Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atomic Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Laser spectroscopy of indium Rydberg atom bunches by electric field ionization

This work reports on the application of a novel electric field-ionization setup for high-resolution laser spectroscopy measurements on bunched fast atomic beams in a collinear geometry. In combination with multi-step resonant excitation to Rydberg states using pulsed lasers, the field ionization technique demonstrates increased sensitivity for isotope separation and measurement of atomic parameters over previous non-resonant laser ionization methods. The setup was tested at the Collinear Resonance Ionization Spectroscopy experiment at ISOLDE-CERN to perform high-resolution measurements of transitions in the indium atom from the 5s 2 5d 2 D 5/2 and 5s 2 5d 2 D 3/2 states to 5s 2 np 2 P and 5s 2 nf 2 F Rydberg states, up to a principal quantum number of n=72 . The extracted Rydberg level energies were used to re-evaluate the ionization potential of the indium atom to be 46,670.107(4)cm -1 . The nuclear magnetic dipole and nuclear electric quadrupole hyperfine structure constants and level isotope shifts of the 5s 2 5d 2 D 5/2 and 5s 2 5d 2 D 3/2 states were determined for 113,115 In. The results are compared to calculations using relativistic coupled-cluster theory. A good agreement is found with the ionization potential and isotope shifts, while disagreement of hyperfine structure constants indicates an increased importance of electron correlations in these excited atomic states. With the aim of further increasing the detection sensitivity for measurements on exotic isotopes, a systematic study of the field-ionization arrangement implemented in the work was performed at the same time and an improved design was simulated and is presented. The improved design offers increased background suppression independent of the distance from field ionization to ion detection.

74 ATOMIC AND MOLECULAR PHYSICS↗

Molecules in Cool Stars: The A 2 Π − X 2 Σ + and the B 2 Σ + − X 2 Σ + Band Systems of CaCl

Cool red giant stars exhibit absorption bands of calcium monochloride (CaCl) in the optical region. In this work, the bands of CaCl corresponding to the A 2 Π − X 2 Σ + transition with v' ≤ 4 and v'' ≤ 4, and B 2 Σ + − X 2 Σ + transition with v' ≤ 2 and v'' ≤ 2 are rotationally analyzed with PGOPHER, a multipurpose program for simulating and fitting molecular spectra. All bands were analyzed using high-resolution absorption spectra collected at the National Solar Observatory in 1985, calibrated with atomic lines from a high-resolution emission spectrum obtained in a separate hollow cathode experiment. The results are compared with previous laser-induced fluorescence measurements. Overall, the accuracy of spectroscopic constants for the A2Π and B2Σ+ states is improved. Scaled transition dipole moment calculations were used to obtain line strengths. Line lists are provided with Einstein A coefficients and oscillator strengths, which can be used to determine CaCl stellar abundances. Additionally, isotope splittings allowed us to estimate band origins for the 40 Ca 37 Cl isotopologue based on band-head positions.

Léo Lavy↗

A high-resolution vacuum ultraviolet laser photoionization and photoelectron study of the Co atom

We have measured the vacuum ultraviolet–photoionization efficiency (VUV–PIE) spectrum of Co in the energy range of 63,500–67,000 cm{sup −1}, which covers the photoionization transitions of Co(3d{sup 7}4s{sup 2 4}F{sub 9/2}) → Co{sup +}(3d{sup 8 3}F{sub 4}), Co(3d{sup 7}4s{sup 2 4}F{sub 7/2}) → Co{sup +}(3d{sup 8 3}F{sub 3}), Co(3d{sup 7}4s{sup 2 4}F{sub 9/2}) → Co{sup +}(3d{sup 8 3}F{sub 3}), Co(3d{sup 7}4s{sup 2 4}F{sub 9/2}) → Co{sup +}(3d{sup 8 3}F{sub 2}), and Co(3d{sup 7}4s{sup 2 4}F{sub 9/2}) → Co{sup +}(3d{sup 7}4s{sup 1 5}F{sub 5}). We have also recorded the pulsed field ionization photoelectron spectrum of Co in the same energy range, allowing accurate determinations of ionization energies (IEs) for the photoionization transitions from the Co(3d{sup 7}4s{sup 2 4}F{sub 9/2}) ground neutral state to the Co{sup +}({sup 3}F{sub J}) (J = 4 and 3) and Co{sup +}({sup 5}F{sub 5}) ionic states, as well as from the Co(3d{sup 7}4s{sup 2 4}F{sub 7/2}) excited neural state to the Co{sup +}(3d{sup 8 3}F{sub 3}) ionic state. The high-resolution nature of the VUV laser used has allowed the observation of many well-resolved autoionizing resonances in the VUV–PIE spectrum, among which an autoionizing Rydberg series, 3d{sup 7}4s{sup 1}({sup 5}F{sub 5})np (n = 19–38), converging to the Co{sup +}(3d{sup 7}4s{sup 1 5}F{sub 5}) ionic state from the Co(3d{sup 7}4s{sup 2 4}F{sub 9/2}) ground neutral state is identified. The fact that no discernible step-like structures are present at these ionization thresholds in the VUV–PIE spectrum indicates that direct photoionization of Co is minor compared to autoionization in this energy range. The IE values, the autoionizing Rydberg series, and the photoionization cross sections obtained in this experiment are valuable for understanding the VUV opacity and abundance measurement of the Co atom in stars and solar atmospheres, as well as for benchmarking the theoretical results calculated in the Opacity Project and the IRON Project, and thus are of relevance to astrophysics.

79 ASTRONOMY AND ASTROPHYSICS↗

Mapping of Proteomic Composition on the Surfaces of Bacillus spores by Atomic Force Microscopy-based Immunolabeling

Atomic force microscopy provides a unique capability to image high-resolution architecture and structural dynamics of pathogens (e.g. viruses, bacteria and bacterial spores) at near molecular resolution in native conditions. Further development of atomic force microscopy in order to enable the correlation of pathogen protein surface structures with specific gene products is essential to understand the mechanisms of the pathogen life cycle. We have applied an AFM-based immunolabeling technique for the proteomic mapping of macromolecular structures through the visualization of the binding of antibodies, conjugated with nanogold particles, to specific epitopes on Bacillus spore surfaces. This information is generated while simultaneously acquiring the surface morphology of the pathogen. The immunospecificity of this labeling method was established through the utilization of specific polyclonal and monoclonal antibodies that target spore coat and exosporium epitopes of Bacillus atrophaeus and Bacillus anthracis spores.

59 BASIC BIOLOGICAL SCIENCES↗

Threshold photoelectron source for the study of low-energy electron scattering: Total cross section for electron scattering from krypton in the energy range from 14 meV to 20 eV

An experimental technique for the measurement of the total cross section for electron scattering from atoms and molecules at high resolution is described. The total cross sections for electron scattering from Kr in the energy range from 14 meV to 20 eV obtained with the technique are also reported. The present technique employs a combination of the penetrating field technique and the threshold photoionization of rare-gas atoms using synchrotron radiation as an electron source in order to produce a high-resolution electron beam at very low energy. The characteristics of the electron sources were determined by measuring the ionizing photon energy dependence of photoelectron yield. Absolute total cross sections for electron scattering are obtained by the attenuation method. The measured absolute values of the total cross sections for electron scattering from Kr agree with those obtained by other groups down to 175 meV, above which several experimental works have been reported. Below 175 meV, the present results generally agree with theoretical cross sections down to 14 meV. The resonant structures in the total cross sections due to Kr{sup -} (4p{sup 5}5s{sup 2} {sup 2}P{sub 3/2}) and the Kr{sup -} (4p{sup 5}5s{sup 2} {sup 2}P{sub 1/2}) Feshbach resonances are also reported. The resolution of the present setup has been estimated from a fit of the measured profile of the Kr{sup -} (4p{sup 5}5s{sup 2} {sup 2}P{sub 3/2}) resonance by the theoretical curve obtained from the resonant scattering theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A high-dispersion molecular gas component in nearby galaxies

We present a comprehensive study of the velocity dispersion of the atomic (H I) and molecular (H{sub 2}) gas components in the disks (R ≲ R {sub 25}) of a sample of 12 nearby spiral galaxies with moderate inclinations. Our analysis is based on sensitive high-resolution data from the THINGS (atomic gas) and HERACLES (molecular gas) surveys. To obtain reliable measurements of the velocity dispersion, we stack regions several kiloparsecs in size, after accounting for intrinsic velocity shifts due to galactic rotation and large-scale motions. We stack using various parameters: the galactocentric distance, star formation rate surface density, H I surface density, H{sub 2} surface density, and total gas surface density. We fit single Gaussian components to the stacked spectra and measure median velocity dispersions for H I of 11.9 ± 3.1 km s{sup –1} and for CO of 12.0 ± 3.9 km s{sup –1}. The CO velocity dispersions are thus, surprisingly, very similar to the corresponding ones of H I, with an average ratio of σ{sub HI}/σ{sub CO}= 1.0 ± 0.2 irrespective of the stacking parameter. The measured CO velocity dispersions are significantly higher (factor of ∼2) than the traditional picture of a cold molecular gas disk associated with star formation. The high dispersion implies an additional thick molecular gas disk (possibly as thick as the H I disk). Our finding is in agreement with recent sensitive measurements in individual edge-on and face-on galaxies and points toward the general existence of a thick disk of molecular gas, in addition to the well-known thin disk in nearby spiral galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Scanning Quantum Cryogenic Atom Microscope

Microscopic imaging of local magnetic fields provides a window into the organizing principles of complex and technologically relevant condensed-matter materials. However, a wide variety of intriguing strongly correlated and topologically nontrivial materials exhibit poorly understood phenomena outside the detection capability of state-of-the-art high-sensitivity high-resolution scanning probe magnetometers. We introduce a quantum-noise-limited scanning probe magnetometer that can operate from room-to-cryogenic temperatures with unprecedented dc-field sensitivity and micron-scale resolution. The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) employs a magnetically levitated atomic Bose-Einstein condensate (BEC), thereby providing immunity to conductive and blackbody radiative heating. The SQCRAMscope has a field sensitivity of 1.4 nT per resolution-limited point (approximately 2 μm) or 6 nT/√Hz per point at its duty cycle. Furthermore, compared to point-by-point sensors, the long length of the BEC provides a naturally parallel measurement, allowing one to measure nearly 100 points with an effective field sensitivity of 600 pT/√Hz for each point during the same time as a point-by-point scanner measures these points sequentially. Moreover, it has a noise floor of 300 pT and provides nearly 2 orders of magnitude improvement in magnetic flux sensitivity (down to 10 -6 Φ 0 /√Hz) over previous atomic probe magnetometers capable of scanning near samples. These capabilities are carefully benchmarked by imaging magnetic fields arising from microfabricated wire patterns in a system where samples may be scanned, cryogenically cooled, and easily exchanged. We anticipate the SQCRAMscope will provide charge-transport images at temperatures from room temperature to 4 K in unconventional superconductors and topologically nontrivial materials.

74 ATOMIC AND MOLECULAR PHYSICS↗

Complete resolution across the neodymium/samarium isotopic envelope with a liquid sampling‐atmospheric pressure glow discharge — Orbitrap mass spectrometer

Rationale Nd and Sm isotope ratios play an important role in geological dating and as nuclear forensic signatures; however, the overlap of the respective 144, 148, 150 Nd/Sm isobars requires prior separations to be performed before analysis on typical MS platforms. The work presented here overcomes these isobaric interferences using ultrahigh‐mass resolution to alleviate interference without prior chemical separations. Methods A liquid sampling‐atmospheric pressure glow discharge ion source was coupled to a standard, QExactive Focus Orbitrap mass spectrometer, providing a mass resolution of ~80 k. A Spectroswiss FTMS booster X2 data acquisition package was used to collect extended transients, providing much higher mass resolution; ~230 k and ~600 k are employed here for Nd and Sm isotopes. Results While the standard Orbitrap resolution is far greater than typical “atomic” MS platforms, it was insufficient to alleviate all isobars. The use of a resolution of ~230 k resulted in baseline separation across the entire isotopic envelope for both Nd and Sm. Isotope ratios obtained from Nd:Sm mixtures using high‐resolution were equivalent to those found for individual‐element solutions, while isotope ratios obtained at a resolution of ~80 k (standard for the OEM data system) showed large deviations. Conclusions Use of ultrahigh‐resolution is an attractive alternative to extensive chemical separations to alleviate severe isobaric interferences. Sufficient mass resolution greatly reduces/eliminates the need for sample manipulations (separations) before analysis while reducing costs and total analysis times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Demonstration of an AI-driven workflow for autonomous high-resolution scanning microscopy

Abstract Modern scanning microscopes can image materials with up to sub-atomic spatial and sub-picosecond time resolutions, but these capabilities come with large volumes of data, which can be difficult to store and analyze. We report the Fast Autonomous Scanning Toolkit (FAST) that addresses this challenge by combining a neural network, route optimization, and efficient hardware controls to enable a self-driving experiment that actively identifies and measures a sparse but representative data subset in lieu of the full dataset. FAST requires no prior information about the sample, is computationally efficient, and uses generic hardware controls with minimal experiment-specific wrapping. We test FAST in simulations and a dark-field X-ray microscopy experiment of a WSe 2 film. Our studies show that a FAST scan of <25% is sufficient to accurately image and analyze the sample. FAST is easy to adapt for any scanning microscope; its broad adoption will empower general multi-level studies of materials evolution with respect to time, temperature, or other parameters.

47 OTHER INSTRUMENTATION↗

Electron Tomography: Seeing Atoms in Three Dimensions

Our eyes - a parallel lens system - have the phenomenal ability to observe and "reconstruct" the three-dimensional world, relaying a 3-D image to our brains. Imaging of the nanoworld is best done with electrons rather than photons because of their lower wavelengths and higher resolution. The advent of aberration-correction has led to transmission electron microscopes with sub-Angstrom resolution that can resolve single atoms. Yet, no matter what detector is used, the resulting images are only two-dimensional projections of three-dimensional objects. Electron tomography is a technique that allows reconstruction of the three-dimensional structure and morphology of nanomaterials from such projections. X-ray tomography has been used in many branches of science for nearly half a century, and in the biological sciences electron tomography has been a powerful tool for understanding ultrastructure. However, for many years crystalline materials posed a challenge to electron tomography because diffraction contrast (a change in intensity in the image at particular crystal orientations) creates artifacts in the 3-D reconstruction. In 2003, with advances in scanning transmission electron microscopy, Midgley and colleagues obtained the first electron tomograms of crystalline materials. Shortly thereafter, Arslan et al. showed that the spatial resolution could be improved to 1 nm in all three spatial dimensions and visualized the formation of faceted 3.5-nm quantum dots embedded in a Si matrix. However, with that work existing reconstruction algorithms appeared to have reached their limit. To attain a resolution of 1 nm, a total of 140 images over ±78 degrees of tilt were needed. Writing in Nature Materials, Goris et al. now report a novel algorithm for 3-D reconstruction of the atomic structure of free-standing Au nanorods, using only four projection images. I.A. acknowledges collaboration with J.D. Roehling, K.J. Batenburg, B.C. Gates and A. Katz for Figure 1, supported in part by the DOE BES DE-SC0005822, and in part by the LDRD program at PNNL. The Pacific Northwest National Laboratory is operated by Battelle under contract DE-AC05-76RL01830.

Arslan, Ilke↗

Ultrafast self-gating Bragg diffraction of exploding nanocrystals in an X-ray laser

In structural determination of crystalline proteins using intense femtosecond X-ray lasers, damage processes lead to loss of structural coherence during the exposure. We use a nonthermal description for the damage dynamics to calculate the ultrafast ionization and the subsequent atomic displacement. These effects degrade the Bragg diffraction on femtosecond time scales and gate the ultrafast imaging. This process is intensity and resolution dependent. At high intensities the signal is gated by the ionization affecting low resolution information first. At lower intensities, atomic displacement dominates the loss of coherence affecting high-resolution information. We find that pulse length is not a limiting factor as long as there is a high enough X-ray flux to measure a diffracted signal.

47 OTHER INSTRUMENTATION↗

Synchrotron Facilities: Vibration and Stability Challenge

The new generation of synchrotron accelerator facilities are opening exciting new opportunities in imaging, spectroscopy, structural and dynamic studies, and other applications by pushing the envelope of resolution to just a few nanometers and possibly atomic scale (~1 nm). Achieving such a state of resolution in both space and energy is expected to have broad impact on a wide range of disciplines and scientific initiatives in the coming decades, including new studies of small crystals in structural biology, a wide range of nanometer-resolution probes for nanoscience, properties of materials under extreme conditions, etc. Such performance goals place severe requirements on the quality of the electron and photon beams. Within the synchrotron accelerator envelope, and in addition to the need to maintain the electron beam within an extremely stable orbit in order to realize the benefits of the high brightness and small beam sizes, it is essential that the photon beams are also exceedingly stable in both position and angle. Particularly for timing experiments, it is also necessary that the arrival-time jitter of the bunch be small. Transverse beam motions <10% of beam size or angular spread, and longitudinal beam motion of <5% of equilibrium bunch duration, are typically desired. Ideally, the temporal, spatial, and angular stability of the electron beam should be maintained for at least the duration of spectral scans, which typically run from a few milliseconds to a few hours. Achieving such a level of stability that is ever pushing the envelope is an enormous task, and that is where engineering comes into play.

36 MATERIALS SCIENCE↗

Atomic scale observation of phase separation and formation of silicon clusters in Hf higk-{kappa} silicates

Hafnium silicate films were fabricated by RF reactive magnetron sputtering technique. Fine microstructural analyses of the films were performed by means of high-resolution transmission electron microscopy and atom probe tomography. A thermal treatment of as-grown homogeneous films leads to a phase separation process. The formation of SiO{sub 2} and HfO{sub 2} phases as well as pure Si one was revealed. This latter was found to be amorphous Si nanoclusters, distributed uniformly in the film volume. Their mean diameter and density were estimated to be about 2.8 nm and (2.9 {+-} 0.4) x 10{sup 17} Si-ncs/cm{sup 3}, respectively. The mechanism of the decomposition process was proposed. The obtained results pave the way for future microelectronic and photonic applications of Hf-based high-{kappa} dielectrics with embedded Si nanoclusters.

36 MATERIALS SCIENCE↗

Bright Semiconductor Scintillator for High Resolution X-Ray Imaging

We report on a novel approach to produce oxygen-doped zinc telluride (ZnTe:O), a remarkable group II-VI semiconductor scintillator, fabricated in the columnar-structured or polycrystalline forms needed to fulfill the needs of many demanding X-ray and {gamma}-ray imaging applications. ZnTe:O has one of the highest conversion efficiencies among known scintillators, emission around 680 nm (which is ideally suited for CCD sensors), high density of 6.4 g/cm{sup 3}, fast decay time of {approx}1 {micro}s with negligible afterglow, and orders of magnitude higher radiation resistance compared to commonly used scintillators. These properties allow the use of ZnTe:O in numerous applications, including X-ray imaging, nuclear medicine (particularly SPECT), room temperature radioisotope identification, and homeland security. Additionally, ZnTe:O offers distinct advantages for synchrotron-based high resolution imaging due to the absence of atomic absorption edges in the low energy range, which otherwise reduce resolution due to secondary X-ray formations. We have fabricated films of ZnTe:O using a vapor deposition technique that allows large-area structured scintillator fabrication in a time- and cost-efficient manner, and evaluated its performance for small-angle X-ray scattering (SAXS) at an Argonne National Laboratory synchrotron beamline. Details of the fabrication and characterization of the optical, scintillation and imaging properties of the ZnTe:O films are presented in this paper.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Applications of SPM to Studies of Mineral–Water Interface Chemistry

The scanning probe microscope (SPM) has been utilized in studies of solid surfaces for nearly four decades. With resolution as high as the single atom level, valuable information on the structure and other properties of solid surfaces can be obtained. One of the most exciting areas of application for the SPM is in the study of mineral–water interfaces where the chemical reactions taking place are both of fundamental interest as well as important from an environmental/geochemical perspective. In this article, the basic design of one type of SPM, the atomic force microscope (AFM), is introduced followed by an examination of the different levels of resolution that may be exploited to obtain fundamental information on kink, step, and surface microtopography from mineral surfaces immersed in reactive solutions. The examples of these particular applications highlight the influence of solution chemistry on the rates and mechanisms of mineral growth and dissolution reactions that are readily followed with in-situ AFM instrumentation.

Higgins, Steven↗

Nanoscale Mapping of Hydrogen Distribution in Nuclear Structural Materials Using Cryogenic Transfer Atom Probe Tomography

Analyzing hydrogen distribution in nuclear structural materials at sub-nanometer scale spatial resolution has been challenging by electron microscopy. Furthermore, methods such as thermal desorption spectroscopy only provides a bulk estimate of hydrogen concentration with no nanoscale spatial resolution. In the last decade, cryogenic transfer atom probe tomography (APT) has been emerging as an invaluable characterization technique for analyzing the nanoscale distribution of hydrogen isotopes in materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Possibility of corrector plate tuning of x-ray focusing

Schemes for focusing a hard x-ray beam to a small spot are described. The theoretical minimum spot size, assuming perfect mirror shape, is shown to be 4 nm FWHM, independent of x-ray wavelength. This is less than the 10 nm previously said to be the minimum achievable diffraction-limited x-ray spot size. While providing the penetrating power only possible with x rays, this approaches the resolution needed to image individual atoms or atomic layers. However, the perfect mirror assumption is physically unrealistic. This paper discusses the compensation of mirror shape errors by a corrector plate and shows that the tolerances for corrector plate shape are far looser than are tolerances for mirror shape. The full eventual success of achieving theoretical minimum resolution will require mirror shape precision considerably better than has been achieved at this time, though far looser than would be required for simpleminded paraboloidal focusing. Two variants of the scheme, subject to the same mathematical treatment, are described. (i) The ''corrector plate'' name is copied from the similarly functioning element of the same name in a Schmidt camera. The focusing is achieved using glancing, yet coherent, reflection from a high-Z paraboloidal mirror. The strategy is to obtain dominant focusing from reflection and to compensate with weak refractive focusing. The reflective focusing is strong and achromatic but insufficiently accurate. The refractive focusing is weak and chromatic but highly accurate. The corrector plate improves resolution the way eyeglasses help a person to see. It can, for example, be ''fitted'' the same trial-and-error way an optometrist establishes a prescription for glasses. Dimensional tolerances for the compensator are far looser than would be needed for a mirror to achieve the same resolution. Unlike compound refractive lenses, attenuation will be small, at least for wavelengths longer than 1 A, because the compensation layer is thin. (ii) For this variant, the corrector plate is a washer-shaped refractive or Fresnel lens, and the mirror is (theoretically) a perfect cone. All focusing is provided by the lens. Even though the cone provides no focusing, it improves the resolution by increasing the numerical aperture of the device. Compared to a paraboloidal shape, it is assumed that the conical shape can be more accurately fabricated. Of the two variants, only the first variant is, in principle, capable of achieving the theoretical minimum resolution. Configurations are suggested, in both case (i) and case (ii), that use currently possible construction precisions to produce resolutions better than have been achieved to date. However, both results will remain well above the theoretical minimum until fabrication techniques have been developed that provide greater precision than is possible at this time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sub-wavelength imaging and field mapping via electromagnetically induced transparency and Autler-Townes splitting in Rydberg atoms

We present a technique for measuring radio-frequency (RF) electric field strengths with sub-wavelength resolution. We use Rydberg states of rubidium atoms to probe the RF field. The RF field causes an energy splitting of the Rydberg states via the Autler-Townes effect, and we detect the splitting via electromagnetically induced transparency (EIT). We use this technique to measure the electric field distribution inside a glass cylinder with applied RF fields at 17.04 GHz and 104.77 GHz. We achieve a spatial resolution of ≈100 μm, limited by the widths of the laser beams utilized for the EIT spectroscopy. We numerically simulate the fields in the glass cylinder and find good agreement with the measured fields. Our results suggest that this technique could be applied to image fields on a small spatial scale over a large range of frequencies, up into the sub-terahertz regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗