Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE ALIGNMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Data-driven prediction of geometry- and toolpath sequence-dependent intra-layer process conditions variations in laser powder bed fusion

Geometrical features and toolpath sequence are two important factors that cause process condition variations, such as variations in the meltpool temperature or meltpool size, that might lead to undesired material properties in the laser powder bed fusion (LPBF) process. Due to the high dynamics and complex physics of the LPBF process, it is difficult to predict variations in process conditions with simulations alone. Advances in measurement technology and computational technologies open up new possibilities for smart manufacturing. In this paper, a data-driven method to predict intra-layer variations in the processing conditions that source from the toolpath sequence and part geometry is presented. The approach is demonstrated using two-color on-axis pyrometer measurements. Three demonstration cases are presented in which it is demonstrated (1) how the trained predictive model can be used as a filter to ease the interpretation of process variations and discover patterns related to toolpath and part geometry, and (2) how to generate predictions that can be used for feedforward control, i.e., for adjusting laser power or scanning speed along the toolpath using a meltpool temperature prediction model generated based on on-axis measurements. Results show that the developed prediction model is able to meaningfully predict process variations resulted from toolpath sequence and geometry. Predictions are aligned with the results from the related work of others and for the case of 180° laser path turnarounds in our high-speed X-ray imaging experiments. In conclusion, the potential issues related to the current maturity status of the process and measuring equipment that could in practice affect the performance of the proposed solutions are also discussed.

42 ENGINEERING↗

Optically oriented attachment of nanoscale metal-semiconductor heterostructures in organic solvents via photonic nanosoldering

As devices approach the single-nanoparticle scale, the rational assembly of nanomaterial heterojunctions remains a persistent challenge. While optical traps can manipulate objects in three dimensions, to date, nanoscale materials have been trapped primarily in aqueous solvents or vacuum. Here, we demonstrate the use of optical traps to manipulate, align, and assemble metal-seeded nanowire building blocks in a range of organic solvents. Anisotropic radiation pressure generates an optical torque that orients each nanowire, and subsequent trapping of aligned nanowires enables deterministic fabrication of arbitrarily long heterostructures of periodically repeating bismuth-nanocrystal/germanium-nanowire junctions. Heat transport calculations, back-focal-plane interferometry, and optical images reveal that the bismuth nanocrystal melts during trapping, facilitating tip-to-tail “nanosoldering” of the germanium nanowires. These bismuth-semiconductor interfaces may be useful for quantum computing or thermoelectric applications. In addition, the ability to trap nanostructures in oxygen- and water-free organic media broadly expands the library of materials available for optical manipulation and single-particle spectroscopy.

42 ENGINEERING↗

Simultaneous imaging of vibrational, rotational, and electronic wave-packet dynamics in a triatomic molecule

Light-induced molecular dynamics often involve the excitation of several electronic, vibrational, and rotational states. Since the ensuing electronic and nuclear motion determines the pathways and outcomes of photoinduced reactions, our ability to monitor and understand these dynamics is crucial for molecular physics, physical chemistry, and photobiology. However, characterizing this complex motion represents a significant challenge when different degrees of freedom are strongly coupled. In this Letter, we demonstrate how the interplay between vibrational, rotational, and electronic degrees of freedom governs the evolution of molecular wave packets in the low-lying states of strong-field-ionized sulfur dioxide. Using time-resolved Coulomb explosion imaging (CEI) and quantum mechanical wave packet simulations, we directly map the bending vibrations of the molecule, show how the vibrational wave packet is influenced by molecular alignment, and elucidate the consequences of nuclear motion for the coupling between the two lowest electronic states of the cation. Furthermore, our results demonstrate that multicoincident CEI can be an efficient experimental tool for characterizing coupled electronic and nuclear motion in polyatomic molecules.

Atomic & molecular processes in external fields↗

Quantitative rescattering theory for high-order harmonic generation from molecules

The quantitative rescattering theory (QRS) for high-order harmonic generation (HHG) by intense laser pulses is presented. According to the QRS, HHG spectra can be expressed as a product of a returning electron wave packet and the photorecombination differential cross section of the laser-free continuum electron back to the initial bound state. We show that the shape of the returning electron wave packet is determined mostly by the laser. The returning electron wave packets can be obtained from the strong-field approximation or from the solution of the time-dependent Schroedinger equation (TDSE) for a reference atom. The validity of the QRS is carefully examined by checking against accurate results for both harmonic magnitude and phase from the solution of the TDSE for atomic targets within the single active electron approximation. Combining with accurate transition dipoles obtained from state-of-the-art molecular photoionization calculations, we further show that available experimental measurements for HHG from partially aligned molecules can be explained by the QRS. Our results show that quantitative description of the HHG from aligned molecules has become possible. Since infrared lasers of pulse durations of a few femtoseconds are easily available in the laboratory, they may be used for dynamic imaging of a transient molecule with femtosecond temporal resolutions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Building an Adaptive Optics Demonstrator System

Adaptive optics is used to correct the wavefront of a beam of light. It originated in the field of astronomy to correct for atmospheric turbulence. This project was to construct an adaptive optics (AO) system kit from Thorlabs. An AO system consists of three parts: a deformable mirror (DM), a wavefront sensor (WFS), and control software. This system is to be used for future teaching purposes to help others learn about adaptive optics. The AO system came with instruction manuals, which were followed to build and calibrate the system. The instructions included building and aligning the system, how to install and use the software, and how to calibrate deformable mirror. A calibrated system for this project means having the deformable mirror imaged onto the wavefront sensor, with the center of the mirror on the center of the WFS. Also, a flat wavefront, which is achieved by eliminating the tip/tilt of the mirror. Eliminating the tip/tilt reduces the RMS amplitude to a value below 0.200 microns. This causes the wavefront to fold in on itself. We set up a focal plane detector behind beam splitter as a demonstration of what would be seen if this were used with a telescope. The image that should be seen on the focal plane detector is the beam with a diffraction pattern called and Airy Function. The AO system is now ready to be used to teach others about adaptive optics.

79 ASTRONOMY AND ASTROPHYSICS↗

Probing the Outflowing Multiphase Gas ∼1 kpc below the Galactic Center

Comparison of interstellar medium (ISM) absorption in the UV spectrum of LS 4825, a B1 Ib−II star d = 21 ± 5 kpc from the Sun toward l = 1.°67 and b = −6.°63, with ISM absorption toward an aligned foreground star at d < 7.0 ± 1.7 kpc, allows us to isolate and study gas associated with the Milky Way nuclear wind. Spectra from the Space Telescope Imaging Spectrograph show low-ionization absorption out to d < 7 kpc (e.g., O i, C ii, Mg ii, Si ii, Fe ii, S ii) only between 0 and 40 km s{sup −1}, while absorption at d > 7 kpc, ∼1 kpc below the Galactic plane, is complex and spans −290 to +94 km s{sup −1}. The intermediate and high ions Si iii, C iv, Si iv, and N v show extremely strong absorption with multiple components from −283 to 107 km s{sup −1}, implying that the ISM ∼1 kpc below the Galactic center has a substantial reservoir of plasma and more gas containing C iv and N v than in the Carina OB1 association at z = 0 kpc. Abundances and physical conditions are presented for many absorption components. The high ion absorption traces cooling transition temperature plasma probably driven by the outflowing hot gas, while the extraordinarily large thermal pressure, p / k ∼ 10{sup 5} cm{sup −3} K{sup −1}, in an absorption component at −114 km s{sup −1} probably arises from the ram pressure of the outflowing hot gas. The observations are consistent with a flow whose ionization structure in the high ions can be understood through a combination of nonequilibrium radiative cooling and turbulent mixing.

79 ASTRONOMY AND ASTROPHYSICS↗

What is the Relationship Between Heavy Ion Outflow and High-Latitude Energetic Particle Precipitation?

This document is the fourth quarter progress report for year two on contract NAW-99002 'What is the relationship between heavy ion outflow and high latitude energetic particle precipitation'. In this project we are studying the relationship between the fluxes, mean energies, and field-aligned flow speeds of escaping suprathermal H+ and O+ measured by the TEAMS instrument on FAST and the energy flux of precipitating electrons obtained form the LBHL images taken by the Ultraviolet Imagery (UVI) camera on the Polar spacecraft. We have analyzed data from three time intervals, 7-11 Feb, 25-31 Jan, and 1-6 Feb 1997. We find that there indeed is a relationship between the O+ escape fluxes and the intensity of the aurora at the foot point of the field line. The time delay between an auroral intensification and the corresponding increase in escape flux is very short, only a few minutes. At low auroral luminosity the relationship between escape flux and luminosity appears to break down due possibly to the lack of sensitivity of the auroral emissions to large fluxes of low energy electrons.

Wilson, Gordon R.↗

What is the Relationship Between Heavy Ion Outflow and High-Latitude Energetic Precipitation?

Second quarter progress report for year 3 on contract NASW-99002 "What is the Relationship between heavy ion outflow and high latitude energetic particle precipitation". In this Project we are studying the relationship between the fluxes, mean energies, and field-aligned flow speeds of escaping suprathermal H+ and 0+ measured by the TEAMS instrument on FAST and the energy flux of precipitating electrons obtained from the LBHL images taken by the UVI camera on POLAR. In this portion of the project we are using UVI images to tell us when substorm onsets occur and how the auroral zone changes during the course of a substorm. We are correlating this information with TEAMS flux measurements made over the auroral zone at times close to these substorms. The goal is to understand how the flux of suprathermal ion outflow varies with substorm phase.

Wilson, Gordon R.↗

NASA Tech Briefs, June 2009

Topics covered include: Device for Measuring Low Flow Speed in a Duct, Measuring Thermal Conductivity of a Small Insulation Sample, Alignment Jig for the Precise Measurement of THz Radiation, Autoignition Chamber for Remote Testing of Pyrotechnic Devices, Microwave Power Combiners for Signals of Arbitrary Amplitude, Synthetic Foveal Imaging Technology, Airborne Antenna System for Minimum-Cycle-Slip GPS Reception, Improved Starting Materials for Back-Illuminated Imagers, Multi-Modulator for Bandwidth-Efficient Communication, Some Improvements in Utilization of Flash Memory Devices, GPS/MEMS IMU/Microprocessor Board for Navigation, T/R Multi-Chip MMIC Modules for 150 GHz, Pneumatic Haptic Interfaces, Device Acquires and Retains Rock or Ice Samples, Cryogenic Feedthrough Test Rig, Improved Assembly for Gas Shielding During Welding or Brazing, Two-Step Plasma Process for Cleaning Indium Bonding Bumps, Tool for Crimping Flexible Circuit Leads, Yb14MnSb11 as a High-Efficiency Thermoelectric Material, Polyimide-Foam/Aerogel Composites for Thermal Insulation, Converting CSV Files to RKSML Files, Service Management Database for DSN Equipment, Chemochromic Hydrogen Leak Detectors, Compatibility of Segments of Thermoelectric Generators, Complementary Barrier Infrared Detector, JPL Greenland Moulin Exploration Probe, Ultra-Lightweight Self-Deployable Nanocomposite Structure for Habitat Applications, and Room-Temperature Ionic Liquids for Electrochemical Capacitors.

Source record↗

Digital volume imaging of the PEFC gas diffusion layer

The gas diffusion layer (GDL) plays a key role in the overall performance/durability of a polymer electrolyte fuel cell (PEFC). Of profound importance, especially in the context of water management and flooding phenomena, is the influence of the underlying pore morphology and wetting characteristics Of the GDL microstructure. In this article, we present the digital volumetric imaging (DVI) technique in order to generate the 3-D carbon paper GDL microstructure. The internal pore structure and the local microstructural variations in terms of fiber alignment and fiber/binder distributions are investigated using the several 3-D thin sections of the sample obtained from DVI.

30 DIRECT ENERGY CONVERSION↗

Digital Volume Imaging of the PEFC Gas Diffusion Layer

The gas diffusion layer (GDL) plays a key role in the overall performance/durability of a polymer electrolyte fuel cell (PEFC). Of profound importance, especially in the context of water management and flooding phenomena, is the influence of the underlying pore morphology and wetting characteristics of the GDL microstructure. In this article, we present the digital volumetric imaging (DVI) technique in order to generate the 3-D carbon paper GDL microstructure. The internal pore structure and the local microstructural variations in terms of fiber alignment and fiber/binder distributions are investigated using the several 3-D thin sections of the sample obtained from DVI.

30 DIRECT ENERGY CONVERSION↗

Photogrammetric Metrology for the James Webb Space Telescope Integrated Science Instrument Module

The James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (approximately 40K). The JWST Observatory architecture includes the Optical Telescope Element and the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. The ISM optical metering structure is a roughly 2.2x1.7x2.2m, asymmetric frame that is composed of carbon fiber and resin tubes bonded to invar end fittings and composite gussets and clips. The structure supports the SIs, isolates the SIs from the OTE, and supports thermal and electrical subsystems. The structure is attached to the OTE structure via strut-like kinematic mounts. The ISIM structure must meet its requirements at the approximately 40K cryogenic operating temperature. The SIs are aligned to the structure's coordinate system under ambient, clean room conditions using laser tracker and theodolite metrology. The ISIM structure is thermally cycled for stress relief and in order to measure temperature-induced mechanical, structural changes. These ambient-to-cryogenic changes in the alignment of SI and OTE-related interfaces are an important component in the JWST Observatory alignment plan and must be verified. We report on the planning for and preliminary testing of a cryogenic metrology system for ISIM based on photogrammetry. Photogrammetry is the measurement of the location of custom targets via triangulation using images obtained at a suite of digital camera locations and orientations. We describe metrology system requirements, plans, and ambient photogrammetric measurements of a mock-up of the ISIM structure to design targeting and obtain resolution estimates. We compare these measurements with those taken from a well known ambient metrology system, namely, the Leica laser tracker system. We also describe the data reduction algorithm planned to interpret cryogenic data from the Flight structure. Photogrammetry was selected from an informal trade study of cryogenic metrology systems because its resolution meets sub-allocations to ISIM alignment requirements and it is a non-contact method that can in principle measure six degrees of freedom changes in target location. In addition, photogrammetry targets can be readily related to targets used for ambient surveys of the structure. By thermally isolating the photogrammetry camera during testing, metrology can be performed in situ during thermal cycling. Photogrammetry also has a small but significant cryogenic heritage in astronomical instrumentation metrology. It was used to validate the displacement/deformation predictions of the reflectors and the feed horns during thermal/vacuum testing (90K) for the Microwave Anisotropy Probe (MAP). It also was used during thermal vacuum testing (100K) to verify shape and component alignment at operational temperature of the High Gain Antenna for New Horizons. With tighter alignment requirements and lower operating temperatures than the aforementioned observatories, ISIM presents new challenges in the development of this metrology system.

Nowak, Maria↗

Finding a needle in a haystack: quantitative HERFD-XRF imaging and HERFD-XANES characterization of trace platinum in gold solidi from the Late Roman and Byzantine Empires

High-Energy Resolution Fluorescence Detection X-Ray Fluorescence (HERFD-XRF) imaging and HERFD X-ray Absorption Near Edge Structure (XANES) spectroscopy are used to quantify and characterize trace platinum (Pt) in gold solidi from the Late Roman and Byzantine Empires. Historically, the elemental analysis of coins has been pivotal in distinguishing authentic artifacts from forgeries, elucidating minting practices, and understanding economic shifts. Notably, a new gold source with high platinum content appeared in the fourth century CE, transforming the Roman economy. Traditional methods struggled to detect platinum due to the overwhelming gold matrix. Here, this study demonstrates the effectiveness of HERFD techniques in resolving this challenge. Three gold solidi, minted between 654 and 659 CE, were analyzed alongside reference gold materials with known Pt concentrations. The HERFD-XRF imaging revealed spatial distributions of platinum, highlighting non-uniformities within the coins. Additionally, HERFD-XANES spectroscopy identified the oxidation states and chemical speciation of platinum. Results demonstrate that platinum in the solidi primarily exists as metallic Pt, with some surface oxidation. The findings align with previous measurements but reveal higher Pt concentrations and significant inhomogeneities. This research confirms the reliability of HERFD methods for quantifying trace elements and provides new insights into the raw material sources and minting techniques of ancient gold coins. The non-destructive nature of this approach allows for extensive analyses, offering valuable data for historical, economic, and archaeological studies. This innovative application of HERFD-XRF imaging and XANES in cultural heritage research underscores the potential for detailed material characterization and conservation, enhancing our understanding of ancient economies and trade patterns.

Van Loon, Lisa L.↗

Hard X-ray imaging with sub-10 nm resolution by scanning bonded 2D multilayer Laue lenses

Multilayer Laue lenses (MLLs) offer significant advantages over traditional diffractive focusing optics, such as zone plates (ZPs), in terms of efficiency and durability when focusing hard X-rays to 10 nm and below. Typically, a pair of 1D MLLs is aligned independently to achieve point focusing. This approach only permits scanning microscopy by moving the sample stage, which presents a limitation when it comes to scanning large or bulky objects at high speed. In this study, we present an experimental demonstration of scanning monolithically bonded 2D MLLs while keeping the sample stationary, effectively addressing the limitation of the sample’s size and weight. We characterized the system’s positional and angular stabilities during scanning, which are critical parameters to the nanofocusing performance of MLLs. In addition, we provided the X-ray measurement results and corresponding image resolution analysis.

36 MATERIALS SCIENCE↗

TU-EF-204-04: Feasibility Study of a Novel Stationary Spectral CT Scanner

Purpose: To evaluate a cadmium zinc telluride (CZT) detector module and to develop a proof-of-concept bench-top system to examine the concept and feasibility of a stationary spectral scanner that would consist of a CZT detector ring and a distributed source for rotationless imaging. Methods: The bench-top system employs a double-rotation set-up with two concentric but independent rotating stages, one for turning the object at sparse angles to mimic the imaging from a sequentially activated source distributed on a ring, while the other for translating the detector module to simulate a projection arc along a virtual detector ring. A source of 30-degree fan is used in the set-up, and the ring is designed to be 85cm in diameter in order to provide a 22cm field-of-view that is large enough for an average human head. The CZT detector module has 16×16 0.5mm pixels and eight global energy thresholds, and is attached to an experimental data acquisition board from the same vendor (Nova R&D). Its pixel gain is first calibrated using radioisotope Tc-99m to align the photo-peaks. Count rate performance is assessed using the X-ray source. Air and offset corrections are done prior to each CT scan. A 10cm acrylic phantom with 5 different inserts is imaged at 100kVp, 2mA, with an effective exposure window of 150ms per projection. Reconstruction is done using a total variation-type iterative method. Results: The detector module exhibited large gain variations among pixels. Average count rate was over 1Mcps per pixel. Parallax effect was observed along the arcs but was corrected. Reconstructed images from two energy bins demonstrated good contrast, spatial resolution and image uniformity, with little artifacts. Conclusion: The CZT detector tested is suitable for imaging relatively small objects. A stationary spectral CT appears feasible should we have enough buttable modules and a distributed source. This work was supported by Ministry of Science and Technology of China through grants 11YQ040082 and 2012BAI13B04.

60 APPLIED LIFE SCIENCES↗

Tracking brachytherapy sources using emission imaging with one flat panel detector

This work proposes to use the radiation from brachytherapy sources to track their dwell positions in three-dimensional (3D) space. The prototype device uses a single flat panel detector and a BB tray. The BBs are arranged in a defined pattern. The shadow of the BBs on the flat panel is analyzed to derive the 3D coordinates of the illumination source, i.e., the dwell position of the brachytherapy source. A kilovoltage x-ray source located 3.3 m away was used to align the center BB with the center pixel on the flat panel detector. For a test plan of 11 dwell positions, with an Ir-192 high dose rate unit, one projection was taken for each dwell point, and locations of the BB shadows were manually identified on the projection images. The 3D coordinates for the 11 dwell positions were reconstructed based on two BBs. The distances between dwell points were compared with the expected values. The average difference was 0.07 cm with a standard deviation of 0.15 cm. With automated BB shadow recognition in the future, this technique possesses the potential of tracking the 3D trajectory and the dwell times of a brachytherapy source in real time, enabling real time source position verification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Redshift-dependent RSD bias from intrinsic alignment with DESI Year 1 spectra

ABSTRACT We estimate the redshift-dependent, anisotropic clustering signal in the Dark Energy Spectroscopic Instrument (DESI) Year 1 Survey created by tidal alignments of Luminous Red Galaxies (LRGs) and a selection-induced galaxy orientation bias. To this end, we measured the correlation between LRG shapes and the tidal field with DESI’s Year 1 redshifts, as traced by LRGs and Emission-Line Galaxies. We also estimate the galaxy orientation bias of LRGs caused by DESI’s aperture-based selection, and find it to increase by a factor of seven between redshifts 0.4−1.1 due to redder, fainter galaxies falling closer to DESI’s imaging selection cuts. These effects combine to dampen measurements of the quadrupole of the correlation function (ξ2) caused by structure growth on scales of 10–80 h−1 Mpc by about 0.15 per cent for low redshifts (0.4 < z < 0.6) and 0.8 per cent for high (0.8 < z < 1.1), a significant fraction of DESI’s error budget. We provide estimates of the ξ2 signal created by intrinsic alignments that can be used to correct this effect, which is necessary to meet DESI’s forecasted precision on measuring the growth rate of structure. While imaging quality varies across DESI’s footprint, we find no significant difference in this effect between imaging regions in the Legacy Imaging Survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Electric Field Conjugation in the Presence of Model Uncertainty

The Wide-Field Infrared Survey Telescope (WFIRST) is a 2.4-meter-diameter space telescope NASA program. The payload will include a coronagraph instrument (CGI). The CGI designs under development use deformable mirrors (DM) to create a point spread function (PSF) with a dark region around the obscured star object. Electric field conjugation (EFC) is an iterative nonlinear optimization procedure that uses measurements of the electric field at the image to determine the DM displacements to modify the PSF to create the region of high contrast in the image. EFC requires a numerical model of the coronagraph to calculate the Jacobian of the system, which is used, along with regularization, to solve for the DM displacements for each iteration of the nonlinear optimization. Ideally, the coronagraph is aligned and calibrated, and the calibration data are used in the numerical model for calculating the Jacobian. However, calibration and alignment measurements always contain uncertainty resulting in calibration error. Therefore, the Jacobian calculated from the numerical model is not an exact representation of the physical coronagraph, and the resulting DM solution for an EFC iteration does not have the exact impact on the electric field of the coronagraph as predicted by the EFC. The result is slow convergence, and, as will be shown, drives the use of more restrictive regularization. Using Monte Carlo trials, we investigate the effect of calibration error on EFC convergence and regulatization. Comparison to results from the High Contrast Imaging Testbed Hybrid Lyot Coronagraph are also presented.

Marx, David↗