Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Drift Chamber Alignment using Cosmic Rays

The Collider Detector at Fermilab (CDF) is a general-purpose experimental apparatus with an inner tracking detector for measuring charged particles, surrounded by a calorimeter for measurements of electromagnetic and hadronic showers, and a muon detector system. We present a technique for, and results of, a precise relative alignment of the drift chamber wires of the CDF tracker. This alignment has been an important component of the track momentum calibration, which is the basis for the charged-lepton calibration for the measurement of the W boson mass at CDF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and characterization of a novel toroidal split-ring resonator

The design and characterization of a novel toroidal split-ring resonator (SRR) are described in detail. In conventional cylindrical SRRs, there is a large magnetic flux within the bore of the resonator. However, there also exists a non-negligible magnetic flux in the free space surrounding the resonator. The energy losses associated with this radiated power diminish the resonator’s quality factor. In the toroidal SRR, on the other hand, the magnetic field lines are strongly confined within the bore of the resonator resulting in high intrinsic quality factors and stable resonance frequencies without requiring additional electromagnetic shielding. This paper describes the design and construction of a toroidal SRR as well as an experimental investigation of its cw response in the frequency-domain and its time-domain response to a rf pulse. Additionally, the dependence of the toroidal SRR’s resonant frequency and quality factor on the strength of inductive coupling to external circuits is investigated both theoretically and experimentally.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time airborne particle analyzer

An aerosol particle analyzer includes a laser ablation chamber, a gas-filled conduit, and a mass spectrometer. The laser ablation chamber can be operated at a low pressure, which can be from 0.1 mTorr to 30 mTorr. The ablated ions are transferred into a gas-filled conduit. The gas-filled conduit reduces the electrical charge and the speed of ablated ions as they collide and mix with buffer gases in the gas-filled conduit. Preferably, the gas filled-conduit includes an electromagnetic multipole structure that collimates the nascent ions into a beam, which is guided into the mass spectrometer. Because the gas-filled conduit allows storage of vast quantities of the ions from the ablated particles, the ions from a single ablated particle can be analyzed multiple times and by a variety of techniques to supply statistically meaningful analysis of composition and isotope ratios.

47 OTHER INSTRUMENTATION↗

Methods of analyzing composition of aerosol particles

An aerosol particle analyzer includes a laser ablation chamber, a gas-filled conduit, and a mass spectrometer. The laser ablation chamber can be operated at a low pressure, which can be from 0.1 mTorr to 30 mTorr. The ablated ions are transferred into a gas-filled conduit. The gas-filled conduit reduces the electrical charge and the speed of ablated ions as they collide and mix with buffer gases in the gas-filled conduit. Preferably, the gas filled-conduit includes an electromagnetic multipole structure that collimates the nascent ions into a beam, which is guided into the mass spectrometer. Because the gas-filled conduit allows storage of vast quantities of the ions from the ablated particles, the ions from a single ablated particle can be analyzed multiple times and by a variety of techniques to supply statistically meaningful analysis of composition and isotope ratios.

47 OTHER INSTRUMENTATION↗

Measurement of Z{gamma} production in pp collisions at {radical}(s)=1.96 TeV

The production rate and kinematics of photons produced in association with Z bosons are studied using 2 fb{sup -1} of pp collision data collected at the Collider Detector at Fermilab. The cross section for pp{yields}l{sup +}l{sup -}{gamma}{sup +}X (where the leptons l are either muons or electrons with dilepton mass M{sub ll}>40 GeV/c{sup 2}, and where the photon has transverse energy E{sub T}{sup {gamma}}>7 GeV and is well separated from the leptons) is 4.6{+-}0.2(stat){+-}0.3(syst){+-}0.3(lum) pb, which is consistent with standard model expectations. We use the photon E{sub T} distribution from Z{gamma} events where the Z has decayed to {mu}{sup +}{mu}{sup -}, e{sup +}e{sup -}, or {nu}{nu} to set limits on anomalous (non standard model) trilinear couplings between photons and Z bosons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New capabilities in high-resolution neutron Larmor diffraction at ORNL

Using superconducting magnetic Wollaston prisms, high-resolution neutron Larmor diffraction has been implemented at the High-Flux Isotope Reactor of Oak Ridge National Laboratory (ORNL), Tennesse, USA. This technique allows the inverse relationship between the achievable diffraction resolution and the usable neutron flux to be overcome. Instead of employing physically tilted radio-frequency spin flippers, the method uses magnetic Wollaston prisms which are electromagnetically tuned by changing the field configurations in the device. As implemented, this method can be used to measure lattice-spacing changes induced, for example, by thermal expansion or strain with a resolution of Δd/d ≃ 10 –6 , and the splitting of sharp Bragg peaks with a resolution of Δd/d = 3 × 10 –4 . The resolution for discerning a change in the profile of a Bragg peak is Δd/d < 10 –5 . This is a remarkable degree of precision for a neutron diffractometer as compact as the one used in this implementation. Higher precision could be obtained by implementing this technique in an instrument with a larger footprint. In conclusion, the availability of this technique will provide an alternative when standard neutron diffraction methods fail and will greatly benefit the scientific communities that require high-resolution diffraction measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Search for WIMP Dark Matter Using the First Five-Tower Run of the Cryogenic Dark Matter Search

In recent decades astronomers and physicists have accumulated a vast array of evidence that the bulk of the universe's matter is in some non-baryonic form that remains undetected by electromagnetic means. This \dark matter" resides in diuse halos surrounding galaxies and other cosmic structures. Particle theorists have proposed a wide array of candidates for its nature. One particularly promising class of candidates are Weakly Interacting Massive Particles (WIMPs): quanta with masses of order 100 GeV/c2 and interactions characteristic of the weak nuclear force. The Cryogenic Dark Matter Search (CDMS) experiment seeks to directly detect the rare elastic interactions of galactic WIMPs with terrestrial nuclei. To this end, CDMS operates an array of crystalline Ge and Si particle detectors in Soudan Underground Laboratory in northern Minnesota. These crystals are operated at millikelvin temperatures and instrumented to measure the ionization and athermal phonons generated by each particle interaction. This combination provides a powerful two-fold discrimination against the interactions of particles generated by radioactive decay and cosmogenic showers. This dissertation describes the commissioning, analysis, and results of the rst WIMP-search data runs of the CDMS experiment with its full complement of 5 \Towers" of detectors. These data represent a substantial increase in target mass and exposure over previous CDMS results. The results of this work place the most stringent limits yet set upon the WIMP-nucleon spin-independent cross section for WIMP masses above 44 GeV/c2 , as well as setting competitive limits on spin-dependent WIMP-nucleon interactions. This work also outlines the larger context of this and other probes of the WIMP theory of dark matter, as well as some current development eorts toward a larger cryogenic experiment.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron cyclotron resonance ion source plasma characterization by X-ray spectroscopy and X-ray imaging

An experimental campaign aiming to investigate electron cyclotron resonance (ECR) plasma X-ray emission has been recently carried out at the ECRISs—Electron Cyclotron Resonance Ion Sources laboratory of Atomki based on a collaboration between the Debrecen and Catania ECR teams. In a first series, the X-ray spectroscopy was performed through silicon drift detectors and high purity germanium detectors, characterizing the volumetric plasma emission. The on-purpose developed collimation system was suitable for direct plasma density evaluation, performed “on-line” during beam extraction and charge state distribution characterization. A campaign for correlating the plasma density and temperature with the output charge states and the beam intensity for different pumping wave frequencies, different magnetic field profiles, and single-gas/gas-mixing configurations was carried out. The results reveal a surprisingly very good agreement between warm-electron density fluctuations, output beam currents, and the calculated electromagnetic modal density of the plasma chamber. A charge-coupled device camera coupled to a small pin-hole allowing X-ray imaging was installed and numerous X-ray photos were taken in order to study the peculiarities of the ECRIS plasma structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of in-medium {omega}-meson properties in Ap and pA collisions

The possibility to investigate the in-medium properties of the vector {omega} mesons at normal nuclear density is considered. The folding model and simulations with the RQMD generator have been used for studying of the {omega}-resonance production in Ap and pA reactions and its {omega} {sup {yields} {pi}0{gamma}} {sup {yields}}3{gamma} decay. We show that measurements in the inverse Ap kinematics is an effective way to get information about the {omega}-meson mass modification especially in not yet explored range of small meson momenta relative to the projectile nuclei where the strength of the effect is expected to be most strong. The traditional pA kinematics appears to be more preferable for the investigation of the in-medium {omega}-meson width. Using of compact electromagnetic calorimeter provides the possibility to collect large statistics and study the momentum dependencies of both the {omega}-meson mass and width at the density of normal nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ASTROSAT CZT IMAGER OBSERVATIONS OF GRB 151006A: TIMING, SPECTROSCOPY, AND POLARIZATION STUDY

AstroSat is a multi-wavelength satellite launched on 2015 September 28. The CZT Imager of AstroSat on its very first day of operation detected a long duration gamma-ray burst (GRB), namely GRB 151006A. Using the off-axis imaging and spectral response of the instrument, we demonstrate that the CZT Imager can localize this GRB correctly to about a few degrees, and it can provide, in conjunction with Swift , spectral parameters similar to those obtained from Fermi /GBM. Hence, the CZT Imager would be a useful addition to the currently operating GRB instruments ( Swift and Fermi ). Specifically, we argue that the CZT Imager will be most useful for the short hard GRBs by providing localization for those detected by Fermi and spectral information for those detected only by Swift . We also provide preliminary results on a new exciting capability of this instrument: the CZT Imager is able to identify Compton scattered events thereby providing polarization information for bright GRBs. GRB 151006A, in spite of being relatively faint, shows hints of a polarization signal at 100–300 keV (though at a low significance level). We point out that the CZT Imager should provide significant time resolved polarization measurements for GRBs that have fluence three times higher than that of GRB 151006A. We estimate that the number of such bright GRBs detectable by the CZT Imager is five to six per year. The CZT Imager can also act as a good hard X-ray monitoring device for possible electromagnetic counterparts of gravitational wave events.

79 ASTRONOMY AND ASTROPHYSICS↗

FORBIDDEN AND INTERCOMBINATION LINES OF RR TELESCOPII: WAVELENGTH MEASUREMENTS AND ENERGY LEVELS

Ultraviolet and visible spectra of the symbiotic nova RR Telescopii are used to derive reference wavelengths for many forbidden and intercombination transitions of ions +1 to +6 of elements C, N, O, Ne, Na, Mg, Al, Si, P, S, Cl, Ar, K, and Ca. The wavelengths are then used to determine new energy values for the levels within the ions' ground configurations or first excited configuration. The spectra were recorded by the Space Telescope Imaging Spectrograph of the Hubble Space Telescope and the Ultraviolet Echelle Spectrograph of the European Southern Observatory in 2000 and 1999, respectively, and cover 1140-6915 A. Particular care was taken to assess the accuracy of the wavelength scale between the two instruments. An investigation of the profiles of the emission lines reveals that the nebula consists of at least two plasma components at different velocities. The components have different densities, and a simple model of the lines' emissions demonstrates that most of the lines principally arise from the high density component. Only these lines were used for the wavelength study.

79 ASTRONOMY AND ASTROPHYSICS↗

Technical Basis for Electromagnetic Compatibility Regulatory Guidance Update

The objective of this report is to serve as the technical basis document for the next, planned revision of this RG that highlights and provides the rationale for the recommended changes. The structure of this document follows and summarizes the several assessment activities undertaken during the course of this project to evaluate new and updated electromagnetic compatibility (EMC) standards, testing methods and limits, and relevant technology developments being incorporated into plant activities that may have EMI/RFI implications, as well as other specific issues, including impacts of electrostatic discharge (ESD) on safety equipment and impacts on increased usage of wireless devices in nuclear power plants.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Developing time-resolved x-ray diffraction diagnostics at the National Ignition Facility (invited)

As part of a program to measure phase transition timescales in materials under dynamic compression, we have designed new x-ray imaging diagnostics to record multiple x-ray diffraction measurements during a single laser-driven experiment. Our design places several ns-gated hybrid CMOS (hCMOS) sensors within a few cm of a laser-driven target. The sensors must be protected from an extremely harsh environment, including debris, electromagnetic pulses, and unconverted laser light. Another key challenge is reducing the x-ray background relative to the faint diffraction signal. Building on the success of our predecessor (Target Diffraction In Situ), we implemented a staged approach to platform development. First, we built a demonstration diagnostic (Gated Diffraction Development Diagnostic) with two hCMOS sensors to confirm we could adequately protect them from the harsh environment and also acquire acceptable diffraction data. This allowed the team to quickly assess the risks and address the most significant challenges. Here, we also collected scientifically useful data during development. Leveraging what we learned, we recently developed a much more ambitious instrument (Flexible Imaging Diffraction Diagnostic for Laser Experiments) that can field up to eight hCMOS sensors in a flexible geometry and participate in back-to-back shots at the National Ignition Facility (NIF). The design also allows for future iterations, such as faster hCMOS sensors and an embedded x-ray streak camera. The enhanced capabilities of the new instrument required a much more complex design, and the unexpected issues encountered on the first few shots at NIF remind us that complexity has consequences. Our progress in addressing these challenges is described herein, as is our current focus on improving data quality by reducing x-ray background and quantifying the uncertainties of our diffraction measurements.

36 MATERIALS SCIENCE↗

Quantum Sensing and its Potential for Nuclear Safeguards

Quantum sensing has the potential to provide ultrasensitive measurements of physical phenomenon. Unlike quantum computing, quantum sensing is available now, though in general at research laboratories. A notable commercially-available quantum sensing device is the ubiquitous Superconducting Quantum Interference Device (SQUID), which can measure faint magnetic fields such as found in the human brain. Quantum sensing is used for direct measurement of environmental phenomenon, such as electromagnetic fields and accelerations, which then are used for certain applications. For example, quantum sensing of accelerations is useful for Position, Navigation, and Timing (PNT) applications. It is not clear, however, how quantum sensing can be useful for nuclear safeguards. This report provides first a background in quantum sensing, followed by a survey of potential safeguards utilizations of quantum sensing. Several potential safeguards applications are identified and explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OBSERVATIONAL SELECTION EFFECTS WITH GROUND-BASED GRAVITATIONAL WAVE DETECTORS

Ground-based interferometers are not perfect all-sky instruments, and it is important to account for their behavior when considering the distribution of detected events. In particular, the LIGO detectors are most sensitive to sources above North America and the Indian Ocean, and as the Earth rotates, the sensitive regions are swept across the sky. However, because the detectors do not acquire data uniformly over time, there is a net bias on detectable sources’ right ascensions. Both LIGO detectors preferentially collect data during their local night; it is more than twice as likely to be local midnight than noon when both detectors are operating. We discuss these selection effects and how they impact LIGO’s observations and electromagnetic (EM) follow-up. Beyond galactic foregrounds associated with seasonal variations, we find that equatorial observatories can access over 80% of the localization probability, while mid-latitudes will access closer to 70%. Facilities located near the two LIGO sites can observe sources closer to their zenith than their analogs in the south, but the average observation will still be no closer than 44° from zenith. We also find that observatories in Africa or the South Atlantic will wait systematically longer before they can begin observing compared to the rest of the world; though, there is a preference for longitudes near the LIGOs. These effects, along with knowledge of the LIGO antenna pattern, can inform EM follow-up activities and optimization, including the possibility of directing observations even before gravitational-wave events occur.

79 ASTRONOMY AND ASTROPHYSICS↗

Very high Momentum Particle Identification detector for ALICE at the LHC

The anomalies observed at RHIC for the baryon-meson ratios have prompted a number of theoretical works on the nature of the hadrochemistry in the hadronisation stage of the pp collisions and in the evolution of the dense system formed in heavy ion collisions. Although the predictions differ in the theoretical approach, generally a substantial increase in the baryon production is predicted in the range 10-30 GeV/c. This raises the problem of baryon identification to much higher momenta than originally planned in the LHC experiments. After a review of the present status of theoretical predictions we will present the possibilities of a gas ring imaging Cherenkov detector of limited acceptance which would be able to identify track-by-track protons until 26 GeV/c. The physics capabilities of such a detector in conjunction with the ALICE experiment will be contemplated as well as the triggering options to enrich the sample of interesting events with a dedicated trigger or/and using the ALICE Electromagnetic Calorimeter. The use of the electromagnetic calorimeter opens interesting possibility to distinguish quark and gluon jets in gamma--jet events and subsequently the study of the probability of fragmentation in proton, kaon and pion or triggering on jets in the EMCAL. Such a detector would be identify pions until 14 GeV/c kaons from 9 till 14 GeV/c and protons from 18 till 24/GeV/c in a positive way and by absence of signal from 9-18 GeV/c.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LIFTING THE DUSTY VEIL WITH NEAR- AND MID-INFRARED PHOTOMETRY. I. DESCRIPTION AND APPLICATIONS OF THE RAYLEIGH-JEANS COLOR EXCESS METHOD

The Milky Way (MW) remains a primary laboratory for understanding the structure and evolution of spiral galaxies, but typically we are denied clear views of MW stellar populations at low Galactic latitudes because of extinction by interstellar dust. However, the combination of Two Micron All-Sky Survey (2MASS) near-infrared (NIR) and Spitzer-IRAC mid-infrared (MIR) photometry enables a powerful method for determining the line-of-sight reddening to any star: the sampled wavelengths lie in the Rayleigh-Jeans part of the spectral energy distribution of most stars, where, to first order, all stars have essentially the same intrinsic color. Thus, changes in stellar NIR-MIR colors due to interstellar reddening are readily apparent, and (under an assumed extinction law) the observed colors and magnitudes of stars can be easily and accurately restored to their intrinsic values, greatly increasing their usefulness for Galactic structure studies. In this paper, we explore this 'Rayleigh-Jeans Color Excess' (RJCE) method and demonstrate that use of even a simple variant of the RJCE method based on a single reference color, (H -[4.5{mu}]), can rather accurately remove dust effects from previously uninterpretable 2MASS color-magnitude diagrams of stars in fields along the heavily reddened Galactic midplane, with results far superior to those derived from application of other dereddening methods. We also show that 'total' Galactic midplane extinction looks rather different from that predicted using 100{mu} emission maps from the IRAS/ISSA and COBE/DIRBE instruments as presented by Schlegel et al. Instead, the Galactic midplane extinction strongly resembles the distribution of {sup 13}CO (J = 1{yields}0) emission. Future papers will focus on refining the RJCE method and applying the technique to understand better not only dust and its distribution but also the distribution of stars intermixed with the dust in the low-latitude Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

The CMS barrel calorimeter response to particle beams from 2-GeV/c to 350-GeV/c

The response of the CMS barrel calorimeter (electromagnetic plus hadronic) to hadrons, electrons and muons over a wide momentum range from 2 to 350 GeV/c has been measured. To our knowledge, this is the widest range of momenta in which any calorimeter system has been studied. These tests, carried out at the H2 beam-line at CERN, provide a wealth of information, especially at low energies. The analysis of the differences in calorimeter response to charged pions, kaons, protons and antiprotons and a detailed discussion of the underlying phenomena are presented. We also show techniques that apply corrections to the signals from the considerably different electromagnetic (EB) and hadronic (HB) barrel calorimeters in reconstructing the energies of hadrons. Above 5 GeV/c, these corrections improve the energy resolution of the combined system where the stochastic term equals 84.7 {+-} 1.6% and the constant term is 7.4 {+-} 0.8%. The corrected mean response remains constant within 1.3% rms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗