program. Twenty years of precise radial-velocity monitoring of 12 Psc with the Tull Spectrograph at the Harlan J. Smith telescope reveals a moderate radial acceleration (≈10 m s{sup −1} yr {sup −1}), which together with relative astrometry from Keck/NIRC2 and the astrometric acceleration between Hipparcos and Gaia DR2 yields a dynamical mass of M {sub B} = 0.605{sub −0.022}{sup +0.021} M {sub ⊙} for 12 Psc B, a semimajor axis of 40{sub −4}{sup +2} au, and an eccentricity of 0.84 ± 0.08. We also report an updated orbital fit of the white dwarf companion to the metal-poor (but barium-rich) G9 V dwarf HD 159062 based on new radial-velocity observations from the High-Resolution Spectrograph at the Hobby–Eberly Telescope and astrometry from Keck/NIRC2. A joint fit of the available relative astrometry, radial velocities, and tangential astrometric acceleration yields a dynamical mass of M {sub B} = 0.609{sub −0.011}{sup +0.010} M {sub ⊙} for HD 159062 B, a semimajor axis of 60{sub −7}{sup +5} au, and preference for circular orbits (e < 0.42 at 95% confidence). 12 Psc B and HD 159062 B join a small list of resolved Sirius-like benchmark white dwarfs with precise dynamical mass measurements which serve as valuable tests of white dwarf mass–radius cooling models and probes of AGB wind accretion onto their main-sequence companions.

47 OTHER INSTRUMENTATION↗