Search NASA⌕ Search

SEARCH · Search NASA

Results for “Continuous”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Time-synchronized continuous wave laser-induced fluorescence on an oscillatory xenon discharge

A novel approach to time-synchronizing laser-induced fluorescence measurements to an oscillating current in a 60 Hz xenon discharge lamp using a continuous wave laser is presented. A sample-hold circuit is implemented to separate out signals at different phases along a current cycle, and is followed by a lock-in amplifier to pull out the resulting time-synchronized fluorescence trace from the large background signal. The time evolution of lower state population is derived from the changes in intensity of the fluorescence excitation line shape resulting from laser-induced fluorescence measurements of the 6s{sup Prime }[1/2]{sub 1}{sup 0}-6p{sup Prime }[3/2]{sub 2} xenon atomic transition at {lambda}= 834.68 nm. Results show that the lower state population oscillates at twice the frequency of the discharge current, 120 Hz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Negative ion rich plasmas in continuous and pulsed wave modes in a minimum-B magnetic field

Generation of hydrogen negative ion rich plasmas is investigated in continuous wave (CW) and pulse modulated (PM) wave modes of 2.45 GHz in a minimum-B magnetic field. The waves are launched directly into the plasma device and utilize wave particle resonances for high density plasma generation. In CW operation, the chamber is divided into two sections, namely, the source and downstream region, separated by a transverse magnetic field that allows only cold electrons ({approx}1 eV) into the downstream region helpful for the generation of negative ions. The H{sup -} density is measured by the second derivative beat method and is compared with the values obtained from a steady state model and the extracted current density. In the pulsed mode, temporal filtering generates negative ion rich plasmas in the afterglow phase. The H{sup -} density in the afterglow is estimated using saturation current ratio method and the results are compared with a time dependent model using particle balance equations. The essential idea in both the filtering techniques is to assist generation of negative ions and prevent its destruction by hot electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A double-plasma source of continuous bipolar ion-ion beam

A double-plasma source capable of the generation of a continuous bipolar ion-ion beam is described. The quasi-neutral ion-ion flow to an extraction electrode is formed in the system containing primary inductively coupled plasma separated from a secondary plasma by an electrostatic grid-type filter. The total current of each ion species to the 250 mm diameter extraction electrode is about 80 mA; the electron current does not exceed 30% of the ion current. Method of positive/negative ion current ratio control is proposed, allowing the ion currents ratio variation in wide range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectrum generating algebra for the continuous spectrum of a free particle in Lobachevski space

In this paper, we construct a Spectrum Generating Algebra (SGA) for a quantum system with purely continuous spectrum: the quantum free particle in a Lobachevski space with constant negative curvature. The SGA contains the geometrical symmetry algebra of the system plus a subalgebra of operators that give the spectrum of the system and connects the eigenfunctions of the Hamiltonian among themselves. In our case, the geometrical symmetry algebra is so(3,1) and the SGA is so(4,2). We start with a representation of so(4,2) by functions on a realization of the Lobachevski space given by a two-sheeted hyperboloid, where the Lie algebra commutators are the usual Poisson-Dirac brackets. Then, we introduce a quantized version of the representation in which functions are replaced by operators on a Hilbert space and Poisson-Dirac brackets by commutators. Eigenfunctions of the Hamiltonian are given and 'naive' ladder operators are identified. The previously defined 'naive' ladder operators shift the eigenvalues by a complex number so that an alternative approach is necessary. This is obtained by a non-self-adjoint function of a linear combination of the ladder operators, which gives the correct relation among the eigenfunctions of the Hamiltonian. We give an eigenfunction expansion of functions over the upper sheet of a two-sheeted hyperboloid in terms of the eigenfunctions of the Hamiltonian.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sparsely corrupted stimulated scattering signals recovery by iterative reweighted continuous basis pursuit

In this paper, we consider the problem of extracting the desired signals from noisy measurements. This is a classical problem of signal recovery which is of paramount importance in inertial confinement fusion. To accomplish this task, we develop a tractable algorithm based on continuous basis pursuit and reweighted ℓ{sub 1}-minimization. By modeling the observed signals as superposition of scale time-shifted copies of theoretical waveform, structured noise, and unstructured noise on a finite time interval, a sparse optimization problem is obtained. We propose to solve this problem through an iterative procedure that alternates between convex optimization to estimate the amplitude, and local optimization to estimate the dictionary. The performance of the method was evaluated both numerically and experimentally. Numerically, we recovered theoretical signals embedded in increasing amounts of unstructured noise and compared the results with those obtained through popular denoising methods. We also applied the proposed method to a set of actual experimental data acquired from the Shenguang-II laser whose energy was below the detector noise-equivalent energy. Both simulation and experiments show that the proposed method improves the signal recovery performance and extends the dynamic detection range of detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanowire-integrated microporous silicon membrane for continuous fluid transport in micro cooling device

We report an efficient passive micro pump system combining the physical properties of nanowires and micropores. This nanowire-integrated microporous silicon membrane was created to feed coolant continuously onto the surface of the wick in a micro cooling device to ensure it remains hydrated and in case of dryout, allow for regeneration of the system. The membrane was fabricated by photoelectrochemical etching to form micropores followed by hydrothermal growth of nanowires. This study shows a promising approach to address thermal management challenges for next generation electronic devices with absence of external power.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Data driven analytic continuation for one particle spectral functions

In this proceeding, an idea is outlined suggesting a generic treatment on any type of input data for a numerical analytic continuation problem, which is needed when dynamical information is to be extracted from a calculationally convenient one particle imaginary time Green function. The quality of the resulting spectral function will rely only on the data to be treated, viz, data-driven. This is different from the Maximum Entropy or the Stochastic method which relies on an entropy term to guide convergence of the resulting spectral function.

36 MATERIALS SCIENCE↗

Determination of the maximum energy loss for electron stopping power calculations and its effect on backscattering electron yield in Monte-Carlo simulations applying continuous slowing-down approximation

The maximum energy loss for electron stopping power calculations by the full Penn algorithm within the dielectric formalism is determined with taking into account the contribution of electron and plasmon excitations. Use of these calculated electron stopping powers in Monte Carlo simulations applying continuous slowing down approximation gives the backscattering electron yields in much better agreement with experimental data than previous other theoretical results. The muffin-tin model is used to describe the electron elastic scattering by atom bound in solids with taking into account the exchange correlation and polarization effect.

36 MATERIALS SCIENCE↗

The 25 mA continuous-wave surface-plasma source of H{sup −} ions

The ion source with the Penning geometry of electrodes producing continuous-wave beam of H{sup −} ions with current up to 25 mA was developed. Several improvements were introduced to increase source intensity, reliability, and lifetime. The collar around the emission aperture increases the electrons filtering. The apertures’ diameters of the ion-optical system electrodes were increased to generate the beam with higher intensity. An optimization of electrodes’ temperature was performed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative analysis of continuous-wave surface-plasma negative ion sources with various discharge geometry

Negative ion extraction from continuous-wave (CW) magnetron and semiplanotron discharges was studied and it was compared with that for the source with Penning electrode geometry. The CW negative ion beam up current to 13 mA was extracted from the magnetron source with emission aperture of 3.5 mm in diameter, while the beam with current up to 8 mA was obtained from the semiplanotron source modification. Characteristics of CW magnetron and semiplanotron sources are presented and analyzed.

43 PARTICLE ACCELERATORS↗

A double-beam magnetron-injection gun for third-harmonic continuous wave 1-THz gyrotron

The concept of a continuous wave 1-kW/1-THz gyrotron operated at the third cyclotron harmonic of the transverse electric TE{sub 9,7} operating mode has been developed. To suppress the mode competition effects in a terahertz gyrotron, we propose a scheme with two generating helical electron beams (HEBs) formed in a double-beam triode magnetron-injection gun (MIG), where both emitters of the electron beams are located on a common cathode of the conventional MIG. An optimal geometry of the MIG electrodes is found. It is shown that in a proposed scheme two HEBs having close pitch factors and a moderate velocity spread can be formed. This makes them suitable for high-efficiency single-mode generation in the high frequency gyrotron at high harmonic.

43 PARTICLE ACCELERATORS↗

Continuous-wave quasi-phase-matched waveguide correlated photon pair source on a III–V chip

We report on the demonstration of correlated photon pair generation in a quasi-phase-matched superlattice GaAs/AlGaAs waveguide using a continuous-wave pump. Our photon pair source has a low noise level and achieves a high coincidence-to-accidental ratio greater than 100, which is the highest value reported in III–V chips so far. This correlated photon pair source has the potential to be monolithically integrated with on-chip pump laser sources fabricated on the same superlattice wafer structure, enabling direct correlated/entangled photon pair production from a compact electrically powered chip.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of frequency modulated continuous wave reflectometer for electron density profile measurement on the HL-2A tokamak

The frequency modulated continuous wave reflectometer was developed for the first time on the HL-2A tokamak. The system utilizes a voltage controlled oscillator and an active multiplier for broadband coverage and detects as heterodyne mode. Three reflectometers have been installed and operated in extraordinary mode polarization on HL-2A to measure density profiles at low field side, covering the Q-band (33–50 GHz), V-band (50–75 GHz), and W-band (75–110 GHz). For density profile reconstruction from the phase shift of the probing wave, a corrected phase unwrapping method is introduced in this article. The effectiveness of the method is demonstrated. The density profile behavior of a fast plasma event is presented and it demonstrates the capability of the reflectometer. These diagnostics will be contributed to the routine density profile measurements and the plasma physics study on HL-2A.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High performance continuous wave 1.3 μm quantum dot lasers on silicon

We demonstrate record performance 1.3 μm InAs quantum dot lasers grown on silicon by molecular beam epitaxy. Ridge waveguide lasers fabricated from the as-grown material achieve room temperature continuous wave thresholds as low as 16 mA, output powers exceeding 176 mW, and lasing up to 119 °C. P-modulation doping of the active region improves T{sub 0} to the range of 100–200 K while maintaining low thresholds and high output powers. Device yield is presented showing repeatable performance across different dies and wafers.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High power and high temperature continuous-wave operation of distributed Bragg reflector quantum cascade lasers

High temperature continuous-wave (CW) operation of a distributed Bragg reflector (DBR) quantum cascade laser is demonstrated up to a heat sink temperature of 80 °C. A CW output power of 2 W and a single mode operation with side mode suppression ratio of 30 dB around wavelength of 4.48 μm were achieved at 20 °C. The maximum pulsed and CW wall-plug-efficiencies reached 14.7% and 10.3% at 20 °C, respectively. A large tuning range of 5 cm{sup −1} between mode hopping was observed and attributed to the thermal cross-talk from the gain section to the DBR section.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pump and probe spectroscopy with continuous wave quantum cascade lasers

This paper details infra-red pump and probe studies on nitric oxide conducted with two continuous wave quantum cascade lasers both operating around 5 μm. The pump laser prepares a velocity selected population in a chosen rotational quantum state of the v = 1 level which is subsequently probed using a second laser tuned to a rotational transition within the v = 2 ← v = 1 hot band. The rapid frequency scan of the probe (with respect to the molecular collision rate) in combination with the velocity selective pumping allows observation of marked rapid passage signatures in the transient absorption profiles from the polarized vibrationally excited sample. These coherent transient signals are influenced by the underlying hyperfine structure of the pump and probe transitions, the sample pressure, and the coherent properties of the lasers. Pulsed pump and probe studies show that the transient absorption signals decay within 1 μs at 50 mTorr total pressure, reflecting both the polarization and population dephasing times of the vibrationally excited sample. The experimental observations are supported by simulation based upon solving the optical Bloch equations for a two level system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface-emitting terahertz quantum cascade lasers with continuous-wave power in the tens of milliwatt range

We demonstrate efficient surface-emitting terahertz frequency quantum cascade lasers with continuous wave output powers of 20–25 mW at 15 K and maximum operating temperatures of 80–85 K. The devices employ a resonant-phonon depopulation active region design with injector, and surface emission is realized using resonators based on graded photonic heterostructures (GPHs). GPHs can be regarded as energy wells for photons and have recently been implemented through grading the period of the photonic structure. In this paper, we show that it is possible to keep the period constant and grade instead the lateral metal coverage across the GPH. This strategy ensures spectrally single-mode operation across the whole laser dynamic range and represents an additional degree of freedom in the design of confining potentials for photons.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of three-wavelength CCD image pyrometer used for the temperature field measurements of continuous casting billets

This paper develops an imaging based three-color pyrometer for the monitoring of temperature distribution in a continuous casting billet. A novel optical device, together with an embedded electronic system, is designed to sequentially collect a dark image and three thermal images with specified wavelengths on a same monochromatic charge-coupled-device (CCD). The three thermal images provide the basis for the determination of target temperature, while the dark image is used to online eliminate the dark noise of CCD with a differential method. This image pyrometer is not only independent of target emissivity but also overcomes the dissimilarity of measuring accuracy between the micro-sensors of CCD resulted from the non-uniformity of pixels’ intensity response and the vignetting of optical system. Furthermore, a precise two-color temperature field measuring model on the CCD pyrometer is established, based on which a self-adaptive light-integration mechanism is presented. Compared with the traditional fixed light-integration method, the measuring range of the pyrometer is greatly extended and its sensitivity in low temperature segment is improved. The test results in a steel factory demonstrate that the pyrometer is capable of meeting the requirement of surface temperature measurements about casting billets. Reliability and accuracy of measurement results are also discussed herein.

42 ENGINEERING↗