Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Synthesis of poly(aniline-co-o-toluidine) coatings on copper

The corrosion protective poly(aniline-co-o-toluidine) (PAOT) coatings were synthesized on copper (Cu) by the electrochemical copolymerization of aniline with o-toluidine under cyclic voltammetry conditions. Aqueous oxalate solutions were used as the supporting electrolytes for the synthesis of PAOT coatings on Cu. The resulting coatings were characterized by different spectroscopic techniques, cyclic voltammetry, ultraviolet-visible absorption spectroscopy, Fourier transform infrared spectroscopy (FTIR), nuclear magnetic resonance spectroscopy (NMR), and scanning electron microscopy. The Fourier Transform InfraRed (FTIR) spectroscopy and Nuclear Magnetic Resonance (NMR) spectroscopy studies reveal that the copolymerization of aniline and o-toluidine takes place on Cu substrates from an aqueous oxalate solutions and resulting in PAOT copolymer, there are more o-toluidine units than aniline units.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorine sites in glasses and transparent glass-ceramics of the system Na{sub 2}O/K{sub 2}O/Al{sub 2}O{sub 3}/SiO{sub 2}/BaF{sub 2}

The transparent glass-ceramics obtained in the silicate system Na{sub 2}O/K{sub 2}O/SiO{sub 2}/BaF{sub 2} show homogeneously dispersed BaF{sub 2} nano crystals with a narrow size distribution. The X-ray diffraction and the nuclear magnetic resonance spectroscopy were applied to glasses and the respective glass-ceramics in order to clarify the crystallization mechanism and the role of fluorine during crystallization. With an increasing annealing time, the concentration and also the number of crystals remain approximately constant. With an increasing annealing temperature, the crystalline fraction increases until a saturation limit is reached, while the number of crystals decreases and the size of the crystals increases. Fluoride in the glassy network occurs as Al-F-Ba, Al-F-Na and also as Ba-F structures. The latter are transformed into crystalline BaF{sub 2} and fluoride is removed from the Al-F-Ba/Na bonds. However, some fluorine is still present in the glassy phase after the crystallization. -- Graphical abstract: The X-ray diffraction and the nuclear magnetic resonance spectroscopy were applied to glasses in the silicate system Na{sub 2}O/K{sub 2}O/SiO{sub 2}/BaF{sub 2} and the respective glass-ceramics with BaF{sub 2} nano crystals in order to clarify the crystallization mechanism and the role of fluorine during crystallization. Display Omitted Research highlights: {yields} BaF{sub 2} nano crystals are precipitated from a silicate glass system. {yields} Ostwald ripening during the late stage of crystallization does not occur. {yields} Fluorine in the glass is coordinated with Ba as well as Al together with Ba or Na.{yields} In the glass-ceramics, the residual fluorine is coordinated as Al-F-Ba/Na.

36 MATERIALS SCIENCE↗

Predicting Post-External Beam Radiation Therapy PSA Relapse of Prostate Cancer Using Pretreatment MRI

Purpose: To investigate whether pretreatment endorectal magnetic resonance imaging (MRI) findings can predict biochemical relapse in patients with clinically localized prostate cancer treated with external beam radiation therapy (EBRT). Methods and Materials: Between January 2000 and January 2002, 224 patients (median age, 69 years; age range, 45-82 years) with biopsy-proven prostate cancer underwent endorectal MRI before high-dose ({>=}81Gy) EBRT. The value of multiple clinical and MRI variables in predicting prostate-specific antigen (PSA) relapse at 5 years was determined by use of univariate and multivariate stepwise Cox regression. Clinical variables included pretreatment PSA, clinical T stage, Gleason score, use of neoadjuvant hormonal therapy, and radiation dose. Magnetic resonance imaging variables, derived from retrospective consensus readings by two radiologists, were used to measure intraprostatic and extraprostatic tumor burden. Results: After a median follow-up of 67 months, PSA relapse developed in 37 patients (16.5%). The significant predictors of PSA relapse on univariate analysis were pretreatment PSA, clinical T stage, and multiple MRI variables, including MRI TN stage score; extracapsular extension (ECE) status; number of sextants involved by ECE, all lesions, or index (dominant) lesion; apical involvement; and diameter and volume of index lesion. Pretreatment PSA and ECE status were the only significant independent predictors on multivariate analysis (p < 0.05 for both). Extracapsular extension status was associated with the highest hazard ratio, 3.04; 5-year PSA relapse rates were 7% for no ECE, 20% for unilateral ECE, and 48% for bilateral ECE. Conclusions: Magnetic resonance imaging findings can be used to predict post-EBRT PSA relapse, with ECE status on MRI and pretreatment PSA being significant independent predictors of this endpoint.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Changes Mimicking New Leptomeningeal Disease After Intensity-Modulated Radiotherapy for Medulloblastoma

Purpose: Acute and late changes in magnetic resonance imaging of the pediatric brain have been described after radiotherapy (RT). We report the post-RT neuroimaging changes in the posterior fossa after intensity-modulated RT (IMRT) in children with medulloblastoma and contrast them with those of leptomeningeal disease. Methods and Materials: We performed a retrospective review of 53 consecutive children with medulloblastoma who were treated with craniospinal RT followed by IMRT to the posterior fossa and chemotherapy between 1997 and 2006. Results: After IMRT to the posterior fossa, 8 (15%) of 53 patients developed increased fluid-attenuated inversion-recovery signal changes in the brainstem or cerebellum and patchy, multifocal, nodular contrast enhancement at a median of 6 months. The enhancement superficially resembled leptomeningeal disease. However, the enhancement resolved without intervention at a median of 6 months later. The accompanying fluid-attenuated inversion-recovery signal changes occasionally preceded the enhancement, were often parenchymal in location, and resolved or persisted to a lesser degree. All 8 patients with transient magnetic resonance imaging changes in the posterior fossa were alive at last follow-up. In contrast, leptomeningeal disease occurred in 8 (15%) of our 53 patients at a median of 19.5 months after IMRT completion. Of these 8 patients, 7 demonstrated initial nodular enhancement outside the conformal field, and 7 patients died. Conclusion: Magnetic resonance imaging changes can occur in the posterior fossa of children treated with IMRT for medulloblastoma. In our experience, these transient changes occur at a characteristic time and location after RT, allowing them to be distinguished from leptomeningeal disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generalized theory of double-resonance optical pumping of {sup 4}He

We present extensions to the theory of double-resonance laser pumping of {sup 4}He in the context of magnetometer instrumentation. This extended theory allows for arbitrary optical polarization, magnetic resonance (H{sub 1}) coil orientation, and overall instrument orientation relative to the ambient magnetic field. Steady-state solutions are presented for portions of the extended parameter space. These calculations are used to analyze the shot-noise-limited sensitivities for helium magnetometers for selected parameter values, and we find that linearly polarized light can have a relatively simple orientational dependence for a particular choice of angle between the H{sub 1} coils and the light polarization vector. Calculations are also compared to experimentally measured magnetic resonance curves, and a shot-noise limit on sensitivity of 6 fT/{radical}(Hz) is determined for a particular magnetometer apparatus using a cell 2.4 cm in diameter and 7.5 cm in length. This extended theory can be utilized to select optimal operational parameter values and obtain ideal sensitivities for helium magnetometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic properties and hyperfine interactions in Cr{sub 8}, Cr{sub 7}Cd, and Cr{sub 7}Ni molecular rings from {sup 19}F-NMR

A detailed experimental investigation of the {sup 19}F nuclear magnetic resonance is made on single crystals of the homometallic Cr{sub 8} antiferromagnetic molecular ring and heterometallic Cr{sub 7}Cd and Cr{sub 7}Ni rings in the low temperature ground state. Since the F{sup −} ion is located midway between neighboring magnetic metal ions in the ring, the {sup 19}F-NMR spectra yield information about the local electronic spin density and {sup 19}F hyperfine interactions. In Cr{sub 8}, where the ground state is a singlet with total spin S{sub T} = 0, the {sup 19}F-NMR spectra at 1.7 K and low external magnetic field display a single narrow line, while when the magnetic field is increased towards the first level crossing field, satellite lines appear in the {sup 19}F-NMR spectrum, indicating a progressive increase in the Boltzmann population of the first excited state S{sub T} = 1. In the heterometallic rings, Cr{sub 7}Cd and Cr{sub 7}Ni, whose ground state is magnetic with S{sub T} = 3/2 and S{sub T} = 1/2, respectively, the {sup 19}F-NMR spectrum has a complicated structure which depends on the strength and orientation of the magnetic field, due to both isotropic and anisotropic transferred hyperfine interactions and classical dipolar interactions. From the {sup 19}F-NMR spectra in single crystals we estimated the transferred hyperfine constants for both the F{sup −}-Ni{sup 2+} and the F{sup −}-Cd{sup 2+} bonds. The values of the hyperfine constants compare well to the ones known for F{sup −}-Ni{sup 2+} in KNiF{sub 3} and NiF{sub 2} and for F{sup −}-Cr{sup 3+} in K{sub 2}NaCrF{sub 6}. The results are discussed in terms of hybridization of the 2s, 2p orbitals of the F{sup −} ion and the d orbitals of the magnetic ion. Finally, we discuss the implications of our results for the electron-spin decoherence.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MRI-Guided 3D Optimization Significantly Improves DVH Parameters of Pulsed-Dose-Rate Brachytherapy in Locally Advanced Cervical Cancer

Purpose: To compare dose-volume histogram parameters of standard Point A and magnetic resonance imaging-based three-dimensional optimized dose plans in 21 consecutive patients who underwent pulsed-dose-rate brachytherapy (PDR-BT) for locally advanced cervical cancer. Methods and Materials: All patients received external beam radiotherapy (elective target dose, 45 Gy in 25-30 fractions; tumor target dose, 50-60 Gy in 25-30 fractions). PDR-BT was applied with a tandem-ring applicator. Additional ring-guided titanium needles were used in 4 patients and a multichannel vaginal cylinder in 2 patients. Dose planning was done using 1.5 Tesla T{sub 1}-weighted and T{sub 2}-weighted paratransversal magnetic resonance imaging scans. T{sub 1}-weighted visible oil-containing tubes were used for applicator reconstruction. The prescribed standard dose for PDR-BT was 10 Gy (1 Gy/pulse, 1 pulse/h) for two to three fractions to reach a physical dose of 80 Gy to Point A. The total dose (external beam radiotherapy plus brachytherapy) was normalized to an equivalent dose in 2-Gy fractions using {alpha}/{beta} = 10 Gy for tumor, {alpha}/{beta} = 3 Gy for normal tissue, and a repair half-time of 1.5 h. The goal of optimization was dose received by 90% of the target volume (D{sub 90}) of {>=}85 Gy{sub {alpha}}{sub /{beta}}{sub 10} in the high-risk clinical target volume (cervix and remaining tumor at brachytherapy), but keeping the minimal dose to 2 cm{sup 3} of the bladder and rectum/sigmoid at <90 and <75 Gy{sub {alpha}}{sub /{beta}}{sub 3}, respectively. Results: Using three-dimensional optimization, all dose-volume histogram constraints were met in 16 of 21 patients compared with 3 of 21 patients with two-dimensional library plans (p < 0.001). Optimization increased the minimal target dose (D{sub 100}) of the high-risk clinical target volume (p < 0.007) and decreased the minimal dose to 2 cm{sup 3} for the sigmoid significantly (p = 0.03). For the high-risk clinical target volume, D{sub 90} was 91 {+-} 8 Gy{sub {alpha}}{sub /{beta}}{sub 10} and D{sub 100} was 76 {+-} 5 Gy{sub {alpha}}{sub /{beta}}{sub 10}. The minimal dose to 2 cm{sup 3} for the bladder, rectum, and sigmoid was 73 {+-} 6, 67 {+-} 6, and 69 {+-} 6 Gy{sub {alpha}}{sub /{beta}}{sub 3}, respectively. Conclusion: The results of our study have shown that magnetic resonance imaging-guided optimization of PDR-BT for locally advanced cervical cancer significantly improved the dose-volume histogram parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A peripheral component interconnect express-based scalable and highly integrated pulsed spectrometer for solution state dynamic nuclear polarization

High sensitivity, high data rates, fast pulses, and accurate synchronization all represent challenges for modern nuclear magnetic resonance spectrometers, which make any expansion or adaptation of these devices to new techniques and experiments difficult. Here, we present a Peripheral Component Interconnect Express (PCIe)-based highly integrated distributed digital architecture pulsed spectrometer that is implemented with electron and nucleus double resonances and is scalable specifically for broad dynamic nuclear polarization (DNP) enhancement applications, including DNP-magnetic resonance spectroscopy/imaging (DNP-MRS/MRI). The distributed modularized architecture can implement more transceiver channels flexibly to meet a variety of MRS/MRI instrumentation needs. The proposed PCIe bus with high data rates can significantly improve data transmission efficiency and communication reliability and allow precise control of pulse sequences. An external high speed double data rate memory chip is used to store acquired data and pulse sequence elements, which greatly accelerates the execution of the pulse sequence, reduces the TR (time of repetition) interval, and improves the accuracy of TR in imaging sequences. Using clock phase-shift technology, we can produce digital pulses accurately with high timing resolution of 1 ns and narrow widths of 4 ns to control the microwave pulses required by pulsed DNP and ensure overall system synchronization. The proposed spectrometer is proved to be both feasible and reliable by observation of a maximum signal enhancement factor of approximately −170 for {sup 1}H, and a high quality water image was successfully obtained by DNP-enhanced spin-echo {sup 1}H MRI at 0.35 T.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures

Natural organic matter (NOM) is composed of a highly complex mixture of thousands of organic compounds which, historically, proved difficult to characterize. However, to understand the thermodynamic and kinetic controls on greenhouse gas (carbon dioxide [CO 2 ] and methane [CH 4 ]) production resulting from the decomposition of NOM, a molecular-level characterization coupled with microbial proteome analyses is necessary. Further, climate and environmental changes are expected to perturb natural ecosystems, potentially upsetting complex interactions that influence both the supply of organic matter substrates and the microorganisms performing the transformations. A detailed molecular characterization of the organic matter, microbial proteomics, and the pathways and transformations by which organic matter is decomposed will be necessary to predict the direction and magnitude of the effects of environmental changes. This article describes a methodological throughput for comprehensive metabolite characterization in a single sample by direct injection Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS), gas chromatography mass spectrometry (GC-MS), nuclear magnetic resonance (NMR) spectroscopy, liquid chromatography mass spectrometry (LC-MS), and proteomics analysis. Furthermore, this approach results in a fully-paired dataset which improves statistical confidence for inferring pathways of organic matter decomposition, the resulting CO 2 and CH 4 production rates, and their responses to environmental perturbation. Herein we present results of applying this method to NOM samples collected from peatlands; however, the protocol is applicable to any NOM sample (e.g., peat, forested soils, marine sediments, etc.).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-Step Conversion of Ethanol to n-Butene over Ag-ZrO2/SiO2 Catalysts

Ethanol is a promising platform molecule for production of a variety of fuels and chemicals. Of particular interest is producing middle distillate fuels (i.e., jet and diesel blendstock) from renewable ethanol feedstock. State-of-the-art alcohol-to-jet technology requires multiple process steps based on catalytic dehydration of ethanol to form ethylene, followed by sometimes a multi-step oligomerization, and then hydrotreatment and distillation. Here we report on a new catalytic route in which ethanol is directly converted to n-butene (1- and 2-butene mixtures) over Ag-ZrO2/SBA-16, thus offering the potential for a reduction in the number of required processing steps versus conventional alcohol-to-jet technology. This catalyst system provides the balanced metal and Lewis acid sites required to selectively facilitate a cascading sequence of reactions that includes dehydrogenation, aldol condensation, Meerwein–Ponndorf–Verley reduction, dehydration, and hydrogenation. High conversion and selectivity toward either n-butene or 1,3-butadiene is achieved by tuning the hydrogen feed partial pressure and other process/catalyst parameters. With sufficient hydrogen partial pressure 1,3-butadiene is completely and selectively hydrogenated to form n-butene. The reaction mechanism was elucidated through operando-nuclear magnetic resonance investigations coupled with reactivity measurements. Combined experimental-computational investigation reveals how changes in silver and zirconium composition and the silver oxidation state affects reactivity under controlled hydrogen partial pressures and after prolonged run times. Finally, catalyst effectiveness also was demonstrated when using wet ethanol feed, thus highlighting process flexibility in terms of feedstock purity requirements. This work was financially supported by the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy, Bioenergy Technologies Office, and was performed at the Pacific Northwest National Laboratory (PNNL) under Contract No. DE-AC05-76RL01830 and the National Renewable Energy Laboratory under Contract No. DE-AC36- 08GO28308. Part of the work conducted by S. A. Akhade was performed under the auspices of the U.S. DOE at Lawrence Livermore National Laboratory under Contract No. DE-AC52-07NA27344. This work was partly supported through the PNNL-WSU Distinguished Graduate Research Program for ADW. NMR and XPS experiments were performed using EMSL (grid.436923.9), a DOE Office of Science User Facility sponsored by the Office of Biological and Environmental Research

Dagle, Vanessa↗

Suppression of MHD modes with active phase-control of probe-injected currents

Abstract Active phase-control of probe-injected current is shown to both suppress and amplify long-wavelength rotating magnetohydrodynamic instabilities in the HBT-EP tokamak. Four probes are connected in quadrature and energized to drive non-axisymmetric currents through the edge of the tokamak, creating magnetic perturbations comparable to previously-studied saturated kink modes or resonant magnetic perturbations that are generated by an external control coil array. Measurements of the magnetic perturbations from the probe-injected currents determine a set of current-carrying helical filaments used to model active feedback control of resistive wall modes. These experiments suggest current-injection feedback may be an effective alternative to external control coils for control of RWMs and other long-wavelength kink-like modes at the edge of tokamaks.

Physics↗

M3D-C1 simulations of the plasma response to RMPs in NSTX-U single-null and snowflake divertor configurations

Here in this work, single- and two-fluid resistive magnetohydrodynamic calculations of the plasma response to n = 3 magnetic perturbations in single-null (SN) and snowflake (SF) divertor configurations are compared with those based on the vacuum approach. The calculations are performed using the code M3D-C 1 and are based on simulated NSTX-U plasmas. Significantly different plasma responses were found from these calculations, with the difference between the single- and two-fluid plasma responses being caused mainly by the different screening mechanism intrinsic to each of these models. Although different plasma responses were obtained from these different plasma models, no significant difference between the SN and SF plasma responses were found. However, due to their different equilibrium properties, magnetic perturbations cause the SF configuration to develop additional and longer magnetic lobes in the null-point region than the SN, regardless of the plasma model used. The intersection of these longer and additional lobes with the divertor plates are expected to cause more striations in the particle and heat flux target profiles. In addition, the results indicate that the size of the magnetic lobes, in both single-null and snowflake configurations, are more sensitive to resonant magnetic perturbations than to non-resonant magnetic perturbations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

M3D-C1 simulations of the plasma response to RMPs in NSTX-U single-null and snowflake divertor configurations

Non-axisymmetric control coils and the so-called snowflake divertor configuration are two potential solutions proposed to solve two separate outstanding issues on the path towards self-sustained burning plasma operations, namely the transient energy bursts caused by edge localized modes and the steady state heat exhaust problem. In a reactor, these two proposed solutions would have to operate simultaneously and it is, therefore, important to investigate their compatibility and to identify possible conflicts that could prevent them from operating simultaneously. In this work, single- and two-fluid resistive magnetohydrodynamic calculations are used to investigate the effect of externally applied magnetic perturbations on the snowflake divertor configuration. The calculations are based on simulated NSTX-U plasmas and the results show that additional and longer magnetic lobes are created in the null-point region of the snowflake configuration, compared to those in the conventional single-null. The intersection of these longer and additional lobes with the divertor plates are expected to cause more striations in the particle and heat flux target profiles. In addition, the results indicate that the size of the magnetic lobes, in both single-null and snowflake configurations, are more sensitive to resonant magnetic perturbations than to non-resonant magnetic perturbations. The results also suggest that lower values of current in non-axisymmetric control coils would be required to suppress edge localized modes in plasmas with the snowflake configuration.

Snowflake divertor Plasma response Two fluid MHD N↗

Identification and control of the exhaust using gas perturbations in the DIII-D tokamak

This paper presents perturbative experiments that enable the validation and development of control-oriented models for exhaust control. We identify the response of the divertor plasma and scrape-off layer in the DIII-D tokamak to deuterium and nitrogen multi-sine perturbations, in favorable and unfavorable field directions for H-mode access. We obtained good signal-to-noise ratios in the 1–10 Hz frequency range by measuring Balmer-alpha, Lyman-alpha, and N 4+ line emission, radiated power, and neutral pressure. We find a similar phase response across gas species and magnetic field directions, while the gain response is nonlinear. With these experiments, we identify a control-oriented model to design a divertor radiated power controller to track specified reference waveforms in conjunction with resonant magnetic perturbations. Although the physics basis for compatibility between detachment and resonant magnetic perturbation edge-localized mode suppression remains to be demonstrated, the present results provide a robust controller that represents a promising step toward future joint control strategies.

detachment control↗

Study of the interplay between magnetic shear and resonances using Hamiltonian models for the magnetic field lines

The issue of magnetic confinement in magnetic fusion devices is addressed within a purely magnetic approach. Using some Hamiltonian models for the magnetic field lines, the dual impact of low magnetic shear is shown in a unified way. Away from resonances, it induces a drastic enhancement of magnetic confinement that favors robust internal transport barriers (ITBs) and stochastic transport reduction. When low shear occurs for values of the winding of the magnetic field lines close to low-order rationals, the amplitude thresholds of the resonant modes that break internal transport barriers by allowing a radial stochastic transport of the magnetic field lines may be quite low. The approach can be applied to assess the robustness versus magnetic perturbations of general (almost) integrable magnetic steady states, including nonaxisymmetric ones such as the important single-helicity steady states. This analysis puts a constraint on the tolerable mode amplitudes compatible with ITBs and may be proposed as a possible explanation of diverse experimental and numerical signatures of their collapses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MRI of Heterogeneous Hydrogenation Reactions Using Parahydrogen Polarization

The power of magnetic resonance imaging (MRI) is its ability to image the internal structure of optically opaque samples and provide detailed maps of a variety of important parameters, such as density, diffusion, velocity and temperature. However, one of the fundamental limitations of this technique is its inherent low sensitivity. For example, the low signal to noise ratio (SNR) is particularly problematic for imaging gases in porous materials due to the low density of the gas and the large volume occluded by the porous material. This is unfortunate, as many industrially relevant chemical reactions take place at gas-surface interfaces in porous media, such as packed catalyst beds. Because of this severe SNR problem, many techniques have been developed to directly increase the signal strength. These techniques work by manipulating the nuclear spin populations to produce polarized} (i.e., non-equilibrium) states with resulting signal strengths that are orders of magnitude larger than those available at thermal equilibrium. This dissertation is concerned with an extension of a polarization technique based on the properties of parahydrogen. Specifically, I report on the novel use of heterogeneous catalysis to produce parahydrogen induced polarization and applications of this new technique to gas phase MRI and the characterization of micro-reactors. First, I provide an overview of nuclear magnetic resonance (NMR) and how parahydrogen is used to improve the SNR of the NMR signal. I then present experimental results demonstrating that it is possible to use heterogeneous catalysis to produce parahydrogen-induced polarization. These results are extended to imaging void spaces using a parahydrogen polarized gas. In the second half of this dissertation, I demonstrate the use of parahydrogen-polarized gas-phase MRI for characterizing catalytic microreactors. Specifically, I show how the improved SNR allows one to map parameters important for characterizing the heat and mass transport in a heterogeneous catalyst bed. This is followed by appendices containing detailed information regarding the design and use of my experimental setup.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low temperature spin dynamics in Cr{sub 7}Ni-Cu-Cr{sub 7}Ni coupled molecular rings

Proton Nuclear Magnetic Resonance (NMR) relaxation measurements have been performed down to very low temperature (50 mK) to determine the effect of coupling two Cr{sub 7}Ni molecular rings via a Cu{sup 2+} ion. No difference in the spin dynamics was found from nuclear spin lattice relaxation down to 1.5 K. At lower temperature, the {sup 1}H-NMR line broadens dramatically indicating spin freezing. From the plot of the line width vs. magnetization, it is found that the freezing temperature is higher (260 mK) in the coupled ring with respect to the single Cr{sub 7}Ni ring (140 mK)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗