Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Toward Autonomous Field Inspection of CSP Collectors With a Polarimetric Imaging Drone

We developed a polarimetric imaging drone to perform field inspections of heliostats and carried out field tests at Sandia’s National Solar Thermal Test Facility (NSTTF). The preliminary results show that Degree of Linear Polarization (DOLP) and Angle of Polarization (AOP) images greatly enhanced the edge detection results compared with the conventional visible images, supporting fast and accurate detection of heliostat mirror edges and cracks. The system holds the promise to enable future automated detection of heliostats optical errors and mirror defects.

14 SOLAR ENERGY↗

Study of Plastic Scintillator Properties for Radioactive Sources Dosimetry - Paper 108

Plastic scintillator is a simple material which has the density close to that of human soft tissue (1.06 g/cm{sup 3}). Its energy response is close to that of human soft tissue and it is relatively energy independent. This prospect provide a desired characteristics in measuring dose by plastic scintillator either for radiation monitoring or personal dosimeter. Generally the energy calibration of organic scintillator will be done by using gamma ray sources. The positions of Compton edge in pulse height spectra, which have known energy values will be identified. However the Compton edge normally is very broad and difficult to determine the point corresponding to that particular Compton electron energies. Many researchers used several fitting functions and Monte Carlo simulations to determine the position of Compton edge. For example, Proctor and Wellman (2012) used a straight line fit to the linear part of Compton edge and extrapolated to zero count. While L. Swiderski et al. used a method based on a back-scattered coincidence measurement to measure in a wide energy range the position of Compton edge in organic scintillators. For a simple and quick approach of calibration, we used a Gauss-error function to fit the Compton edge region of interest by assumed that the location of maximum energy of Compton electrons is half-height of the Compton maximum (CM). The reasons is because the CM position could be determined easily from the spectra throughout wide energy range. Interpreting gamma dose rates from accumulated plastic scintillation detector spectra is often a complex task because the probability of a full energy deposition event in the detector is often negligible. Despite no full energy peaks in plastic scintillator spectra, several attempts have been made by the other researchers to obtain the dose from the energy distribution spectra of gamma radiation. For example, Proctor and Wellman used the modified spectrum dose index (SDI) to calculate the exposure rates by multiplying the energy corresponding to its channel and all products are summed before multiply by a calibration constant to yield an exposure rate. While Lobdell and Hertel calculated dose using a response matrix based on spectral unfolding technique. From these points of view, we have made an attempt to correlate the counts obtained in scintillator with absorbed dose or ambient dose equivalent. We aimed to calibrate the plastic scintillator energy deposition for dose, by correlate the counts obtained with a particular value of dose. By designed the scintillator to measure at 1 cm tissue depth might be helpful to be used as radiation monitoring or personal dosimeter since the energy response of plastic scintillator is relatively energy independent compared to that of inorganic scintillators. The energy calibration proposed from simple fitting approach had been verified with calculated spectra. This might be considered as a practical approach for technician or radiation workers with sufficient accuracy. The linear behavior of counts per absorbed dose give promising to calibrate scintillator energy deposition to read dose (equivalent dose or absorbed dose) for photons. Thus the scintillator could provide both the energy and dose response simultaneously, which may important in some radiation field of measurements. Currently the scintillator is able to give dose rate value for gamma sources of Cs-137 and Mn-54. The number of counts per unit absorbed dose would likely to vary somewhat with photon energy, although the plastic scintillator should have a tissue dose response that is relatively energy independent. Further analysis will be done on conversion factor parameters so that it could be used in such situations where the radiation field is complex or unknown. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a spectroscopic detector for application in x-ray computed tomography

Recent advances in cadmium telluride (CdTe) energy-discriminating pixelated detectors have enabled the possibility of Multi-Spectral X-ray Computed Tomography (MSXCT) to incorporate spectroscopic information into CT. MultiX ME 100 V2 is a CdTe-based spectroscopic x-ray detector array capable of recording energies from 20 to 160 keV in 1.1 keV energy bin increments. Hardware and software have been designed to perform radiographic and computed tomography tasks with this spectroscopic detector. Energy calibration is examined using the end-point energy of a bremsstrahlung spectrum and radioisotope spectral lines. When measuring the spectrum from Am-241 across 500 detector elements, the standard deviation of the peak-location and FWHM measurements are ±0.4 and ±0.6 keV, respectively. As these values are within the energy bin size (1.1 keV), detector elements are consistent with each other. The count rate is characterized, using a nonparalyzable model with a dead time of 64 ± 5 ns. This is consistent with the manufacturer’s quoted per detector-element linear-deviation at 2 Mpps (million photons per sec) of 8.9% (typical) and 12% (max). When comparing measured and simulated spectra, a low-energy tail is visible in the measured data due to the spectral response of the detector. If no valid photon detections are expected in the low-energy tail, then a background subtraction may be applied to allow for a possible first-order correction. If photons are expected in the low-energy tail, a detailed model must be implemented. A radiograph of an aluminum step wedge with a maximum height of about 20 mm shows an underestimation of attenuation by about 10% at 60 keV. This error is due to partial energy deposition from higher-energy (> 60 keV) photons into a lower-energy (~60 keV) bin, reducing the apparent attenuation. A radiograph of a PTFE cylinder taken using a bremsstrahlung spectrum from an x-ray voltage of 100 kV filtered by 1.3 mm Cu is reconstructed using Abel inversion. As no counts are expected in the low energy tail, a first order background correction is applied to the spectrum. The measured linear attenuation coefficient (LAC) is within 10% of the expected value in the 60 to 100 keV range. Below 60 keV, low counts in the corrected spectrum and partial energy deposition from incident photons of energy greater than 60 keV into energy bins below 60 keV impact the LAC measurements. This report ends with a demonstration of the tomographic capability of the system. The quantitative understanding of the detector developed in this report will enable further study in evaluating the system for characterization of an object’s chemical make-up for industrial and security purposes.

36 MATERIALS SCIENCE↗

Universal Polarization Transformations: Spatial Programming of Polarization Scattering Matrices Using a Deep Learning‐Designed Diffractive Polarization Transformer

Abstract Controlled synthesis of optical fields having nonuniform polarization distributions presents a challenging task. Here, a universal polarization transformer is demonstrated that can synthesize a large set of arbitrarily‐selected, complex‐valued polarization scattering matrices between the polarization states at different positions within its input and output field‐of‐views (FOVs). This framework comprises 2D arrays of linear polarizers positioned between isotropic diffractive layers, each containing tens of thousands of diffractive features with optimizable transmission coefficients. After its deep learning‐based training, this diffractive polarization transformer can successfully implement N i N o = 10 000 different spatially‐encoded polarization scattering matrices with negligible error, where N i and N o represent the number of pixels in the input and output FOVs, respectively. This universal polarization transformation framework is experimentally validated in the terahertz spectrum by fabricating wire‐grid polarizers and integrating them with 3D‐printed diffractive layers to form a physical polarization transformer. Through this set‐up, an all‐optical polarization permutation operation of spatially‐varying polarization fields is demonstrated, and distinct spatially‐encoded polarization scattering matrices are simultaneously implemented between the input and output FOVs of a compact diffractive processor. This framework opens up new avenues for developing novel devices for universal polarization control and may find applications in, e.g., remote sensing, medical imaging, security, material inspection, and machine vision.

Optical neural networks↗

Computational framework for modeling membrane processes without process and solution property simplifications

Accurately modeling membrane processes is critical to evaluating novel process configurations, designing scalable membrane systems, informing process cost estimates, and directing future research. Most membrane process models trade accuracy for computational efficiency by employing simplified approximations of the process (i.e. no salt flux, no pressure drop) and solution properties (i.e. ideal solution, and constant density, viscosity, and diffusivity). Our report introduces a detailed one-dimensional finite difference model for evaluating membrane processes that avoids these common simplifications. We apply this model to quantify the error introduced by these simplifications for case studies of reverse osmosis, osmotically assisted reverse osmosis, forward osmosis, and pressure retarded osmosis. While the magnitude of error introduced by these simplifications is reliant on the case study parameters and specifications, we find that existing model formulations can underestimate or overestimate average water flux by nearly 50% for some membrane processes operating under standard conditions. Lastly we investigate the error introduced by simplified inlet-outlet models that do not solve the governing system of differential equations, and we assess the accuracy of novel inlet-outlet formulations that use a log and geometric mean, instead of the typical arithmetic mean, to represent non-linear water flux profiles.

42 ENGINEERING↗

Generative modeling enables molecular structure retrieval from Coulomb explosion imaging

Capturing the structural changes that molecules undergo during chemical reactions in real space and time is a long-standing dream and an essential prerequisite for understanding and ultimately controlling femtochemistry. A key approach to tackle this challenging task is Coulomb explosion imaging, which benefited decisively from recently emerging high-repetition-rate X-ray free-electron laser sources. With this technique, information on the molecular structure is inferred from the momentum distributions of the ions produced by the rapid Coulomb explosion of molecules. Retrieving molecular structures from these distributions poses a highly non-linear inverse problem that remains unsolved for molecules consisting of more than a few atoms. Here, we address this challenge using a diffusion-based Transformer neural network. We show that the network reconstructs unknown molecular geometries from ion-momentum distributions with a mean absolute error below one Bohr radius, which is half the length of a typical chemical bond.

Artificial Intelligence (cs.AI)↗

Stochastic growth logistic model with aftereffect for batch fermentation process

In this paper, the stochastic growth logistic model with aftereffect for the cell growth of C. acetobutylicum P262 and Luedeking-Piret equations for solvent production in batch fermentation system is introduced. The parameters values of the mathematical models are estimated via Levenberg-Marquardt optimization method of non-linear least squares. We apply Milstein scheme for solving the stochastic models numerically. The effciency of mathematical models is measured by comparing the simulated result and the experimental data of the microbial growth and solvent production in batch system. Low values of Root Mean-Square Error (RMSE) of stochastic models with aftereffect indicate good fits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental demonstration of nonlocal effects in the partial-collapse measurement and reversal process

We demonstrate experimentally the nonlocal reversal of a partial-collapse quantum measurement of a two-photon entangled state. Both the partial-collapse measurement and the reversal operation are implemented in linear optics with two displaced Sagnac interferometers, characterized by single-qubit quantum-process tomography. The recovered state is measured by quantum-state tomography, and its nonlocality is characterized by testing the Bell inequality. Our result will be helpful in quantum communication and quantum error correction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamic-Feature Extraction, Attribution and Reconstruction (DEAR) Method for Power System Model Reduction

In interconnected power systems, dynamic model reduction can be applied on generators outside the area of interest to mitigate the computational cost with transient stability studies. This paper presents an approach of deriving the reduced dynamic model of the external area based on dynamic response measurements, which comprises of three steps, dynamic-feature extraction, attribution and reconstruction (DEAR). In the DEAR approach, a feature extraction technique, such as singular value decomposition (SVD), is applied to the measured generator dynamics after a disturbance. Characteristic generators are then identified in the feature attribution step for matching the extracted dynamic features with the highest similarity, forming a suboptimal ‘basis’ of system dynamics. In the reconstruction step, generator state variables such as rotor angles and voltage magnitudes are approximated with a linear combination of the characteristic generators, resulting in a quasi-nonlinear reduced model of the original external system. Network model is un-changed in the DEAR method. Tests on several IEEE standard systems show that the proposed method gets better reduction ratio and response errors than the traditional coherency aggregation methods.

Dynamic response, model reduction, orthogonal deco↗

TH-AB-207A-11: Anatomical and Functional Assessment of Coronary Artery Disease Using Low-Dose Whole-Organ Dynamic Computed Tomography

Purpose: To evaluate the accuracy of a low-dose, first-pass-analysis (FPA) dynamic computed tomography angiography and perfusion (CTAP) technique, for whole-organ anatomical and functional assessment of coronary artery disease (CAD). Methods: An angioplasty balloon was advanced into the left anterior descending (LAD) coronary artery of five swine (35–45 kg) to induce several levels of stenosis at maximal hyperemia (intracoronary adenosine, 240 µg/min). Reference fluorescence microspheres and intravenous contrast (370 mg/mL iodine, 25 mL, 7 mL/s) were injected centrally and dynamic imaging was performed using a 320-slice CT scanner at 100 kVp and 200 mA. Twenty volume scans were acquired per stenosis level to capture complete aortic and myocardial enhancement curves, but only two volume scans were used for whole-organ dynamic FPA CTAP measurement. All CTAP measurements in the LAD were compared to the reference microsphere perfusion measurements using linear regression, concordance correlation, and Bland-Altman analysis. Results: The result of dynamic FPA CTAP measurement in the LAD was in good agreement with the reference microsphere perfusion measurement (P-CTAP = 1.01 P-MICRO + 0.16, R{sup 2} = 0.95). The root mean square error (RMSE) and difference (RMSD) of measurement were 0.51 mL/min/g and 0.47 mL/min/g, respectively. Bland-Altman analysis demonstrated negligible systematic measurement bias. Additionally, the concordance correlation coefficient (CCC) was found to be ρ = 0.97, indicating excellent agreement between dynamic FPA CTAP measurement and the reference microsphere perfusion measurement. Lastly, the effective dose of the proposed technique using the “simulated” two-volume scan CTAP acquisition protocol was 2.6 mSv; much lower than the ∼10 mSv effective dose of current dynamic CTP techniques alone. Conclusion: The results indicate the potential for significant improvements in CAD assessment through low-dose, quantitative dynamic FPA CTAP. Such improvements are afforded through whole-organ CT scanning technology, and have the potential to improve patient outcomes and lead to healthier patient lives. Conflict of Interest (only if applicable): Grant funding from Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

Connecting the Light Curves of Type IIP Supernovae to the Properties of Their Progenitors

Abstract Observations of core-collapse supernovae (CCSNe) reveal a wealth of information about the dynamics of the supernova ejecta and its composition but very little direct information about the progenitor. Constraining properties of the progenitor and the explosion requires coupling the observations with a theoretical model of the explosion. Here we begin with the CCSN simulations of Couch et al., which use a nonparametric treatment of the neutrino transport while also accounting for turbulence and convection. In this work we use the SuperNova Explosion Code to evolve the CCSN hydrodynamics to later times and compute bolometric light curves. Focusing on Type IIP SNe (SNe IIP), we then (1) directly compare the theoretical STIR explosions to observations and (2) assess how properties of the progenitor’s core can be estimated from optical photometry in the plateau phase alone. First, the distribution of plateau luminosities ( L 50 ) and ejecta velocities achieved by our simulations is similar to the observed distributions. Second, we fit our models to the light curves and velocity evolution of some well-observed SNe. Third, we recover well-known correlations, as well as the difficulty of connecting any one SN property to zero-age main-sequence mass. Finally, we show that there is a usable, linear correlation between iron core mass and L 50 such that optical photometry alone of SNe IIP can give us insights into the cores of massive stars. Illustrating this by application to a few SNe, we find iron core masses of 1.3–1.5 M ⊙ with typical errors of 0.05 M ⊙ . Data are publicly available online on Zenodo: doi: 10.5281/zenodo.6631964 .

79 ASTRONOMY AND ASTROPHYSICS↗

Neural network-based single material beam-hardening correction for X-ray CT in Additive Manufacturing

Beam-hardening (BH) artifacts are ubiquitous in X-ray CT scans of dense metal additively manufactured (AM) parts. While linearization approaches are useful for correcting beam-hardened data from single material objects, they either require a calibration scan or detailed system and material composition information. In this paper, we introduce a neural network-based, material-agnostic method to correct beam-hardening artifacts. We train a neural network to map the acquired beam-hardened projection values and the corresponding estimated thickness of the part based on an initial segmentation to beam-hardening related parameters, which can be used to compute the coefficients of a linearizing correction polynomial. A key strength of our approach is that, once the network is trained, it can be used for correcting beam hardening from a variety of materials without any calibration scans or detailed system and material composition information. Furthermore, our method is robust to errors in the estimated thickness due to the typical challenge of obtaining an accurate initial segmentation from reconstructions impacted by BH artifacts. We demonstrate the utility of our method to obtain high-quality CT reconstructions from a collection of AM parts -- suppressing cupping and streaking artifacts

Rahman, Obaid↗

Quantitative analysis of Cu XANES spectra using linear combination fitting of binary mixtures simulated by FEFF9

We report x-ray absorption near edge structure (XANES) is a powerful tool to probe the fingerprint of local structures, and when coupled with X-ray microscopy, the small spot size enables one to probe very specific regions of interest in a device or material, e.g. interfaces/bulk, different grains, good/bad electrical areas. In this work, we investigate the use of linear combination fitting (LCF) of XANES spectra for the particular case of Cu doping in CdTe. We show that the experimental data seem to be accurately represented by standards of Cu 2 Te and its substoichiometric counterpart, Cu 1.43 Te. We use Cu in CdTe as a case study to evaluate the accuracy of linear combination fitting using simulated standards, given that experimental standards for certain phases (e.g. Cu 1.43 Te) or defect structures (e.g. vacancies) cannot be readily obtained. We discuss how spectral features of the FEFF9-simulated standards, fitting ranges, and noise levels all dictate the accuracy of this type of analysis. We show that the greater the spectral difference between the two standards, the better the LCF is able to differentiate between the two structures and to tolerate experimental noise. Finally, we estimate the error of the fitted weights for different spectral features and noise levels and propose a framework to study local structures semi-quantitatively by using binary mixtures of FEFF9-simulated standards.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

U-net architected deep material network training with microstructure local field information

The Deep Material Network (DMN) has recently emerged as a powerful reduced-order modeling framework for simulating the mechanical response of heterogeneous materials such as composites. Unlike most data-driven approaches that directly learn a material’s response under prescribed loading, the DMN acts as a homogenization operator, learning the kinematic constraints and mechanical interactions of the underlying microstructure. However, traditional DMN training relies exclusively on homogenized effective properties derived from Direct Numerical Simulations (DNS), discarding the rich local field data that govern microstructural interactions. In this work, we extend the DMN framework to incorporate such local field information into the offline training process. Utilizing a U-Net architecture, we augment the DMN training objective to include the first and second statistical moments of the local stress fields obtained from linear DNS. This ensures that the learned network topology not only fits the effective stiffness but also accurately reflects the internal local stress and strain partitioning of the microstructure. The results confirm that supervising the localization process during training yields a superior surrogate model, reducing local prediction errors by an order of magnitude and significantly improving generalization to unseen nonlinear constitutive behaviors compared to traditional DMNs.

36 MATERIALS SCIENCE↗

Mechanical Behavior of Lead at High Strain Rates

This paper presents a study on the material behaviors and constitutive models of lead at high strain rates. Quasi-static compressive tests and split Hopkinson pressure bar (SHPB) tests were conducted at room temperature. The results of the SHPB tests were verified by high-speed photography, and the error of strain is less than 3% at high strain rate (5000/s). Our results show that the yield stress and flow stress increase at high strain rates. This result indicates that lead is sensitive to the strain rate at high strain rates, but the dependence is not linear during 3000-5000/s. The strain-rate dependence of lead was fitted by a quadratic polynomial curve. To describe the nonlinear strain-rate relationship of lead, modified Johnson–Cook and Cowper–Symonds material models were used to fit the experimental stress–strain curves. The modified Cowper–Symonds model agrees better with the experimental results and can better describe the dynamic mechanical behavior of lead under high strain rates.

36 MATERIALS SCIENCE↗

Airborne Lidar Measurements of XCO 2 in Synoptically Active Environment and Associated Comparisons With Numerical Simulations

Frontal boundaries have been shown to cause large changes in CO 2 mole-fractions, but clouds and the complex vertical structure of fronts make these gradients difficult to observe. It remains unclear how the column average CO 2 dry air mole-fraction (XCO 2 ) changes spatially across fronts, and how well airborne lidar observations, data assimilation systems, and numerical models without assimilation capture XCO 2 frontal contrasts (ΔXCO 2 , i.e., warm minus cold sector average of XCO 2 ). We demonstrated the potential of airborne Multifunctional Fiber Laser Lidar (MFLL) measurements in heterogeneous weather conditions (i.e., frontal environment) to investigate the ΔXCO 2 during four seasonal field campaigns of the Atmospheric Carbon and Transport-America (ACT-America) mission. Most frontal cases in summer (winter) reveal higher (lower) XCO 2 in the warm (cold) sector than in the cold (warm) sector. During the transitional seasons (spring and fall), no clear signal in ΔXCO 2 was observed. Intercomparison among the MFLL, assimilated fields from NASA's Global Modeling and Assimilation Office (GMAO), and simulations from the Weather Research and Forecasting-—Chemistry (WRF-Chem) showed that (a) all products had a similar sign of ΔXCO 2 though with different levels of agreement in ΔXCO 2 magnitudes among seasons; (b) ΔXCO 2 in summer decreases with altitude; and (c) significant challenges remain in observing and simulating XCO 2 frontal contrasts. A linear regression analyses between ΔXCO 2 for MFLL versus GMAO, and MFLL versus WRF-Chem for summer-2016 cases yielded a correlation coefficient of 0.95 and 0.88, respectively. The reported ΔXCO 2 variability among four seasons provide guidance to the spatial structures of XCO 2 transport errors in models and satellite measurements of XCO 2 in synoptically-active weather systems.

54 ENVIRONMENTAL SCIENCES↗

Autopilot for frequency-modulation atomic force microscopy

One of the most challenging aspects of operating an atomic force microscope (AFM) is finding optimal feedback parameters. This statement applies particularly to frequency-modulation AFM (FM-AFM), which utilizes three feedback loops to control the cantilever excitation amplitude, cantilever excitation frequency, and z-piezo extension. These loops are regulated by a set of feedback parameters, tuned by the user to optimize stability, sensitivity, and noise in the imaging process. Optimization of these parameters is difficult due to the coupling between the frequency and z-piezo feedback loops by the non-linear tip-sample interaction. Four proportional-integral (PI) parameters and two lock-in parameters regulating these loops require simultaneous optimization in the presence of a varying unknown tip-sample coupling. Presently, this optimization is done manually in a tedious process of trial and error. Here, we report on the development and implementation of an algorithm that computes the control parameters automatically. The algorithm reads the unperturbed cantilever resonance frequency, its quality factor, and the z-piezo driving signal power spectral density. It analyzes the poles and zeros of the total closed loop transfer function, extracts the unknown tip-sample transfer function, and finds four PI parameters and two lock-in parameters for the frequency and z-piezo control loops that optimize the bandwidth and step response of the total system. Implementation of the algorithm in a home-built AFM shows that the calculated parameters are consistently excellent and rarely require further tweaking by the user. The new algorithm saves the precious time of experienced users, facilitates utilization of FM-AFM by casual users, and removes the main hurdle on the way to fully automated FM-AFM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗