Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMFORT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Co-Simulation of Electric Power Distribution Systems and Buildings including Ultra-Fast HVAC Models and Optimal DER Control

Smart homes and virtual power plant (VPP) controls are growing fields of research with potential for improved electric power grid operation. A novel testbed for the co-simulation of electric power distribution systems and distributed energy resources (DERs) is employed to evaluate VPP scenarios and propose an optimization procedure. DERs of specific interest include behind-the-meter (BTM) solar photovoltaic (PV) systems as well as heating, ventilation, and air-conditioning (HVAC) systems. The simulation of HVAC systems is enabled by a machine learning procedure that produces ultra-fast models for electric power and indoor temperature of associated buildings that are up to 133 times faster than typical white-box implementations. Hundreds of these models, each with different properties, are randomly populated into a modified IEEE 123-bus test system to represent a typical U.S. community. Advanced VPP controls are developed based on the Consumer Technology Association (CTA) 2045 standard to leverage HVAC systems as generalized energy storage (GES) such that BTM solar PV is better utilized locally and occurrences of distribution system power peaks are reduced, while also maintaining occupant thermal comfort. An optimization is performed to determine the best control settings for targeted peak power and total daily energy increase minimization with example peak load reductions of 25+%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Influence of Demographic Variables on the Pooled Rideshare Acceptance Model Multigroup Analyses (PRAMMA)

Building on our prior research with a national survey sample of 5385 US participants, the Pooled Rideshare Acceptance Model (PRAM) was built upon two factor analyses. This exploratory study extends the PRAM framework using the Pooled Rideshare Acceptance Model Multigroup Analyses (PRAMMA) to examine how 16 demographic variables influence and interact with the acceptance of Pooled Rideshare (PR), filling a gap in understanding user segmentation and personalization. Using a national sample of 5385 US participants, this methodological approach allowed for the evaluation of how PRAM variables such as safety, privacy, service experience, and environmental impact vary across diverse groups, including gender, generation, driver’s license, rideshare experience, education level, employment status, household size, number of children, income, vehicle ownership, and typical commuting practices. Factors such as convenience, comfort, and passenger safety did not show significant differences across the moderators, suggesting their universal importance across all demographics. Furthermore, geographical differences did not significantly impact the relationships within the model, suggesting consistent relationships across different regions. The findings highlight the need to move beyond a “one size fits all” approach, demonstrating that tailored strategies may be crucial for enhancing the adoption and satisfaction of PR services among various demographic groups. The analyses provide valuable insight for policymakers and rideshare companies looking to optimize their services and increase user engagement in PR.

moderator↗

Evolution of cool-roof standards in the United States

Roofs that have high solar reflectance and high thermal emittance stay cool in the sun. A roof with lower thermal emittance but exceptionally high solar reflectance can also stay cool in the sun. Substituting a cool roof for a noncool roof decreases cooling-electricity use, cooling-power demand, and cooling-equipment capacity requirements, while slightly increasing heating-energy consumption. Cool roofs can also lower citywide ambient air temperature in summer, slowing ozone formation and increasing human comfort. Provisions for cool roofs in energy-efficiency standards can promote the building- and climate-appropriate use of cool roofing technologies. Cool-roof requirements are designed to reduce building energy use, while energy-neutral cool-roof credits permit the use of less energy-efficient components (e.g., larger windows) in a building that has energy-saving cool roofs. Both types of measures can reduce the life-cycle cost of a building (initial cost plus lifetime energy cost). Since 1999, several widely used building energy-efficiency standards, including ASHRAE 90.1, ASHRAE 90.2, the International Energy Conservation Code, and California's Title 24 have adopted cool-roof credits or requirements. This paper reviews the technical development of cool-roof provisions in the ASHRAE 90.1, ASHRAE 90.2, and California Title 24 standards, and discusses the treatment of cool roofs in other standards and energy-efficiency programs. The techniques used to develop the ASHRAE and Title 24 cool-roof provisions can be used as models to address cool roofs in building energy-efficiency standards worldwide.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tight Constraint on Photon Mass from Pulsar Spindown

Pulsars are magnetized rotating compact objects. They spin down due to magnetic dipole radiation and wind emission. If a photon has nonzero mass, the spin-down rate will be lower than in the zero-mass case. We show that an upper limit of the photon mass, i.e., m{sub γ}≲h/Pc{sup 2}, may be placed if a pulsar with period P is observed to spin down. Recently, a white dwarf (WD)–M dwarf binary, AR Scorpii, was discovered to emit pulsed broadband emission. The spin-down luminosity of the WD can comfortably power non-thermal radiation from the system. Applying our results to the WD pulsar with P = 117 s, we obtain a stringent upper limit of the photon mass between m{sub γ}<6.3×10{sup −50} g, assuming a vacuum dipole spindown, and m{sub γ}<9.6×10{sup −50} g, assuming spindown due to a fully developed pulsar wind.

79 ASTRONOMY AND ASTROPHYSICS↗

Trapping of noble gases by radiative association with H{sub 3}{sup +} in the protosolar nebula

The heavy noble gas deficiencies observed in Titan’s atmosphere and in comets have been proposed to be related to a sequestration process by H{sub 3}{sup +} in the gas phase at the early protosolar nebula. Chemical thermodynamics and astrophysics modeling are favorable to this hypothesis, as presented in preceding papers. However, there is a point still to be raised, i.e., that no dynamical study of the efficiency of the collisional processes had been performed so far. Here, we show that, apart from the expected exception of Ne, the rate constants obtained, i.e., 0.7 × 10{sup −18}, 0.5 × 10{sup −16}, and 10{sup −16} (cm{sup 3} s{sup −1}) for Ar, Kr, and Xe, respectively, are reasonably high for such processes, particularly in the case of Kr and Xe. The temperature dependence is also considered, showing a similar behavior for all noble gases with a peak efficiency in the range 50–60 K. Globally, we can conclude that the scenario of sequestration by H{sub 3}{sup +} is definitively comforted by the results of our quantum dynamical treatment. This process may also be responsible of the Ar impoverishment just measured in comet 67P/Churyumov–Gerasimenko by the ROSINA mass spectrometer on board the Rosetta spacecraft.

79 ASTRONOMY AND ASTROPHYSICS↗

A 78 day X-ray period detected from NGC 5907 ULX1 by Swift

We report the detection of a 78.1 ± 0.5 day period in the X-ray light curve of the extreme ultraluminous X-ray source NGC 5907 ULX1 (L{sub X,peak}∼5×10{sup 40} erg s{sup −1}), discovered during an extensive monitoring program with Swift. These periodic variations are strong, with the observed flux changing by a factor of ∼3–4 between the peaks and the troughs of the cycle; our simulations suggest that the observed periodicity is detected comfortably in excess of 3σ significance. We discuss possible origins for this X-ray period, but conclude that at the current time we cannot robustly distinguish between orbital and super-orbital variations.

79 ASTRONOMY AND ASTROPHYSICS↗

CoolCalc: A Long-Haul Truck Thermal Load Estimation Tool

In the United States, intercity long-haul trucks idle approximately 1,800 hrs annually for sleeper cab hotel loads, consuming 838 million gallons of diesel fuel per year. The objective of the CoolCab project is to work closely with industry to design efficient thermal management systems for long-haul trucks that keep the cab comfortable with minimized engine idling. Truck engine idling isprimarily done to heat or cool the cab/sleeper, keep the fuel warm in cold weather, and keep the engine warm for cold temperature startup. Reducing the thermal load on the cab/sleeper will decrease air conditioning system requirements, improve efficiency, and help reduce fuel use. CoolCalc is an easy-to-use, simplified, physics-based HVAC load estimation tool that requires no meshing, hasflexible geometry, excludes unnecessary detail, and is less time-intensive than more detailed computer-aided engineering modeling approaches. It is intended for rapid trade-off studies, technology impact estimation, and preliminary HVAC sizing design and to complement more detailed and expensive CAE tools by exploring and identifying regions of interest in the design space. This paper describesthe CoolCalc tool, provides outdoor long-haul truck thermal testing results, shows validation using these test results, and discusses future applications of the tool.

30 DIRECT ENERGY CONVERSION↗

Application of Sleeper Cab Thermal Management Technologies to Reduce Idle Climate Control Loads in Long-Haul Trucks

Each intercity long-haul truck in the U.S. idles approximately 1,800 hrs per year, primarily for sleeper cab hotel loads. Including workday idling, over 2 billion gallons of fuel are used annually for truck idling. NREL's CoolCab project works closely with industry to design efficient thermal management systems for long-haul trucks that keep the cab comfortable with minimized engine idling andfuel use. The impact of thermal load reduction technologies on idle reduction systems were characterized by conducting thermal soak tests, overall heat transfer tests, and 10-hour rest period A/C tests. Technologies evaluated include advanced insulation packages, a solar reflective film applied to the vehicle's opaque exterior surfaces, a truck featuring both film and insulation, and abattery-powered A/C system. Opportunities were identified to reduce heating and cooling loads for long-haul truck idling by 36% and 34%, respectively, which yielded a 23% reduction in battery pack capacity of the idle-reduction system. Data were also collected for development and validation of a CoolCalc HVAC truck cab model. CoolCalc is an easy-to-use, simplified, physics-based HVAC loadestimation tool that requires no meshing, has flexible geometry, excludes unnecessary detail, and is less time-intensive than more detailed computer-aided engineering modeling approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Paint Color on Rest Period Climate Control Loads in Long-Haul Trucks: Preprint

Cab climate conditioning is one of the primary reasons for operating the main engine in a long-haul truck during driver rest periods. In the United States, sleeper cab trucks use approximately 667 million gallons of fuel annually for rest period idling. The U.S. Department of Energy's National Renewable Energy Laboratory's (NREL) CoolCab Project works closely with industry to design efficient thermal management systems for long-haul trucks that minimize engine idling and fuel use while maintaining occupant comfort. Heat transfer to the vehicle interior from opaque exterior surfaces is one of the major heat pathways that contribute to air conditioning loads during long-haul truck daytime rest period idling. To quantify the impact of paint color and the opportunity for advanced paints, NREL collaborated with Volvo Group North America, PPG Industries, and Dometic Environmental Corporation. Initial screening simulations using CoolCalc, NREL's rapid HVAC load estimation tool, showed promising air-conditioning load reductions due to paint color selection. Tests conducted at NREL's Vehicle Testing and Integration Facility using long-haul truck cab sections, 'test bucks,' showed a 31.1% of maximum possible reduction in rise over ambient temperature and a 20.8% reduction in daily electric air conditioning energy use by switching from black to white paint. Additionally, changing from blue to an advanced color-matched solar reflective blue paint resulted in a 7.3% reduction in daily electric air conditioning energy use for weather conditions tested in Colorado. National-level modeling results using weather data from major U.S. cities indicated that the increase in heating loads due to lighter paint colors is much smaller than the reduction in cooling loads.

30 DIRECT ENERGY CONVERSION↗

Sleeper Cab Climate Control Load Reduction for Long-Haul Truck Rest Period Idling

Annual fuel use for long-haul truck rest period idling is estimated at 667 million gallons in the United States. The U.S. Department of Energy’s National Renewable Energy Laboratory’s CoolCab project aims to reduce heating, ventilating, and air conditioning (HVAC) loads and resulting fuel use from rest period idling by working closely with industry to design efficient long-haul truck climate control systems while maintaining occupant comfort. Enhancing the thermal performance of cab/sleepers will enable smaller, lighter, and more cost-effective idle reduction solutions. In order for candidate idle reduction technologies to be implemented at the original equipment manufacturer and fleet level, their effectiveness must be quantified. To address this need, a number of promising candidate technologies were evaluated through experimentation and modeling to determine their effectiveness in reducing rest period HVAC loads. For this study, load reduction strategies were grouped into the focus areas of solar envelope, occupant environment, and conductive pathways. The technologies selected for a complete-cab package of technologies were “ultra-white” paint, advanced insulation, and advanced curtains. To measure the impact of these technologies, a nationally-averaged solar-weighted reflectivity long-haul truck paint color was determined and applied to the baseline test vehicle. Using the complete-cab package of technologies, electrical energy consumption for long-haul truck daytime rest period air conditioning was reduced by at least 35% for summer weather conditions in Colorado. The National Renewable Energy Laboratory's CoolCalc model was then used to extrapolate the performance of the thermal load reduction technologies nationally for 161 major U.S. cities using typical weather conditions for each location over an entire year.

33 ADVANCED PROPULSION SYSTEMS↗

Integration and Validation of a Thermal Energy Storage System for Electric Vehicle Cabin Heating

It is widely recognized in the automotive industry that, in very cold climatic conditions, the driving range of an Electric Vehicle (EV) can be reduced by 50% or more. In an effort to minimize the EV range penalty, a novel thermal energy storage system has been designed to provide cabin heating in EVs and Plug-in Hybrid Electric Vehicles (PHEVs) by using an advanced phase change material (PCM). This system is known as the Electrical PCM-based Thermal Heating System (ePATHS) [1, 2]. When the EV is connected to the electric grid to charge its traction battery, the ePATHS system is also “charged” with thermal energy. The stored heat is subsequently deployed for cabin comfort heating during driving, for example during commuting to and from work.The ePATHS system, especially the PCM heat exchanger component, has gone through substantial redesign in order to meet functionality and commercialization requirements. The final system development for EV implementation has occurred on a mid-range EV and has been evaluated for its capability to extend the driving range. Both simulated driving in a climatic tunnel and actual road testing have been carried out. The ePATHS has demonstrated its ability to supply the entire cabin heating needs for a round trip commute totaling 46 minutes, including 8 hours of parking, at an ambient temperature of -10°C.

Wang, Mingyu↗

Range Extension Opportunities While Heating a Battery Electric Vehicle

The Kia Soul battery electric vehicle (BEV) is available with either a positive temperature coefficient (PTC) heater or an R134a heat pump (HP) with PTC heater combination (1). The HP uses both ambient air and waste heat from the motor, inverter, and on-board-charger (OBC) for its heat source. Hanon Systems, Hyundai America Technical Center, Inc. (HATCI) and the National Renewable Energy Laboratory jointly, with financial support from the U.S. Department of Energy, developed and proved-out technologies that extend the driving range of a Kia Soul BEV while maintaining thermal comfort in cold climates. Improved system configuration concepts that use thermal storage and waste heat more effectively were developed and evaluated. Range extensions of 5%-22% at ambient temperatures ranging from 5 degrees C to -18 degrees C were demonstrated. This paper reviews the three-year effort, including test data of the baseline and modified vehicles, resulting range extension, and recommendations for future actions.

33 ADVANCED PROPULSION SYSTEMS↗

Numerical Methodology for Optimization of Compression-Ignited Engines Considering Combustion Noise Control

It is challenging to develop highly efficient and clean engines while meeting user expectations in terms of performance, comfort, and drivability. One of the critical aspects in this regard is combustion noise control. Combustion noise accounts for about 40 percent of the overall engine noise in typical turbocharged diesel engines. The experimental investigation of noise generation is difficult due to its inherent complexity and measurement limitations. Therefore, it is important to develop efficient numerical strategies in order to gain a better understanding of the combustion noise mechanisms. In this work, a novel methodology was developed, combining computational fluid dynamics (CFD) modeling and genetic algorithm (GA) technique to optimize the combustion system hardware design of a high-speed direct injection (HSDI) diesel engine, with respect to various emissions and performance targets including combustion noise. The CFD model was specifically set up to reproduce the unsteady pressure field inside the combustion chamber, thereby allowing an accurate prediction of the acoustic response of the combustion phenomena. The model was validated by simulating several steady operating conditions and comparing the numerical results against experimental data, in both temporal and frequency domains. Thereafter, a GA optimization was performed with the goal of minimizing indicated specific fuel consumption (ISFC) and combustion noise, while restricting pollutant (soot and NOx) emissions to their respective baseline values. Eight design variables were selected pertaining to piston bowl geometry, nozzle inclusion angle, number of injector nozzle holes, and in-cylinder swirl. An objective merit function (MF) based on the emissions, ISFC, and combustion noise was constructed to quantify the strength of the engine designs and was determined using the CFD model as the function evaluator. The in-cylinder noise level was characterized by the total resonance energy of local pressure oscillations. The optimum engine configuration thus obtained showed a significant improvement in terms of efficiency and combustion noise compared to the baseline system, along with both soot and NOx emissions within their respective constraints. This optimum configuration included a deeper and tighter bowl geometry with higher swirl and larger number of nozzle holes. Subsequently, a more detailed acoustics analysis based on proper orthogonal decomposition (POD) technique was carried out to further explore the combustion noise benefits achieved by the GA optimum. In conclusion, this computational study is a first of its kind (to the best of the authors’ knowledge), which demonstrates a comprehensive framework to incorporate combustion noise into a numerical optimization strategy for engine design.

42 ENGINEERING↗

Engine-in-the-Loop Study of a Hierarchical Predictive Online Controller for Connected and Automated Heavy-Duty Vehicles

This paper presents a cohesive set of engine-in-the-loop (EIL) studies examining the use of hierarchical model-predictive control for fuel consumption minimization in a class-8 heavy-duty truck intended to be equipped with Level-1 connectivity/automation. This work is motivated by the potential of connected/automated vehicle technologies to reduce fuel consumption in both urban/suburban and highway scenarios. The authors begin by presenting a hierarchical model-predictive control scheme that optimizes multiple chassis and powertrain functionalities for fuel consumption. These functionalities include: vehicle routing, arrival/departure at signalized intersections, speed trajectory optimization, platooning, predictive optimal gear shifting, and engine demand torque shaping. The primary optimization goal is to minimize fuel consumption, but the hierarchical controller explicitly accounts for other key objectives/constraints, including operator comfort and safe inter-vehicle spacing. This work is experimentally experimentally validated via a sequence of EIL studies intended for evaluating the computational costs and fuel savings associated with these algorithms. These EIL studies involve the closed-loop validation of the proposed control strategies, both individually and combined. These studies show that this hierarchy of algorithms is capable of running online, with the round-trip communication delay inherent in EIL simulation being one of the key factors affecting the EIL results. Moreover, the EIL studies are encouraging, both in terms of the successful hierarchical integration of the underlying algorithms and also in the resulting fuel savings seen in the EIL tests. In particular, the EIL results suggest that an aggressive overall goal of reducing vehicle fuel consumption by 15-20% or more is potentially achievable, especially in urban/suburban scenarios.

33 ADVANCED PROPULSION SYSTEMS↗

Real-World Evaluation of National Energy Efficiency Potential of Cold Storage Evaporator Technology in the Context of Engine Start-Stop Systems

National concerns over energy consumption and emissions from the transportation sector have prompted regulatory agencies to implement aggressive fuel economy targets for light-duty vehicles through the U.S. National Highway Traffic Safety Administration/Environmental Protection Agency (EPA) Corporate Average Fuel Economy (CAFE) program. Automotive manufacturers have responded by bringing competitive technologies to market that maximize efficiency while meeting or exceeding consumer performance and comfort expectations. In a collaborative effort among Toyota Motor Corporation, Argonne National Laboratory (ANL), and the National Renewable Energy Laboratory (NREL), the real-world savings of one such technology is evaluated. A commercially available Toyota Highlander equipped with two-phase cold storage technology was tested at ANL’s chassis dynamometer testing facility. The cold storage technology maintains the thermal state of air-conditioning evaporators to enable longer and more frequent engine-off operation in vehicles equipped with start-stop functionality. Test results were analyzed and provided to NREL where a novel simulation framework was developed and calibrated to the test data. The vehicle model was then exercised over a large set of real-world drive cycle and ambient condition data to estimate national-level fuel economy benefits. Results indicate that the cold storage evaporator provided national fuel consumption reductions of 0.113% relative to a conventional evaporator in the same vehicle. In addition, when the cold storage evaporator engine stop/start was enabled for any temperature and the baseline was limited to the EPA menu, Start and Stop credit assumption of 27°C, a national fuel savings of 0.497% was found. Fuel savings resulted from a combination of extended engine-off duration during idle events and increased frequency of deceleration fuel cutoff, both enabled by the ability of the cold storage evaporator to maintain thermal state in situations where air conditioning is active.

DIRECT ENERGY CONVERSION↗

Opinions from Users Across the Lifespan about Fully Autonomous and Rideshare Vehicles with Associated Features

Fully autonomous vehicles have the potential to fundamentally transform the future transportation system. While previous research has examined individuals’ perceptions towards fully autonomous vehicles, a complete understanding of attitudes and opinions across the lifespan is unknown. Therefore, individuals’ awareness, acceptance, and preferences towards autonomous vehicles were obtained from 75 participants through interviews with three diverse groups of participants: 20 automotive engineering graduate students who were building an autonomous concept vehicle, 21 non-technical adults, and 34 senior citizens. The results showed that regardless of age, an individual’s readiness to ride in a fully autonomous vehicle and the vehicle’s requirements were influenced by the users’ understanding of autonomous vehicles. All of the engineering students understand what a fully autonomous vehicle is and this group was the most willing to ride especially compared to the seniors, where only half of the seniors knew what a fully autonomous vehicle is and 58.8% were not at all ready to ride one. The desire to have a manual control option or the ability to override the vehicle was common (90% of the engineering students, 95.2% of the adults, and 82.4% of the seniors), especially for individuals who reported not being ready to ride in a fully autonomous vehicle. The majority of all three groups of participants (85% of the engineering students, 81% of the adults, and 52.9% of the seniors) considered it essential that the vehicle should convey information about the vehicle’s status and intended behavior. Diagnostic information about the vehicle was desired by the engineering students (71.4%), who had a technical understanding of autonomous vehicles and current automotive related technologies. When autonomous vehicles are available, most participants anticipate preferring to use them as a rideshare service model (75% of the engineering students, 38% of the adults, and 27% of the seniors) rather than owning (5% of the engineering students, 19% of the adults, and 21% of the seniors) the autonomous vehicle themselves. Regarding the topic of sharing rides with strangers, both the automotive engineering students (90%) and the adults (52.6%) were comfortable with the idea of pooled rideshare in comparison to the seniors (29.4%). In future efforts, it will be important to include potential autonomous vehicle users of a wide age range as well as physical, cognitive, and visual abilities.

Gangadharaiah, Rakesh↗

What Makes Passengers Uncomfortable In Vehicles Today? An Exploratory Study of Current Factors that May Influence Acceptance of Future Autonomous Vehicles

Autonomous vehicles have the potential to transform lives by providing transportation to a wider range of users. However, with this new method of transportation, user acceptance and comfort are critical for widespread adoption. This exploratory study aims to investigate what makes passengers uncomfortable in existing vehicles to inform the design of future autonomous vehicles. In order to predict what may impact user acceptance for a diverse rider population for future autonomous vehicles, it is important to understand what makes a broad range of passengers uncomfortable today. In this study, interviews were conducted for a total of 75 participants from three diverse groups, including 20 automotive engineering graduate students who are building an autonomous concept vehicle, 21 non-technical adults, and 34 senior citizens. The results revealed both topics which made different groups of passengers uncomfortable as well as how these varied between the groups. The leading contributors to the highest discomfort for all groups were being a passenger in situations with a distracted driver, being in a vehicle that is following too closely, being near a vehicle that is following too closely, and being in foggy conditions. In addition, the results showed that passenger discomfort can be attributed to a broad range of factors ranging from behaviors of the driver/vehicle that one is traveling with/in, the behaviors of other surrounding vehicles, the environmental conditions and the vehicle’s interior, all of which may differ between different groups of passengers. This research provides important findings and insights into factors that may influence users’ acceptance and use of future autonomous vehicles.

Mims, Lauren K.↗

On the predictability of turbulent fluxes from land: PLUMBER2 MIP experimental description and preliminary results

Accurate representation of the turbulent exchange of carbon, water, and heat between the land surface and the atmosphere is critical for modelling global energy, water, and carbon cycles in both future climate projections and weather forecasts. Evaluation of models' ability to do this is performed in a wide range of simulation environments, often without explicit consideration of the degree of observational constraint or uncertainty and typically without quantification of benchmark performance expectations. We describe a Model Intercomparison Project (MIP) that attempts to resolve these shortcomings, comparing the surface turbulent heat flux predictions of around 20 different land models provided with in situ meteorological forcing evaluated with measured surface fluxes using quality-controlled data from 170 eddy-covariance-based flux tower sites. Predictions from seven out-of-sample empirical models are used to quantify the information available to land models in their forcing data and so the potential for land model performance improvement. Sites with unusual behaviour, complicated processes, poor data quality, or uncommon flux magnitude are more difficult to predict for both mechanistic and empirical models, providing a means of fairer assessment of land model performance. When examining observational uncertainty, model performance does not appear to improve in low-turbulence periods or with energy-balance-corrected flux tower data, and indeed some results raise questions about whether the energy balance correction process itself is appropriate. In all cases the results are broadly consistent, with simple out-of-sample empirical models, including linear regression, comfortably outperforming mechanistic land models. In all but two cases, latent heat flux and net ecosystem exchange of CO 2 are better predicted by land models than sensible heat flux, despite it seeming to have fewer physical controlling processes. Land models that are implemented in Earth system models also appear to perform notably better than stand-alone ecosystem (including demographic) models, at least in terms of the fluxes examined here. The approach we outline enables isolation of the locations and conditions under which model developers can know that a land model can improve, allowing information pathways and discrete parameterisations in models to be identified and targeted for future model development.

54 ENVIRONMENTAL SCIENCES↗