SEARCH · Search NASA
Results for “MITIGATION”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
An experimental and numerical study of wellbore leakage mitigation using pH-triggered polymer gelant
The potential leakage of hydrocarbon fluids or carbon dioxide from subsurface formations is a primary concern in wellbore integrity, oil and gas production, and CO 2 storage. Leaky wells with fractured cement or debonded microannuli are common sources of subsurface fluid leakage. The hydrocarbon fluid or CO 2 can migrate through such pathways to shallower formations and ultimately to surface. Cement fractures may have apertures on the order of microns, which are difficult to seal with typical workover techniques. A material that provides low viscosity during the injection but much higher viscosity after injection, with a minimum pressure gradient to yield flow at the target zone, is a potentially effective approach to seal the leakage pathways through cement fractures. pH-triggered polymers are such a material: aqueous solutions with low viscosity at low pH, containing pH-sensitive microgels which viscosify upon neutralization to become highly swollen gels with substantial yield stress that can block fluid flow. For the wellbore leakage application, the large alkalinity of wellbore cement provides the required neutralization. Our coreflood and rheological experiments show that pH-triggered polymer sealants such as polyacrylic acid polymer provide a robust seal if the process is properly designed; however, its long-term applicability depends on the dynamic geochemical environment of the wellbore. The process comprises three stages: (1) injection of a chelating agent as the preflush to ensure a favorable environment for the polymer gel, (2) injection of polymer solution, and (3) shut-in for the polymer gelation. A systematic study was done to understand the conditions under which the polymer gel remains stable and effectively seals the leakage pathways. A numerical model, based on polymer rheological properties and governing mechanisms observed in the laboratory experiments, was developed to simulate the reactive flow and transport of pH-triggered polymers in narrow fractures. Comparison with experiments shows a generally good agreement, despite the relative simplicity of the model. The numerical model was used to investigate further the underlying mechanisms of the process. The results can be used to design effectively the remediation process for a known fracture aperture size of the target zone.
Optimizing fluvial flood mitigation strategies: A multi-objective approach for cost-effective and socially-aware infrastructure feasibility analysis
Effective levee planning must balance capital cost, risk reduction, and community priorities. These objectives are rarely optimized together. This study presents a feasibility phase, simulationin-the-loop framework that couples terrain-based flood modeling with a socially aware multiobjective optimizer. Flood risk is measured as Expected Annual Exposed Population (EAEP), obtained by integrating exposure over Annual Exceedance Probability (AEP) nodes, mirroring the Hydrologic Engineering Center's Flood Damage Reduction Analysis (HEC-FDA) expected-annual formulation but with people rather than dollars. Exposure per scenario is computed by overlaying binary inundation masks with a population surface at the tract level. Distributional fairness is encoded through a Group Benefit Share (GBS) constraint that requires high-SVI tracts to receive at least a baseline share of annualized benefits. Capital cost is represented by a height-dependent unit-cost model suitable for screening. This study addresses the two-objective problem, minimize cost and expected annual exposure subject to the GBS constraint, using Non-Dominated Sorting Genetic Algorithm II (NSGA-II) and leveraging Pareto front for feasibility phase decision making. Implemented with terrain-based flood modeling, GeoFlood, for rapid scenario evaluation, the framework is demonstrated in Southeast Texas. The results reveal clear trade-offs among cost, risk, and social benefits and identify non-dominated levee height configurations that satisfy the benefit-share floor. The contributions are a scalable decision support method that operationalizes expected annual population-based risk, embeds enforceable benefit-sharing guarantees, and uses lightweight simulation to explore large design spaces before higher fidelity design stages.
Innovative duo-recombination layer design for effective hydrogen crossover mitigation in advanced MEAs for PEM water electrolyzers
Hydrogen crossover in proton exchange membrane water electrolyzers (PEMWEs) poses a safety hazard, reduces the overall efficiency, and limits the operational differential pressure range. Here, in this study, a membrane electrode assembly (MEA) with innovative Pt duo-recombination layer (DRL) design is developed by the unique reactive spray deposition technology (RSDT). The novel design comprises two thin RLs integrated within the volume of the membrane and has a total Pt loading of only 0.04 mg Pt cm −2 . Long-term durability test for over 3000 h is performed with as-fabricated MEA at steady-state conditions typical for an industrial hydrogen production system. The results from the durability test show that the newly developed DRL design effectively suppresses the H2 crossover to below 0.5 vol%. Furthermore, comprehensive post-test characterization of the MEA is performed and potential failure mechanisms in the Pt RLs observed during the durability test are identified and discussed in detail for the first time.
A non-aqueous sodium hexafluorophosphate-based electrolyte degradation study: Formation and mitigation of hydrofluoric acid
Fundamental characterization of battery electrolyte is crucial for rechargeable batteries. This work reports the chemical stability of sodium hexafluorophosphate (NaPF6)-based non-aqueous electrolytes containing different solvent mixtures (e.g., cyclic and acyclic carbonates) in the presence of water for Na-ion batteries. A degradation study is conducted using NaPF 6 -based electrolytes, highlighting the effect of two electrolyte additives, 2,2,2-trifluoroethoxy-2,2,2-ethoxy phosphazene (FM2) and fluoroethylene carbonate (FEC), on degradation and cell performance of full-cell Na-ion batteries. Hydrolysis of this salt in acidic condition is particularly prone to form hydrofluoric acid (HF), and can be observed in electrolytes made with battery grade carbonate solvents (<20 ppm of water). Here, degradation mechanisms of NaPF 6 -based electrolytes are studied using liquid nuclear magnetic resonance (NMR). Noticeable degradation takes place in high purity electrolytes with the presence of moisture to form HF and organophosphates in timeframes below the current shelf-life of the Na electrolytes. FEC is not efficient to protect the electrodes from being exposed to HF. On the other hand, FM2 is revealed as a “scavenger” of HF, which helps stabilize the shelf life of electrolytes that might contain or become exposed to water. Our study underscores the importance to understanding the degradation of electrolyte and improving stability toward better shelf life for sodium ion batteries.
Rapid implementation of mitigation measures can facilitate decarbonization of the global steel sector in 1.5°C-consistent pathways
Not Available
Assessment of the driving factors of CO 2 mitigation costs of household biogas systems in China: A LMDI decomposition with cost analysis model
China has been placing a substantial focus on biogas for reducing energy consumption and carbon dioxide (CO 2 ) emissions. The operation mode of biogas systems may make the CO 2 reduction target over-optimistic. There is limited research to investigate the influential factors that may be causing the gap between the actual and theoretical CO 2 reduction costs of biogas systems in China. In this research, by using field survey data of 209 biogas users and 489 non-biogas users from 19 villages in 2015, the gap between actual and theoretical unit CO 2 reduction cost is quantified at approximately 156 USD/t CO 2 . By employing the Logarithmic Mean Divisia Index I (LMDI) model, it is found that both the cost effect (48%) and the reduction effect (52%) contribute to the unit CO 2 reduction cost gap. Furthermore, four influential factors–household labor, accessibility to the energy resource, acceptance of biogas technology, and subsidy–significantly narrow the gap between actual and theoretical CO 2 reduction costs, while the levelized subsidy contributes to widening the gap. On average, biogas systems should be operated for at least four years and the substitution rate should be more than 67% in order to keep the gap between actual and theoretical CO 2 reduction costs under 50%.
Comprehensive Review of the Impact of Dust on the Use of Solar Energy: History, Investigations, Results, Literature, and Mitigation Approaches
Abstract not provided
Climate-driven shifts in freshwater biodiversity will impact mitigation costs for hydropower
Not Available
Assessment of energy and thermal resilience performance to inform climate mitigation of multifamily buildings in disadvantaged communities
Not Available
Greenhouse Gas Emission Mitigation Potential of Chemicals Produced from Biomass
Not Available
Regime-Dependence of Nocturnal Nitrate Formation via N 2 O 5 Hydrolysis and Its Implication for Mitigating Nitrate Pollution
The heterogeneous hydrolysis of dinitrogen pentoxide (N 2 O 5 ) is an important pathway in nitrate formation; however, its formation rate and relative contribution to total particulate nitrate (pNO 3 - ) are highly variable. Here we report that nocturnal pNO 3 - formation via N 2 O 5 hydrolysis is dependent on the regime defined by the ratio of NO 2 to O 3 . Nocturnal pNO 3 - formation via N 2 O 5 hydrolysis is suppressed in an O 3 -limited regime but enhanced in a NO 2 -limited regime. The results have crucial implications for effective control of nitrate pollution in the future. An exclusive decrease in NO 2 will decrease nocturnal pNO 3 - formation in a NO 2 -limited regime but may be less effective or even increase nocturnal pNO 3 - formation in an O 3 -limited regime.
A cleaner snow future mitigates Northern Hemisphere snowpack loss from warming
Abstract Light-absorbing particles (LAP) deposited on seasonal snowpack can result in snow darkening, earlier snowmelt, and regional climate change. However, their future evolution and contributions to snowpack change relative to global warming remain unclear. Here, using Earth System Model simulations, we project significantly reduced black carbon deposition by 2081-2100, which reduces the December-May average LAP-induced radiative forcing in snow over the Northern Hemisphere from 1.3 Wm −2 during 1995-2014 to 0.65 (SSP126) and 0.49 (SSP585) Wm −2 . We quantify separately the contributions of climate change and LAP evolution on future snowpack and demonstrate that projected LAP changes in snow over the Tibetan Plateau will alleviate future snowpack loss due to climate change by 52.1 ± 8.0% and 8.0 ± 1.1% at the end of the century for the two scenarios, mainly due to reduced black carbon contamination. Our findings highlight a cleaner snow future and its benefits for future water supply from snowmelt especially under the sustainable development pathway of SSP126.
Optimization of floodwater redistribution from Lake Nasser could recharge Egypt’s aquifers and mitigate its excessive floods
Extreme precipitation periods, possibly related to climate change, over the Nile River source areas caused flooding in Sudan and excess runoff reaching Lake Nasser in Egypt in 1998–2002 and 2019–2022. Excess water from the 1st event (25.5 × 10 9 m 3 ) was channeled to depressions within the plateau west of the Nile Valley, forming the Tushka Lakes, where it was left to evaporate, a fate that awaits the 53.5 × 10 9 m 3 from the 2nd event while the underlying fossil Nubian Sandstone Aquifer System is being depleted (–0.98 × 10 9 m 3 /yr). We simulated release scenarios of excess Lake Nasser waters (53.5 × 10 9 m 3 ) to proximal lowlands; preference was given to the scenario that recharged the aquifer through infiltration (74.3%) and minimized losses to evaporation (20.1%) and surface runoff (5.6%). Findings serve as an example of adaptations that replace catastrophic consequences of climate change with beneficial and sustainable development opportunities.
Divertor heat flux mitigation in the National Spherical Torus Experiment
Steady-state handling of divertor heat flux is a critical issue for both ITER and spherical torus-based devices with compact high power density divertors. Significant reduction of heat flux to the divertor plate has been achieved simultaneously with favorable core and pedestal confinement and stability properties in a highly shaped lower single null configuration in the National Spherical Torus Experiment (NSTX) [M. Ono , Nucl. Fusion 40, 557 2000] using high magnetic flux expansion at the divertor strike point and the radiative divertor technique. A partial detachment of the outer strike point was achieved with divertor deuterium injection leading to peak flux reduction from 4-6 MW m(-2) to 0.5-2 MW m(-2) in small-ELM 0.8-1.0 MA, 4-6 MW neutral beam injection-heated H-mode discharges. A self-consistent picture of the outer strike point partial detachment was evident from divertor heat flux profiles and recombination, particle flux and neutral pressure measurements. Analytic scrape-off layer parallel transport models were used for interpretation of NSTX detachment experiments. The modeling showed that the observed peak heat flux reduction and detachment are possible with high radiated power and momentum loss fractions, achievable with divertor gas injection, and nearly impossible to achieve with main electron density, divertor neutral density or recombination increases alone.
NIMROD EXTENDED MHD SIMULATIONS FOR DISRUPTION MITIGATION STUDIES
No abstract prepared.
Vibration mitigation in J-TEXT far-infrared diagnostic systems
Optical structure stability is an important issue for far-infrared (FIR) phase measurements. To ensure good signal quality, influence of vibration should be minimized. Mechanical amelioration and optical optimization can be taken in turn to decrease vibration's influence and ensure acceptable measurement. J-TEXT (Joint Texal Experiment Tokamak, formerly TEXT-U) has two FIR diagnostic systems: a HCN interferometer system for electron density measurement and a three-wave polarimeter-interferometer system (POLARIS) for electron density and Faraday effect measurements. All use phase detection techniques. HCN interferometer system has almost eliminated the influence of vibration after mechanical amelioration and optical optimization. POLARIS also obtained first experimental results after mechanical stability improvements and is expected to further reduce vibration's influence on Faraday angle to 0.1 Degree-Sign after optical optimization.