Search NASA⌕ Search

SEARCH · Search NASA

Results for “Maintainability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Bacterial communities protect the alga Microchloropsis salina from grazing by the rotifer Brachionus plicatilis

Open algal ponds are likely to succumb to unpredictable, devastating crashes by one or several deleterious species. Developing methodology to mitigate or prevent pond crashes will increase algal biomass production, drive down costs for algae farmers, and reduce the risk involved with algae cultivation, making it more favorable for investment by entrepreneurs and biotechnology companies. In this work, we postulate that specific algal-bacterial co-cultures grown with the green alga Microchloropsis salina prevented grazing by the marine rotifer, Brachionus plicatilis. We obtained seven algal-bacterial co-cultures from crashed rotifer cultures, maintained them in co-culture with Microchloropsis salina , and used a microalgal survival assay to determine that algae present in each co-culture were protected from rotifer grazing and culture crash. After months of routinely diluting and maintaining these seven algal-bacterial co-cultures, we repeated the assay and found the opposite result: none of the seven bacterial communities protected the microalgae from rotifer grazing. We performed 16S rRNA gene amplicon sequencing on the protective and nonprotective co-culture samples and identified substantial differences in the makeup of the bacterial communities. Protective bacterial communities consisted primarily of Alphaproteobacteria (Rhodobacteraceae) and Gammaproteobacteria ( Marinobacter , Pseudomonas, Methylophaga ) while nonprotective bacterial communities were less diverse and missing many putatively crucial members. We compared the seven protective communities with the seven nonprotective communities and we correlated specific bacterial amplicon sequence variants with algal protection. With these data, our future research will aim to define and develop an engineered-microbiome that can stabilize industrial Microchloropsis salina cultures by protecting against grazer-induced pond crashes.

59 BASIC BIOLOGICAL SCIENCES↗

Cost minimization of deoxygenation for control of Vampirovibrio chlorellavorus in Chlorella sorokiniana cultures

Deoxygenation is a strategy for preventing Vampirovibrio chlorellavorus infection of Chlorella sorokiniana cultures. Deoxygenation cost was minimized by sparging with nitrogen gas for only one hour at the onset of night and relying on naturally-occurring dark-respiration to maintain low oxygen concentrations throughout the night. This technique substantially reduced V. chlorellavorus infection in laboratory co-cultures. The cost of the approach was evaluated in outdoor experiments with one pure water and one pathogen-free C. sorokiniana culture, grown in a 150-L sealed, vented, translucent-polyethylene reactor. Unlike the small laboratory reactors, which were also sealed and vented, the much larger outdoor reactor maintained the dissolved oxygen concentration in the C. sorokiniana culture at near zero concentration throughout the night cycle. This demonstrates that large covered tanks in commercial applications would keep oxygen concentration near zero for the entire night. The total nitrogen sparged, per night, per liter of algal culture, was determined for the 150-L reactor, and used to estimate the cost per m2 for large scale raceways. Onsite nitrogen generators are the most cost-effective method to supply a high flow of nitrogen gas to commercial scale raceways. The cost of deoxygenation treatment ranged from $16/ton AFDW algae for a shallow (2 cm) gravity flow system with 75% harvest prior to deoxygenation to over $1,300/ton for a 20 cm depth raceway with plastic tanks.

59 BASIC BIOLOGICAL SCIENCES↗

Impact of changes in protective behaviors and out-of-household activities by age on COVID-19 transmission and hospitalization in Chicago, Illinois

Even with an efficacious vaccine, protective behaviors (social distancing, masking) are essential for preventing COVID-19 transmission and could become even more important if current or future variants evade immunity from vaccines or prior infection. Here we created an agent-based model representing the Chicago population and conducted experiments to determine the effects of varying adult out-of-household activities (OOHA), school reopening, and protective behaviors across age groups on COVID-19 transmission and hospitalizations. From September-November 2020, decreasing adult protective behaviors and increasing adult OOHA both substantially impacted COVID-19 outcomes; school reopening had relatively little impact when adult protective behaviors and OOHA were maintained. As of November 1, 2020, a 50% reduction in young adult (age 18-40) protective behaviors resulted in increased latent infection prevalence per 100,000 from 15.93 (IQR 6.18, 36.23) to 40.06 (IQR 14.65, 85.21)and 19.87 (IQR 6.83, 46.83) to 47.74 (IQR 18.89, 118.77) with 15% and 45% school reopening. Increasing adult (age ≥18) OOHA from 65% to 80% of pre-pandemic levels resulted in increased latent infection prevalence per 100,000 from 35.18 (IQR 13.59, 75.00) to 69.84 (IQR 33.27, 145.89) and 38.17 (IQR 15.84, 91.16) to 80.02 (IQR 30.91, 186.63) with 15% and 45% school reopening. Similar patterns were observed for hospitalizations. In areas without widespread vaccination coverage, interventions to maintain adherence to protective behaviors, particularly among younger adults and in out-of-household settings, remain a priority for preventing COVID-19 transmission.

60 APPLIED LIFE SCIENCES↗

Reactor physics analysis of a new Accident Tolerant Fuel called Fuel-in-Fibers

Fuel-in-Fibers (F-in-F) is an Accident Tolerant Fuel (ATF) concept aimed at significantly increasing the fission product retention capability of nuclear fuel at high temperatures, similar to another ATF concept, Fully Ceramic Microencapsulated Fuel (FCM). FCM, however, when implemented in a conventional Pressurized Water Reactor (PWR) fuel geometry, is not able to maintain an 18-month fuel cycle length and remain below the proliferation enrichment limit of 20 w/o 235 U using the standard cycle reload strategy. The F-in-F enrichment is decreased by putting the fuel in a cylindrical fiber instead of a spherical particle in order to increase the volume fraction of fuel in the pellet. The fibers are created with a direct manufacturing process that allows for the minimization of the volume occupied by the SiC matrix and the maximization of uranium loading via direct deposition of high density fuels like uranium nitride (UN). The full core reactor physics simulation showed that when the F-in-F design used UN as a fuel, it only required enrichments of 6% to maintain an 18-month fuel cycle length. Based on a full core analysis when compared to the current reference fuel for a standard 4-loop Westinghouse PWR, F-in-F has a similar steady state thermal hydraulic and neutronic performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Californium-252 production at the High Flux Isotope Reactor - II: Comparison between the highly enriched uranium and a proposed low-enriched uranium core

This is the second paper on a 252 Cf production study performed in support of efforts to convert the High Flux Isotope Reactor (HFIR) from highly enriched uranium (HEU) to low-enriched uranium (LEU) fuel. The first paper primarily focuses on validating computational tools and nuclear data. This companion paper evaluates another critical aspect: the 252 Cf production capability with a proposed LEU core. HFIR must maintain its world-class performance and missions following conversion and because 252 Cf is a vital, multipurpose neutron-emitting radioisotope, the ability to efficiently produce 252 Cf must be preserved. In this study, the HFIRCON transport and depletion tool, several nuclear data libraries, and Campaign 78 data were used to compute 252 Cf production, sensitivity, and safety metrics. Further, results indicate the 252 Cf production and production rates are slightly higher with a 95MW th LEU core compared with those obtained with the 85MW th HEU core. Additionally, the target peak fission rate densities, discharge cumulative fission densities, and heat deposition rates with the LEU core are within a few percent of those calculated with the HEU core. The findings suggest HFIR’s 252 Cf production capability can be effectively maintained with an LEU core without adversely affecting the safety metrics.

07 ISOTOPE AND RADIATION SOURCES↗

Innovative control mechanism for research and test reactors using mandrel-shaped control rods

Research and test reactors have historically played a pivotal role in supporting the initial development of nuclear reactors. They continue to provide essential data for enhancing fuel designs and material knowledge. However, with many such reactors aging and the growing demand for data to bolster advanced reactor development, it is more necessary to research potential design attributes of the next generation of research and test reactors. For test reactors dedicated to fuel and material testing, the design of control mechanisms significantly influences the stabilization of neutron flux levels in irradiation positions while sustaining criticality. This study presents an innovative control mechanism for potential research and test reactor designs. It employs small absorber rods that move in opposite axial directions to maintain axial symmetry of power and neutron flux during burnup cycles. These rods maximize reactivity worth while also offering flexibility to flatten the radial power distribution. An axial translation of the control mechanisms’ absorbers, as compared to the rotational movement of absorbers in control cylinders, also provides a benefit to available excess reactivity and cycle length. Additionally, this work utilizes a simplified core model of the Advanced Test Reactor to assess the performance of this control mechanism. Compared to the current control system based on rotating control cylinders, the new control mechanism has the potential to enhance, or at least maintain, neutronic performance parameters in this reactor design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Efficient Computation of Doppler-Broadened Elastic Scattering Kernel Moments Using Ladder-Operator Formulation

Anefficient routine for computing Legendre moments of the Doppler-broadened elastic scattering kernel, including resonance scattering effects, has been implemented in the ISOXML module of Griffin. Isotropic scattering in the center-of-mass system and the ideal gas model for target motion are assumed. A ladder-operator formulation is introduced to compute all Legendre moments from order 0 to N simultaneously, enabling near-linear scaling of computational cost with respect to the maximum Legendre order. A physics-based strategy for constructing outgoing energy grids has also been developed, in which a tailored base grid is combined with adaptive refinement to maintain accuracy while limiting the number of outgoing energy points. For energies between resonances, a constant cross-section model is employed to further reduce computational cost. In addition, a quantitative criterion is derived to determine isotope-wise cut-off incident energies based on a prescribed up-scattering probability coverage. For 238U, up to incident energies of approximately 75, 230, and 661 eV at 294, 900, and 2500 K (corresponding to a 2% up-scattering probability threshold), computation of P0 kernels requires 1–8 s and computation of P0–P5 kernels requires 0.4–4 min using a single thread, while maintaining 1–3% relative error in up-scattering probability. These results demonstrate that the proposed formulation enables accurate and computationally practical Doppler-broadened kernel generation for online multigroup cross-section production in Griffin.

Doppler-broadening↗

Co-existence of atomically dispersed Ru and Ce 3+ sites is responsible for excellent low temperature N 2 O reduction activity of Ru/CeO 2

Nitrous oxide N 2 O reduction is a big challenge due to high global warming potential of N 2 O. (~300 times higher compared with CO 2 ). The best known catalysts, such as Rh/ceria, require relatively high temperatures for N 2 O decomposition. Herein, we report that Ru/ceria catalysts with low Ru loading of ~0.25 wt% efficiently catalyze low temperature N 2 O reduction by CO starting at 100 °C (full N 2 O conversion below 200 °C) under industrially relevant flow rates and gas concentrations. Further, this remarkable performance stems from maintaining isolated Ru cations even on reduced ceria surface and, simultaneously, the propensity of Ru to affect ceria surface to form labile surface oxygen thereby creating large number of oxygen vacancies (Ce +3 cations) in the presence of CO. In contrast, for Rh/CeO 2 catalysts with equivalent metal loading, the activity is much lower because atomically dispersed Rh sinters into metallic clusters at the onset reaction temperature (~200 °C): these clusters are much less effective than isolated single Ru ions, with lower Ce +3 concentration maintained on reduced Rh/CeO 2 catalyst. Our study highlights the benefits of gaining molecular-level insight into the dynamic nature of catalytically active sites under reaction conditions for preparing catalysts containing low loading of precious metals with unsurpassed low temperature activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating penalized logistic regression models to predict Heat-Related Electric grid stress days

Understanding the conditions associated with stress on the electricity grid is important in the development of contingency plans for maintaining reliability during periods when the grid is stressed. In this paper, heat-related grid stress and the relationship with weather conditions is examined using data from the eastern United States. Penalized logistic regression models were developed and applied to predict stress on the electric grid using weather data. The inclusion of other weather variables, such as precipitation, in addition to temperature improved model performance. Several candidate models and datasets were examined. A penalized logistic regression model fit at the operation-zone level was found to provide predictive value and interpretability. Additionally, the importance of different weather variables observed at different time scales were examined. Maximum temperature and precipitation were identified as important across all zones while the importance of other weather variables was zone specific. The methods presented in this work are extensible to other regions and can be used to aid in planning and development of the electrical grid.

Bramer, L. M.↗

Microalgae to biofuels through hydrothermal liquefaction: Open-source techno-economic analysis and life cycle assessment

Hydrothermal liquefaction is a promising conversion technology in algae biofuel research due to its ability to agnostically convert proteins, carbohydrates, and lipids to biocrude. The high-temperature conditions that define this conversion process require the material to maintain a subcritical liquid state, which complicates the assessment of accurate thermochemical properties due to the required pressure. To clarify this issue, this work compares the estimated performance of algal hydrothermal liquefaction between different thermodynamic models. A process model was developed in Aspen Plus from a robust assessment of current literature. Techno-economic assessment and life-cycle assessment metrics are derived from this model and used as key performance indicators. The baseline fuel price contribution of hydrothermal liquefaction is $0.45 per liter gasoline equivalent. Independently decreasing the temperature from 350 °C to 260 °C while maintaining yield reduces the conversion cost by 19%, illustrating the importance of understanding the high-temperature thermodynamics of the system. Different thermodynamic property models can vary fuel conversion cost results by $0.07 per liter gasoline equivalent. The baseline global warming potential is +23 g CO 2 eq MJ -1 and the net energy ratio is 0.30. Environmental metrics beyond global warming potential and net energy ratio are also discussed for the first time. Uncertainties in conversion performance are bounded through a scenario analysis that manipulates parameters such as product yield and nutrient recycle to produce a range of economic and environmental metrics. The report is supplemented with an open source model to support future hydrothermal liquefaction assessments and accelerate the development of commercial-scale systems.

09 BIOMASS FUELS↗

Model predictive control for integrated control of air-conditioning and mechanical ventilation, lighting and shading systems

Modern buildings are increasingly automated and often equipped with multiple building services (e.g., air-conditioning and mechanical ventilation (ACMV), dynamic shading, dimmable lighting). These systems are conventionally controlled individually without considering their interactions, affecting the building’s overall energy inefficiency and occupant comfort. A model predictive control (MPC) system that features a multi-objective MPC scheme to enable coordinated control of multiple building services for overall optimized energy efficiency, indoor thermal and visual comfort, as well as a hybrid model for predicting indoor visual comfort and lighting power is proposed. The MPC system was implemented in a test facility having two identical, side-by-side experimental cells to facilitate comparison with a building management system (BMS) employing conventional reactive feedback control. The MPC system coordinated the control of the ACMV, dynamic façade and automated dimmable lighting systems in one cell while the BMS controlled the building services in the other cell in a conventional manner. The MPC side achieved 15.1–20.7% electricity consumption reduction, as compared to the BMS side. Simultaneously, the MPC system improved indoor thermal comfort by maintaining the room within the comfortable range (-0.5 < predicted mean vote < 0.5) for 98.3% of the time, up from 91.8% of the time on the BMS side. Visual comfort, measured by indoor daylight glare probability (DGP) and horizontal illuminance level at work plane height, was maintained for the entire test period on the MPC side, improving from having visual comfort for 94.5% and 85.7% of the time, respectively, on the BMS side.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Community-scale interaction of energy efficiency and demand flexibility in residential buildings

Demand-side management (DSM) strategies, including energy efficiency (EE) and demand flexibility (DF), contribute to cost-effective operation of the electricity grid. From a system-level perspective, such programs reduce costs, enhance reliability, and reduce network issues. Similarly, DSM programs help participating customers reduce utility bills while maintaining occupant comfort. Understanding the relationship between EE and DF is key to realizing the full potential of DSM programs. In this study, we modeled an all-electric residential community based on a 498-home community that is planned for construction in Fort Collins, Colorado in the United States. We used this community model to study the relationship between different EE measures, including building envelope upgrades and smart appliances, and DF enabled by a home energy management system (HEMS) responding to a time-varying tariff. Various EE levels in the homes – code-minimum, zero energy ready, and even higher levels of envelope efficiency – were simulated. DF is enabled by the HEMS, which coordinates behind-the-meter resources, including flexible building loads, PV, and home battery systems, to minimize utility bills while maintaining occupant comfort. When comparing to the code-minimum homes, EE upgrades alone reduce HVAC energy use during peak hours by up to 50% and the HVAC utility bill by up to $312/year. With the addition of HEMS, the average daily peak demand can be reduced by up to 0.58 MW or 1.2 kW/home in the higher envelope efficiency homes. The combination of EE upgrades, HEMS, and home battery systems is expected to save homeowners up to $590/year while increasing community load flexibility. However, HEMS and home battery systems are less effective in increasing the DF in the more efficient homes due to the lower load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of controls for integrated energy storage system in energy arbitrage configuration with concrete thermal energy storage

Novel highly detailed NuScale reactor and turbo-generator models have been built in Modelica to analyze potential controls for an integrated energy system (IES) configuration combining a nuclear reactor and concrete thermal energy storage (CTES) operating in energy arbitrage. A shakedown test demonstrates the viability of the control schemes to operate across expected operating conditions while maintaining safety limits and buffers. A five-day data set from Idaho is used to show a load-following application of this system that increases the average reactor power level by 20% over the data set and matching demand at nearly all points. Here, by integrating these models, feedback mechanisms across the primary and secondary sides of the nuclear reactor are integrated, and realistic control evaluation is done. All models are consistent with the Hybrid repository, a suite of Modelica models, maintained at Idaho National Laboratory.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Distributed Wind-Hybrid Microgrids with Autonomous Controls and Forecasting

Distributed wind-hybrid microgrids have the potential to provide key resilience and economic benefits to both the customers they serve and the utility grids they are connected to. Such microgrids will likely be a key part of the grid of the future, whether connected to large utility grids or linked together in multi-microgrid systems. Through the hybridization of distributed wind and solar photovoltaics, autonomous device-level and system-level controls, battery energy storage systems with smart inverters, and forecasting, these microgrids could maintain local stability and provide grid services - all with renewable power. In the literature, these elements have been considered individually. However, they have not been combined and demonstrated at a high fidelity, which is essential to prove the concept's operation before moving to hardware-in-the-loop and physical demonstrations. In this work, we develop a high-fidelity MATLAB-Simulink model of a real distributed wind-hybrid microgrid that includes all these elements. We demonstrate the microgrid maintaining stability and production in a variety of islanded, grid-connected, and transition scenarios. This includes riding through faults and grid transitions, handling resource variability, and providing grid services. The results demonstrate, at a high fidelity, how distributed wind-hybrid microgrids can operate in an economic and resilient fashion. Finally, we provide recommendations for future research to move advanced distributed wind-hybrid microgrids toward deployment.

ancillary services↗

Control methods for mitigating flow oscillations in a supercritical CO 2 recompression closed Brayton cycle

A dynamic model of a 10 MWe supercritical CO 2 (sCO 2 ) recompression closed Brayton power generation cycle is used to investigate control methods for mitigating oscillations in flow conditions and power demand load, especially as the load ramp rate is increased and the load setpoint is more closely tracked. The focus is on control of the main compressor inlet temperature (MCIT) since oscillations are prompted by the strong nonlinearities in sCO 2 fluid properties near the critical point and by changes in system inventory for efficient load management. In this study, the oscillatory behavior during load ramping is first shown and then two potential control solutions for substantially reducing oscillations are given: 1) the use of the main compressor inlet guide vanes (IGV) and 2) bypassing a portion of the sCO 2 around the cooler to maintain the MCIT. These control methods reduce the effect of cycle feedback from interactions between the MCIT and load. When implementing either control method, a load setpoint ramp of 7.5%/min was maintainable while achieving closer load setpoint tracking with limited oscillations. Finally, the impact of sensor noise on the control was examined since derivative action was used in the IGV and cooler sCO 2 bypass control. Finally, while some effect was evident, signal noise was not problematic to the control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Household energy resilience in extreme weather events: An investigation of energy service importance, HVAC usage behaviors, and willingness to pay

Household energy resilience, particularly maintaining essential energy services within an acceptable and affordable level, is critical during extreme weather events (e.g., winter storms, heat waves) with power shortages or outages. However, the research on the importance and acceptable compromise levels of energy services, HVAC usage behavior changes, and willingness to pay (WTP) for energy services during disasters is limited. Therefore, this study investigates the importance and compromise of household energy services, HVAC usage behaviors, and WTP, as three key dimensions of household energy resilience, in both normal days and disaster scenarios through surveys (n=485). First, 12 common residential end-uses are grouped into high, mid, and low-priority services using hierarchical clustering, in which high-priority services (perceived as important and un-compromisable) include food cooking and storage (refrigerator and freezer) and thermal comfort (space heating and cooling), mid-priority services involve water heating and lighting, while low-priority services are mostly related to entertainment and housework (e.g., TV, laundry). Also, HVAC use patterns demonstrate that occupants become more energy conservative during disasters, e.g., reducing durations of running HVAC and adjusting temperature setpoints to save energy. In terms of energy cost, approximately 60% of respondents are willing to pay more to maintain energy services during disasters, although only 13% are prepared to pay over double the normal energy prices. The regression models further reveal that household energy resilience varies across different sociodemographic groups (e.g., age, income, family size) and is impacted by disaster experience and beliefs in clean energy and climate. In conclusion, these research findings provide important perspectives to understand household energy resilience and inform measures for disaster adaptation of households in extreme weather events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operator learning for energy-efficient building ventilation control with computational fluid dynamics simulation of a real-world classroom

Energy-efficient ventilation control plays an important role in reducing building energy consumption while ensuring occupant health and comfort. While Computational Fluid Dynamics (CFD) simulations provide detailed and physically accurate representations of indoor airflow, their high computational cost limits their use in real-time building control. In this work, we present a neural operator learning framework that combines the physical accuracy of CFD with the computational efficiency of machine learning to enable building ventilation control with the high-fidelity fluid dynamics models. Our method jointly optimizes the airflow supply rates and vent angles to reduce energy use and adhere to air quality constraints. We train an ensemble of neural operator transformer models to learn the mapping from building control actions to airflow fields using high-resolution CFD data. This learned neural operator is then embedded in an optimization-based control framework for building ventilation control. Experimental results show that our approach achieves significant energy savings compared to maximum airflow rate control, rule-based control, as well as data-driven control methods using spatially averaged CO 2 prediction and deep learning–based reduced-order models, while consistently maintaining safe indoor air quality. These results highlight the practicality and scalability of our method in maintaining energy efficiency and indoor air quality in real-world buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Designing reinforcement learning algorithms for building HVAC control: From experimental observation to simulation comparisons

Advanced supervisory-level control with reinforcement learning (RL) is regarded as a promising solution for HVAC systems to minimize energy consumption while maintaining thermal comfort and indoor air quality. However, most RL applications were conducted in the simulation environment rather than real-world HVAC systems. This paper developed a value-based RL controller termed Deep Q-Network (DQN) for a typical central HVAC system and evaluated its performance in a building test facility. By comparing DQN with a rule-based controller, the study not only demonstrated the cases where DQN could properly maintain indoor comfort but also discussed possible reasons why DQN failed in some other situations. Recognizing the limitations of value-based RL algorithms from the experimental tests, a simulation study was conducted to compare DQN with an alternative RL approach, an actor–critic algorithm termed Deep Deterministic Policy Gradient (DDPG). In scenarios with a relatively large action space, DDPG outperformed DQN by requiring fewer computational resources and achieving better thermal comfort, lower energy consumption, and more stable control actions. The findings suggest that the ability of DDPG to handle continuous control variables more effectively allows for faster convergence in training and more precise control in practice, which enhances the overall efficiency and reliability of the HVAC system.

Guo, Fangzhou↗