Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Ultrasonic angle beam standard reflector

A method that provides an impression profile in a reference standard material utilized in inspecting critically stressed components with pulsed ultrasound is described. A die stamp having an I letter is used to impress the surface of a reference material. The die stamp is placed against the surface and struck with an inertia imparting member to impress the I in the reference standard material. Upset may appear on the surface as a result of the impression and is removed to form a smooth surface. The stamping and upset removal is repeated until the entire surface area of a depth control platform on the die stamp uniformly contacts the material surface. The I impression profile in the reference standard material is utilized for reflecting pulsed ultrasonic beams for inspection purposes.

Berry, R. F., Jr.↗

Phonons with orbital angular momentum

Ion accoustic waves or phonon modes are studied with orbital angular momentum (OAM) in an unmagnetized collissionless uniform plasma, whose constituents are the Boltzmann electrons and inertial ions. For this purpose, we have employed the fluid equations to obtain a paraxial equation in terms of ion density perturbations and discussed its Gaussian beam and Laguerre-Gauss (LG) beam solutions. Furthermore, an approximate solution for the electrostatic potential problem is presented, allowing to express the components of the electric field in terms of LG potential perturbations. The energy flux due to phonons is also calculated and the corresponding OAM is derived. Numerically, it is shown that the parameters such as azimuthal angle, radial and angular mode numbers, and beam waist, strongly modify the profiles of the phonon LG potential. The present results should be helpful in understanding the phonon mode excitations produced by Brillouin backscattering of laser beams in a uniform plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-T-162: Comparison of Beam Data for Two Varian ProBeam Pencil Beam Scanning Proton Systems

Purpose: To compare the beam data for proton spot scanning beams for the first two Varian ProBeam sites in the US at the Maryland Proton Treatment Center (MPTC) and Scripps Proton Therapy Center (Scripps). To investigate how well beams can be matched between rooms. Method: Beam data were acquired with independent dosimetry systems and compared for two sites. Integrated depth dose curves (IDDs) were acquired with large volume PTW Bragg peak chambers in a 3D water tank for pencil beams at both sites. Spot profiles were acquired at different distances from the isocenter at a gantry angle of 0 degrees as well as function of gantry angle. Results: IDDs for the two Varian ProBeam proton sites are similar, except in the plateau region were the Scripps data is on average 4.5% higher relative to each other, but only 1.5% relative to the maximum at the Bragg Peak. This increase in the plateau region decrease as energy increase and for energies larger than 180 MeV there is no marked difference. Range in water coincide for all energies within 0.5mm. The sigma of the spot profiles in air are within 10% of each other at isocenter. This difference increase as the detector distance from the isocenter is increased. Conclusion: Beam data of the Varian ProBeam proton spot scanning beams for two sites are very well matched. Differences will not be clinically relevant.

60 APPLIED LIFE SCIENCES↗

Comparison of reflectivity and wind profiles measured on 46.8 MHz and 430 MHz at the Arecibo Observatory

Comparisons of troposphere and stratosphere radar experiments at ultrahigh frequency (UHF) and very high frequency (VHF) were done at the Arecibo Observatory in April 1980 with the 430 MHz and 46.8 MHz radar. The velocity profiles measured on both frequencies with the Doppler beam swinging mode were compared. In general, the velocity profiles were equivalent. The VHF profile, however, shows more fluctuations with height than the UHF profile, although the latter was recorded with 150 m resolution instead of 300 m resolution on VHF.

Rottger, J.↗

Integrated freeform optical couplers

Reflecting light beams off of microscale three-dimensional (3D) freeform surfaces can yield highly efficient coupling into and out of optical waveguides, optical fibers, and photonic chips. The structure of the 3D freeform reflective surface determines the shape of the reflected beam. This allows freeform reflectors to control the mode profile, rotation angle, and divergence angle of light beams. Control of beam shape enables mode matching between source output mode and target input mode, which results in low-loss optical coupling. An inventive freeform reflective surface can direct light beams in plane or out of plane via specular reflection or total internal reflection. A photonic integrated circuit with this type of freeform optical coupler can operate with a bandwidth range of at least 400 nm, potentially encompassing all visible or telecommunications wavelengths, and can be volume manufactured in photonic chips.

Yu, Shaoliang↗

Numerical analysis of the direct drive illumination uniformity for the Laser MegaJoule facility

The illumination uniformity provided during the initial imprinting phase of the laser foot pulse in a direct drive scenario at the Laser MegaJoule facility has been analyzed. This study analyzes the quality of the illumination of a spherical capsule and concerns the uniformity of the first shock generate in the absorber of an Inertial Confinement Fusion capsule. Four configurations making use of all or some of the 80 laser beams organized in the 20 quads of the cones at 49° and 131° with respect to the polar axis have been considered in order to assemble the foot pulse. Elliptical and circular super-gaussian laser intensity profiles taking into account beam-to-beam power imbalance (10%), pointing error (50 μm), and target positioning (20 μm) have been considered. It has been found that the use of the Polar Direct Drive technique can in some cases reduce the irradiation non-uniformity by a factor as high as 50%. In all cases, elliptical profile provides better results in comparison with the circular one and it is shown that the minimum of the non-uniformity is also a function of the capsule radius.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-190: Commissioning An Elekta VersaHD Linear Accelerator

Purpose: The purpose of this study is to report the dosimetric aspects of commissioning performed on an Elekta VersaHD linear accelerator with high dose rate flattening-filter-free (FFF) photon modes and electron modes. Methods: Acceptance and commissioning was performed on an Elekta VersaHD linac with 5 photon energies (6MV, 10MV, 18MV, 6FFF, 10FFF), 4 electron energies (6MeV, 9MeV, 12MeV, 15MeV) and 160 leaf (5mm wide) multi-leaf collimators (MLCs). Mechanical and dosimetric data was measured and evaluated. The measurements include percent depth doses (PDDs), inplane and crossplane profiles, head scatter factor (Sc), relative photon output factors (Scp), universal wedge transmission factor, MLC transmission factors, and electron cone factors. Results: Gantry, collimator, couch isocentricity measurements were within 1mm, 0.7mm and 0.7mm diameter respectively. The PDDs of 6FFF and 10FFF beams show deeper dmax and steeper fall-off with depth than the corresponding flattened beams. While flatness values of 6FFF and 10FFF normalized profiles were higher than the corresponding flattened beams, the symmetry values were almost identical. The crossplane penumbra values were higher than the inplane penumbra values for all the energies. The MLC transmission values were 0.5%, 0.6% and 0.6% for 6MV, 10MV, and 18MV photon beams. The electron PDDs, profiles and cone factors is validated by literature. Conclusion: The outcome of radiation treatment is directly related to the accuracy in the dose modeled in the treatment planning system which is based on the commissioned data. Commissioning data provided us a valuable insight into the dosimetric characteristics of the beam. This set of commissioning data can provide comparison data to others performing VersaHD commissioning thus improving patient safety.

60 APPLIED LIFE SCIENCES↗

Space-Charge and Other Effects in Fermilab Booster and IOTA Rings’ Ionization Profile Monitors

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. At low beam intensities, initial velocities of the secondaries to collect (ions or electrons) result in the IPM profile smearing. At high beam intensities, the space-charge forces make the measured IPM profiles significantly different from those of the beams. We analyze dynamics of the secondaries in IPMs, describe an effective algorithm to reconstruct the beam sizes from the measured IPM profiles and apply it to the Fermilab 8 GeV proton Booster and 70 MeV/c IOTA ring IPMs.

Shiltsev, Vladimir D.↗

Advancing the Frontiers of Deep Learning for Low-Dose 3D Cone-Beam CT Reconstruction

X-ray computed tomography (CT) is an important noninvasive medical imaging modality for studying the structural details of internal organs. Image reconstruction in CT is an inverse problem of recovering an object's internal structure from the absorption profile of X-ray beams (sinogram) measured using a detector. The classical variational approach for CT reconstruction minimizes an energy functional using an appropriate iterative algorithm. Motivated by the success of deep learning (DL), researchers have begun to leverage training data and enhanced computing capabilities in recent years to produce high-fidelity reconstructed images. Nonetheless, much of the academic research in DL algorithms for CT has focused primarily on the two-dimensional setting (with simplified forward operators and noise model) for proofs-of-concept, and a comprehensive benchmarking of various classical and data-driven CT reconstruction approaches has not beenundertaken. The key objective of our CT reconstruction grand challenge was to promote methodological advancements for both classical and DL-based approaches for clinical CT with a reasonably accurately simulated 3D CT forward operator and noise model. We have utilized the publicly available LIDC-IDRI dataset and simulated sinograms and FDK images corresponding to two dose levels (clinical- and low-dose, constituting two tracks of the challenge) starting from the normal-dose images as the ground truth. In this paper, we summarize the motivation, context, and results of our challenge, and highlight the future research directions in DL for clinical CT.

X-ray tomography↗

Optical cone beam tomography of Cherenkov-mediated signals for fast 3D dosimetry of x-ray photon beams in water

Purpose: To test the use of a three-dimensional (3D) optical cone beam computed tomography reconstruction algorithm, for estimation of the imparted 3D dose distribution from megavoltage photon beams in a water tank for quality assurance, by imaging the induced Cherenkov-excited fluorescence (CEF). Methods: An intensified charge-coupled device coupled to a standard nontelecentric camera lens was used to tomographically acquire two-dimensional (2D) projection images of CEF from a complex multileaf collimator (MLC) shaped 6 MV linear accelerator x-ray photon beam operating at a dose rate of 600 MU/min. The resulting projections were used to reconstruct the 3D CEF light distribution, a potential surrogate of imparted dose, using a Feldkamp–Davis–Kress cone beam back reconstruction algorithm. Finally, the reconstructed light distributions were compared to the expected dose values from one-dimensional diode scans, 2D film measurements, and the 3D distribution generated from the clinical Varian ECLIPSE treatment planning system using a gamma index analysis. A Monte Carlo derived correction was applied to the Cherenkov reconstructions to account for beam hardening artifacts. Results: 3D light volumes were successfully reconstructed over a 400 × 400 × 350 mm{sup 3} volume at a resolution of 1 mm. The Cherenkov reconstructions showed agreement with all comparative methods and were also able to recover both inter- and intra-MLC leaf leakage. Based upon a 3%/3 mm criterion, the experimental Cherenkov light measurements showed an 83%–99% pass fraction depending on the chosen threshold dose. Conclusions: The results from this study demonstrate the use of optical cone beam computed tomography using CEF for the profiling of the imparted dose distribution from large area megavoltage photon beams in water.

07 ISOTOPE AND RADIATION SOURCES↗

A comparison of methods for the measurement of the absorption coefficient in natural waters

In the spring of 1992 an optical closure experiment was conducted at Lake Pend Orielle, Idaho. A primary objective of the experiment was to compare techniques for the measurement of the spectral absorption coefficent and other inherent optical properties of natural waters. Daily averages of absorption coefficents measured using six methods are compared at wavelengths of 456, 488, and 532 nm. Overall agreement was within 40% at 456 nm and improved with increasing wavelength to 25% at 532 nm. These absorption measurements were distributed over the final 9 days of the experiement, when bio-optical conditions in Lake Pend Oreille (as indexed by the beam attenuation coefficent c(sub p)(660) and chlorophyll a fluorescence profiles) were representative of those observed throughout the experiment. However, profiles of stimulated chlorophyll a fluorescence and beam transmission showed that bio-optical properties in the lake varied strongly on all time and space scales. Therefore environmental variabilty contributed significantly to deviations between daily mean absorption coefficients measured using the different techniques.

Pegau, W. Scott↗

Measurement of Sub-Picosecond Electron Bunches via Electro-Optic Sampling of Coherent Transition Radiation

Future collider applications as well as present high-gradient laser plasma wakefield accelerators and free-electron lasers operating with picosecond bunch durations place a higher demand on the time resolution of bunch distribution diagnostics. This demand has led to significant advancements in the field of electro-optic sampling over the past ten years. These methods allow the probing of diagnostic light such as coherent transition radiation or the bunch wakefields with sub-picosecond time resolution. We present results on the single-shot electro-optic spectral decoding of coherent transition radiation from bunches generated at the Fermilab A0 photoinjector laboratory. A longitudinal double-pulse modulation of the electron beam is also realized by transverse beam masking followed by a transverse-to-longitudinal phase-space exchange beamline. Live profile tuning is demonstrated by upstream beam focusing in conjunction with downstream monitoring of single-shot electro-optic spectral decoding of the coherent transition radiation.

43 PARTICLE ACCELERATORS↗

SU-F-T-475: An Evaluation of the Overlap Between the Acceptance Testing and Commissioning Processes for Conventional Medical Linear Accelerators

Purpose: This work’s objective is to determine the overlap of processes, in terms of sub-processes and time, between acceptance testing and commissioning of a conventional medical linear accelerator and to evaluate the time saved by consolidating the two processes. Method: A process map for acceptance testing for medical linear accelerators was created from vendor documentation (Varian and Elekta). Using AAPM TG-106 and inhouse commissioning procedures, a process map was created for commissioning of said accelerators. The time to complete each sub-process in each process map was evaluated. Redundancies in the processes were found and the time spent on each were calculated. Results: Mechanical testing significantly overlaps between the two processes - redundant work here amounts to 9.5 hours. Many beam non-scanning dosimetry tests overlap resulting in another 6 hours of overlap. Beam scanning overlaps somewhat - acceptance tests include evaluating PDDs and multiple profiles but for only one field size while commissioning beam scanning includes multiple field sizes and depths of profiles. This overlap results in another 6 hours of rework. Absolute dosimetry, field outputs, and end to end tests are not done at all in acceptance testing. Finally, all imaging tests done in acceptance are repeated in commissioning, resulting in about 8 hours of rework. The total time overlap between the two processes is about 30 hours. Conclusion: The process mapping done in this study shows that there are no tests done in acceptance testing that are not also recommended to do for commissioning. This results in about 30 hours of redundant work when preparing a conventional linear accelerator for clinical use. Considering these findings in the context of the 5000 linacs in the United states, consolidating acceptance testing and commissioning would have allowed for the treatment of an additional 25000 patients using no additional resources.

60 APPLIED LIFE SCIENCES↗

Сomposition Depth Profiling of the GaAs Native Oxide Irradiated by an Ar{sup +} Ion Beam

The elemental and chemical compositions throughout the thickness of the GaAs native oxide layer slightly irradiated by Ar{sup +} ions have been studied by synchrotron-based photoelectron spectroscopy at different photon energies enabling variation of probing depth. The presence of only two phases was observed: of the gallium oxide Ga{sub 2}O{sub 3} and elementary arsenic As{sup o} generated due to complete decay of arsenic oxides under the ion irradiation. Depth composition profiles were determined nondestructively. Despite inhomogeneous depth distribution, these profiles demonstrated domination (90 at %) of the dielectric Ga{sub 2}O{sub 3} phase virtually throughout all the oxide thickness (~2 nm).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Destabilization of counter-propagating Alfvénic instabilities by tangential, co-current neutral beam injection

Injection of high-energy neutrals is a common tool to heat the plasma and drive current non-inductively in fusion devices. Once neutrals ionize, the resulting energetic particles can drive instabilities that are detrimental for the performance and the predictability of plasma discharges. A broad deposition profile of neutrals from neutral beam injection, e.g. by aiming the beam tangentially on the outboard midplane (i.e. off-axis), is often assumed to limit those undesired effects by reducing the radial gradient of the EP density, thus reducing the drive for instabilities. However, this paper presents new evidence that tangential neutral beam injection, including off-axis injection near the plasma mid-radius, can also lead to undesired effects such as the destabilization of Alfvénic instabilities. Time-dependent analysis with the TRANSP code indicates that instabilities are driven by a combination of radial and energy gradients in the distribution function of the energetic particles. Finally, the mechanisms for wave-particle interaction revealed by the energetic particle phase space resolved analysis are the basis to identify strategies to mitigate or suppress the observed instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intrinsic spatial chirp of subcycle terahertz pulsed beams

Here, we present an analysis of spatial chirp in subcycle pulsed beams corroborated by spatiotemporal electro-optic sampling measurements of terahertz radiation. Modeling the subcycle pulsed beam as a superposition of monochromatic Gaussian beams, free-space propagation is shown to directly lead to lateral spatial chirp with the spectrum on-axis substantially bluer than the overall energy spectrum. The two-transverse + one-temporal dimensional profile of terahertz subcycle pulsed beams from organic crystals DSTMS and OH1 are measured and compared with observed spatiospectral correlations consistent with the model.

43 PARTICLE ACCELERATORS↗