Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Dissecting the contributions to non-photochemical quenching in a land plant under fluctuating light

Photosynthetic organisms have evolved multiple non-photochemical quenching (NPQ) processes, providing photoprotection by safely dissipating excess excitation energy. These processes involve various molecular players functioning on overlapping timescales from seconds to days, making it challenging to isolate and quantify their individual kinetics. In this study, we perform whole-leaf chlorophyll fluorescence lifetime and xanthophyll concentration measurements on wild-type and various newly characterized NPQ mutants of Nicotiana benthamiana, a vascular land plant. Based on these measurements, we construct a fluorescence lifetime-based quantitative kinetic model that disentangles individual photoprotection components and, when integrated additively, accurately predicts wild-type and mutant NPQ behaviors under various light-dark regimes. Additionally, the model quantifies the per-molecule quenching effectiveness of various xanthophylls and the contributions of six quenching components (qE V , qE A , qE Z , qE L , qZ, and qI) across different genotypes. It also suggests improved overall quenching efficiency at specific VDE:ZEP:PsbS overexpression stoichiometries, aligning with previous studies and supporting translational efforts to optimize photoprotection and enhance crop yields under dynamic light environments.

Lam, Lam [University of California, Berkeley, CA (↗

Seeded FEL Amplifier-Buncher in the 0.5-9 THz for Advanced Accelerators

Longitudinal modulation of a relativistic electron beam in the THz range is important for advanced laser- or beam-driven plasma accelerators operating in the 10{sup 16}-10{sup 18} cm{sup -3} plasma density range. We describe a single-pass FEL amplifier-buncher which is under construction at the UCLA Neptune laboratory. Microbunching on the 0.5-3 THz frequency scale is achieved during the process of a resonant FEL interaction between an electron beam and a THz seed pulse. A narrow-band, low-power THz seed source based on the frequency mixing of CO{sub 2} laser lines in a GaAs nonlinear crystal is built and fully characterized. The THz radiation pulse generated by this source will be guided through a hollow waveguide inside the planar FEL undulator driven by a regular photoinjector. By using a time-dependent FEL code GENESIS 1.3, we optimized the undulator parameters and analyzed the dynamics of the modulated electron beam. At present, the THz FEL microbuncher is being built and we update the status of the project.

43 PARTICLE ACCELERATORS↗

Dynamic neutron scattering on incoherent systems using efficient resonance spin flip techniques

We have performed numerical ray-tracing Monte-Carlo-simulations of incoherent dynamic neutron scattering experiments. We intend to optimize the efficiency of incoherent measurements depending on the fraction of neutrons scattered without and with spin flip at the sample. In addition to conventional spin echo, we have numerically and experimentally studied oscillating intensity techniques. The results point out the advantages of these different spin echo variants and are an important prerequisite for neutron resonance spin echo instruments like RESEDA (FRM II, Munich), to choose the most efficient technique depending on the scattering vector range and the properties of the sample system under study.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electric-field tunable spin diode FMR in patterned PMN-PT/NiFe structures

Dynamic properties of NiFe thin films on PMN-PT piezoelectric substrate are investigated using the spin-diode method. Ferromagnetic resonance (FMR) spectra of microstrips with varying width are measured as a function of magnetic field and frequency. The FMR frequency is shown to depend on the electric field applied across the substrate, which induces strain in the NiFe layer. Electric field tunability of up to 100 MHz per 1 kV/cm is achieved. An analytical model based on total energy minimization and the Landau-Lifshitz-Gilbert equation, taking into account the magnetostriction effect, is used to explain the measured dynamics. Based on this model, conditions for optimal electric-field tunable spin diode FMR in patterned NiFe/PMN-PT structures are derived.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Foil backlighter development at the OMEGA laser facility for extended x-ray absorption fine structure experiments

Extended x-ray absorption fine structure (EXAFS) measurements require a bright and continuous x-ray source and a detection system with high spectral resolution to capture the modulations of the absorption coefficient above the material absorption edge. When performing EXAFS measurements under laser-driven dynamic compression, it is hence critical to optimize the backlighter x-ray emission. In this study, a series of experiments has been conducted at the OMEGA laser facility to characterize titanium (Z = 22), iron (Z = 26), germanium (Z = 32), molybdenum (Z = 42), silver (Z = 47), and gold (Z = 79) foil backlighters irradiated with 3 kJ–12 kJ of laser energy. The spectra have been recorded using a dual crystal spectrometer (DCS), a two-channel transmission spectrometer covering 11 keV–45 keV and 19 keV–90 keV energy bands. The DCS has been calibrated so that the spectral intensities can be compared between different campaigns.

47 OTHER INSTRUMENTATION↗

Numerical analysis of radiation dynamics in a combined hohlraum in the X-ray opacity experiments on the 'Iskra-5' laser facility

We report the results of numerical analysis of radiation dynamics (laser absorption and X-ray generation) by using SNDLIRA code in a combined box used in the X-ray opacity measurements on the 'Iskra-5' facility (laser radiation wavelength, λ = 0.66 μm; laser pulse duration, τ{sub 0.5} ≈ 0.6 ns; and energy, 900 J). Combined boxes used in these experiments comprised three sections: two illuminators delivering laser radiation and a central diagnostic section with a test sample. We have proposed a scheme for step-by-step calculation of the heating dynamics of the sample under study in a three-section hohlraum. Two designs of a combined box, which differ in the ways the laser radiation is injected, are discussed. It is shown that the axial injection of the beams results in intense secondary laser irradiation of the illuminator edge which leads to its partial disruption and penetration of laser radiation into the central diagnostic section. In this case the sample under study is exposed to additional uncontrolled action of scattered laser radiation. Such an undesirable action may be avoided by using the lateral injection of the beams through four holes on the lateral side of the illuminators. For the latter case we have calculated the heating dynamics for the sample and found an optimal time delay for an X-ray probe pulse. (interaction of laser radiation with matter. laser plasma)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Material Plasma Exposure eXperiment High Heat Flux Microwave Absorber Design, Manufacture, and Articles Test

The Material Plasma Exposure eXperiment (MPEX) at Oak Ridge National Laboratory is in the final design phase. MPEX will be capable of exposing neutron-irradiated materials to plasmas for the study of plasma-material interaction. This facility will provide information about the complex effects of plasmas on materials and contribute to examining new materials that can withstand high heat fluxes and high ion fluences for future fusion devices. MPEX plasma is heated by 70-GHz or 105-GHz electron Bernstein wave/electron cyclotron heating (ECH), and the high-frequency microwaves are prone to scattering microwave power, which can have detrimental effects, especially on diagnostic components. A large portion of the injected ECH power is expected to be absorbed by plasma, but the remainder requires that microwave absorbers be placed immediately upstream and downstream of the ECH launcher to minimize stray microwaves leaving the ECH region. These microwaves can inadvertently heat components that cannot be shielded or otherwise protected. The microwave absorber design is based on an array of pyramid-shaped ceramic tiles brazed to a water-cooled explosion-bonded heat sink and a stainless steel plate to produce one tile module. Computational fluid dynamics and structural analyses were performed to optimize and validate the design. Multiple test coupons were produced to validate the process for brazing the two different tile materials to the Glidcop AL-15 baseplate. The articles were tested to evaluate the reliability and thermal performance through exposure to an electron beam with a heat flux of up to 1.5 MW/m2. Nondestructive testing was performed before and after testing to identify voids or separations that may have been introduced by the high heat flux. This paper discusses the details of high heat flux microwave absorber design, manufacturing details and associated challenges, and test results, demonstrating the effectiveness of the proposed design.

Hussain, Aftab↗

A PARALLEL MONTE CARLO CODE FOR SIMULATING COLLISIONAL N-BODY SYSTEMS

We present a new parallel code for computing the dynamical evolution of collisional N-body systems with up to N {approx} 10{sup 7} particles. Our code is based on the Henon Monte Carlo method for solving the Fokker-Planck equation, and makes assumptions of spherical symmetry and dynamical equilibrium. The principal algorithmic developments involve optimizing data structures and the introduction of a parallel random number generation scheme as well as a parallel sorting algorithm required to find nearest neighbors for interactions and to compute the gravitational potential. The new algorithms we introduce along with our choice of decomposition scheme minimize communication costs and ensure optimal distribution of data and workload among the processing units. Our implementation uses the Message Passing Interface library for communication, which makes it portable to many different supercomputing architectures. We validate the code by calculating the evolution of clusters with initial Plummer distribution functions up to core collapse with the number of stars, N, spanning three orders of magnitude from 10{sup 5} to 10{sup 7}. We find that our results are in good agreement with self-similar core-collapse solutions, and the core-collapse times generally agree with expectations from the literature. Also, we observe good total energy conservation, within {approx}< 0.04% throughout all simulations. We analyze the performance of the code, and demonstrate near-linear scaling of the runtime with the number of processors up to 64 processors for N = 10{sup 5}, 128 for N = 10{sup 6} and 256 for N = 10{sup 7}. The runtime reaches saturation with the addition of processors beyond these limits, which is a characteristic of the parallel sorting algorithm. The resulting maximum speedups we achieve are approximately 60 Multiplication-Sign , 100 Multiplication-Sign , and 220 Multiplication-Sign , respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Discrimination of binary coherent states using a homodyne detector and a photon number resolving detector

We investigate quantum measurement strategies capable of discriminating two coherent states probabilistically with significantly smaller error probabilities than can be obtained using nonprobabilistic state discrimination. We apply a postselection strategy to the measurement data of a homodyne detector as well as a photon number resolving detector in order to lower the error probability. We compare the two different receivers with an optimal intermediate measurement scheme where the error rate is minimized for a fixed rate of inconclusive results. The photon number resolving (PNR) receiver is experimentally demonstrated and compared to an experimental realization of a homodyne receiver with postselection. In the comparison, it becomes clear that the performance of the PNR receiver surpasses the performance of the homodyne receiver, which we prove to be optimal within any Gaussian operations and conditional dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrafast Molecular Frame Quantum Tomography

Here, we develop and experimentally demonstrate a methodology for a full molecular frame quantum tomography (MFQT) of dynamical polyatomic systems. We exemplify this approach through the complete characterization of an electronically nonadiabatic wave packet in ammonia (NH 3 ). The method exploits both energy and time-domain spectroscopic data, and yields the lab frame density matrix (LFDM) for the system, the elements of which are populations and coherences. The LFDM fully characterizes electronic and nuclear dynamics in the molecular frame, yielding the time- and orientation-angle dependent expectation values of any relevant operator. For example, the time-dependent molecular frame electronic probability density may be constructed, yielding information on electronic dynamics in the molecular frame. In NH 3 , we observe that electronic coherences are induced by nuclear dynamics which nonadiabatically drive electronic motions (charge migration) in the molecular frame. Here, the nuclear dynamics are rotational and it is nonadiabatic Coriolis coupling which drives the coherences. Interestingly, the nuclear-driven electronic coherence is preserved over longer timescales. In general, MFQT can help quantify entanglement between electronic and nuclear degrees of freedom, and provide new routes to the study of ultrafast molecular dynamics, charge migration, quantum information processing, and optimal control schemes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Adaptive PID Gain Scheduling Control for Hydropower Turbine Using Neural CDE and Stochastic Distribution Shaping

This paper introduces a gain-scheduling PID controller design strategy for hydroturbine frequency control mode. This scheme first uses real data to learn the nonlinear dynamics of the hydroturbine using neural controlled differential equations and then perturbs the obtained nonlinear system at different equilibrium points, based on which a static output feedback adaptive dynamic programming algorithm is then used to optimize the PID gains for each equilibrium point. Moreover, a continuous-time version of stochastic distribution control is proposed to further fine-tune the optimized PID gains. Finally, the controller is obtained by implementing linear interpolation between the optimized PID control gains. The simulation results show that the proposed gain-scheduling PID controller can control a larger range of operation points compared with the given fixed PID controller and the baseline method. Compared with the given fixed PID controller, the proposed gain-scheduling PID controller can regulate hydroturbine frequency against disturbances induced by power-load variation with over 50% less overshoot for some operation points.

13 HYDRO ENERGY↗

Implementing RapidArc into clinical routine: A comprehensive program from machine QA to TPS validation and patient QA

Purpose: With the increased commercial availability of intensity modulated arc therapy (IMAT) comes the need for comprehensive QA programs, covering the different aspects of this newly available technology. This manuscript proposes such a program for the RapidArc (RA) (Varian Medical Systems, Palo Alto) IMAT solution. Methods: The program was developed and tested out for a Millennium120 MLC on iX Clinacs and a HighDefinition MLC on a Novalis TX, using a variety of measurement equipment including Gafchromic film, 2D ion chamber arrays (Seven29 and StarCheck, PTW, Freiburg, Germany) with inclinometer and Octavius phantom, the Delta4 systam (ScandiDos, Uppsala, Sweden) and the portal imager (EPID). First, a number of complementary machine QA tests were developed to monitor the correct interplay between the accelerating/decelerating gantry, the variable dose rate and the MLC position, straining the delivery to the maximum allowed limits. Second, a systematic approach to the validation of the dose calculation for RA was adopted, starting with static gantry and RA specific static MLC shapes and gradually moving to dynamic gantry, dynamic MLC shapes. RA plans were then optimized on a series of artificial structures created within the homogeneous Octavius phantom and within a heterogeneous lung phantom. These served the double purpose of testing the behavior of the optimization algorithm (PRO) as well as the precision of the forward dose calculation. Finally, patient QA on a series of clinical cases was performed with different methods. In addition to the well established in-phantom QA, we evaluated the portal dosimetry solution within the Varian approach. Results: For routine machine QA, the ''Snooker Cue'' test on the EPID proved to be the most sensitive to overall problem detection. It is also the most practical one. The ''Twinkle'' and ''Sunrise'' tests were useful to obtain well differentiated information on the individual treatment delivery components. The AAA8.9 dose calculations showed excellent agreement with all corresponding measurements, except in areas where the 2.5 mm fixed fluence resolution was insufficient to accurately model the tongue and groove effect or the dose through nearly closed opposing leafs. Such cases benefited from the increased fluence resolution in AAA10.0. In the clinical RA fields, these effects were smeared out spatially and the impact of the fluence resolution was considerably less pronounced. The RA plans on the artificial structure sets demonstrated some interesting characteristics of the PRO8.9 optimizer, such as a sometimes unexpected dependence on the collimator rotation and a suboptimal coverage of targets within lung tissue. Although the portal dosimetry was successfully validated, we are reluctant to use it as a sole means of patient QA as long as no gantry angle information is embedded. Conclusions: The all-in validation program allows a systematic approach in monitoring the different levels of RA treatments. With the systematic approach comes a better understanding of both the capabilities and the limits of the used solution. The program can be useful for implementation, but also for the validation of major upgrades.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-486: Effect of the Normalized Prescription Isodose Line On Target Dose Deficiency in Lung SBRT Based On Monte Carlo Calculation

Purpose: To investigate the impact of normalized prescription isodose line on target dose deficiency calculated with Monte Carlo (MC) vs. pencil Beam (PB) in lung SBRT. RTOG guidelines recommend prescription lines between 60% and 90% for lung SBRT. How this affects the magnitude of MC-calculated target dose deficiency has never been studied. Methods: Under an IRB-approved protocol, four lung SBRT patients were replanned following RTOG0813 by a single physicist. For each patient, four alternative plans were generated based on PB calculation prescribing to 60–90% isodose lines, respectively. Each plan consisted of 360o coplanar dynamic conformal arcs with beam apertures manually optimized to achieve similar dose coverage and conformity for all plans of the same patient. Dose distribution was calculated with MC and compared to that with PB. PTV dose-volume endpoints were compared, including Dmin, D5, Dmean, D95, and Dmax. PTV V100 coverage, conformity index (CI), and heterogeneity index (HI) were also evaluated. Results: For all 16 plans, median (range) PTV V100 and CI were 99.7% (97.5–100%) and 1.27 (1.20–1.41), respectively. As expected, lower prescription line resulted in higher target dose heterogeneity, yielding median (range) HI of 1.26 (1.05–1.51) for all plans. Comparing MC to PB, median (range) D95, Dmean, D5 PTV dose deficiency were 18.9% (11.2–23.2%), 15.6% (10.0–22.7%), and 9.4%(5.5–13.6%) of the prescription dose, respectively. The Dmean, D5, and Dmax deficiency was found to monotonically increase with decreasing prescription line from 90% to 60%, while the Dmin deficiency monotonically decreased. D95 deficiency exhibited more complex trend, reaching the largest deficiency at 80% for all patients. Conclusion: Dependence on prescription isodose line was found for MC-calculated PTV dose deficiency of lung SBRT. When comparing reported MC dose deficiency values from different institutions, their individual selections of prescription line should be considered in addition to other factors affecting the deficiency magnitude.

60 APPLIED LIFE SCIENCES↗

MRG8 Random Number Generator Library (MRG8) v1.0

Pseudo random number generators (PRNGs) are crucial for nu- merous applications in HPC ranging from molecular dynamics to quantum chemistry, and hydrodynamics. Our optimized implementation generates the same random number sequence as the original well-characterized MRG8. MRG8-AVX512 achieves a substantial 69% improvement compared to Intel's MKL, and MRG8-GPU shows a maximum 3.36x speedup compared to NVIDIA's cuRAND library.

Shalf, JohnM.↗

PYSEQM

PYSEQM is a package for performing semi-empirical quantum mechanical (SEQM) simulations on molecular systems utilizing PyTorch. SEQM simulations determine molecular properties (energy, electron density, dipole moment, ect.) by solving an approximate Schrödinger equation for the motions of electrons in a molecule. The use of PyTorch provides three specific advantages. First, it allows the calculations to be offloaded to GPU accelerators, giving an order of magnitude increase in speed. Second, back propagation is used to get atomic forces (derivative of the total energy with respect to atomic position) at the same computational cost as the energy calculation itself. Finally, the use of PyTorch makes for a natural interface to modern machine learning methods, which can be used to adjust the semi-empirical parameters build into SEQM methods. Additionally, PYSEQM implements various other optimizations for performing quantum mechanics based molecular dynamics, including SP2 for rapid GPU based solution of the self-consistent field algorithm, and the extended Lagrangian method for rapid QM-MD.

Nebgen, Benjamin↗

WEC as a multiport

SAND2025-00555O WEC as a multiport is a software tool that simplifies the modeling and design of ocean wave energy converters (WECs) using a multi-port network framework in the frequency domain. Users can simulate the dynamic interactions between WECs and ocean waves, optimizing energy extraction and system performance. This tool supports the analysis of complex wave energy systems, aiding in the development of efficient and effective WEC designs. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Coe, Ryan↗

Titanium-Carbide Formation at Defective Curved Graphene-Titanium Interfaces

ABSTRACT Physical and chemical properties of graphene-metal interfaces have been largely examined with the objective of producing nanostructured carbon-based electronic devices. Although electronic properties are key to such devices, appropriate structural, thermal and mechanical properties are important for device performance as well. One of the most studied is the graphene-titanium (G-Ti) interface. Titanium is a low density, high strength versatile metal that can form alloys with desirable properties for applications ranging from aerospace to medicine. Small clusters and thin films of titanium deposited on graphene have also been examined. However, while some experiments show that thin films of titanium on graphene can be removed without damaging graphene hexagonal structure, others reported the formation of titanium-carbide (TiC) at G-Ti interfaces. In a previous work [ACS Appl. Mater. Interfaces, 2017, 9 (38), pp 33288-33297], we have shown that pristine G-Ti interfaces are resilient to large thermal fluctuations even when G-Ti structures lie on curved or kinked substrates. Here, using classical molecular dynamics with the third-generation Charge Optimized Many Body (COMB3) potential, we show that di-interstitial defective G-Ti structures on a copper substrate with a relatively large curvature kink, present signs of TiC formation. This result might help explain the different experimental results mentioned above.

catalysis (heterogeneous), defects, membrane, carb↗