Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALCULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Calculation of the axial charge in the {epsilon} and {epsilon}{sup '} regimes of heavy-baryon chiral perturbation theory

The axial charge g{sub A} is calculated in the {epsilon} regime of heavy-baryon chiral perturbation theory to order {epsilon}{sup 3}. To perform this calculation, we develop a technique to compute baryon properties in the {epsilon} regime of chiral perturbation theory. This technique includes contributions from pion zero momentum modes and can be used at arbitrary order, diagram by diagram, in the {epsilon} regime to calculate any matrix element. Also, a calculation of g{sub A} in the {epsilon}{sup '} regime to order {epsilon}{sup '3} is performed. A discussion of the domain of applicability for both the {epsilon} and {epsilon}{sup '} regimes is also included.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New ansatz for metric operator calculation in pseudo-Hermitian field theory

In this work, a new ansatz is introduced to make the calculations of the metric operator in pseudo-Hermitian field theory simpler. The idea is to assume that the metric operator is not only a functional of the field operator {phi} and its conjugate field {pi} but also on the field gradient {nabla}{phi}. The ansatz enables one to calculate the metric operator just once for all dimensions of the space-time. We calculated the metric operator of the i{phi}{sup 3} scalar field theory up to first order in the coupling. The higher orders can be conjectured from their corresponding operators in the quantum mechanical case available in the literature. We assert that the calculations existing in literature for the metric operator in field theory are cumbersome and are done case by case concerning the dimension of space-time in which the theory is investigated. In fact, with the aid of this work a rigorous study of a PT-symmetric Higgs mechanism can be reached.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-temperature ion-thermal behavior from average-atom calculations

Atom-in-jellium calculations of the Einstein frequency were used to calculate the mean displacement of an ion over a wide range of compression and temperature. Expressed as a fraction of the Wigner-Seitz radius, the displacement is a measure of the asymptotic freedom of the ion at high temperature, and thus of the change in heat capacity from six to three quadratic degrees of freedom per atom. A functional form for free energy was proposed based on the Maxwell-Boltzmann distribution as a correction to the Debye free energy, with a single free parameter representing the effective density of potential modes to be saturated. Finally, this parameter was investigated using molecular dynamics simulations, and found to be ~0.2 per atom. In this way, the ion-thermal contribution can be calculated for a wide-range equation of state (EOS) without requiring a large number of molecular dynamics simulations. Example calculations were performed for carbon, including the sensitivity of key EOS loci to ionic freedom.

74 ATOMIC AND MOLECULAR PHYSICS↗

First-principles calculation of the configurational energy density of states for a solid-state ion conductor with a variant of the Wang and Landau algorithm

In this work, a variant of the Wang and Landau algorithm for calculation of the configurational energy density of states is proposed. The algorithm was developed for the purpose of using first-principles simulations, such as density functional theory, to calculate the partition function of disordered sublattices in crystal materials. The expensive calculations of first-principles methods make a parallel algorithm necessary for a practical computation of the configurational energy density of states within a supercell approximation of a solid-state material. The algorithm developed in this work is tested with the two-dimensional (2d) Ising model to bench mark the algorithm and to help provide insight for implementation to a materials science application. Tests with the 2d Ising model revealed that the algorithm has good performance compared to the original Wang and Landau algorithm and the 1/$\textit{t}$ algorithm, in particular the short iteration performance. Further, a proof of convergence is presented within an adiabatic assumption, and the analysis is able to correctly predict the time dependence of the modification factor to the density of states. The algorithm was then applied to the lithium and lanthanum sublattice of the solid-state lithium ion conductor Li 0.5 La 0.5 TiO 3 . This was done to help understand the disordered nature of the lithium and lanthanum. The results find, overall, that the algorithm performs very well for the 2d Ising model and that the results for Li 0.5 La 0.5 TiO 3 are consistent with experiment while providing additional insight into the lithium and lanthanum ordering in the material. The primary result is that the lithium and lanthanum become more mixed between layers along the c axis for increasing temperature. In part, the simulation of the disordered Li 0.5 La 0.5 TiO 3 system serves as a benchmark for what size systems are currently and in the near future practical to calculate with density functional theory methods.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Static Self-Energy and Effective Mass of the Homogeneous Electron Gas from Quantum Monte Carlo Calculations

We discuss the methodology of quantum Monte Carlo calculations of the effective mass based on the static self-energy Σ(k,0). We then use variational Monte Carlo calculations of Σ(k,0) of the homogeneous electron gas at various densities to obtain results very close to perturbative G 0 W 0 calculations for values of the density parameter 1 ≤ r s ≤ 10. Here, the obtained values for the effective mass are close to diagrammatic Monte Carlo results and disagree with previous quantum Monte Carlo calculations based on a heuristic mapping of excitation energies to those of an ideal gas.

36 MATERIALS SCIENCE↗

All-electron density functional calculations for electron and nuclear spin interactions in molecules and solids

The interaction between electronic and nuclear spins in the presence of external magnetic fields can be described by a spin Hamiltonian, with parameters obtained from first principles, electronic structure calculations. We describe an approach to compute these parameters, applicable to both molecules and solids, which is based on density functional theory (DFT) and real-space, all-electron calculations using finite elements (FE). We report results for hyperfine tensors, zero field splitting tensors (spin-spin component), and nuclear quadrupole tensors of a series of molecules and of the nitrogen-vacancy center in diamond. We compare our results with calculations using Gaussian orbitals and plane-wave basis sets, and we discuss their numerical accuracy. Furthermore, we show that calculations based on FE can be systematically converged with respect to the basis set, thus allowing one to establish reference values for the spin Hamiltonian parameters, at a given level of DFT.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advanced calculations of X-ray spectroscopies with FEFF10 and Corvus

The real-space Green's function code FEFF has been extensively developed and used for calculations of X-ray and related spectra, including X-ray absorption (XAS), X-ray emission (XES), inelastic X-ray scattering, and electron energy-loss spectra. The code is particularly useful for the analysis and interpretation of the XAS fine-structure (EXAFS) and the near-edge structure (XANES) in materials throughout the periodic table. Nevertheless, many applications, such as non-equilibrium systems, and the analysis of ultra-fast pump–probe experiments, require extensions of the code including finite-temperature and auxiliary calculations of structure and vibrational properties. To enable these extensions, we have developed in tandem a new version FEFF10 and new FEFF -based workflows for the Corvus workflow manager, which allow users to easily augment the capabilities of FEFF10 via auxiliary codes. This coupling facilitates simplified input and automated calculations of spectra based on advanced theoretical techniques. The approach is illustrated with examples of high-temperature behavior, vibrational properties, many-body excitations in XAS, super-heavy materials, and fits of calculated spectra to experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Delayed Gamma Measurements in Different Nuclear Research Reactors Bringing Out the Importance of the Delayed Contribution in Gamma Flux Calculations

Neutron and gamma flux levels are key parameters in nuclear research reactors. In Material Testing Reactors, such as the future Jules Horowitz Reactor, under construction at the French Alternative Energies and Atomic Energy Commission (CEA Cadarache, France), the expected gamma flux levels are very high (nuclear heating is of the order of 20 W/g at 100 MWth). As gamma rays deposit their energy in the reactor structures and structural materials it is important to take them into account when designing irradiation devices. There are only a few sensors which allow measurements of the nuclear heating ; a recent development at the CEA Cadarache allows measurements of the gamma flux using a miniature ionization chamber (MIC). The measured MIC response is often compared with calculation using modern Monte Carlo (MC) neutron and photon transport codes, such as TRIPOLI-4 and MCNP6. In these calculations only the production of prompt gamma rays in the reactor is usually modelled thus neglecting the delayed gamma rays. Hence calculations and measurements are usually in better accordance for the neutron flux than for the gamma flux. In this paper we study the contribution of delayed gamma rays to the total MIC signal in order to estimate the systematic error in gamma flux MC calculations. In order to experimentally determine the delayed gamma flux contributions to the MIC response, we performed gamma flux measurements with CEA developed MIC at three different research reactors: the OSIRIS reactor (MTR - 70 MWth at CEA Saclay, France), the TRIGA MARK II reactor (TRIGA - 250 kWth at the Jozef Stefan Institute, Slovenia) and the MARIA reactor (MTR - 30 MWth at the National Center for Nuclear Research, Poland). In order to experimentally assess the delayed gamma flux contribution to the total gamma flux, several reactor shut down (scram) experiments were performed specifically for the purpose of the measurements. Results show that on average about 30 % of the MIC signal is due to the delayed gamma rays. In this paper we describe experiments in each of the three reactors and how we estimate delayed gamma rays with MIC measurements. The results and perspectives are discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Collection: TD-DFT and EOM-CCSD Calculations for the GDB-9-Ex Dataset

We present two datasets that contain quantum chemical electronic structure calculations for organic molecules from the GDB-9-Ex dataset. The “GDB-9-Ex_TD-DFT-PBE0” dataset contains calculations performed using the time-dependent density functional theory (TD-DFT) first principles method, and the “GDB-9-Ex_EOMCCSD” dataset contains calculations performed using the equation-of-motion coupled cluster (EOM-CCSD) method. Both types of calculations were performed using the ORCA software and provided ultraviolet-visible spectra with a high level of accuracy.

Mehta, Kshitij [Oak Ridge National Laboratory (ORN↗

Scaling Ensembles of Data-Intensive Quantum Chemical Calculations for Millions of Molecules

Deep learning models are efficient computational tools that can accelerate the inverse design of molecules with desired functional properties by generating predictions at a fraction of the time required by traditional quantum chemical approaches. To ensure that a model maintains accuracy and transferability across broad regions of the chemical space explored during the inverse design, it must be trained on massively large volumes of simulation data. This requires running large-scale ensemble quantum chemical calculations on high-performance computing (HPC) systems for data collection. However, the efficient execution of such large ensemble calculations and the management of large volumes of output data require tools that can judiciously utilize computational resources and manage metadata overhead on the file system. Therefore, we present a high-performance, scalable, ensemble management framework for performing data-intensive quantum chemical electronic structure calculations for organic molecules. This framework provides abstractions to plug different ab initio, first principles, and first principles-based semi-empirical methods and executes them efficiently at large scale on HPC systems. It dynamically distributes tasks to resources and uses tiered storage for managing large collections of files. We employed this framework to process over ten million organic molecules and generate open-source datasets that provide UV-vis absorption spectra by running time-dependent density-functional tight-binding calculations. It is the largest database containing molecular optical spectra that were simulated with quantum chemical methods in a consistent manner.

Mehta, Kshitij↗

Memory-Aware External Facelist Calculation: A Data-Parallel Atomic Hash Counting Approach

Unstructured volumetric meshes serve as fundamental data representations in various scientific simulations and analyses. They play a crucial role in representing complex computational domains and are essential for important numerical techniques, such as finite element analysis. Whenever such a mesh is read from a file, streamed in-situ, or generated by algorithms, scientific visualization libraries rely on calculating the external surface of a geometry, named “external facelist”, to produce a polygonal mesh for rendering. Consequently, external facelist calculation has become one of the most widely used algorithms in the scientific visualization domain, necessitating optimal performance. In this paper, we explore relevant work on external facelist calculation algorithms in two common visualization libraries, VTK and Viskores, assess their performance and memory constraints, and introduce a novel memory-aware external facelist calculation algorithm employing an atomic hash counting approach. This algorithm fully leverages Viskores' data-parallel primitive operations, facilitating its execution across diverse many-core architectures. Our algorithm features the lowest memory footprint on the GPU and the second-lowest on the CPU among all evaluated methods, and it also delivers the fastest performance on both CPU and GPU. It has been made available under an open-source license in the VTK and Viskores visualization systems.

Tsalikis, Spiros [Kitware] (ORCID:0000000151137195↗

Calibration of megavoltage cone-beam CT for radiotherapy dose calculations: Correction of cupping artifacts and conversion of CT numbers to electron density

Megavoltage cone-beam CT (MV CBCT) is used for three-dimensional imaging of the patient anatomy on the treatment table prior to or just after radiotherapy treatment. To use MV CBCT images for radiotherapy dose calculation purposes, reliable electron density (ED) distributions are needed. Patient scatter, beam hardening and softening effects result in cupping artifacts in MV CBCT images and distort the CT number to ED conversion. A method based on transmission images is presented to correct for these effects without using prior knowledge of the object's geometry. The scatter distribution originating from the patient is calculated with pencil beam scatter kernels that are fitted based on transmission measurements. The radiological thickness is extracted from the scatter subtracted transmission images and is then converted to the primary transmission used in the cone-beam reconstruction. These corrections are performed in an iterative manner, without using prior knowledge regarding the geometry and composition of the object. The method was tested using various homogeneous and inhomogeneous phantoms with varying shapes and compositions, including a phantom with different electron density inserts, phantoms with large density variations, and an anthropomorphic head phantom. For all phantoms, the cupping artifact was substantially removed from the images and a linear relation between the CT number and electron density was found. After correction the deviations in reconstructed ED from the true values were reduced from up to 0.30 ED units to 0.03 for the majority of the phantoms; the residual difference is equal to the amount of noise in the images. The ED distributions were evaluated in terms of absolute dose calculation accuracy for homogeneous cylinders of different size; errors decreased from 7% to below 1% in the center of the objects for the uncorrected and corrected images, respectively, and maximum differences were reduced from 17% to 2%, respectively. The presented method corrects the MV CBCT images for cupping artifacts and extracts reliable ED information of objects with varying geometries and composition, making these corrected MV CBCT images suitable for accurate dose calculation purposes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficiency improvements for ion chamber calculations in high energy photon beams

This article presents the implementation of several variance reduction techniques that dramatically improve the simulation efficiency of ion chamber dose and perturbation factor calculations. The cavity user code for the EGSnrc Monte Carlo code system is extended by photon cross-section enhancement (XCSE), an intermediate phase-space storage (IPSS) technique, and a correlated sampling (CS) scheme. XCSE increases the density of photon interaction sites inside and in the vicinity of the chamber and results - in combination with a Russian Roulette game for electrons that cannot reach the cavity volume - in an increased efficiency of up to a factor of 350 for calculating dose in a Farmer type chamber placed at 10 cm depth in a water phantom. In combination with the IPSS and CS techniques, the efficiency for the calculation of the central electrode perturbation factor P{sub cel} can be increased by up to three orders of magnitude for a single chamber location and by nearly four orders of magnitude when considering the P{sub cel} variation with depth or with distance from the central axis in a large field photon beam. The intermediate storage of the phase-space properties of particles entering a volume that contains many possible chamber locations leads to efficiency improvements by a factor larger than 500 when computing a profile of chamber doses in the field of a linear accelerator photon beam. All techniques are combined in a new EGSnrc user code egs{sub c}hamber. Optimum settings for the variance reduction parameters are investigated and are reported for a Farmer type ion chamber. A few example calculations illustrating the capabilities of the egs{sub c}hamber code are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calculation of the replacement correction factors for ion chambers in megavoltage beams by Monte Carlo simulation

This article describes four methods of calculating the replacement correction factor, P{sub repl} (or the product p{sub cav}p{sub dis} in the IAEA's notation), for a plane-parallel chamber in both electron and photon beams, and for a Farmer chamber in photon beams, by using the EGSnrc Monte Carlo code. The accuracy of underlying assumptions and relative merits of each technique are assessed. With careful selection of parameters it appears that all four methods give reasonable answers although the direct methods are more intellectually satisfying and more accurate in some cases. The direct methods are shown to have an accuracy of 0.1% when appropriate calculation parameters are selected. The depth dependence of P{sub repl} for the NACP02 plane-parallel chamber has been calculated in both 6 and 18 MeV electron beams. At the reference depth (0.6R{sub 50}-0.1 cm) P{sub repl} is 0.9964 for the 6 MeV beam and 1.0005 for the 18 MeV beam for this well-guarded chamber; at the depth of maximum dose for the 18 MeV beam, P{sub repl} is 1.0010. P{sub repl} is also calculated for the NACP02 chamber and a Farmer chamber (diameter 6 mm) at a depth of 5 cm in a {sup 60}Co photon beam, giving values of 1.0063 and 0.9964, respectively. For the Farmer chamber, P{sub repl} is about half a percent higher than the value (0.992) recommended by the AAPM dosimetry protocol. It is found that the dosimetry protocols may have adopted an incorrect value of P{sub repl} for cylindrical chambers in photon beams. The nonunity values of P{sub repl} for plane-parallel chambers in lower energy electron beams imply a variety of values used in dosimetry protocols must be reassessed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimization of deterministic transport parameters for the calculation of the dose distribution around a high dose-rate {sup 192}Ir brachytherapy source

The goal of this work was to calculate the dose distribution around a high dose-rate {sup 192}Ir brachytherapy source using a multi-group discrete ordinates code and then to compare the results with a Monte Carlo calculated dose distribution. The unstructured tetrahedral mesh discrete ordinates code Attila version 6.1.1 was used to calculate the photon kerma rate distribution in water around the Nucletron microSelectron mHDRv2 source. MCNPX 2.5.c was used to compute the Monte Carlo water photon kerma rate distribution. Two hundred million histories were simulated, resulting in standard errors of the mean of less than 3% overall. The number of energy groups, S{sub n} (angular order), P{sub n} (scattering order), and mesh elements were varied in addition to the method of analytic ray tracing to assess their effects on the deterministic solution. Water photon kerma rate matrices were exported from both codes into an in-house data analysis software. This software quantified the percent dose difference distribution, the number of points within {+-}3% and {+-}5%, and the mean percent difference between the two codes. The data demonstrated that a 5 energy-group cross-section set calculated results to within 0.5% of a 15 group cross-section set. S{sub 12} was sufficient to resolve the solution in angle. P{sub 2} expansion of the scattering cross-section was necessary to compute accurate distributions. A computational mesh with 55 064 tetrahedral elements in a 30 cm diameter phantom resolved the solution spatially. An efficiency factor of 110 with the above parameters was realized in comparison to MC methods. The Attila code provided an accurate and efficient solution of the Boltzmann transport equation for the mHDRv2 source.

61 RADIATION PROTECTION AND DOSIMETRY↗

EGSnrc Monte Carlo calculated dosimetry parameters for {sup 192}Ir and {sup 169}Yb brachytherapy sources

This study presents the results of EGSnrc Monte Carlo calculations of the dose distribution surrounding a high dose rate {sup 169}Yb brachytherapy source and 14 high dose rate and pulsed dose rate {sup 192}Ir brachytherapy sources. Energy-weighted spectra of emitted photons, a full set of TG-43 dosimetry parameters, along-away dose tables, and a description of the materials and geometry used for each source are provided. In addition to this, separate tallies are made of the dose contributed from primary, single-scattered, and multiply-scattered photons. Separation of dose in this manner allows one to use convolution/superposition methods to calculate the dose surrounding a brachytherapy source accounting for a non-homogeneous medium. The effect of phantom size on TG-43 dosimetry parameters and scattered dose is also investigated for the {sup 192}Ir microSelectron v2 HDR source. This paper describes the calculation methods and presents the dose rate constants calculated for each source with the full set of dosimetry data being available online at the Carleton Laboratory for Radiotherapy Physics brachytherapy database (http://www.physics.carleton.ca/clrp/seed lowbar database/).

61 RADIATION PROTECTION AND DOSIMETRY↗

Accuracy of Spencer-Attix cavity theory and calculations of fluence correction factors for the air kerma formalism

EGSnrc calculations of ion chamber response and Spencer-Attix (SA) restricted stopping-power ratios are used to test the assumptions of the SA cavity theory and to assess the accuracy of this theory as it applies to the air kerma formalism for {sup 60}Co beams. Consistent with previous reports, the EGSnrc calculations show that the SA cavity theory, as it is normally applied, requires a correction for the perturbation of the charged particle fluence (K{sub fl}) by the presence of the cavity. The need for K{sub fl} corrections arises from the fact that the standard prescription for choosing the low-energy threshold {Delta} in the SA restricted stopping-power ratio consistently underestimates the values of {Delta} needed if no perturbation to the fluence is assumed. The use of fluence corrections can be avoided by appropriately choosing {Delta}, but it is not clear how {Delta} can be calculated from first principles. Values of {Delta} required to avoid K{sub fl} corrections were found to be consistently higher than {Delta} values obtained using the conventional approach and are also observed to be dependent on the composition of the wall in addition to the cavity size. Values of K{sub fl} have been calculated for many of the graphite-walled ion chambers used by the national metrology institutes around the world and found to be within 0.04% of unity in all cases, with an uncertainty of about 0.02%.

61 RADIATION PROTECTION AND DOSIMETRY↗

The effects of dose calculation resolution on dose accuracy for radiation therapy treatments of the lung. Part II. A comparison of dose distributions from an explicit lung model to dose distributions derived from a CT representation

Purpose: Due to limitations in computer memory and computation time, typical radiation therapy treatments are calculated with a voxel dimension on the order of several millimeters. The anatomy below this practical resolution is approximated as a homogeneous region uniform in atomic composition and density. The purpose of this article is to examine whether the exclusion of anatomic structure below the practical dose calculation resolution produces deviations in the resulting dose distributions. Methods: EGSnrc calculated dose distributions from the BRANCH lung model of Part I are compared and contrasted to dose distributions from a CT representation of the same BRANCH model for three different phases of the respiration cycle. Results: The exclusion of branching structures below a CT resolution of 1x1x2 mm{sup 3} resulted in a deviation in dose. The deviation in dose was as high as 14% but was localized around the branching structures. There was no significant variation in the dose deviation as a function of either field size or lung density. Conclusions: The exclusion of explicit branching structures of the lung in a CT representation creates localized deviations in dose. To ensure accurate dose calculations, CT resolution must be increased.

62 RADIOLOGY AND NUCLEAR MEDICINE↗