Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

In Situ High-Temperature Ultrafast Electron Diffraction through Integrated Furnace and MEMS Platforms

Temperature fundamentally governs phase stability, defect evolution, and transport behavior in materials. Despite its central role, direct measurements of structural evolution at elevated temperatures on ultrafast timescales have remained limited. Here, we report the design, integration, and validation of 2 complementary in situ heating platforms that substantially extend the thermal operating range of ultrafast electron diffraction (UED). A compact furnace-type heating stage enables stable diffraction measurements from room temperature to 800 K with ±0.1 K stability under ultrahigh vacuum, achieved through multi-sensor feedback control, dual air-cooling channels, and a thermally isolated motion stage. In parallel, a microelectromechanical system (MEMS)-based heating platform provides rapid thermal response and access to extreme temperatures ≥1,373 K with ±0.1 K stability over hundreds-micrometer regions while supporting simultaneous electrical biasing for electrothermal coupling studies. Absolute temperature calibration is established using diffraction-based thermometry via aluminum lattice expansion and independently validated through in situ melting of bismuth thin films. UED measurements further reveal pronounced temperature-dependent nonequilibrium lattice dynamics in bismuth, including modifications to electron–phonon coupling and Debye–Waller behavior, as well as enhanced ultrafast diffuse scattering in aluminum at elevated temperatures. Together, these developments establish a practical framework for quantitative, time-resolved studies of temperature-driven kinetics and nonequilibrium structural dynamics under extreme thermal environments.

Bai, Qianqian [Chinese Academy of Sciences (CAS), ↗

Quantitative Uncertainty Analysis for Diffraction

Current software uses a least squares statistical method. For each model parameter, current software yields a point estimate and estimated standard error for each point estimate. In contrast, we have employed a Bayesian approach with sampling algorithm to provide a full posterior probability density function on each model parameter. This yields a different type of solution (probabilistic) with better fidelity. The Quantitative Uncertainty Analysis for Diffraction (QUAD) package returns a matrix of affect model parameters as a function of iteration through the MCMC analysis. QUAD is a Python code that allows for analysis of X-ray and neutron diffraction data to infer the structure of materials with quantifiable certainty. The code uses Bayesian statistics and Markov chain sampling algorithms to create posterior probability distributions on all material structure parameters that are modeled by a researcher. The statistical packages use the open source GSASII project as a library to calculate model diffraction patterns.

Fancher, ChristopherM↗

Combined high-pressure neutron and X-ray diffraction study of H-D substitution effects on brucite

The high-pressure behavior of the mineral brucite, Mg(OH)2, is of great geochemical and geophysical interest, because brucite-type minerals serve as a simple analog for more complex, hydrogen-bearing oxide and silicate minerals in the deep-earth. A combined neutron and synchrotron x-ray powder diffraction study of hydrogenated and deuterated brucite was conducted at ambient temperature and at pressures to 9 and 20 GPa, using a Paris-Edinburgh (neutron diffraction) and a diamond anvil cell (synchrotron x-ray radiation), respectively. The two materials were synthesized by the same method and companion diffraction measurements of the two materials were conducted under the same conditions. Our experimental results show that the lattice-parameters of the a axis, parallel to the sheets of Mg-O octahedra, decrease only slightly with pressure with no effect of H-D substitution. However, the c axis of Mg (OD)2 is shorter and may exhibit greater compressibility with pressure than that of Mg (OH)2. Consequently, the unit-cell volume of deuterated brucite is slightly, but systematically smaller than that of hydrogenated brucite. Fitting to a third-order Birch-Murnaghan equation shows that values of the bulk modulus for hydrogenated and deuterated brucite are indistinguishable from each other within the experimental errors. The measured effect of H-D substitution on the unit-cell volume demonstrates that brucite (and other hydrous minerals) preferentially incorporate deuterium over hydrogen under pressure, suggesting that the distribution of hydrogen isotopes in deep-earth conditions may differ significantly from that in near-surface environments.

Brucite↗

Ultra-high density diffraction grating

A diffraction grating structure having ultra-high density of grooves comprises an echellette substrate having periodically repeating recessed features, and a multi-layer stack of materials disposed on the echellette substrate. The surface of the diffraction grating is planarized, such that layers of the multi-layer stack form a plurality of lines disposed on the planarized surface of the structure in a periodical fashion, wherein lines having a first property alternate with lines having a dissimilar property on the surface of the substrate. For example, in one embodiment, lines comprising high-Z and low-Z materials alternate on the planarized surface providing a structure that is suitable as a diffraction grating for EUV and soft X-rays. In some embodiments, line density of between about 10,000 lines/mm to about 100,000 lines/mm is provided.

36 MATERIALS SCIENCE↗

High-Energy X-Ray Diffraction Analysis Tool

The functionality of heRXD includes the following: distance and angular calibration and viewing flat-panel detector images used for X-ray diffraction; image (polar) rebinning or "caking"; line position fitting in powder diffraction images; image segmentation or "blob finding"; crystal orentation indesing; and lattice vector refinement. These functionalities encompass a critical set analyzing teh data for high-energy diffraction measurements that are currently performed at synchrotron sources such as the Advanced Photon Source (APS). The software design modular and open source under LGPL. The intent is to provide a common framework and graphical user interface that has the ability to utillize internal as well as external subroutines to provide various optins for performing the fuctionalities listed above. The software will initially be deployed at several national user facilities--including APS, ALS, and CHESS--and then made available for download using a hosting service such as sourceforge.

Source record↗

Imaging Based Detector with Efficient Scintillators for Neutron Diffraction Measurements

The Anger Camera developed by the detector group at the Oak Ridge National Laboratory was utilized for the present work for its unique advantage of employing multiple modules to obtain large active measurement area for detecting diffracted/scattered thermal neutrons. Considering the relatively small flux associated with diffracted/scattered neutrons, suitable efficiency with high spatial resolution is a requirement for utilizing two-dimensional imaging detectors. The potential to implement pulse shape (in addition to pulse height) discrimination-based scintillators further enhances the ability to detect diffracted neutrons with improved signal to noise ratio. In this paper, initial results associated with 6Li glass-based scintillator will be presented. The authors explored the feasibility of using this system to detect and quantify diffraction peaks and peak shifts at the Neutron Residual Stress Facility (NRSF2), High Flux Isotope Reactor (HFIR) in the Oak Ridge National Laboratory (ORNL). Suitable camera mounting and shielding had to be developed. Reference measurements using polycrystalline powders with known atomic planar spacing will be discussed along with measurement settings associated with expected resolution for peak shift measurements. Initial results are promising and demonstrate that a suitable scintillation-based neutron detecting system is viable for residual stress-based diffraction measurements. Small area detectors are also feasible with suitable consideration to scattering volume and distance to detector.

Seals, Matthew↗

In-situ neutron diffraction study of phase stress evolutions in a Ni-basedporous anode under uniaxial load

Ni/YSZ porous composite is used widely as anode for solid oxide fuel cells. In this study, neutron diffraction patterns were recorded in-situ while a bulk porous Ni-NiO-YSZ anode was loaded under uniaxial compression. Single peak refinement was used to calculate the lattice strains of each phase in the composite, and the local stress state of each phase was derived from the measured lattice strains and the corresponding diffraction elastic constants. An internal triaxial stress state was observed to develop in the bulk of the specimen under plastic deformation, specifically in the Ni phase. Meanwhile, the NiO and YSZ phases are deforming elastically even in the macroscopically plastic regime of deformation. The von Mises equivalent stress was used to quantify the phase stress evolution. A significant stress concentration induced by the presence of pores becomes manifest in all three phase components. The reduction of stress concentration factor in Ni above the yield point of the composite can be attributed to a gradual change of the grains-pores morphology during the plastic deformation.

30 DIRECT ENERGY CONVERSION↗

In-Situ X-Ray Diffraction Observations of Low Temperature Ag-Nanoink Sintering and High Temperature Eutectic Reaction with Copper

Nanoinks, which contain nm sized metallic particles suspended in an organic dispersant fluid, are finding numerous microelectronic applications. Nanoinks sinter at much lower temperatures than bulk metals due to their high surface area to volume ratio and small radius of curvature, which reduces their melting points significantly below their bulk values. The unusually low melting and sintering temperatures have unique potential for materials joining since their melting points increase dramatically after initial sintering. In this paper Ag nanoink is studied using in-situ synchrotron based x-ray diffraction to follow the kinetics of the initial sintering step by analysis of diffraction patterns, and to directly observe the high remelt temperature of sintered nanoinks. Ag nanoink is further explored as a possible eutectic bonding medium with copper by tracking phase transformations to high temperatures where melting occurs at the Ag-Cu eutectic temperature, demonstrating nanoinks as a viable eutectic bonding medium.

36 MATERIALS SCIENCE↗

In-Situ Studies of Intercritically Austempered Ductile Iron Using Neutron Diffraction

Intercritically austempered ductile irons hold promise for applications requiring fatigue durability, excellent castability, low production energy requirements, reduced greenhouse gas emissions and excellent machinability. In the present study, four different ductile iron alloys, containing manganese and nickel as the primary austenite-stabilizing elements, were heat treated to obtain different quantities of austenite in the final microstructure. This paper reports the microstructures and phases present in these alloys. Further, lattice strains and diffraction elastic constants in various crystallographic directions and the transformation characteristics of the austenite as a function of applied stress were determined using in-situ loading with neutron diffraction at the second generation Neutron Residual Stress Facility (NRSF2) at the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL).

36 MATERIALS SCIENCE↗

Effect of Breast Compression on Lesion Characteristic Visibility with Diffraction-Enhanced Imaging

Conventional mammography can not distinguish between transmitted, scattered, or refracted x-rays, thus requiring breast compression to decrease tissue depth and separate overlapping structures. Diffraction-enhanced imaging (DEI) uses monochromatic x-rays and perfect crystal diffraction to generate images with contrast based on absorption, refraction, or scatter. Because DEI possesses inherently superior contrast mechanisms, the current study assesses the effect of breast compression on lesion characteristic visibility with DEI imaging of breast specimens. Eleven breast tissue specimens, containing a total of 21 regions of interest, were imaged by DEI uncompressed, half-compressed, or fully compressed. A fully compressed DEI image was displayed on a soft-copy mammography review workstation, next to a DEI image acquired with reduced compression, maintaining all other imaging parameters. Five breast imaging radiologists scored image quality metrics considering known lesion pathology, ranking their findings on a 7-point Likert scale. When fully compressed DEI images were compared to those acquired with approximately a 25% difference in tissue thickness, there was no difference in scoring of lesion feature visibility. For fully compressed DEI images compared to those acquired with approximately a 50% difference in tissue thickness, across the five readers, there was a difference in scoring of lesion feature visibility. The scores for this difference in tissue thickness were significantly different at one rocking curve position and for benign lesion characterizations. These results should be verified in a larger study because when evaluating the radiologist scores overall, we detected a significant difference between the scores reported by the five radiologists. Reducing the need for breast compression might increase patient comfort during mammography. Our results suggest that DEI may allow a reduction in compression without substantially compromising clinical image quality.

59 BASIC BIOLOGICAL SCIENCES↗

An in-situ high-energy X-ray diffraction study of micromechanical behavior of multiple phases in advanced high-strength steels

For multiphase advanced high-strength steels, the different mechanical behavior of constituent phases may lead to a non-uniform partitioning of stresses among different phases. In addition, the grain-orientation-dependent elastic/plastic anisotropy in each phase may cause the grain-to-grain interactions, which further modify further the microscopic load partitioning. In the current work, the micromechanical behavior of high-strength steels with multiple phases was characterized by using the in-situ high-energy X-ray diffraction (HEXRD) technique. For the investigated materials, the {200} lattice strains of the constituent phases (the ferrite, bainite, and martensite) with similar crystal structures were determined through separating their overlapped diffraction peaks and, then, examining the respective changes of peak positions during deformation. Based on those experimental data, the anisotropic elastic and plastic properties of the steels were simulated using a Self-Consistent (SC) model for predicting the grain-to-grain and phase-to-phase interactions. The constitutive laws for describing the elastic and plastic behavior of each constituent phase were directly obtained through comparing the predicted lattice- strain distributions with the measured ones. The transmission-electron-microscopy (TEM) observations of the microstructure developments of microstructures also verified the partitioning of plastic strains among different phases. The present investigations provide a good fundamental understanding of the micromechanical behavior, with an emphasis on the stress partitioning of soft and hard phases, and different work-hardening rates, of the studied steels during tensile loading.

36 MATERIALS SCIENCE↗

Multiscale mechanical fatigue damage of stainless steel investigated by neutron diffraction and X-ray microdiffraction

Mechanical fatigue behavior of AL6XN stainless steel as a typical type of planar slip alloy was investigated by in situ neutron diffraction and synchrotron-based X-ray microdiffraction methods. Under cyclic loading at a high strain amplitude (+/- 0.8%), the fatigue damage originated mainly from the accumulation of statistical stored dislocations, as clearly evidenced from a continuous increase in diffraction peak width with increasing the number of load cycles. However, under cyclic loading at a low strain amplitude (+/- 0.3%), the density of statistical stored dislocations became saturated just after a hundred loading cycles and the fatigue damage was mainly dominated by the accumulation of persistent [Alders bands (PLBs) and the complex interactions among various PLBs as evidenced through X-ray microdiffraction measurements. It was further found that there exists obvious grain-orientation-dependent local damage in the low-strain-amplitude fatigued sample. In particular, fatigued grains orientated with [001] paralleling the loading direction are subjected to compressive stress and contain a large number of broad PLBs in boundaries arraying the edge dislocation pile-ups, which generate a large stress gradient leading to local plastic instability. As a result, the highly localized stress field at PLBs in the cyclically-deformed sample at a low strain amplitude may explain the obvious cyclic stress softening.

36 MATERIALS SCIENCE↗

Evaluating the accuracy of common γ-Al 2 O 3 structure models by selected area electron diffraction from high-quality crystalline γ-Al 2 O 3

Single crystal and textured polycrystalline γ-Al 2 O 3 thin films were synthesized by oxidation of NiAl(110) in air at 850 °C for 1 and 2 hours, respectively, and used to evaluate the accuracy of two spinel-based and two nonspinel models by comparison of selected-area electron diffraction (SAED). The lattice interplanar distances derived from the polycrystalline SAED pattern most closely matched the cubic spinel γ-Al 2 O 3 model. The single-crystal SAED spot pattern reflected symmetry consistent with both the cubic spinel and tetragonal nonspinel models, yet, the Al cation distribution better matched the cubic spinel model based on the relative intensities of diffraction spots. Our work indicates that the traditional cubic spinel model is a more accurate model of γ-Al 2 O 3 than the other models considered. Furthermore, the spinel-based monoclinic model is more accurate than the monoclinic nonspinel model. The understanding of the relative accuracy of the different models is key for simulating γ-Al 2 O 3 containing systems and is of general interest for the metal oxide and ceramic communities.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Quantification of grain rotation in bulk nanostructured copper via in situ heating white beam synchrotron X-ray diffraction

Grain rotation during microstructural relaxation under heating is conventionally studied extensively through transmission electron microscopy and simulations. However, there is a shortage in examining grain rotations at larger length and volume scales in bulk materials. It is critical to understand the thermal stability of bulk nanostructured metals, since those enhanced mechanical properties have been well recognized. Here, this study aimed to employ a white beam microdiffraction X-ray technique under in situ heating from 300 K to 1073 K at 12 K/min on a nanostructured copper processed by high-pressure torsion, yielding an initial grain size of ∼260 nm before the heating. Evaluation across a wide range of temperatures reveals transition temperatures associated with microstructural relaxation processes. By tracking separate Laue diffraction peaks stemming from individual grains, changes in their orientations can be estimated and quantified. This approach becomes particularly effective when the number of grains within the probed volume is reasonably small. At temperatures above 940 K, about 7.5 % of Cu grains are rotating at speeds of ∼2 × 10 –3 °/s. The radial direction of the disk specimen is found to be the preferred direction of grain rotation, with the rotation axis along the shear direction. Further analysis found no correlation between peak intensity and peak size, related to grain sizes and deviatoric strain, respectively, with rotation conditions or speed. These findings demonstrate that the diffraction technique utilizing white beam X-rays is a complementary and novel characterization tool for understanding microstructural evolution, especially in grain rotations, of bulk crystalline materials.

Grain orientation↗

Detonation diffraction in gases

We have experimentally investigated detonation diffraction out of a round tube into an unconfined half-space. The focus of our study is examining how the extent of detonation cellular instability influences the quantitative and qualitative features of diffraction. Detailed quantitative and qualitative measurements were obtained through simultaneous schlieren imaging, multiple-exposure chemiluminescence imaging, and planar laser-induced fluorescence imaging of OH molecules. Two types of stoichiometric mixtures, highly diluted H{sub 2}-O{sub 2}-Ar and H{sub 2}-N{sub 2}O, were studied in the sub-critical, critical and super-critical regime. These mixture types represent extreme cases in the classification of cellular instability with highly diluted H{sub 2}-O{sub 2}-Ar mixtures having very regular instability structures and H{sub 2}-N{sub 2}O having very irregular instability structures. The most striking differences between the mixtures occur in the sub-critical and critical regimes, for which the detonation fails to transition into the unconfined half-space. For the H{sub 2}-O{sub 2}-Ar mixture, the velocity on the center line was found to decay significantly slower than for the H{sub 2}-N{sub 2}O mixture. In case of the H{sub 2}-O{sub 2}-Ar mixture, it was evident from simultaneous schlieren-fluorescence images that the reaction front was coupled to the lead shock front up to 2.3 tube diameters from the exit plane. For the H{sub 2}-N{sub 2}O mixture, the reaction front velocity decreased to 60% of the corresponding Chapman-Jouguet value at 1.1 tube diameters from the tube exit plane. A geometric acoustic model showed that the observed differences in failure patterns are not caused by the differences in thermodynamic properties of the two mixtures but is linked to the larger effective activation energy and critical decay time in the H{sub 2}-N{sub 2}O mixture as compared to the H{sub 2}-O{sub 2}-Ar mixture. The re-initiation events appear similar for the two mixtures and are a consequence of local fluctuations at random locations within the region between the lead shock and decoupled reaction zone, resulting in strong transverse detonations sweeping through shocked but largely unreacted gas. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Pressure Effects on Boron Nitride Multi-Walled Nanotubes: An X-ray Diffraction Study

An X-ray diffraction study has been carried out on boron nitride multi-walled nanotubes up to 19.1 GPa. The fit to the unit cell volumes yields a zero pressure bulk modulus K0 = 34.9 {+-} 1 GPa and its pressure derivative K{prime}{sub 0} {+-} 0.3. The compression is highly anisotropic, with the intertube-axis being close to 19 times more compressible than the a-axis. At the highest pressure the diffraction peaks were present even though they were weak and broad, which is in contrast to previous high-pressure Raman results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-situ studies of large magnetostriction in DyCo 2 compound by synchrotron-based high-energy X-ray diffraction

Synchrotron-based high-energy X-ray diffraction is used to explore the physical origin of large magnetostriction in DyCo 2 , an RT 2 compound (R = rare earth, T = Co, Fe), by tracing the crystal structural change as a function of temperature and magnetic field. When the DyCo 2 compound is zero-field cooled down below the Curie temperature T C , the high-temperature cubic lattice is distorted into a tetragonal structure, associated with an expansion of unit cell volume. When a magnetic field is applied gradually from 0 to 6 T below T C , no changes in the peak positions for tetragonal (800) T and (008) T peaks are observed, whereas their relative peak intensities are gradually changed. The intensity changes generated during magnetic field increasing are reversed stepwise with decreasing the magnetic field. Our experimental results suggest that the large magnetostriction in DyCo 2 is caused by the crystallographic domain-switch mechanism (or rearrangement of tetragonal domains). In conclusion, the diffraction elastic strain is not detected under the field up to 6 T. The present investigations provide a fundamental understanding of the mechanisms of the large magnetostriction in RT 2 compounds with Laves phases.

36 MATERIALS SCIENCE↗

In situ observations of temperature- and pressure-induced phase transitions in TiH[subscript 2]: Angle-dispersive and synchrotron energy-dispersive X-ray diffraction studies

We investigated the behavior of the structure of titanium hydride (TiH{sub 2}), an important compound in hydrogen storage research, at elevated temperatures (0-120 C) and high pressures (1 bar-34 GPa). Temperature-induced changes of TiH{sub 2} as indicated in the alteration of the ambient X-ray demonstrated a cubic to tetragonal phase transition occurring at about 17 C. The main focus of this study was to identify any pressure-induced structural transformations, including possible phase transitions, in TiH{sub 2}. Synchrotron X-ray diffraction studies were carried out in situ (diamond anvil cell) in a compression sequence up to 34 GPa and in subsequent decompression to ambient pressure. The pressure evolution of the diffraction patterns revealed a cubic (Fm-3m) to tetragonal (I4/mmm) phase transition at 2.2 GPa. The high-pressure phase persisted up to 34 GPa. After decompression to ambient conditions the observed phase transition was completely reversible. A Birch-Murnaghan fit of the unit cell volume as a function of pressure yielded a zero-pressure bulk modulus K{sub 0} = 146(14) GPa, and its pressure derivative K{prime}{sub 0} = 6(1) for the high-pressure tetragonal phase of TiH{sub 2}.

08 HYDROGEN↗