Search NASASearch

SEARCH · Search NASA

Results for “High-performance Computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,849 records · Page 70

Multi-modal dynamic radiography using short-pulse laser-generated probe beams

Radiography is an important tool for the interrogation of dynamic experiments in the fields of dynamic properties of materials, and in condensed matter, high explosive, and high-energy-density physics. Multi-modal radiography advances the hypothesis that combining the information delivered by multiple radiographic modalities can lead to more constrained (improved) “reconstruction” of the scene than can be obtained from a single probe. We identify four modalities: multi-probe, time sequence, multi-view, and multi-messenger. Multi-probe radiography is a promising candidate for a next-generation dynamic radiographic facility. High-energy X-rays are the most frequently used probe for dynamic radiography, although recent developments show the utility of proton (pRad), electron (eRad), and neutron probe beams. Because each probing species interacts with material in the radiographic scene through quantitatively different mechanisms, each returns independent information about the scene, which can add extra constraints to the reconstruction process. How to conduct detailed, quantitative “co-analysis” of multiple data streams remains an area of active research. Multi-beam, short-pulse, laser-generated probes offer sufficient dose, an appropriate spectrum, and appropriate spatio-temporal resolution to produce high-quality dynamic radiographs. This paper reports on technology development to advance the state of the art of multi-modal/multi-probe radiography and the pursuit of both deterministic and inferential (AI/ML assisted) co-analysis methodologies to produce more constrained reconstructions from multi-modal data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Simulating the Lunar Thermal Environment for the Surface-Deployed LEMS Artemis III TVAC Test

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. Presented is the system thermal vacuum test plan and configuration to validate the thermal control system performance in a flight-like environment. The test will measure the nighttime heat leaks for the bus and 18 seismometers to ensure lunar night survival and operability.

Thermal

Simulating the Lunar Thermal Environment for the Surface-Deployed LEMS Artemis III TVAC Test

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. Presented is the system thermal vacuum test plan and configuration to validate the thermal control system performance in a flight-like environment. The test will measure the nighttime heat leaks for the bus and 18 seismometers to ensure lunar night survival and operability.

Thermal

Simulating the Lunar Thermal Environment for the Surface-Deployed LEMS Artemis III TVAC Test

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. Presented is the system thermal vacuum test plan and configuration to validate the thermal control system performance in a flight-like environment. The test will measure the nighttime heat leaks for the bus and 18 seismometers to ensure lunar night survival and operability.

TVAC

Engineering and Abuse Testing of Panasonic Lithium-Ion Battery and Cells

This viewgraph presentation reviews the performance testing of Lithium Ion batteries and cells under different conditions of charge and discharge. The tests show that the 0.5 C rate of charge and discharge might be the ideal condition for long term cycling. It reviews the issues of overcharge and overdischarge of the cells. The cells and the battery have adequate protection under both conditions to prevent any catastrophic occurrences. Temperatures above 150 C are required to vent the cells or cause a thermal runaway, Since this situation is non-credible in the cabin of the Space Shuffle or ISS this should not pose a problem. The presentation includes graphs and charts showing the charge and discharge capacities of the battery and also the current and voltage profiles. A view of a circuit board which contains the controlling mechanism for the battery is also shown.

Jeevarajan, Judith A.

230Th/234U radiochronometry for uranium materials by alpha spectrometry for nuclear forensics analysis

We have developed an alpha spectrometry method for 230Th/234U radiochronometry to determine the model separation age for uranium materials. This method offers an alternative to the more commonly used, but significantly more resource intensive multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) while providing similar accuracy and precision. The development included radiochemical separation of uranium and thorium, calibration of the 232U tracer and the alpha spectrometry measurement. The method was validated by analyzing a certified reference material, CRM 125-A, which is a uranium oxide pellet assay, isotopic, and radiochronometric standard. The results were compared to those obtained by our routine MC-ICP-MS 230Th/234U radiochronometry analysis method to assess the performance parameters for alpha spectrometry compared to the state-of-the-art technique.

Macsik, Zsuzsanna [Los Alamos National Laboratory

CLDP/ISS Glovebox Technical Interchange Meeting

This presentation is designed to provide a high-level overview of the Microgravity Science Glovebox (MSG) and the Life Sciences Glovebox (LSG) facilities onboard the International Space Station. In addition, it provides metrics and lessons-learned information intended for the Commercial Low-Earth Orbit Development Program (CLDP) Partners.

glovebox

Electric Propulsion for Manned Missions

Electric propulsion is of interest for manned interplanetary missions, primarily because it offers the potential of delivering and returning relatively large payload fractions from the planets. This can be achieved because of the high specific impulse obtainable when the propellant is accelerated by electrical means rather than thermally, as in chemical and nuclear rockets.

Robert J Denington

Development and Evaluation of a Cost-Effective Behind-the-Meter Synchronized Measurement Unit for Enhanced Grid Integration

This paper presents the development of the Inverter Based Resource Monitor (IBRM), an innovative behind-the-meter synchronized measurement unit (SMU) tailored for integration with inverter-based resources (IBRs). The IBRM distinguishes itself as a highly accurate and cost-effective SMU, offering facile deployment and connectivity to IBRs. It is equipped to conduct real-time voltage and current waveform analyses, serving as a phasor measurement unit (PMU) with exceptionally rapid synchrophasor transmission capabilities. The device incorporates a cutting-edge dual-core architecture designed to minimize sampling delays inherent to its microprocessor, thereby enhancing the precision of synchronized waveform measurements. Moreover, the IBRM is adept at recording high-fidelity waveform data, capturing nuances such as waveform distortions, high-order harmonics, and wide-band oscillations prevalent in power grids with substantial IBR presence. A prototype of the IBRM has been constructed and subjected to rigorous testing to assess its functional capabilities and measurement precision, utilizing both idealized signal generators and a real-world off-grid inverter setup as benchmarks.

Wu, Ori [ORNL] (ORCID:0000000326723410)

Workshop on Advances in NASA-Relevant, Minimally Invasive Instrumentation

The purpose of this meeting is to highlight those advances in instrumentation and methodology that can be applied to the medical problems that will be encountered as the duration of manned space missions is extended. Information on work that is presently being done by NASA as well as other approaches in which NASA is not participating will be exchanged. The NASA-sponsored efforts that will be discussed are part of the overall Space Medicine Program that has been undertaken by NASA to address the medical problems of manned spaceflight. These problems include those that have been observed in the past as well as those which are anticipated as missions become longer, traverse different orbits, or are in any way different. This conference is arranged in order to address the types of instrumentation that might be used in several major medical problem areas. Instrumentation that will help in the cardiovascular, musculoskeletal, and psychological areas, among others will be presented. Interest lies in identifying instrumentation which will help in learning more about ourselves through experiments performed directly on humans. Great emphasis is placed on non-invasive approaches, although every substantial program basic to animal research will be needed in the foreseeable future. Space Medicine is a rather small affair in what is primarily an engineering organization. Space Medicine is conducted throughout NASA by a very small skeleton staff at the headquarters office in Washington and by our various field centers. These centers include the Johnson Space Center in Houston, Texas, the Ames Research Center in Moffett Field, California, the Jet Propulsion Laboratory in Pasadena, California, the Kennedy Space Center in Florida, and the Langley Research Center in Hampton, Virginia. Throughout these various centers, work is conducted in-house by NASA's own staff scientists, physicians, and engineers. In addition, various universities, industries, and other government laboratories perform research that cannot be effectively carried out in-house. At the moment, approximately 50% of the work is performed in-house and 50% is extramural. The area of bioinstrumentation pervades every one of our problem areas. In each, equipment or procedures are being developed that will allow more clinical work to be done in a ground-based or spacecraft setting. Although work of this kind goes on throughout the NASA organization and through its grants and contracts in the community at large, the major thrust of it is concentrated at the Jet Propulsion Laboratory which plays a lead role in this type of research and acts as the lead center in bioinstrumentation for NASA. It is recognized that there is much additional research being pursued in this area which would be potentially valuable to NASA and could, with some stimulation from, be made more applicable to NASA's needs. It is hoped, therefore, that the proceedings of this conference will be used as the basis for developing research strategies to be used as a road map to point the way in which NASA's own sponsored program should proceed over the course of the next three years. Additionally, it is hoped that the conference will highlight additional areas in which NASA should be involved either in-house or through the sponsorship of non-NASA scientists. NASA would also like to get an idea of which areas should be emphasized or perhaps de-emphasized among those that it is currently pursuing. In considering these questions, the discussion should concern itself not so much with whether a particular procedure or piece of equipment would work in a spacecraft, but rather, with whether the procedures that are advocated are at the state-of-the-art or beyond the state-of-the-art and whether they hold promise of giving additional insight into the problems to be confronted as humans venture into space for longer and longer periods of time.

Source record

Space Station battery system design and development

The Space Station Electric Power System will rely on nickel-hydrogen batteries in its photovoltaic power subsystem for energy storage to support eclipse and contingency operations. These 81-Ah batteries will be designed for a 5-year life capability and are configured as orbital replaceable units (ORUs), permitting replacement of worn-out batteries over the anticipated 30-year Station life. This paper describes the baseline design and the development plans for the battery assemblies, the battery ORUs and the battery system. Key elements reviewed are the cells, mechanical and thermal design of the assembly, the ORU approach and interfaces, and the electrical design of the battery system. The anticipated operational approach is discussed, covering expected performance as well as the processor-controlled charge management and discharge load allocation techniques. Development plans cover verification of materials, cells, assemblies and ORUs, as well as system-level test and analyses.

Haas, R. J.

Raman and Infrared Spectroscopy of Yttrium Aluminum Borate Glasses and Glass-ceramics

Raman spectra of glasses and glass-ceramics in the Y2O3-Al2O3-B2O3 system are reported. Glasses with B2O3 contents ranging from 40 to 60 mole percent were prepared by melting 20 g of the appropriate oxide or carbonate powders in alumina crucibles at 1400 C for 45 minutes. Subsequent heat treatments of the glasses at temperatures ranging from 600 to 800 C were performed in order to induce nucleation and crystallization. It was found that Na2CO3 added to the melt served as a nucleating agent and resulted in uniform bulk crystallization. The Raman spectra of the glasses are interpreted primarily in terms of vibrations of boron - oxygen structural groups. Comparison of the Raman spectra of the glass-ceramic samples with spectra of aluminate and borate crystalline materials reveal that these glasses crystallize primarily as yttrium aluminum borate, YAl3(BO3)4.

J Bradley

Scintillator Library

This website provides measured scintillation properties of many inorganic and organic materials and citations to published papers in which the original measurements were reported. It is intended for two main uses: a web-accessible reference to useful scintillation detector materials and properties; an aid in developing fundamental theories or empirical relations between basic material properties and scintillation performance. To this end, both strong and weak scintillators have been included as well as those where sensitive measurements have not detected any scintillation emissions.

Shook, L. [University of California, Berkeley, CA

Breaking the Energy Barrier of Heavy Metal Ion Diffusion in Micropores with Mesoporous 3D Graphene for Fast and Efficient Cu2+ Removal

Efficient removal of heavy metals from water critically depends not only on adsorption capacity but also on ion diffusion kinetics and the associated energy barriers. In conventional carbon adsorbents, severe diffusion confinement within micropores restricts ion transport, resulting in sluggish adsorption kinetics and large apparent activation energies despite high specific surface areas. Here, we demonstrate that this fundamental limitation is overcome by engineering meso/macroporous architectures in the 3D graphene materials synthesized via our discovered alkali-metal reactions with\\\\r\\\\n2\\\\r\\\\nCO. The unique 3D graphene materials possess defect-rich graphene frameworks with interconnected meso/macroporous networks, exhibiting simultaneously high surface area and greatly enhanced meso/macropore volume that enable efficient access to adsorption sites. As a result, the Cu2+ adsorption on 3D graphene proceeds with very low activation energies (4.98 kJ mol–1), which is almost 4 times smaller than on activated carbon (23.1 kJ mol–1). This finding offers a promising platform for efficient and sustainable water purification.

25 ENERGY STORAGE

Development of Electrolytes under Lean Condition in Lithium–Sulfur Batteries

Lithium–sulfur (Li–S) batteries stand out as one of the promising candidates for next-generation electrochemical energy storage technologies. A key requirement to realize high-specific-energy Li–S batteries is to implement low amount of electrolyte, often characterized by the electrolyte/sulfur (E/S) ratio. Low E/S ratio aggravates the known challenges for Li–S batteries and introduces new ones originated from the high concentration of polysulfides in limited electrolyte reservoir. Here, in this review, the connections between the fundamental properties of electrolytes and the electrochemical/chemical reactions in Li–S batteries under lean electrolyte condition are elucidated. The emphasis is on how the solvating properties of the electrolyte affect the fate of polysulfides. Built upon the mechanistic analysis, different strategies to design lean electrolytes to improve the overall process of Li–S reactions and Li anode protection are discussed.

25 ENERGY STORAGE

Socio-Techno-Economic Feasibility of Deep Geothermal with EGS for Residential District Heating in the Northeastern United States

In this paper, we present socio-techno-economic simulation results for enhanced geothermal system (EGS) district heating systems in the northeastern United States. We applied the geospatial Distributed Geothermal Market Demand (dGeo) tool coupled with GEOPHIRES to evaluate the feasibility of geothermal deep direct-use, utilizing EGS reservoirs for providing residential heating with district heating systems. The results were combined with JEDI results to assess social impacts. Simulation results assuming doublet EGS reservoirs with target production temperature of 80 degrees C and newly constructed district heating systems indicate a wide range in system levelized cost of heat (LCOH) values ranging from ~$15/MMBtu to over $1,000/MMBtu, with most the attractive regions urban areas with high total thermal demand and high thermal demand density. We estimate about 60 GWth in potential installed capacity with LCOH values under $50/MMBtu and 100 GWth in potential capacity with LCOH values under $100/MMBtu, respectively.

15 GEOTHERMAL ENERGY

Fabrication of Large-Area Metal-on-Carbon Catalytic Condensers for Programmable Catalysis

Catalytic condensers stabilize charge on either side of a high-k dielectric film to modulate the electronic states of a catalytic layer for the electronic control of surface reactions. Here, carbon sputtering provided for fast, large-scale fabrication of metal–carbon catalytic condensers required for industrial application. Carbon films were sputtered on HfO 2 dielectric/p-type Si with different thicknesses (1, 3, 6, and 10 nm), and the enhancement of conductance and capacitance of carbon films was observed upon increasing the carbon thickness following thermal treatment at 400 °C. After Pt deposition on the carbon films, the Pt catalytic condenser exhibited a high capacitance of ∼210 nF/cm 2 that was maintained at a frequency ∼1000 Hz, satisfying the requirement for a dynamic catalyst to implement catalytic resonance. Temperature-programmed desorption of carbon monoxide yielded CO desorption peaks that shifted in temperature with the varying potential applied to the condenser (−6 or +6 V), indicating a shift in the binding energy of carbon monoxide on the Pt condenser surface. A substantial increase in capacitance (∼2000 nF/cm 2 ) of the Pt-on-carbon devices was observed at elevated temperatures of 400 °C that can modulate ∼10% of charge per metal atom when 10 V potential was applied. A large catalytic condenser of 42 cm 2 area Pt/C/HfO 2 /Si exhibited a high capacitance of 9393 nF with a low leakage current/capacitive current ratio (<0.1), demonstrating the practicality and versatility of the facile, large-scale fabrication method for metal–carbon catalytic condensers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH