Search NASA⌕ Search

SEARCH · Search NASA

Results for “Battery Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Control Oriented Model of Cabin-HVAC System in a Long-Haul Trucks for Energy Management Applications

Super Truck II is a 48V mild hybrid class 8 truck with an all auxiliary loads powered purely by the battery pack. Electric Heating Ventilation and Air Conditioning (HVAC) load is the most prominent battery load during the hotel period, when the truck driver is resting inside the sleeper. For the PACCAR Super Truck II (ST-II) project a 48 V battery system provides the required power during the hotel period. A cabin-HVAC model estimates the electric load on the 48V battery system, allowing the control system to implement an efficient energy management strategy that avoids engine idling during the hotel period. The thermal model accounts for the sun load due to the time of day and the geographic location of the truck during the hotel period. The cabin-HVAC model has two parts. First, a grey box model with two heat exchangers (Condenser and Evaporator) working in unison with refrigerant mass flow rate as an input and HVAC load as an output. Second, a two-node cabin model formulated to estimate the cabin temperature as a function of the Global Horizontal Irradiance (GHI), HVAC load and ambient temperature. The models are calibrated using experimental cabin-HVAC system data as for long-haul class 8 truck (e.g. ST-II). Here, the model simulations show that the overall Root Mean Square Error (RMSE) value of 0.4°C between the experimental and simulated cabin temperature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analyzing and Minimizing Capacity Fade through Optimal Model-Based Control - Theory and Experimental Validation

In order to significantly expand the BEV market, and to increase the use of lithium-ion batteries in electric grids, there is a need to develop optimal charging strategies to utilize the batteries more efficiently and enable longer life. Advanced battery management systems that can calculate and implement such strategies in real time are expected to play a critical role for this purpose. This article investigates different approaches for determining model-based optimal charging profiles for batteries, and experimentally validates the gain obtained using such profiles. Optimal profiles that maximize the cycle life of the cells are implemented on 16 Ah NMC cells for 30 minutes of charge followed by 5C discharge, and the cycle life is compared to a standard 2C CC-CV charge and 5C discharge. An improvement of more than 100% in cycle life is observed experimentally, for our test conditions on this cell design. This study is the first to experimentally demonstrate that the improved extra knowledge obtained by sophisticated physics-based models results in significant improvements in battery performance when employed in a real time control algorithm.

25 ENERGY STORAGE↗

Validating Performance Models for Hybrid Power Plant Control Assessment

The need for simple, but accurate performance models of wind turbine generators (WTGs), photovoltaic (PV) plants, and battery energy storage systems (BESS) for various hybrid power plant (HPP) studies motivates the present work. Particularly, the development and verification stage of HPP controls requires reduced-order models to minimize the complexity and computation effort of simulation platforms. In this paper, such models are proposed, and the most essential parts of the models are validated through field measurements. The models target power system integration studies involving active and reactive power, as well as frequency and voltage regulation where detailed models, as proposed in the standards, can be cumbersome. Field measurements of two Vestas WTGs, one 1-MW PV plant, and one 1-MW/1-MWh BESS are used for model validation. The results show that the WTG and PV performance models correctly estimate the power generation variability according to fluctuations in wind speed and solar irradiance. The BESS performance model provides satisfactory results related to grid-forming control performance and estimation of state-of-charge. The presented validation work enables using the proposed performance models for power system studies and HPP control design in all model-based design stages, that is, preliminary analysis, design, verification, and validation with a high level of confidence.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of heating and cooling loads on battery energy storage system sizing in extreme cold climates

Efficient operation of battery energy storage systems requires that battery temperature remains within a specific range. Current techno-economic models neglect the parasitic loads heating and cooling operations have on these devices, assuming they operate at constant temperature. In this work, these effects are investigated considering the optimal sizing of battery energy storage systems when deployed in cold environments. Here, a peak shaving application is presented as a linear programming problem which is then formulated in the PYOMO optimization programming language. The building energy simulation software EnergyPlus is used to model the heating, ventilation, and air conditioning load of the battery energy storage system enclosure. Case studies are conducted for eight locations in the United States considering a nickel manganese cobalt oxide lithium ion battery type and whether the power conversion system is inside or outside the enclosure. The results show an increase of 42% to 300% in energy capacity size, 43% to 217% in power rating, and 43% to 296% increase in capital cost dependent on location. This analysis shows that the heating, ventilation, and air conditioning load can have a large impact on the optimal sizes and cost of a battery energy storage system and merit consideration in techno-economic studies.

25 ENERGY STORAGE↗

Methods for Representing Flexible, Energy-Constrained Technologies in Utility Planning Tools

Capacity expansion models are widely used by power system researchers, planners, and policy analysts to evaluate alternative power system investment scenarios. With the increasing deployment of wind and solar in the US, there has been much focus on improving the representations of variable generation (VG) technologies within capacity expansion models. Models that capture the variable net-load profiles and larger reserve requirements associated with high penetration VG systems represent an improvement to classic capacity expansion models, but fall short of capturing the complexities associated with storage technologies, such as battery energy storage (BES) and concentrating solar power with thermal energy storage (CSP with TES). While difficult to model in a capacity expansion setting, these technologies are potentially competitive sources of flexibility with the intriguing characteristics of being able to absorb VG that would otherwise be curtailed and directly contribute to renewable energy goals, respectively. In this paper we present methods for accurately representing these technologies in a large-scale capacity expansion model with high electrical and geospatial resolution. VG modeling techniques, including novel methods for capturing curtailment due to unit commitment and other hourly dispatch phenomena, are also reviewed. Modeling for a region in the southwestern United States demonstrates the economic relevance of being able to explicitly trade off the costs and capabilities of energy-constrained technologies, especially BES, against other resources in the near-term, in time to make plans for the coming decade

24 POWER TRANSMISSION AND DISTRIBUTION↗

Use-Phase Drives Lithium-Ion Battery Life Cycle Environmental Impacts When Used for Frequency Regulation

Battery storage systems are attractive alternatives to conventional generators for frequency regulation due to their fast response time, high cycle efficiency, flexible scale, and decreasing cost. However, their implementation does not consistently reduce environmental impacts. To assess these impacts, we employed a life cycle assessment (LCA) framework. Our framework couples cradle-to-gate and end-of-life LCA data on lithium-ion batteries with a unit commitment and dispatch model. The model is run on a 9-bus power system with energy storage used for frequency regulation. The addition of energy storage changes generator commitment and dispatch, causing changes in the quantities of each fuel type consumed. This results in increased environmental impacts in most scenarios. The impacts caused by the changes in the power system operation (i.e., use-phase impacts) outweigh upstream and end-of-life impacts in the majority of scenarios analyzed with the magnitude most influenced by electricity mix and fuel price. Of parameters specific to the battery, round trip efficiency has the greatest effect.

25 ENERGY STORAGE↗

Optimal management of electric hotel loads in mild hybrid heavy duty truck

Here, the problem of engine idling for heavy-duty trucks has been under study for decades with Auxiliary Power Units (APUs) and Truck Stop Electrification (TSE) as the most compelling solutions. With the electrification of trucks approaching feasibility in terms of cost-effective technology, hybridization offers another “degree of freedom” to tackle the problem. Here, this work aims at exploiting a battery pack of a 48 V mild-hybrid heavy-duty truck to store sufficient onboard energy for powering the auxiliary loads during the hoteling. This problem is not trivial, as the battery packs typically cannot recover the entire energy required through regeneration alone; hence an optimal energy management strategy needs to be employed to charge the battery through the engine during drive operation. This strategy optimizes powertrain performances among the four modes: (i) Engine of Coasting (EOC), (ii) Regeneration by braking, (iii) Regeneration by engine, and (iv) engine idling. This paper presents the development of a Dynamic Programming (DP) framework that employs a multi-objective cost function to minimize the fuel consumption and maximize the regeneration using the above-mentioned four modes. A typical heavy-duty truck drive cycle is used to represent the drive phase, with mandatory hoteling stops as per regulations. A comprehensive powertrain model is developed using validated components’ model. The DP employs two state variables: battery State-of-Charge (SOC) and engine mode, and three control inputs: (i) the engine ON–OFF state, (ii) clutch engagement state, and (iii) power request at the Electric Machine (EM) for calculating optimal SOC trajectory. The framework also tackles rapid engine ON–OFF scenarios to avoid the challenges associated with DP and the compromises in fuel cost with those approaches. Finally, the effectiveness of the proposed framework is tested for potential fuel savings on two different battery packs by performing the full cycle simulations. The results show 6.47% of fuel consumption reduction as compared to traditional APU-based heavy-duty truck.

33 ADVANCED PROPULSION SYSTEMS↗

Electric Vehicles as Flexibility Management Strategy for the Electricity System—A Comparison between Different Regions of Europe

This study considers whether electric vehicles (EVs) can be exploited as a flexibility management strategy to stimulate investments in and operation of renewable electricity under stringent CO 2 constraints in four regions with different conditions for renewable electricity (Sweden, Germany, the UK, and Spain). The study applies a cost-minimisation investment model and an electricity dispatch model of the European electricity system, assuming three types of charging strategies for EVs. The results show that vehicle-to-grid (V2G), i.e., the possibility to discharging the EV batteries back to grid, facilitates an increase in investments and generation from solar photovoltaics (PVs) compare to the scenario without EVs, in all regions except Sweden. Without the possibility to store electricity in EV batteries across different days, which is a technical limitation of this type of model, EVs increase the share of wind power by only a few percentage points in Sweden, even if Sweden is a region with good conditions for wind power. Full electrification of the road transport sector, including also dynamic power transfer for trucks and buses, would decrease the need for investments in peak power in all four regions by at least 50%, as compared to a scenario without EVs or with uncontrolled charging of EVs, provided that an optimal charging strategy and V2G are implemented for the passenger vehicles.

25 ENERGY STORAGE↗

Chance-Constrained Energy Management System for Power Grids With High Proliferation of Renewables and Electric Vehicles

This paper proposes a two-stage energy management system (EMS) for power grids with massive integration of electric vehicles (EVs) and renewable energy resources. The first stage economic dispatch determines the optimal operating points of charging stations and battery swapping stations (BSS) for EVs under plug-in and battery swapping modes, respectively. The proposed stochastic model predictive control (SMPC) problem in this stage is characterized through a chance-constrained optimization formulation that can effectively capture the system and the forecast uncertainties. A distributed algorithm, the alternating direction method of multipliers (ADMM), is applied to accelerate the optimization computation through parallel computing. The second stage is aimed in coordinating the EV charging mechanisms to continuously follow the first-stage solutions, i.e., the target operating points, and meeting the EV customers' charging demands captured via the Advanced Metering Infrastructure (AMI). In this work, the proposed solution offers a holistic control strategy for large-scale centralized power grids in which the aggregated individual parameters are predictable and the system dynamics do not vary sharply within a short time-interval.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Delivery drone route planning over a battery swapping network

Many enterprises invest on drone delivery research and development to drop off packages at consumers’ doorsteps in a matter of minutes. We study delivery drone route planning over a battery swapping network allowing farther reach by penetrating current battery capacity constraints. A mixed-integer nonlinear programming model is created to plan efficient drone routing over the swapping machines by minimizing the delivery lead time. We develop an exact solution method, evaluate its performance, and compare it with a straightforward nonlinear solver application. A case study highlights the applicability of the model. Data and source code to the solver are publicly shared.

drone battery swapping↗

Research Tool to Evaluate the Safety Response of Lithium Batteries to an Internal Short Circuit

Li-ion cells provide the highest specific energy and energy density rechargeable battery with the longest life. Many safety incidents that take place in the field originate due to an internal short that was not detectable or predictable at the point of manufacture. NREL's internal short circuit (ISC) device is capable of simulating shorts and produces consistent and reproducible results. The cell behaves normally until the ISC device is activated wherein a latent defect (i.e., built into the cell during manufacturing) gradually moves into position to create an internal short while the battery is in use, providing relevant data to verify abuse models. The ISC device is an effective tool for studying the safety features of parts of Li-ion batteries.

25 ENERGY STORAGE↗

Power allocation by load aggregator with heterogeneous loads using weighted projection

With the recently increasing adoption of transactive energy markets, the role of a load aggregator is becoming increasingly important. Among the many tasks of an aggregator, the task of managing the electricity consumption among a group of grid-interactive efficient buildings according to the demand on the grid is taken up. Specifically, here, the task of allocating a certain amount of power among the participating customers while respecting their preferences and comfort is considered. Modeling this as an aggregate flexibility, the virtual battery conditions that are employed to verify the feasibility of a candidate power profile are derived. A feasible power profile, when allocated, satisfies specified comfort bands. To determine the ideal power requirement of the loads, the model-free control method is employed. The feasible power profile is allocated by embedding the customers’ preferences through weights, posing the power constraint as a hyperplane, and employing a weighted projection from the ideal power requirements onto the constraint plane to solve the considered task. The proposed method is computationally efficient and scalable to any number of heterogeneous thermostatically controlled loads in buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Computational Analysis of Anode and Cathode Structuring Effects on Charge and Discharge in Graphite|LiNi 0.6 Mn 0.2 Co 0.2 O 2 Batteries

Structured electrodes (SEs) improve the rate capability of Lithium-ion batteries by engineering micrometer-scale electrolyte regions into the electrode, promoting rapid ionic transport. Prior research has focused on structuring one electrode (anode or cathode) with an analysis on either the charge or discharge performance. We present a holistic study using three-dimensional models to investigate the isolated effects of structuring either electrode and the combined effects of structuring both electrodes on the charge and discharge capacity of single-layer cells at 4 C and 6 C. Volumetric and gravimetric discharge energy density (Wh/L stack and Wh/kg stack ) and charge capacity (Ah/kg stack and Ah/L stack ) are evaluated for multi-layer pouch cell stacks. Pairing SE anodes with SE cathodes demonstrated improvements up to 15% in discharge Wh/kg stack and up to 33% in charge Ah/kg stack over a conventional cell; Energy required to charge per Ah/kg stack was improved by 13%–14%. SE cathodes paired with a conventional anode exhibited improvements of 0.3%–22% across all performance metrics evaluated. Conversely, pairing a SE anode with a conventional cathode demonstrated improved charge capacity up to 13% but showed a 2%–23% lower discharge energy density. The importance of aligning SEs in a cell from a performance and manufacturing perspective is also analyzed.

25 ENERGY STORAGE↗

Second Use of PEV Batteries: A Massive Storage Resource for Revolutionizing the Grid

The market penetration of plug-in electric vehicles (PEVs) and deployment of grid-connected energy storage systems are both presently impeded by the high cost of batteries. Battery second use (B2U) strategies-in which a single battery first serves an automotive application, then is redeployed into a secondary market-could help address both issues by reducing battery costs to the primary repurposed PEV batteries to serve grid applications for energy storage. The authors view this as of significant importance, as our expectation is that such batteries will be both cheap and plentiful. Understanding the dynamics of B2U will be important for customers and utilities in need of storage to understand when and where such batteries will be applicable. It will also be important for suppliers of other energy storage technologies, as repurposed PEV batteries could pose a significant threat to their business model.

25 ENERGY STORAGE↗

A look into the voltage plateau signal for detection and quantification of lithium plating in lithium-ion cells

Voltage plateau during relaxation or discharge after charging is a distinct signal associated with stripping of deposited Li metal and hence a feasible tool for online detection of Li plating in Li-ion batteries. In this report we present a physics-based model with incorporation of Li plating and stripping to gain a fundamental understanding of the voltage plateau behavior. Specifically, we focus on the internal cell characteristics when voltage plateau occurs and on key factors affecting the shape and duration of voltage plateau. Furthermore, the validity of using the duration of voltage plateau for estimating Li plating amount is assessed. It is found that the duration of voltage plateau depends on the rate of Li stripping, while the stripping rate is restricted by the capability of Li+ intercalation into graphite. Parameters like intercalation kinetics, solid-state diffusivity of graphite and cell temperature can substantially influence the voltage curves even with the same amount of Li plating. Further, we report an interesting phenomenon that during Li stripping one part of anode near the separator has net oxidation current (local stripping rate > intercalation rate), providing Li+ ions and electrons to the other part of anode near the foil which has net reduction current.

25 ENERGY STORAGE↗

Mesoscopic approach to modeling electric vehicle fleets based upon driving activity data to investigate recharge strategies’ impact on grid loads

This paper presents a mesoscopic model to populate a set of sub-fleets of battery electric vehicles (BEVs) that simulates how grid power demand changes with varied mixes of different charging strategies. The proposed model considers real driving activities of vehicles based on the National Household Travel Survey (NHTS) and various charging strategies while parked (at home and in other locations). To be easily scaled to any fleet size, a mesoscopic model is implemented, where BEVs with the same physical properties and driving schedules and clustered together into sub-fleets. The degree of granularity is explored for stable results. Monte Carlo simulations were run to demonstrate the potential of this model's use in grid loads under various charging strategies. Furthermore, an example cost function was optimized to demonstrate finding optimal allocations of charging strategies.

Electric Vehicles, Grid Integration, Monte Carlo S↗

EverBESS

SF-25-113 This software is a website for the EverBESS model. This model examines the cost and environmental impacts related to end-of-life management of battery energy storage systems. Users input their system's specifications and the model returns estimates for the costs of decommissioning, transporting, and recycling the system.

Elias, Jakob [Argonne National Laboratory (ANL), A↗

Evaluation of Rail Decarbonization Alternatives: Framework and Application

The Northwestern University Freight Rail Infrastructure & Energy Network Decarbonization (NUFRIEND) framework is a comprehensive industry-oriented tool for simulating the deployment of new energy technologies including biofuels, e-fuels, battery-electric, and hydrogen locomotives. By classifying fuel types into two categories based on deployment requirements, the associated optimal charging/fueling facility location and sizing problem are solved with a five-step framework. Life-cycle analysis (LCA) and techno-economic analysis (TEA) are used to estimate carbon reduction, capital investments, cost of carbon reduction, and operational impacts, enabling sensitivity analysis with operational and technological parameters. Here, the framework is illustrated on lower-carbon drop-in fuels as well as battery-electric technology deployments for the US Eastern and Western Class I railroad networks. Drop-in fuel deployments are modeled as admixtures with diesel in existing locomotives, while battery-electric deployments are shown for varying technology penetration levels and locomotive ranges. When mixed in a 50% ratio with diesel, results show biodiesel’s capacity to reduce emissions at 36% with a cost of $\$$ 0.13 per kilogram of CO 2 reduced, while e-fuels offer a potential reduction of 50% of emissions at a cost of $\$$ 0.22 per kilogram of CO 2 reduced. Battery-electric results for 50% deployment over all ton-miles highlight the value of future innovations in battery energy densities as scenarios assuming 800-mi range locomotives show an estimated emissions reduction of 46% with a cost of $\$$ 0.06 per kilogram of CO 2 reduced, compared with 16% emissions reduction at a cost of $\$$ 0.11 per kilogram of CO 2 reduced for 400-mi range locomotives. The NUFRIEND framework provides a systematic method for comparing different alternative energy technologies and identifying potential challenges and benefits in their future deployments.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗