Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inlets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Core-flood Effluent and Shale Surface Chemistries in Predicting Interaction between Shale, Brine, and Reactive Fluid

We report field and laboratory observations to date indicate that the efficiency of hydraulic fracturing, as it relates to hydrocarbon recovery, depends significantly on geochemical alterations to rock surfaces that diminish accessibility by partial or total plugging of the pore and fracture networks. This is caused by mineral scale deposition such as coating of fracture surfaces with precipitates, particle migration, and/or crack closure due to dissolution under stress. In reactive flow-through experiments, mineral reactions in response to acidic fluid injection significantly reduced system porosity and core permeability. The present study focuses on changes to fluid chemistry and shale surfaces (inlet and fracture walls) resulting from shale-fluid interactions and integrating these findings for an improved estimate of transport-related consequences. The reacted shale surfaces were examined by spatially-resolved scanning electron microscopy - energy dispersive spectroscopy (SEM-EDS) analysis. Importantly, inductively coupled plasma - mass spectrometry/optical emission spectroscopy (ICP-MS/OES) was utilized to probe the chemical evolution of the core-flood effluents. The three study cores selected from the Marcellus formation represent different mineralogies and structural features. In flow-through experiments, lab-generated brine and HCl-based fracture fluid (pH=2) were injected sequentially under effective stress (up to 500 psi) at reservoir temperature (80°C). SEM-EDS results confirmed by the ICP concentration trends showed significant Fe hydroxide precipitates in clay- and pyrite-rich outcrop samples due to partial oxidation of Fe-bearing phases in the case of intrusion of low salinity water-based fluids. Porosity reduction in the MSEEL (Marcellus Shale Energy and Environmental Laboratory) carbonate-rich sample is related to compaction of cores under stress due to matrix softening with substantial dissolution, and pore-filling by hydroxides, as well as barite and salts. Despite the same fluid compositions and experimental conditions used for both MSEEL samples, barite precipitation was much more intense in the MSEEL clay-rich sample due to its greater sorption capacity and additional sulfate source as well as fissile nature with multiple lengthwise cracks. ICP tests revealed time-resolved concentration trends in produced brine and reactive fluids that in turn complemented the pre-/post-reaction SEM-EDS observations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-speed phase contrast imaging of spray breakup of jet fuels under combusting conditions

X-ray phase contrast imaging is conducted at 90,517 Hz on a fuel spray to characterize the breakup of the bulk fuel into ligaments and individual droplets in a single-sector, swirl-stabilized combustor under reacting conditions. Phase contrast imaging is used to qualitatively assess spray breakup for two fuels: Jet-A, which represents a normal viscosity fuel, and a blend of JP-5 (64%) and farnesane (36% by volume), which represents a high-viscosity fuel, at three fuel-flow rates and two air inlet temperatures. Time-series images of the fuels show that atomization occurs much more rapidly at higher fuel pressure with thinner ligaments being rapidly shredded. The high-viscosity fuel is qualitatively observed to have markedly longer, thicker ligaments and larger droplet diameters after the primary breakup than the normal viscosity fuel. Using an image processing and droplet quantification strategy, the mean droplet velocity magnitudes were found to decrease with decreasing fuel pressure and fuel-flow rate. The increase in preheat temperature from 323 to 370 K results in an increase in the mean droplet velocity magnitude and a decrease in numerical average and Sauter mean diameter, indicating improved atomization. The high-viscosity fuel was found to have larger average droplet diameters at each condition than the normal viscosity fuel. The increased preheat is found to enhance the combustion efficiency, which is hypothesized to couple with the improved atomization due to the higher combustion temperatures. This indicates the importance of examining spray atomization and breakup under realistic combusting conditions for relevant fuels as the heat release directly couples with the atomization process.

42 ENGINEERING↗

High flux boiling heat transfer enhancement using triangle shaped vertical walls in two-phase microchannel heat exchangers

Two-phase heat exchangers allow heat loads to be dissipated with lower fluid flow rates without inducing thermal gradients, and high surface area microchannels further reduce the thermal resistance of these heat exchangers. However, there are many practical limits that prevent widespread use of two-phase microchannel heat exchangers. Many authors have looked to address these practical limits by treating the channel floors or creating artificial nucleation sites. Few works look to enhance heat transfer in the walls of channels with hydraulic diameters below 200 μm. This work is aimed at increasing the efficacy of high aspect ratio silicon microchannels that use R134a as the working fluid. The 125 parallel channels are 40 μm wide, 200 μm deep, and 2 mm long and contain a 15 μm wide, 150 μm long restriction at each inlet. The thermal resistance and dryout characteristics of traditional, plain-walled channels are compared to channels with 2 area enhancement patterns each of which increases the area available for heat transfer by 41%. Furthermore, a resistance to dryout is seen in both area-enhanced test sections, and a 15.5% reduction in thermal resistance is shown for the area-enhanced part with a 6 μm triangular pitch. Only a 7.8% performance increase is seen in the test section with a 3 μm pitch. Both area enhancement patterns induce an average 27% increase in pressure drop for all tests. Heat transfer characteristics are solved for using a finite element analysis (FEA) model. By examining heat transfer coefficients and local heat fluxes, it is postulated that the area enhancement reduces heat transfer coefficients and the performance increase is caused by increasing the number of active nucleation sites.

42 ENGINEERING↗

Effects of additively manufactured surface roughness on small diameter plenums with multiple side discharges for high temperature gas turbine blade cooling applications

Combined heat and power (CHP) applications have significant environmental and economic benefits that are consistent with the goals of the U.S. Department of Energy (DOE). One area that is currently being studied includes the potential benefits of CHP turbine operation at higher turbine inlet temperatures. Internal cooling concepts enabled by additive manufacturing (AM) are of primary interest. Here, the effectiveness of internal cooling is hindered by many factors such as velocity distribution of the cooling air to the hot surface considering impingement cooling. To simulate cooling air exiting from a series of orifices for internal cooling in an airfoil, a straight smooth wall tubing with multiple side discharging orifices is used and compared to additively manufactured tubing (Ti6Al4V Grade 23) with orifice size and spacing as well as inner and outer diameters identical to the smooth wall tubing. Similar to flow discharging form perforated pipes, the flow discharged from individual orifices along the tubes in this study is found to be nonuniformly distributed, and the horizontal (axial direction) momentum can be observed from the experimental data. Discharge velocities have been measured with two-dimensional (2D) particle imaging velocimetry (PIV) and single element hot wire anemometry. Numerical analysis has also been conducted to predict the velocity distributions along the orifices in the smooth wall and additive manufacturing (AM) tubing, which are inherited with surface roughness. Numerical and measured results in this study are compared, presented, and discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resolving the Energy–Water Nexus in Large Thermoelectric Power Plants: A Case for Application of Enhanced Heat Transfer and High-Performance Thermal Energy Storage

The acute energy and water consumption stress on global economies warrants a reexamination of the energy–water nexus and urgent innovative engineering solutions. To address the attendant challenges in large-scale thermoelectric power plants, especially where evaporative cooling towers are used that consume more than 73% of their annual cooling water withdrawals, a transformative dry-cooling (or air-cooling) system is proposed in this paper, which consists of a novel daytime peak-load shifting system that pre-cools the daytime peak-temperature air in order to mitigate concomitant second-law limitation for air cooling. The highly compact and enhanced air pre-cooler transfers the daytime heat load to a unique thermal energy storage (TES) system. The TES operates over a range of temperatures and is recharged by an asynchronous nighttime air-cooled exchanger. Moreover, the air-cooled condenser (ACC) is designed with an enhanced surface core, with substantially higher heat transfer coefficients, such that it operates with a smaller inlet temperature difference. This allows the ACC to sustain lower condensing pressures. Thus, the system not only makes dry air cooling (zero net water dissipation for cooling) viable but also significantly increases the power plant output.

36 MATERIALS SCIENCE↗

PINCH POINT ANALYSIS OF GAS COOLERS IN TRANSCRITICAL R1336mzz(Z) HIGH-TEMPERATURE HEAT PUMPS

The majority of high-temperature heat pumps (HTHPs) operate subcritical vapor compression cycles, where the maximum sink temperature is limited by the critical temperature of refrigerants. In HTHPs with a sink temperature of ≥ 150°C, transcritical cycles overcome this limitation by rejecting heat in the supercritical regions of refrigerant. Supercritical refrigerants in gas coolers have a large temperature glide and substantial nonlinear variation in specific heat capacity vs. temperature. Closely matching the refrigerant glide temperature and the heat sink temperature profile greatly impacts the heat transfer characteristic of gas coolers and the overall performance of HTHPs. This study conducts a pinch point analysis for the gas cooling process of supercritical R1336mzz(Z) in HTHPs. A finite volume element model of a supercritical R1336mzz(Z) counterflow gas cooler is built and solved. This study evaluates the influences of operating conditions, including inlet and outlet of coolants, refrigerant evaporation temperature and superheat degree, pinch temperature difference, and heat rejection pressure, on the performance of HTHPs. The optimal discharge pressures in gas coolers are proposed for industrial spray dryers in providing drying air at 170°C−210°C. The results of the present study help design gas coolers in transcritical R1336mzz(Z) HTHPs.

Wang, Pengtao↗

INVESTIGATION OF HELIUM FLOW LAMINARIZATION AT HIGH TEMPERATURES AND HIGH PRESSURES IN A GRAPHITE FLOW CHANNEL

Abstract: Forced convection experiments were performed with helium to investigate thermal hydraulic phenomena in a heated graphite test section. Flow regimes include turbulent, transition and laminar flows with Reynolds numbers between 500 and 5,000. Experiments were performed with upward flow at different helium temperatures and pressures up to 550 oC and 61 bar, respectively, various flow rates (50-500 SLPM), and heater power up to 6.5 kW. The analyses of the experimental data showed significant reductions in the Reynolds number of up to 50% over the 2.7 m test section between the gas inlet and outlet. Flow laminarization caused by intense heating was defined to occur when the local Nusselt number decreased below 20% of the Nusselt number based on the Gnielinski correlation. In this study, a flow laminarization criterion was considered based on a dimensionless acceleration parameter (Kv) and buoyancy parameter (Bo). Experiments involved high heating rates leading to the wall-to-bulk temperature ratios ranging from 1.8 to 3.4, dimensionless heat flux (q+) from 1x10^-4 to 7x10^-3 and buoyancy parameter (Bo) from 0.001 to 0.5. The latter range covers a value of Bo˜0.1 that has previously been suggested to correspond to the onset of the influence of the buoyancy force.

99 GENERAL AND MISCELLANEOUS↗

AmeriFlux US-Bsg Burns Sagebrush

This is the AmeriFlux version of the carbon flux data for the site US-Bsg Burns Sagebrush. Site Description - The site was established in 2012 and is part of a NOAA observation network for high precision measurements of carbon dioxide concentrations. It is located about 60 km southwest of Burns, Oregon in the Oregon High Desert. The vegetation in this area is dominated by sagebrush. The sampling inlets are at the heights of 18.5, 28.5, and 38.5 m. Gas analysis is performed with a Picarro 2302 Cavity Ringdown Spectrometer and a Li-Cor 7200 enclosed path IRGA. The tower is also equipped with a set of meteorological instruments, including an HMP sensor, radiation sensors (incoming and diffuse PAR, Net radiometer), and a CSAT3 sonic anemometer. This site is also part of the PhenoCam network operated by Harvard University and the University of New Hampshire.

Still, Chris↗

AmeriFlux AR-Cel CELPA Mar Chiquita BA

This is the AmeriFlux version of the carbon flux data for the site AR-Cel CELPA Mar Chiquita BA. Site Description - The site is located at a mid-latitude South Atlantic pristine salt marsh. It occupies 43 km2 of an extended marginal flat surrounding a 25 km long brackish lagoon connected with the Argentine Sea through an inlet channel. The small tide amplitude prevents extensive waterlogging with salt water. Unlike other Northern Hemisphere salt marshes regularly flooded by daily tides, Mar Chiquita soaks throughout the winter with approximately a 10 cm freshwater layer coming from rains, and during summer high temperatures and high evapotranspiration dry the soil, producing a thin salt crust on the surface. Another significant difference is that the canopy persists throughout the year without dying out, due to the lack of snowfall or below-freezing winter temperatures.

Gassmann, Maria Isabel↗

AK112: Full Waveform Inversion Tomography of Alaska Improves Waveform Fits While Imaging Crustal, Mantle, and Slab Structure

We report a full waveform inversion tomography model of Alaska and the surrounding regions, inferring radially anisotropic shear and isotropic compressional wavespeeds by fitting complete waveforms from 120 regional earthquakes. Our multiscale approach inverted time–frequency phase misfits (maximum period of 100 s), starting with a minimum period of 40 s and ending at 20 s in 7 stages and 112 total iterations. The model (AK112) was evaluated by computing the misfits for 36 independent validation events. We find that misfit reductions were large and equal (∼55%) for both the inversion and validation data sets, providing confidence in the model. AK112 also provides much better waveform fits compared to other reported models for the region, including an isotropic version of itself, highlighting the importance of anisotropy. The model resolves known crustal, upper mantle, and slab structure to depths of 100 km with new detail: sedimentary basins in the Alaskan Shelf, Cook Inlet, and Colville basins, among others; discontinuous lithospheric structure across major terrane boundaries; and subducting slab geometry and back‐arc volcanic sources. In addition to tectonic interpretations, the model enables full waveform simulations for long‐period earthquake ground motions and source characterization (e.g., moment tensor and finite‐fault inversion).

Rodgers, Arthur [Lawrence Livermore National Labor↗

DRDMannTurb: A Python package for scalable, data-driven synthetic turbulence

Synthetic turbulence models (STMs) are used in wind engineering to generate realistic flow fields and are employed as inputs to industrial wind simulations. Examples include prescribing inlet conditions in large eddy simulations that model loads on wind turbines and tall buildings. We are interested in STMs capable of generating fluctuations based on prescribed second-moment statistics since such models can simulate environmental conditions that closely resemble on-site observations. To this end, the widely used Mann model (see Mann, 1994, 1998) is the inspiration for DRDMannTurb. The Mann model is described by three physical parameters: a magnitude parameter influencing the global variance of the wind field and corresponding to the Kolmogorov constant multiplied by the rate of viscous dissipation of the turbulent kinetic energy to the two-thirds, αϵ 2/3 , a turbulence length scale parameter L, and a nondimensional parameter Γ related to the lifetime of the eddies. A number of studies, as well as international standards (e.g., those by the International Electrotechnical Commission (IEC)), include recommended values for these three parameters with the goal of standardizing wind simulations according to observed energy spectra. Yet, having only three parameters, the Mann model faces limitations in accurately representing the diversity of observable spectra. This Python package enables users to extend the Mann model and more accurately fit field measurements through flexible neural network models of the eddy lifetime function. Following Keith et al. (2021), we refer to this class of models as Deep Rapid Distortion (DRD) models. DRDMannTurb also includes a general module implementing an efficient method for synthetic turbulence generation based on a domain decomposition technique. This technique is also described in Keith et al. (2021).

17 WIND ENERGY↗

Fast and Accurate Core Analysis by the Full-Immersion Pressure-Pulse Decay: Part 1—Theory

Summary Core-scale measurements are considered the ground truth that oil and gas or electric utility companies use to predict the migration of fluids such as oil, natural gas, carbon dioxide, or brine deep underground during their extraction or injection operations. To provide a greater understanding of petrophysical properties of low-permeability geologic formations such as shales and tight gas sandstones, this study introduces a novel core-analysis procedure. The technique follows conventional pressure-pulse-decay permeametry, where the pressure in an inlet chamber adjacent to a cylindrical core plug undergoes a rapid pressurization, the system is shut in, and the pressure reaches a new equilibrium. However, unlike a standard unidirectional pressure-pulse decay, the full-immersion pressure-pulse decay (Hannon 2019) applies a pressure disturbance to the entire outer surface area of the sample. This article covers the numerical simulator designed to model flow through an anisotropic porous sample in this scenario. The model assumes distinct but uniform permeabilities along the radial and axial directions of the cylindrical plug sample. When extracting a plug vertically (or perpendicular to bedding), the permeability along the radial direction associates with the horizontal permeability (i.e., parallel to bedding), whereas in the axial direction, flow occurs perpendicular to bedding (a vertical permeability). Investigations of these model outputs demonstrate an approximately 20-fold decrease in time to complete a full-immersion experiment compared with conventional pressure-pulse decay. Furthermore, the pressure-decay curves resulting from the full-immersion method have slightly different shapes than those resulting from other unidimensional transient methods. These differences begin to demonstrate that, under achievable experimental conditions, the analysis of pressure data from one full-immersion test could enable the simultaneous estimation of the apparent permeabilities parallel and perpendicular to bedding of a cylindrical sample in addition to its porosity. A follow-up article finalizes the proof of this capability with a parameter-estimation procedure and presents experimental verification through a proof-of-concept study. Described in greater detail in that article, the parameter estimator requires multiple forward simulations to analyze the data, which behooves minimizing the compute time for each simulation. By using an alternating direction implicit time-marching scheme and a structured but variably spaced grid, the numerical simulator built for this purpose provides a forward model output with suitable accuracy in approximately 0.5 seconds.

Energy & Fuels↗

Experimental Study of Transport Behavior of Swellable Microgel Particles in Superpermeable Channels for Conformance Control

Summary Gel treatment is an effective way to attack excessive water production during oil development. The transport behavior of gel materials in reservoirs is of crucial importance to the effectiveness of gel treatments. The aim of this paper is investigating the transport behavior of swellable micrometer-sized preformed particle gels (PPGs, or microgels) through superpermeable (super-K) channels. Sandpacks with permeabilities ranging from 27 to 221 darcies were used to mimic the super-K channels. Multiple pressure sensors were applied along the sandpack models to monitor the propagation behavior of the microgels. The tested microgel particles could transport through the super-K channels, and a higher driving pressure gradient was required when the particle/pore size ratio was larger. The pressure gradient distribution along the super-K channels was relatively uniform when the particle/pore ratio was low (less than 1.3). However, the inlet section would show increasingly higher pressure gradients as the particle/pore ratio was increased, indicating increased difficulty in propagation. The propagation of the gel particles was significantly slower compared with the carrying fluid. The delayed propagation behavior was more pronounced when the particle/pore ratio was higher. The injection pressure was much less sensitive to the injection flow rate compared with a Newtonian fluid. The gel dispersion exhibited an apparent shear thinning (pseudoplastic) behavior when transporting through the porous channels. Breakage of the gel particles was observed especially at high superficial velocities. The particle breakage was partially responsible for the apparent shear thinning behavior. The breakage phenomenon was in favor of deep placement of the gel particles. The channel permeabilities were significantly reduced by the microgels, bringing sufficient resistance to subsequent waterflooding (more than 99.5%). At given matching size conditions, softer gels were more likely to establish in-depth placement and uniform water blocking capacity in the channels. The microgel particles exhibited salinity-responsive behavior to the post-brine flush. The gel particles could shrink and reswell according to the salinity of the injected water. Possibilities were discussed to use this salinity-responsive behavior. Also, the microgels exhibited a particular disproportionate permeability reduction (DPR) effect. After gel injection, the channel permeability to water flow was reduced by more than 20 to 92 times of the permeability to oil flow. This work provides important support to understand the transport behavior of gel particles in super-K channels. The achievements are helpful for gel product selection and gel treatment design.

Engineering↗

Transport and Transformation of Selenium and Other Constituents of Flue‐Gas Desulfurization Wastewater in Water‐Saturated Soil Materials

Constructed wetland treatment systems are used to remove selenium (Se) from flue‐gas desulfurization (FGD) wastewater (WW). However, direct confirmation of the mechanism responsible for FGD WW Se retention in soil is lacking. A laboratory‐based soil column study was performed to develop an evidence‐based mechanism of Se retention and to study the behavior and the retention capacity of FGD WW constituents in water‐saturated soil. A deoxygenated 1:1 mixture of FGD WW and raw water was delivered to the columns bottom‐up at a flux of 1.68 cm d −1 for 100 d. Some of the columns were flushed with the raw water at the same rate for an additional 100 d. Column effluent was analyzed for constituents of concern. Results showed a complete retention of FGD WW Se in the soil materials. Boron and fluorine were partially retained; however, sulfur, sodium, and chlorine retention was poor, agreeing with field observations. The FGD WW Se was retained in soil near the inlet end of the columns, indicating its limited mobility under reduced conditions. Sequential extraction procedure revealed that retained Se was mainly sequestered as stable/residual forms. Bulk‐ and micro‐X‐ray absorption near‐edge structure spectroscopy confirmed that Se was mainly retained as reduced/stable species [Se(IV), organic Se, and Se(0)]. This study provides direct evidence for FGD WW Se retention in water‐saturated soil via the transformation of oxidized Se into reduced/stable forms. Core Ideas The mechanism of FGD wastewater Se retention in water‐saturated soil was studied. Sequential fractionation of Se, micro‐XRF, and micro‐ and bulk‐XANES were used. Behavior of FGD wastewater constituents in saturated soil was comparable to field‐scale observations. FGD wastewater Se exhibited strong retention in reduced soil. Reduced/stable species of Se governed the retention mechanism.

Galkaduwa, Madhubhashini B.↗

An automated tool for three types of saturated hydraulic conductivity laboratory measurements

Acquisition of porous medium hydraulic conductivity in the laboratory is usually time-consuming and costly because of the manual labor associated with the currently available techniques. Lately, there has been increased interest in automating hydraulic conductivity laboratory techniques to reduce analysis time and improve data consistency. A new apparatus is presented that is able to determine hydraulic conductivity values with the falling head, constant head, and constant flux methods in an automated fashion. In addition, the columns are designed forcing water to flow in a nominally one-dimensional manner throughout the porous medium. In this paper, hydraulic conductivity data for standard laboratory sands are presented and compared to results obtained using a standard Tempe cell configuration. Hydraulic conductivity values obtained with the new tool for the laboratory sands are consistent with literature data. For highly permeable sands, the newly obtained hydraulic conductivity values are considerable larger then values acquired using a Tempe cell configuration. The lower conductivity values for the Tempe Cell configuration are primarily the result of insufficient spreading of water in the inlet and outlet reservoirs.

47 OTHER INSTRUMENTATION↗

Aggregate-scale heterogeneity in iron (hydr)oxide reductive transformations

There is growing awareness of the complexity of potential reaction pathways and the associated solid-phase transformations during the reduction of Fe (hydr)oxides, especially ferrihydrite. An important observation in static and advective-dominated systems is that microbially produced Fe(II) accelerates Ostwald ripening of ferrihydrite, thus promoting the formation of thermodynamically more stable ferric phases (lepidocrocite and goethite) and, at higher Fe(II) surface loadings, the precipitation of magnetite; high Fe(II) levels can also lead to green rust formation, and with high carbonate levels siderite may also be formed. This study expands this emerging conceptual model to a diffusion-dominated system that mimics an idealized micropore of a ferrihydrite-coated soil aggregate undergoing reduction. Using a novel diffusion cell, coupled with micro-x-ray fluorescence and absorption spectroscopies, we determined that diffusion-controlled gradients in Fe{sup 2+}{sub (aq)} result in a complex array of spatially distributed secondary mineral phases. At the diffusive pore entrance, where Fe{sup 2+} concentrations are highest, green rust and magnetite are the dominant secondary Fe (hydr)oxides (30 mol% Fe each). At intermediate distances from the inlet, green rust is not observed and the proportion of magnetite decreases from approximately 30 to <10%. Across this same transect, the proportion of goethite increases from undetectable up to >50%. At greater distances from the advective-diffusive boundary, goethite is the dominant phase, comprising between 40 and 95% of the Fe. In the presence of magnetite, lepidocrocite forms as a transient-intermediate phase during ferrihydrite-to-goethite conversion; in the absence of magnetite, conversion to goethite is more limited. These experimental observations, coupled with results of reactive transport modeling, confirm the conceptual model and illustrate the potential importance of diffusion-generated concentration gradients in dissolved Fe{sup 2+} on the fate of ferrihydrite during reduction in structured soils.

54 ENVIRONMENTAL SCIENCES↗

Desiccation of unsaturated porous media: Intermediate-scale experiments and numerical simulation

Soil desiccation (drying) is recognized as a potentially robust vadose zone remediation process involving water evaporation induced by air injection and extraction. Desiccation has the potential to immobilize contaminants and could potentially improve access for other gas-phase treatments by reducing water saturation and therefore increasing sediment gas-phase permeability. Before this technology could be deployed in the field, concerns related to energy limitations, osmotic effects, and potential contaminant remobilization after rewetting need to be addressed. A series of detailed wedge-shaped, intermediate-scale laboratory experiments in unsaturated homogeneous and simple heterogeneous systems was conducted to improve the understanding of the impact of energy balance issues on soil desiccation. The experiments were simulated with the multifluid flow simulator STOMP, using independently obtained hydraulic and thermal porous medium properties. In all the experiments, the injection of dry air proved to be an effective means for removing essentially all moisture from the test media. Evaporative cooling was observed which generally decreased with increased distance from the gas inlet chamber. Observations of temperature in fine-grained sands in the heterogeneous systems show two local temperature minima associated with the cooling. The first one occurs because of evaporation in the adjacent medium-grained sand whereas the second minimum is attributed to evaporative cooling in the fine-grained sand itself. Results of the laboratory tests were simulated accurately when thermal properties of the flow cell walls and insulation material were taken into account, indicating that the proper physics were incorporated into the simulator.

54 ENVIRONMENTAL SCIENCES↗

Comparison of Alternatives to the 2004 Vacuum Vessel Heat Transfer System

A study comparing different alternatives for the Vacuum Vessel Primary Heat Transfer System has been completed. Three alternatives were proposed in a Project Change Request (PCR-190) by relocating the heat exchangers (HXs) from the roof of the Tokamak building to inside the Vacuum Vessel Pressure Suppression System (VVPSS) tank. The study evaluated the three alternatives and recommended modifications to one of them to arrive at a preferred configuration that included relocating the HXs inside the Tokamak building but outside the VVPSS tank as well as including a small safety-rated pump and HX in parallel to the main circulation pump and HX. The Vacuum Vessel (VV) Primary Heat Transfer System (PHTS) removes heat generated in the VV during normal operation (10 MW, pulsed power) as well as the decay heat from the VV itself and from the structures/components attached to the VV (first wall, blanket, and divertor {approx}0.48 MW peak). Therefore, the VV PHTS has two safety functions: (1) contain contaminated cooling water (similar to the other PHTSs) and (2) provide passive cooling during an accident event. The 2004 design of the VV PHTS consists of two independent loops, each loop cooling half of the 18 VV segments with a nominal flow of 475 kg/s of water at about 1.1 MPa and 100 C. The total flow for both loops is 950 kg/s. Both loops are required to remove the heat load during normal plasma operation. During accident conditions, only one loop is needed to remove by natural convection (no pump needed) the decay heat of the complete VV and attached components. The heat is transferred to heat exchanger (HXs) located on top of the roof, outside the Tokamak building. These HXs are air-to-water (A/W) HXs. Three alternatives have been proposed for this cooling system. For a detailed discussion of these alternatives, please refer to Project Change Request, PCR-190 (Ref. 1). A brief introduction is given here. Alternative 1 includes only one main forced circulation loop with a small safety-rated pump in parallel with the main circulation pump. In addition, this alternative has two natural circulation safety loops. Both the safety and main loops supply water to the bottom of the VV with six branch lines and collect the heated water at the top of the vessel through six branches. The distribution headers are located in the lower pipe chase and the collection headers in the upper pipe chase. Each of these loops (one main and two emergency) has a HX mounted in the Vacuum Vessel Pressure Suppression System (VVPSS) tank. The main HX is cooled using either Component Cooling Water System (CCWS) or Chilled Water System (CHWS) water, and the emergency HXs are cooled by natural circulation of the VVPSS water. See Fig. 1 taken from PCR-190. Alternative 2 is exactly the same as Alternative 1 except that there is only one emergency loop and one emergency HX. See Fig. 2 taken from PCR-190. Alternative 3 also has one main forced circulation loop with a small safety-rated pump in parallel with the main circulation pump and one natural circulation safety loop. In this case, both the safety and main loops supply water to the top of the VV with three branch lines and collect the heated water at the top of the vessel through three branches. Here, the distribution header is located in the upper pipe chase as is the collection header. As before, each of these loops has a HX mounted in the VVPSS tank. The main HX is cooled using either CCWS or CHWS water, and the emergency HXs are cooled by natural circulation of the VVPSS water. See Fig. 3 taken from PCR-190. The preferred configuration is developed by selecting specific attributes of the other configurations analyzed and the logic for selecting this configuration is discussed at the end of the document. It is a modification of Alternative 2 that eliminates the separate safety loop, but incorporates a small safety rated HX and pump in parallel with the main HX and pump. It uses 18 inlet and 18 outlet branches (as did the 2004 design) and locates the HXs outside of the VVPSS tank. Tables 1 and 2 examine alternatives to the 2004 VV heat transfer system design that were proposed in PCR-190, as well as the preferred option.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗