Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material Point Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Two-step synthesis of few layer graphene using plasma etching and atmospheric pressure rapid thermal annealing

A two-step process using halogen based plasma etching combined with atmospheric pressure rapid thermal annealing has been used to synthesize few layer graphene films on 6H-SiC (0001) surfaces. In this process, the 6H-SiC substrates were etched under different plasma conditions to produce a carbon rich surface layer. This was followed by rapid thermal annealing in a flow of atmospheric pressure Ar to produce the graphene films. The effects of different etching conditions, heating rates, and average and maximum annealing temperatures were investigated. Changes in surface and near-surface composition after each step were characterized by x-ray photoelectron spectroscopy and overall film quality was assessed using Raman spectroscopy. Film defects associated with this synthesis method included a buffer layer between the SiC substrate and graphene as well as oxygen-based defects on the graphene surface. Electrical characterization of these films was performed using both two and four point methods. In the two point measurements, these films exhibited back-to-back Schottky behavior from which the Schottky barrier height, carrier density and mobility were determined. The four point measurements were used to determine the contact and film resistivity as well as the transfer length.

36 MATERIALS SCIENCE↗

Synthesis, structural characterization and high pressure phase transitions of monolithium hydronium sulfate

A three dimensional lithium hydronium sulfate LiSO{sub 4}{center_dot}H{sub 3}O [1], [space group Pna2{sub 1}a=8.7785(12) A, b=9.1297(12) A, c=5.2799(7) A, V=423.16(10) A{sup 3}] was synthesized via solvothermal methods using 1,5-naphthalenedisulfonic acid (1,5-NSA) as the source of sulfate ions. The structure of [1], determined by single crystal X-ray diffraction techniques, consists of corner sharing LiO{sub 4} and SO{sub 4} tetrahedra, forming an anionic 3-D open framework that is charge balanced by hydronium ions positioned within channels running along [001] and forming strong H-bonding with the framework oxygen atoms. Compound [1] undergoes two reversible phase transitions, involving reorientation of SO{sub 4}{sup 2-} ions at pressures of approximately 2.5 and 5 GPa at room temperature, as evident from characteristic discontinuous frequency drops in the {nu}{sub 1} mode of the Raman spectra. Additionally, compound [1] forms dense {beta}-lithium sulfate at 300 Degree-Sign C, as evident from temperature dependent powder XRD and combined reversible TGA-DSC experiments. - Graphical abstract: Left: View of corner-shared LiO{sub 4} and SO{sub 4} tetrahedra along [001] direction with hydronium ions situated in the channels. Right: (a) Photograph of the loaded DAC (b) Ambient pressure Raman spectrum of compound [1] (c) Evolution of the {nu}{sub 1} mode with the increasing and decreasing pressure indicating transitions to high-pressure phases at {approx}2.5 (red curves) and {approx}5 GPa (blue curves) and at {approx}3.5 GPa upon decompression. Highlights: Black-Right-Pointing-Pointer A 3-D lithium hydronium sulfate is synthesized by solvothermal methods. Black-Right-Pointing-Pointer Two high pressure phase transition occurs due to rotation of sulfate groups. Black-Right-Pointing-Pointer The framework undergoes a high temperature structural transformation, to form {beta}-Li{sub 2}SO{sub 4} phase.

36 MATERIALS SCIENCE↗

Synthesis of nanocrystalline CeO{sub 2} particles by different emulsion methods

Cerium oxide nanoparticles were synthesized using three different methods of emulsion: (1) reversed micelle (RM); (2) emulsion liquid membrane (ELM); and (3) colloidal emulsion aphrons (CEAs). Ammonium cerium nitrate and polyoxyethylene-4-lauryl ether (PE4LE) were used as cerium and surfactant sources in this study. The powder was calcined at 500 Degree-Sign C to obtain CeO{sub 2}. The effect of the preparation procedure on the particle size, surface area, and the morphology of the prepared powders were investigated. The obtained powders are highly crystalline, and nearly spherical in shape. The average particle size and the specific surface area of the powders from the three methods were in the range of 4-10 nm and 5.32-145.73 m{sup 2}/g, respectively. The CeO{sub 2} powders synthesized by the CEAs are the smallest average particle size, and the highest surface area. Finally, the CeO{sub 2} prepared by the CEAs using different cerium sources and surfactant types were studied. It was found that the surface tensions of cerium solution and the type of surfactant affect the particle size of CeO{sub 2}. - Graphical Abstract: The emulsion droplet size distribution and the TEM images of CeO{sub 2} prepared by different methods: reversed micelle (RM), emulsion liquid membrane (ELM) and colloidal emulsion aphrons (CEAs). Highlights: Black-Right-Pointing-Pointer Nano-sized CeO{sub 2} was successfully prepared by three different emulsion methods. Black-Right-Pointing-Pointer The colloidal emulsion aphrons method producing CeO{sub 2} with the highest surface area. Black-Right-Pointing-Pointer The surface tensions of a cerium solution have slightly effect on the particle size. Black-Right-Pointing-Pointer The size control could be interpreted in terms of the adsorption of the surfactant.

36 MATERIALS SCIENCE↗

Rapid Multiscale Computational Screening for OLED Host Materials

The design of new host materials for phosphorescent OLEDs is challenging because several physical property requirements must be met simultaneously. A triplet energy (E T ) higher than that of the chosen emitting dopant, appropriate HOMO/LUMO energy levels, good charge carrier transport, and high stability are all required. Here, computational methods were used to screen structures to find the most promising candidates for OLED hosts. The screening was carried out in three Tiers. The Tier 1 selection, based on Density Functional Theory calculations identified a set of eight molecular structures with E T > 2.9 eV, suitable for hosting blue phosphorescent dopants such as iridium(III)bis((4,6-di-fluorophenyl)-pyridinato-N,C2’)picolinate (FIrpic). Phenanthro[9,10 d]imidazole was chosen as the starting point for the Tier 2 selection. Thirty seven unique molecular structures were enumerated by isoelectronic nitrogen transmutation of up to two CH fragments of the phenanthrene. Three molecules, i.e. imidazo[4,5 f] phenanthrolines with nitrogens at the 1,10 , 3,8 and 4,7 positions, were selected for Tier 3, which involved the use of molecular dynamics simulations and electron coupling calculations to predict differences in charge transport between the three materials. The three were explored experimentally through synthesis and device fabrication. The singlet, triplet, and frontier orbital energies computed using single molecule DFT calculations (tiers 1 and 2) were consistent with the experimental values in fluid solution, and the multi scale modeling scheme (tier 3) correctly predicted the poor device performance of one material. Here, we conclude that screening host materials using only single molecule quantum mechanical data was not sufficient to predict whether a given material would make a good OLED host with certainty, however they can be used to screen out materials that are destined to fail due to low singlet/triplet energies or a poor match of the frontier orbital energies to the dopant or transport materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Forward-Weighted CADIS Method for Variance Reduction of Monte Carlo Reactor Analyses

Current state-of-the-art tools and methods used to perform 'real' commercial reactor analyses use high-fidelity transport codes to produce few-group parameters at the assembly level for use in low-order methods applied at the core level. Monte Carlo (MC) methods, which allow detailed and accurate modeling of the full geometry and energy details and are considered the 'gold standard' for radiation transport solutions, are playing an ever-increasing role in correcting and/or verifying the several-decade-old methodology used in current practice. However, the prohibitive computational requirements associated with obtaining fully converged system-wide solutions restrict the role of MC to benchmarking deterministic results at a limited number of state-points for a limited number of relevant quantities. A goal of current research at Oak Ridge National Laboratory (ORNL) is to change this paradigm by enabling the direct use of MC for full-core reactor analyses. The most significant of the many technical challenges that must be overcome is the slow non-uniform convergence of system-wide MC estimates and the memory requirements associated with detailed solutions throughout a reactor (problems involving hundreds of millions of different material and tally regions due to fuel irradiation, temperature distributions, and the needs associated with multi-physics code coupling). To address these challenges, research has focused on development in the following two areas: (1) a hybrid deterministic/MC method for determining high-precision fluxes throughout the problem space in k-eigenvalue problems and (2) an efficient MC domain-decomposition algorithm that partitions the problem phase space onto multiple processors for massively parallel systems, with statistical uncertainty estimation. The focus of this paper is limited to the first area mentioned above. It describes the FW-CADIS method applied to variance reduction of MC reactor analyses and provides initial results for calculating group-wise fluxes throughout a generic 2-D pressurized water reactor (PWR) quarter core model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

First-principles studies on linear and nonlinear optical effects in Ln{sub 4}GaSbS{sub 9} (Ln=Ce-Nd, Sm, Gd-Tm, Lu)

Density functional theory (DFT) calculations have been performed on electronic structures of 11 middle-infrared (mid-IR) nonlinear optical quaternary sulfides: Ln{sub 4}GaSbS{sub 9} (Ln=Ce-Nd, Sm, Gd-Tm, Lu). Our results show that Ln{sub 4}GaSbS{sub 9} are indirect gap semiconductors with a slight band gap increase from Ce to Lu. Their linear optical properties, including refractive index, absorption coefficient and energy loss function, as well as the nonlinear optical coefficients including static d{sub 31}, d{sub 32}, d{sub 33} and dynamic d{sub 32}, are calculated. More importantly, the strong SHG response of Ln{sub 4}GaSbS{sub 9} can be attributed to the electronic transitions from S 3p states in valence bands (VB) to Sb-S and Ln-S antibonding states (CB). - Graphical Abstract: Density functional theory (DFT) calculations on Ln{sub 4}GaSbS{sub 9} reveal their linear optical properties, including refractive index, adsorption coefficient and energy loss function, the nonlinear optical coefficients including static d{sub 31}, d{sub 32}, d{sub 33} and dynamic d{sub 32}, as well as the origins of the strong SHG response. Highlights: Black-Right-Pointing-Pointer First-principles studies on a newly discovered NLO active family Ln{sub 4}GaSbS{sub 9}. Black-Right-Pointing-Pointer Reports static SHG coefficients (d{sub 31}, d{sub 32}, d{sub 33}) and dynamic d{sub 32}. Black-Right-Pointing-Pointer Reveals the origin of the strong SHG response.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of E{sub 1}(LO) phonon-plasmon coupled modes and critical points in In{sub 1-x}Ga{sub x}N thin films by optical reflectance measurements

Low energy optical modes of molecular beam epitaxy-grown In{sub 1-x}Ga{sub x}N thin films with 0<=x<=0.6 are investigated using infrared reflectance measurements. We found that the reflectance of the films for wave vectors in the range from 600 to 800 cm{sup -1} is determined by the high energy E{sub 1}(LO)-plasmon coupled modes. In the higher energy regime of the UV-visible reflectance spectrum of InN, critical points with energies 4.75, 5.36, and 6.12 eV belonging to A and B structures are observed. The energies of these critical points increase with increasing values of x, similar to the band gap energy of these films.

36 MATERIALS SCIENCE↗

Enhanced light scattering in Si nanostructures produced by pulsed laser irradiation

An innovative method for Si nanostructures (NS) fabrication is proposed, through nanosecond laser irradiation (λ = 532 nm) of thin Si film (120 nm) on quartz. Varying the laser energy fluences (425–1130 mJ/cm{sup 2}) distinct morphologies of Si NS appear, going from interconnected structures to isolated clusters. Film breaking occurs through a laser-induced dewetting process. Raman scattering is enhanced in all the obtained Si NS, with the largest enhancement in interconnected Si structures, pointing out an increased trapping of light due to multiple scattering. The reported method is fast, scalable and cheap, and can be applied for light management in photovoltaics.

36 MATERIALS SCIENCE↗

Postmastectomy Chest Wall Radiation to a Temporary Tissue Expander or Permanent Breast Implant-Is There a Difference in Complication Rates?

Purpose: The purpose of this study was to evaluate the likelihood of complications and cosmetic results among breast cancer patients who underwent modified radical mastectomy (MRM) and breast reconstruction followed by radiation therapy (RT) to either a temporary tissue expander (TTE) or permanent breast implant (PI). Methods and Materials: Records were reviewed of 74 patients with breast cancer who underwent MRM followed by breast reconstruction and RT. Reconstruction consisted of a TTE usually followed by exchange to a PI. RT was delivered to the TTE in 62 patients and to the PI in 12 patients. Dose to the reconstructed chest wall was 50 Gy. Median follow-up was 48 months. The primary end point was the incidence of complications involving the reconstruction. Results: There was no significant difference in the rate of major complications in the PI group (0%) vs. 4.8% in the TTE group. No patients lost the reconstruction in the PI group. Three patients lost the reconstruction in the TTE group. There were excellent/good cosmetic scores in 90% of the TTE group and 80% of the PI group (p = 0.22). On multivariate regression models, the type of reconstruction irradiated had no statistically significant impact on complication rates. Conclusions: Patients treated with breast reconstruction and RT can experience low rates of major complications. We demonstrate no significant difference in the overall rate of major or minor complications between the TTE and PI groups. Postmastectomy RT to either the TTE or the PI should be considered as acceptable treatment options in all eligible patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Time- and Dose-Dependency of Radiographic Normal Tissue Changes of the Lung After Stereotactic Radiotherapy

Purpose: Normal tissue changes (NTC) of the normal lung parenchyma are commonly seen after stereotactic single-dose radiotherapy (radiosurgery) of lung tumors. The aim of this study was to investigate the extent and dynamics of NTCs after radiosurgery. Methods and Materials: Fifty lung tumors in 49 patients were treated with radiosurgery. Follow-up CTs were anatomically matched to the treatment planning CTs, incorporating the treatment plan and enabling spatial correlation of initial radiation dose distribution and subsequent NTCs of the lung. Lung parenchyma was divided into nine areas of different radiation dose exposures (range, 6-35 Gy). Areas were investigated and compared at different time points according to the development of NTCs. Results: Twenty-six patients developed NTCs during follow-up. The evaluation of the dependency of the extent of NTCs on the amount of radiation dose lead to a linear model for the fixed effects: Fraction of reacting volume =Intercept{sub T} +0.0208 * Dose ('Dose' should be given in Gy). Dose had a slope of 0.0208 (fraction of normal tissue reaction/Gy) (SE 0.000804, p < 0.0001), implying a significant correlation between dose level and the extent of NTC. Conclusion: For radiosurgery of lung tumors, a significant correlation of radiation dose and the extent of NTCs could be demonstrated. Using the introduced formula, a preview on the extent of NTCs to develop in normal lung parenchyma according to the dose level can be performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Six Degrees-of-Freedom Prostate and Lung Tumor Motion Measurements Using Kilovoltage Intrafraction Monitoring

Purpose: Tumor positional uncertainty has been identified as a major issue that deteriorates the efficacy of radiation therapy. Tumor rotational movement, which is not well understood, can result in significant geometric and dosimetric inaccuracies. The objective of this study was to measure 6 degrees-of-freedom (6 DoF) prostate and lung tumor motion, focusing on the more novel rotation, using kilovoltage intrafraction monitoring (KIM). Methods and Materials: Continuous kilovoltage (kV) projections of tumors with gold fiducial markers were acquired during radiation therapy for 267 fractions from 10 prostate cancer patients and immediately before or after radiation therapy for 50 fractions from 3 lung cancer patients. The 6 DoF motion measurements were determined from the individual 3-dimensional (3D) marker positions, after using methods to reject spurious and smooth noisy data, using an iterative closest point algorithm. Results: There were large variations in the magnitude of the tumor rotation among different fractions and patients. Various rotational patterns were observed. The average prostate rotation angles around the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) axes were 1.0 ± 5.0°, 0.6 ± 3.3°, and 0.3 ± 2.0°, respectively. For 35% of the time, the prostate rotated more than 5° about the LR axis, indicating the need for intrafractional adaptation during radiation delivery. For lung patients, the average LR, SI, and AP rotation angles were 0.8 ± 4.2°, −0.8 ± 4.5°, and 1.7 ± 3.1°, respectively. For about 30% of the time, the lung tumors rotated more than 5° around the SI axis. Respiration-induced rotation was detected in 2 of the 3 lung patients. Conclusions: The prostate and lung tumors were found to undergo rotations of more than 5° for about a third of the time. The lung tumor data represent the first 6 DoF tumor motion measured by kV images. The 6 DoF KIM method can enable rotational and translational adaptive radiation therapy and potentially reduce treatment margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-E-15: Design of a Water Calorimeter for Dual Use in An Integrated MRI-Linac and Gamma-Knife

Purpose: To design a water calorimeter for dual use in an integrated MRI-linac and Gamma-Knife. In calorimetry, dose to water is measured based on the assumption that energy absorbed in a sensitive volume is completely converted to temperature rise {sub (}ΔΤ{sub )} according to the specific heat capacity of the medium c: D=c*ΔT*k, where k is heat transfer correction factor and compensates for heat gain or loss at point of measurement due to conductive effects. Methods: A commercial finite element method software package was used to model four different water calorimeter designs. The long term (48 h) thermal stability of each design was accurately modeled, and the optimization of the final design was based on evaluation of the standard deviation of k for ten consecutive irradiation runs (lower standard deviation translates to greater thermal stability). Several insulator materials of varying thicknesses were investigated, and a sensitivity study of thermal stability to variations in ambient temperature fluctuations was undertaken. Specifically, we evaluated the effect of possible variations in coolant temperature circulating around the calorimeter tank in several scenarios (constant, slowly increasing, or fluctuating). Results: Due to MRI-compatibility requirements, the calorimeter is to be built entirely out of plastic. Among all insulation materials tested, solid state aerogel-based insulation resulted in least heat loss and thermal stability. The final design is cylindrical on top (to be used upright in MRI-linac) and semi-spherical at bottom (for use in GammaKnife). The range of k was found to be 1.002 ± 0.013 (k = 1), comparable with a k of 1.002 ± 0.014 for typical water calorimeters used in high energy beams. A long term stability of 0.36 µK/hr was evaluated. Conclusion: Optimization of a water calorimeter design for dual use in MRI-linac and Gamma-Knife has been completed and the device is currently in production. Supported by NSERC RGPIN 435608.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Localizing Holes as Polarons and Predicting Band Gaps, Defect Levels, and Delithiation Energies of Solid-State Materials with a Local Exchange-Correlation Functional

Here, we assess the performance of seven exchange–correlation functionals (some with and some without a Hubbard U correction) for their ability (i) to predict band gaps of silicon, diamond, and Li-ion battery cathode materials, (ii) to localize hole polarons and predict delithiation energies in Li-ion battery cathode materials, and (iii) to predict transition levels of charge carriers of doped silicon and diamond. Both local and hybrid exchange–correlation functionals were tested. The local functionals tend to underestimate band gaps and delocalize polarons. The hybrid functionals very often give a good description of both properties, but they may not be practical for calculations involving large unit cells, large ensembles, or dynamics, and therefore a local functional with a Hubbard U correction is often used (giving the method called DFT+U), where the value of a parameter U is adjusted according to the system and the property being investigated. Keeping in mind the importance of computational cost and the undesirability of having to adjust an empirical parameter for each system or property of interest, we recently developed a local functional, namely HLE17, to try to accurately predict band gaps and excitation energies, and we validated it using mostly main-group solids and molecules. Here we test the performance of HLE17 for its ability to predict band gaps and localize polarons in other solid-state materials, and we compare its performance to that of popular local functionals (PBE, PBEsol, and TPSS), a range-separated hybrid functional with screened exchange (HSE06), and DFT+U. We find that HLE17 predicts more accurate band gaps than other local functionals and can localize holes as polarons, which other local functionals usually fail to do, and for a number of cases it is comparable in performance quality to Hubbard-corrected functionals without the need for system-specific parametrization and to hybrid functionals without the high cost. Because HLE17 does not predict accurate lattice constants, we use the single-point method of quantum chemistry, where the geometry is optimized with one functional and the band gap is calculated with HLE17, or we perform calculations with the lattice constants obtained by TPSS and both the fractional intracell coordinates and the electronic structure obtained by HLE17 (a new method denoted HLE17\\TPSS). In particular, we performed calculations by HLE17//TPSS, HLE17//HSE06, HLE17//DFT+U, and HLE17\\TPSS, and these methods usually agree well with each other and give values similar to experiment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design Report on the MiniFuel Instrumented Test Apparatus for Understanding Radiation Effects

Most nuclear fuels irradiations at Oak Ridge National Laboratory (ORNL) over the past decade have been conducted using MiniFuel—a static capsule design employing subscale fuel specimens to collect separate-effects irradiated fuel performance data. Irradiation conditions for MiniFuel experiments are predicted pre-test using reactor physics, and thermal models are verified post-irradiation via SiC dilatometry and various spectrometry methods. Relevant fuel performance parameters are also observed post-irradiation in a hot cell, thereby providing a single data point for each parameter representing the cumulative effects of the irradiation conditions. Substantially more data can be harvested from a single test and within a shorter duration by instrumenting irradiation vehicles and measuring desired quantities in situ. This report presents the design and analysis of the MiniFuel INstrumented Irradiation Test Apparatus for Understanding Radiation Effects (MINITAURE)—an instrumented test rig based on the separate-effects MiniFuel concept that aims to capture fission gas release (FGR) and thermal conductivity degradation of fuel specimens during irradiation in the High Flux Isotope Reactor (HFIR). MINITAURE will be integrated with the Materials Irradiation Facility (MIF) located in the HFIR building outside the reactor containment. The MIF will act as the instrumentation and control center for the experiment, enabling real-time feedback from in situ sensors and control of irradiation temperatures via a gas delivery system. Two unique capsule designs were developed to capture each phenomenon: the thermal conductivity capsule, which uses a thermopile method to estimate fuel specimen thermal conductivity, and the fission gas release capsule, which will have continuous flowing gas communication to high-purity germanium detectors that are housed in the MIF for monitoring FGR. This report details the reactor physics and heat transfer modeling activities that were used to inform the experiment design and predict capsule performance. It also describes out-of-pile activities conducted to stand up this new capability and verify the measurement techniques. Modeling efforts to date have demonstrated the feasibility of the in situ measurement techniques and supported the development of the MINITAURE assembly configuration. Out-of-pile testing of the thermal conductivity measurement shows promise in capturing relative changes in thermal conductivity. However, significant errors exist in the measured absolute value, posing a need for further refinement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Magnetic Resonance Imaging-Based Radiation-Absorbed Dose Estimation of {sup 166}Ho Microspheres in Liver Radioembolization

Purpose: To investigate the potential of magnetic resonance imaging (MRI) for accurate assessment of the three-dimensional {sup 166}Ho activity distribution to estimate radiation-absorbed dose distributions in {sup 166}Ho-loaded poly (L-lactic acid) microsphere ({sup 166}Ho-PLLA-MS) liver radioembolization. Methods and Materials: MRI, computed tomography (CT), and single photon emission CT (SPECT) experiments were conducted on an anthropomorphic gel phantom with tumor-simulating gel samples and on an excised human tumor-bearing liver, both containing known amounts of {sup 166}Ho-PLLA-MS. Three-dimensional radiation-absorbed dose distributions were estimated at the voxel level by convolving the {sup 166}Ho activity distribution, derived from quantitative MRI data, with a {sup 166}Ho dose point-kernel generated by MCNP (Monte Carlo N-Particle transport code) and from Medical Internal Radiation Dose Pamphlet 17. MRI-based radiation-absorbed dose distributions were qualitatively compared with CT and autoradiography images and quantitatively compared with SPECT-based dose distributions. Both MRI- and SPECT-based activity estimations were validated against dose calibrator measurements. Results: Evaluation on an anthropomorphic phantom showed that MRI enables accurate assessment of local {sup 166}Ho-PLLA-MS mass and activity distributions, as supported by a regression coefficient of 1.05 and a correlation coefficient of 0.99, relating local MRI-based mass and activity calculations to reference values obtained with a dose calibrator. Estimated MRI-based radiation-absorbed dose distributions of {sup 166}Ho-PLLA-MS in an ex vivo human liver visually showed high correspondence to SPECT-based radiation-absorbed dose distributions. Quantitative analysis revealed that the differences in local and total amounts of {sup 166}Ho-PLLA-MS estimated by MRI, SPECT, and the dose calibrator were within 10%. Excellent agreement was observed between MRI- and SPECT-based dose-volume histograms. Conclusions: Quantitative MRI was demonstrated to provide accurate three-dimensional {sup 166}Ho-PLLA-MS activity distributions, enabling localized intrahepatic radiation-absorbed dose estimation by convolution with a {sup 166}Ho dose point-kernel for liver radioembolization treatment optimization and evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of the Chlorination Products of Zirconium Alloys used for Nuclear Fuel Cladding

The United States produces over 2000 metric tons of used nuclear fuel material per year, of which 25% is irradiated fuel cladding, and it is expected to increase for the next 50 years. Previous simulation studies have shown that in the irradiated cladding, the major activation products found are {sup 125}Sb, {sup 60}Co, and {sup 99m}Nb, and the major fission product found is {sup 137}Cs. These radioisotopes make it impossible to treat the cladding as low level waste. A chlorination process has been proposed for zirconium reprocessing as it has been proven more efficient than previous mechanical processes, redox processes, and other chemical methods (e.g. iodination). In the chlorination process, zirconium alloy cladding reacts with Cl{sub 2} at 350- 380 deg. C to produce mainly ZrCl{sub 4}. The zirconium tetrachloride has a relatively low sublimation point (331 deg. C) that allows its separation from other products, and so it can be treated as low level waste for disposal or recycling. However, previous work has observed element impurities (iron, tin, chromium, cesium, antimony, and niobium) in the recovered ZrCl{sub 4}, meaning that additional steps are necessary in a chlorination process previous to the reduction of ZrCl, to metallic Zr. The emphasis of this research summary is on the progress that has been made to isolate and characterize the impurities produced after chlorination of three previously characterized non-irradiated zirconium alloys (Zircaloy-2, Zircaloy-4, and a commercial Zr-Nb alloy) widely used as cladding materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determining Physical Parameters of Shielded Uranium using Gamma Spectroscopy and the Differential Evolution Adaptive Metropolis (DREAM) Method

Inverse radiation transport is a well-established method for determining unknown parameters within a system that exhibits particle leakage. Two significant challenges of solving inverse transport problems are (1) to determine multiple unknowns without false convergence on local minima and (2) to be able to quantify uncertainty. It was recently demonstrated that the Differential Evolution Adaptive Metropolis (DREAM) method effectively meets both of these challenges. In Bledsoe's 2014 article, the DREAM method was only applied to numerical test cases in which measured data were simulated using MCNP. This paper provides results of research conducted at Oak Ridge National Laboratory (ORNL) in which DREAM was applied to two-dimensional inverse transport problems using real-world measurements. The DREAM method uses a Markov chain Monte Carlo (MCMC) method to obtain a posterior distribution of unknown parameters. In this application, the posterior distribution is determined by using a uniform prior distribution and a likelihood function. The goal of the inverse problem is to find the regions in which the likelihood function is at or near its maximum. In the traditional MCMC approach, a single Markov chain is employed. In practice, MCMC approaches have a high acceptance rate to solutions that are near the current point of sampling, but they exhibit slow convergence to solutions far from the sampling point. The DREAM algorithm was designed to alleviate this issue by initiating multiple Markov chains and using the differential evolution algorithm to generate trial points for each chain. Solving for the mass of radioactive material within a voluminous source is a challenging problem for gamma-ray spectroscopy. Inverse gamma-ray transport can supply a range of possible material compositions, but reducing the differences between predicted and actual measurements can lead to false results. DREAM is a rapid technique for determining the most likely solution for several unknown parameters in an inverse transport problem. This work applies DREAM to a series of gamma spectroscopy experiments performed at ORNL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and application of processing and process control for nano-composite materials for lithium ion batteries (CRADA Final Report)

Oak Ridge National Laboratory and A123 Systems, Inc. collaborated on this project to develop a better understanding, quality control procedures, and safety testing for A123 System’s nanocomposite separator (NCS) technology which is a cell based patented technology and separator. NCS demonstrated excellent performance. x3450 prismatic cells were shown to survive >8000 cycles (1C/2C rate) at room temperature with greater than 80% capacity retention with only NCS present as an alternative to conventional polyolefin. However, for a successful commercialization, the coating conditions required to provide consistent and reliable product had not been optimized and QC techniques for being able to remove defective material before incorporation into a cell had not been developed. The work outlined in this report addresses these latter two points. First, experiments were conducted to understand temperature profiles during the different drying stages of the NCS coating when applied to both anode and cathode. One of the more interesting discoveries of this study was the observation of the large temperature decrease experienced by the wet coating between the end of the infrared (IR) drying stage and the beginning of the exposure to the convection drying oven. This is not a desirable situation as the temperature gradient could have a deleterious effect on coating quality. Based on this and other experimental data a radiative transfer model was developed for IR heating that also included a mass transfer module for drying. This will prove invaluable for battery coating optimization especially where IR drying is being employed. A stress model was also developed that predicts that under certain drying conditions tensile stresses are formed in the coating which could lead to cracking that is sometimes observed after drying is complete. Prediction of under what conditions these stresses form is vital to improving coating quality. In addition to understanding the drying process other parameters such as slurry quality and equipment optimization were examined. Removal of particles and gels by filtering, control of viscosity by %solids and mixing adjustments, removal of trapped gas in the slurry and modification of coater speed and slot die gap were all found to be important for producing uniform and flaw-free coatings. Second, an in-line Hi-Pot testing method has been developed specifically for NCS that will enable detection of coating flaws that could lead to soft or hard electrical shorts within the cell. In this way flawed material can be rejected before incorporation into the cell thus greatly reducing the amount of scrap that is generated. Improved battery safety is an extremely important benefit of NCS. Evaluation of battery safety is usually accomplished by conducting a variety of tests including nail penetration, hot box, over charge, etc. For these tests entire batteries must be built but the resultant temperature and voltage responses reveal little about the breakdown mechanism. In this report is described a pinch test which is used to evaluate NCS quality at various stages including coated anode and cathode as well as assembled cell. Coupled with post-microscopic examination of the damaged ‘pinch point’ test data can assist in the coating optimization from an improved end-use standpoint. As a result of this work two invention disclosures, one for optimizing drying methodology and the other for an in-line system for flaw detection, have been filed. In addition, 2 papers are being written for submission to peer-reviewed journals.

25 ENERGY STORAGE↗