Potential Source Apportionment and Meteorological Conditions Involved in Airborne 131 I Detections in January/February 2017 in Europe

Traces of particulate radioactive iodine (I-131) were detected in the European atmosphere in January/February 2017. Concentrations of this nuclear fission product were very low, ranging 0.1 to 10 mu Bq m(-3) except at one location in western Russia where they reached up to several mBq m(-3). Detections have been reported continuously over an 8-week period by about 30 monitoring stations. We examine possible emission source apportionments and rank them considering their expected contribution in terms of orders of magnitude from typical routine releases: radiopharmaceutical production units > sewage sludge incinerators > nuclear power plants > spontaneous fission of uranium in soil. Inverse modeling simulations indicate that the widespread detections of I-131 resulted from the combination of multiple source releases. Among them, those from radiopharmaceutical production units remain the most likely. One of them is located in Western Russia and its estimated source term complies with authorized limits. Other existing sources related to I-131 use (medical purposes or sewage sludge incineration) can explain detections on a rather local scale. As an enhancing factor, the prevailing wintertime meteorological situations marked by strong temperature inversions led to poor dispersion conditions that resulted in higher concentrations exceeding usual detection limits in use within the informal Ring of Five (Ro5) monitoring network.

54 ENVIRONMENTAL SCIENCES↗

Engineering a new tripartite split-ccGFP system from Corynactis californica for detecting protein–protein interactions

Protein-protein interactions (PPIs) are critical to a range of biological processes and, consequently, aberrant interactions are implicated in many disorders. The study of the complex networks of PPIs promises to elucidate undiscovered roles in cellular processes and the mechanisms of disease. To accomplish this, tools to effectively sense PPIs are necessary. Effective PPI sensors must rapidly detect interactions in real-time with high sensitivity without perturbing the proteins of interest (POIs) under study. Split fluorescent proteins have previously been used to successfully monitor PPIs, in part due to the small size of the tags. Here, we developed an optimized tripartite split GFP system based on Corynactis californica GFP (ccGFP) to detect PPIs in vitro. In this sensor system, ccGFP fragments ccGFP10 and ccGFP11 are tagged to two POIs. PPIs can then be detected via fluorescence by complementation to the third fragment, ccGFP1-9, which reconstitutes functional ccGFP. The optimized ccGFP system shows improved detection kinetics and pH and temperature stability compared to a previous system. We then validated the sensor by monitoring PPIs in two model systems: attractive/repulsive coiled-coils and rapamycin-inducible FRB/FKBP heterodimerization. Finally, we developed an anti-tripartite ccGFP single-chain variable fragment (scFv), which could enable versatile detection of identified protein-protein complexes.

59 BASIC BIOLOGICAL SCIENCES↗

Detecting bacteria and Determining Their Susceptibility to Antibiotics by Stochastic Confinement in Nanoliter Droplets using Plug-Based Microfluidics

This article describes plug-based microfluidic technology that enables rapid detection and drug susceptibility screening of bacteria in samples, including complex biological matrices, without pre-incubation. Unlike conventional bacterial culture and detection methods, which rely on incubation of a sample to increase the concentration of bacteria to detectable levels, this method confines individual bacteria into droplets nanoliters in volume. When single cells are confined into plugs of small volume such that the loading is less than one bacterium per plug, the detection time is proportional to plug volume. Confinement increases cell density and allows released molecules to accumulate around the cell, eliminating the pre-incubation step and reducing the time required to detect the bacteria. We refer to this approach as stochastic confinement. Using the microfluidic hybrid method, this technology was used to determine the antibiogram - or chart of antibiotic sensitivity - of methicillin-resistant Staphylococcus aureus (MRSA) to many antibiotics in a single experiment and to measure the minimal inhibitory concentration (MIC) of the drug cefoxitin (CFX) against this strain. In addition, this technology was used to distinguish between sensitive and resistant strains of S. aureus in samples of human blood plasma. High-throughput microfluidic techniques combined with single-cell measurements also enable multiple tests to be performed simultaneously on a single sample containing bacteria. This technology may provide a method of rapid and effective patient-specific treatment of bacterial infections and could be extended to a variety of applications that require multiple functional tests of bacterial samples on reduced timescales.

59 BASIC BIOLOGICAL SCIENCES↗

ULTRASONIC DETECTION OF SURFACE-BREAKING RAILHEAD DEFECTS

We recently presented measurements of defects on the railhead, using a novel pitch-catch ultrasonic system comprising of two electro-magnetic acoustic transducers (EMATs) generating and detecting Rayleigh waves. Current systems used on the UK rail network for detecting surface breaking defects are limited in speed (<30 mph) and accuracy (depths >5 mm). The non-contact EMAT system has the potential to operate at higher line speed, improving network inspection coverage. The current system detects signals and performs an FFT in less than 1 ms, and changes in the detected signal amplitude and frequency content are used to characterise defects. A new set of simulated defects on sections of rail have been produced, including half-face slots machined normal to the railhead surface, clusters of angled slots, and pocket defects more typical of real defects. The smallest pocket defects are difficult to detect, with changes in signal amplitude and cut-off falling close to the noise level. However, at chosen higher frequencies a drop in FFT magnitude indicates the presence of a defect, and this indicator can be logically combined with amplitude and cut-off measurements to provide a more reliable result. Preparation for testing on a rotating rail rig at high speeds is ongoing.

36 MATERIALS SCIENCE↗

DETECTION OF LACK OF FUSION WELD DEFECTS BY RADIOGRAPHY

In this work, radiography was employed as the NDT technique for detection of flaws in circumferential girth welds of steel pipelines used in offshore installations in the petroleum industry. The kind of defect specifically focused was lack of fusion. It is currently accepted in the literature that radiography is not as sensitive as ultrasonics to detect lack of fusion defects. Unfortunately, the radiographic inspection can barely detect lack of fusion and only when it is associated to inclusions and voids of considerable size. However, in a previous article ('Reliability of radiographic inspection of steel pipeline girth welds', QNDE Conference, 2007), the authors showed that it is possible to detect lack of fusion defects if, in the radiographic tests, the angle of incidence is the same angle that the weld bevel makes with the test piece surface, which means lowering the angle of disorientation between the flaw and the radiographic beam. However, no concerns were made to sizing the defects. Computational simulation was used with XRSIM software to establish the optimal radiographic parameters to reach the lower limit for detection for this kind of defect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Indirect detections and analyses of GRBs by ionospheric response

We report on the independent and indirect detection of GRBs by their ionospheric response (SID--Sudden Ionospheric Disturbance) observed at VLF (Very Low Frequency), and discus its possible impact on GRB science and investigations in general. Although few such detections have been already reported in the past, the capability of such alternative and indirect investigations of GRBs still remains to be investigated in more details. We present and discuss examples of such VLF/SID detection of GRBs 060124A, GRB080319D a GRB080320A. A network of SID monitors has been created and is operated to detect more GRBs. The importance of these detections for GRB analyses and GRB science in general is still to be further and in full detail exploited. Some possible outcomes in this direction will be outlined and discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Indirect detections and analyses of GRBs by ionospheric response

We present and discuss the independent and indirect detection of GRBs by their ionospheric response (SID--Sudden Ionospheric Disturbance) observed at VLF (Very Low Frequency), and evaluate its possible impact on GRB science and investigations in general. Although few such detections have been already reported in the past, the capability of such alternative and indirect investigations of GRBs still remains to be investigated in more details. We present and discuss examples of such VLF/SID detection of GRBs 060124A, GRB080319D a GRB080320A. A network of SID monitors has been created and is operated to detect more GRBs. The importance of these detections for GRB analyses and GRB science in general is still to be further and in full detail exploited.

79 ASTRONOMY AND ASTROPHYSICS↗

Surface Detection in a STXM Microscope

We have modified scanning transmission x-ray microscopes (STXM) at the Canadian Light Source and the Advanced Light Source with total electron yield (TEY) detection (TEY-STXM). This provides improved surface-sensitive detection, simultaneous with existing bulk-sensitive transmission detection in the STXM microscopes. We have explored sample-current and channeltron-based electron yield detection. Both approaches provide improved surface sensitive imaging and spectroscopy, although channeltron-based detection is superior. TEY-STXM provides surface sensitive imaging of ultrathin films such as phase-separated Langmuir-Blodgett monolayer films, as well as differentiation of surface and bulk oxides of patterned metallic thin films. This paper will outline the experimental challenges of this method and the opportunities for correlative surface and bulk measurements of complex samples.

07 ISOTOPE AND RADIATION SOURCES↗

A bubble detection system for propellant filling pipeline

This paper proposes a bubble detection system based on the ultrasound transmission method, mainly for probing high-speed bubbles in the satellite propellant filling pipeline. First, three common ultrasonic detection methods are compared and the ultrasound transmission method is used in this paper. Then, the ultrasound beam in a vertical pipe is investigated, suggesting that the width of the beam used for detection is usually smaller than the internal diameter of the pipe, which means that when bubbles move close to the pipe wall, they may escape from being detected. A special device is designed to solve this problem. It can generate the spiral flow to force all the bubbles to ascend along the central line of the pipe. In the end, experiments are implemented to evaluate the performance of this system. Bubbles of five different sizes are generated and detected. Experiment results show that the sizes and quantity of bubbles can be estimated by this system. Also, the bubbles of different radii can be distinguished from each other. The numerical relationship between the ultrasound attenuation and the bubble radius is acquired and it can be utilized for estimating the unknown bubble size and measuring the total bubble volume.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High repetition rate laser-induced breakdown spectroscopy using acousto-optically gated detection

This contribution introduces a new type of setup for fast sample analysis using laser-induced breakdown spectroscopy (LIBS). The novel design combines a high repetition rate laser (up to 50 kHz) as excitation source and an acousto-optical modulator (AOM) as a fast switch for temporally gating the detection of the emitted light. The plasma radiation is led through the active medium of the AOM where it is diffracted on the transient ultrasonic Bragg grid. The diffracted radiation is detected by a compact Czerny-Turner spectrometer equipped with a CCD line detector. Utilizing the new combination of high repetition rate lasers and AOM gated detection, rapid measurements with total integration times of only 10 ms resulted in a limit of detection (LOD) of 0.13 wt.% for magnesium in aluminum alloys. This short integration time corresponds to 100 analyses/s. Temporal gating of LIP radiation results in improved LODs and consecutively higher sensitivity of the LIBS setup. Therefore, an AOM could be beneficially utilized to temporally detect plasmas induced by high repetition rate lasers. The AOM in combination with miniaturized Czerny-Turner spectrometers equipped with CCD line detectors and small footprint diode pumped solid state lasers results in temporally gateable compact LIBS setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single molecule transistor based nanopore for the detection of nicotine

A nanopore based detection methodology was proposed and investigated for the detection of Nicotine. This technique uses a Single Molecular Transistor working as a nanopore operational in the Coulomb Blockade regime. When the Nicotine molecule is pulled through the nanopore area surrounded by the Source(S), Drain (D), and Gate electrodes, the charge stability diagram can detect the presence of the molecule and is unique for a specific molecular structure. Due to the weak coupling between the different electrodes which is set by the nanopore size, the molecular energy states stay almost unaffected by the electrostatic environment that can be realised from the charge stability diagram. Identification of different orientation and position of the Nicotine molecule within the nanopore area can be made from specific regions of overlap between different charge states on the stability diagram that could be used as an electronic fingerprint for detection. This method could be advantageous and useful to detect the presence of Nicotine in smoke which is usually performed using chemical chromatography techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detecting brain tumor in computed tomography images using Markov random fields and fuzzy C-means clustering techniques

Brain tumors, are an abnormal growth of tissues in the brain. They may arise in people of any age. They must be detected early, diagnosed accurately, monitored carefully, and treated effectively in order to optimize patient outcomes regarding both survival and quality of life. Manual segmentation of brain tumors from CT scan images is a challenging and time consuming task. Size and location accurate detection of brain tumor plays a vital role in the successful diagnosis and treatment of tumors. Brain tumor detection is considered a challenging mission in medical image processing. The aim of this paper is to introduce a scheme for tumor detection in CT scan images using two different techniques Hidden Markov Random Fields (HMRF) and Fuzzy C-means (FCM). The proposed method has been developed in this research in order to construct hybrid method between (HMRF) and threshold. These methods have been applied on 4 different patient data sets. The result of comparison among these methods shows that the proposed method gives good results for brain tissue detection, and is more robust and effective compared with (FCM) techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detection of dark states in two-dimensional electronic photon-echo signals via ground-state coherence

Several recent experiments report on possibility of dark-state detection by means of so called beating maps of two-dimensional photon-echo spectroscopy [Ostroumov et al., Science 340, 52 (2013); Bakulin et al., Ultrafast Phenomena XIX (Springer International Publishing, 2015)]. The main idea of this detection scheme is to use coherence induced upon the laser excitation as a very sensitive probe. In this study, we investigate the performance of ground-state coherence in the detection of dark electronic states. For this purpose, we simulate beating maps of several models where the excited-state coherence can be hardly detected and is assumed not to contribute to the beating maps. The models represent strongly coupled electron-nuclear dynamics involving avoided crossings and conical intersections. In all the models, the initially populated optically accessible excited state decays to a lower-lying dark state within few hundreds femtoseconds. We address the role of Raman modes and of interstate-coupling nature. Our findings suggest that the presence of low-frequency Raman active modes significantly increases the chances for detection of dark states populated via avoided crossings, whereas conical intersections represent a more challenging task.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Muon detection studied by pulse-height energy analysis: Novel converter arrangements

Muons are conventionally measured by a plastic scintillator–photomultiplier detector. Muons from processes in ultra-dense hydrogen H(0) are detected here by a novel type of converter in front of a photomultiplier. The muon detection yield can be increased relative to that observed with a plastic scintillator by at least a factor of 100, using a converter of metal, semiconductor (Ge), or glass for interaction with the muons penetrating through the metal housing of the detector. This detection process is due to transient formation of excited nuclei by the well-known process of muon capture, giving beta decay. The main experimental results shown here are in the form of beta electron energy spectra detected directly by the photomultiplier. Events which give a high-energy tail in the energy spectra are probably due to gamma photons from the muons. Sharp and intense x-ray peaks from a muonic aluminium converter or housing material are observed. The detection conversion in glass and Ge converters has a time constant of the order of many minutes to reach the final conversion level, while the process in metal converters is stabilized faster. The time constants are not due to lifetimes of the excited nuclei or neutrons but are due to internal charging in the insulating converter material. Interaction of this charging with the high voltage in the photomultiplier is observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient and robust quantum random number generation by photon number detection

We present an efficient and robust quantum random number generator based upon high-rate room temperature photon number detection. We employ an electric field-modulated silicon avalanche photodiode, a type of device particularly suited to high-rate photon number detection with excellent photon number resolution to detect, without an applied dead-time, up to 4 photons from the optical pulses emitted by a laser. By both measuring and modeling the response of the detector to the incident photons, we are able to determine the illumination conditions that achieve an optimal bit rate that we show is robust against variation in the photon flux. We extract random bits from the detected photon numbers with an efficiency of 99% corresponding to 1.97 bits per detected photon number yielding a bit rate of 143 Mbit/s, and verify that the extracted bits pass stringent statistical tests for randomness. Our scheme is highly scalable and has the potential of multi-Gbit/s bit rates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-frequency energy density precipitation method for time-of-flight extraction of narrowband Lamb wave detection signals

The time-of-flight of the Lamb wave provides an important basis for defect evaluation in metal plates and is the input signal for Lamb wave tomographic imaging. However, the time-of-flight can be difficult to acquire because of the Lamb wave dispersion characteristics. This work proposes a time-frequency energy density precipitation method to accurately extract the time-of-flight of narrowband Lamb wave detection signals in metal plates. In the proposed method, a discrete short-time Fourier transform is performed on the narrowband Lamb wave detection signals to obtain the corresponding discrete time-frequency energy density distribution. The energy density values at the center frequency for all discrete time points are then calculated by linear interpolation. Next, the time-domain energy density curve focused on that center frequency is precipitated by least squares fitting of the calculated energy density values. Finally, the peak times of the energy density curve obtained relative to the initial pulse signal are extracted as the time-of-flight for the narrowband Lamb wave detection signals. An experimental platform is established for time-of-flight extraction of narrowband Lamb wave detection signals, and sensitivity analysis of the proposed time-frequency energy density precipitation method is performed in terms of propagation distance, dispersion characteristics, center frequency, and plate thickness. For comparison, the widely used Hilbert–Huang transform method is also implemented for time-of-flight extraction. The results show that the time-frequency energy density precipitation method can accurately extract the time-of-flight with relative error of <1% and thus can act as a universal time-of-flight extraction method for narrowband Lamb wave detection signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo Dropout Uncertainty Quantification of Long Short-Term Memory Autoencoder Anomaly Detection in a Liquid Sodium Cold Trap

Advanced high-temperature fluid reactors, such as sodium-cooled fast reactors (SFRs) and molten salt–cooled reactors (MSCRs), require coolant purification systems to prevent fluid contamination and local freezing that can lead to plugging. Liquid sodium purification can be achieved with a cold trap, where the sodium temperature is reduced to a near-freezing point to precipitate out impurities. Automation of monitoring of the cold trap performance with machine learning algorithms can aid in early detection of incipient anomalies. An efficient approach to loss-of-coolant–type anomaly detection in a cold trap monitored with more than two dozen thermal-hydraulic sensors consists of a long short-term memory (LSTM) autoencoder. This work develops the uncertainty quantification of the LSTM autoencoder performance for cold trap anomaly detection using the Monte Carlo (MC) dropout method. The MC dropout methodology creates a distribution of sister distributions that all slightly differ from each other because of random neurons being turned off for testing. The variances of the sister network distributions are used to make an uncertainty interval. Our analysis shows that the uncertainty in the autoencoder performance is largest near the peak of the anomaly signal. Using the MC dropout method, we investigate the uncertainty in the anomaly detection with missing sensor inputs. This capability allows the reactor operator to evaluate resilience of the anomaly detection system and to make informed decisions about continuity of operation in the event of sensor failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

DETECTION OF KOI-13.01 USING THE PHOTOMETRIC ORBIT

We use the KOI-13 transiting star-planet system as a test case for the recently developed BEER algorithm, aimed at identifying non-transiting low-mass companions by detecting the photometric variability induced by the companion along its orbit. Such photometric variability is generated by three mechanisms: the beaming effect, tidal ellipsoidal distortion, and reflection/heating. We use data from three Kepler quarters, from the first year of the mission, while ignoring measurements within the transit and occultation, and show that the planet's ephemeris is clearly detected. We fit for the amplitude of each of the three effects and use the beaming effect amplitude to estimate the planet's minimum mass, which results in M{sub p} sin i = 9.2 {+-} 1.1 M{sub J} (assuming the host star parameters derived by Szabo et al.). Our results show that non-transiting star-planet systems similar to KOI-13.01 can be detected in Kepler data, including a measurement of the orbital ephemeris and the planet's minimum mass. Moreover, we derive a realistic estimate of the amplitudes uncertainties, and use it to show that data obtained during the entire lifetime of the Kepler mission of 3.5 years will allow detecting non-transiting close-in low-mass companions orbiting bright stars, down to the few Jupiter mass level. Data from the Kepler Extended Mission, if funded by NASA, will further improve the detection capabilities.

79 ASTRONOMY AND ASTROPHYSICS↗