Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPTICAL MODULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Reconstruction of the remote dipole and quadrupole fields from the kinetic Sunyaev Zel’dovich and polarized Sunyaev Zel’dovich effects

The kinetic Sunyaev Zel’dovich (kSZ) and polarized Sunyaev Zel’dovich (pSZ) effects are temperature and polarization anisotropies induced by the scattering of cosmic microwave background (CMB) photons from structure in the post-reionization universe. In the case of the kSZ effect, small angular scale anisotropies in the optical depth are modulated by the CMB dipole field, i.e., the CMB dipole observed at each spacetime point, which is sourced by the primordial dipole and especially the local peculiar velocity. In the case of the pSZ effect, similar small-scale anisotropies are modulated by the CMB quadrupole field, which receives contributions from both scalar and tensor modes. Statistical anisotropies in the cross-correlations of CMB temperature and polarization with tracers of the inhomogeneous distribution of electrons provide a means of isolating and reconstructing the dipole and quadrupole fields. In this paper, we present a set of unbiased minimum variance quadratic estimators for the reconstruction of the dipole and quadrupole fields, and forecast the ability of future CMB experiments and large-scale structure surveys to perform this reconstruction. Furthermore, consistent with previous work, we find that a high fidelity reconstruction of the dipole and quadrupole fields over a variety of scales is indeed possible, and demonstrate the sensitivity of the pSZ effect to primordial tensor modes. Using a principle component analysis, we estimate how many independent modes could be accessed in such a reconstruction. We also comment on a few first applications of a detection of the dipole and quadrupole fields, including a reconstruction of the primordial contribution to our locally observed CMB dipole, a test of statistical homogeneity on large scales from the first modes of the quadrupole field, and a reconstruction technique for the primordial potential on the largest scales.

79 ASTRONOMY AND ASTROPHYSICS↗

MO-FG-303-04: A Smartphone Application for Automated Mechanical Quality Assurance of Medical Accelerators

Purpose: The mechanical quality assurance (QA) of medical accelerators consists of a time consuming series of procedures. Since most of the procedures are done manually – e.g., checking gantry rotation angle with the naked eye using a level attached to the gantry –, it is considered to be a process with high potential for human errors. To remove the possibilities of human errors and reduce the procedure duration, we developed a smartphone application for automated mechanical QA. Methods: The preparation for the automated process was done by attaching a smartphone to the gantry facing upward. For the assessments of gantry and collimator angle indications, motion sensors (gyroscope, accelerator, and magnetic field sensor) embedded in the smartphone were used. For the assessments of jaw position indicator, cross-hair centering, and optical distance indicator (ODI), an optical-image processing module using a picture taken by the high-resolution camera embedded in the smartphone was implemented. The application was developed with the Android software development kit (SDK) and OpenCV library. Results: The system accuracies in terms of angle detection error and length detection error were < 0.1° and < 1 mm, respectively. The mean absolute error for gantry and collimator rotation angles were 0.03° and 0.041°, respectively. The mean absolute error for the measured light field size was 0.067 cm. Conclusion: The automated system we developed can be used for the mechanical QA of medical accelerators with proven accuracy. For more convenient use of this application, the wireless communication module is under development. This system has a strong potential for the automation of the other QA procedures such as light/radiation field coincidence and couch translation/rotations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser interferometric method for determining the carrier diffusion length in semiconductors

A new laser interferometric method for measuring the carrier diffusion length in semiconductors is proposed. The method is based on the interference–absorption interaction of two laser radiations in a semiconductor. Injected radiation generates additional carriers in a semiconductor, which causes a change in the material’s optical constants and modulation of the probing radiation passed through the sample. When changing the distance between carrier generation and probing points, a decrease in the carrier concentration, which depends on the diffusion length, is recorded. The diffusion length is determined by comparing the experimental and theoretical dependences of the probe signal on the divergence of the injector and probe beams. The method is successfully tested on semiconductor samples with different thicknesses and surface states and can be used in scientific research and the electronics industry.

36 MATERIALS SCIENCE↗

All-Electric Laser Beam Control Based on a Quantum-Confined Heterostructure with an Integrated Distributed Bragg Grating

The characteristics of semiconductor chip modulators providing the angular deflection of a laser beam due to all-electric modulation of the optical characteristics of a semiconductor heterostructure are theoretically studied. Designs for quantum-confined semiconductor waveguide heterostructures with a distributed Bragg reflector integrated on the heterostructure surface are developed. The design of a waveguide structure including 20 periods of coupled asymmetric quantum wells, which provide an optical confinement factor of the waveguide mode of 20%, and an optimized doping profile allowing a uniform electric-field distribution to be maintained in the quantum-well region in the entire range of operating voltages are proposed. In this waveguide structure, the change in the refractive index due to the quantum-confined Stark effect reaches 0.086 when the control signal changes from 0 to 6 V. It is shown that the spatial (angular) scanning of the laser beam emitted from the surface of a distributed Bragg mirror with a divergence of less than 0.1° in the range of 1°–2° is feasible for the proposed waveguide structure design.

36 MATERIALS SCIENCE↗

XRF-ROI Finder: Machine Learning to Guide Region-of-Interest Scanning for X-ray Fluorescence Microscopy

The ROI-finder software is being developed for use by several Microscopy Group beamlines at Argonne National Laboratory, including 2-ID microprobes and 9-ID-B Bionanoprobe which use multi-scale scanning fluorescence microscopy to acquire elemental maps (multi-modal image data). Microscopy experiments require scan of samples at a coarse resolution followed by ROI identification using feature detection based on domain expertise. Finer resolution scans are then conducted based on identified ROI. The decision-making process based on domain expertise will be difficult to perform for faster data rates and much larger sampling volumes anticipated after APS-U necessitating the need for the ROI-finder software. The ROI- finder detects regions of interest through a continuous learning process, starting with a unsupervised representation learning and improving its recommendations through supervised learning and an interactive tool for user annotation. The scope of ongoing development efforts includes the integration of image registration module to correlate optical and X-ray images, extraction of feature morphology as well as elemental signatures in the image space and incorporation of beamtime streaming data by the scanning probe via EPICS.

CHOWDHURY, M. ARSHAD ZAHANGIR↗

Precision Polishing of Spheres Via In-Situ Process Monitoring and Machine-Learning-Based Optimization

Precision polishing for high surface finish is a vital step in the making of many high-tech components for optical and semiconductor modules as well as for wide ranging experimental samples for HED science that is at the core of LLNL’s mission. In particular, the fabrication of extremely smooth and round spheres comprised of low atomic number materials (low-Z such as high-density carbon or HDC, beryllium, hydrocarbon polymers, etc.) for Inertial Confinement Fusion (ICF) is entirely reliant on specialized polishing processes to achieve the surface smoothness.

36 MATERIALS SCIENCE↗

Results from the DUNE ND-LAr 2x2 Demonstrator Run 2

The Deep Underground Neutrino Experiment (DUNE) is a cutting-edge, long-baseline experiment under construction in the United States, based on large liquid-argon time projection chambers (LArTPCs). The DUNE Near Detector LArTPC (ND-LAr) will employ a novel modular architecture using a pixelated LArPix charge readout. To validate this design and characterize detector response, the 2×2 demonstrator—an array of eight optically isolated LArTPC modules—was deployed at Fermilab in 2024. During winter 2025, the 2x2 demonstrator was operated for a second data-taking campaign (Run 2) with the aim of studying the low-energy response of the detector. Run 2 focused on calibration and response studies using a suite of deployed radioactive sources. Gamma sources (²²Na, ⁶⁰Co, and ⁸⁸Y) were used to probe module-to-module performance variations, energy resolution, and calibrations. Neutron sources (AmBe and a pulsed neutron generator) enabled studies of neutron interactions in liquid argon, including inelastic scatters and neutron capture signals, relevant for low-energy backgrounds and detector modeling. In addition, the detector was doped with ²²⁰Rn, providing Bi–Po coincidence signals that allow precise calibration of the charge and scintillation response. This poster will present results from these calibration campaigns. These studies provide critical validation of the ND-LAr modular LArTPC concept and inform calibration and reconstruction strategies for the full DUNE near detector.

Mora-Lepin, Luis [Florida State U.] (ORCID:0000000↗

HIGH PRECISION ROVIBRATIONAL SPECTROSCOPY OF OH{sup +}

The molecular ion OH{sup +} has long been known to be an important component of the interstellar medium. Its relative abundance can be used to indirectly measure cosmic ray ionization rates of hydrogen, and it is the first intermediate in the interstellar formation of water. To date, only a limited number of pure rotational transitions have been observed in the laboratory making it necessary to indirectly calculate rotational levels from high-precision rovibrational spectroscopy. We have remeasured 30 transitions in the fundamental band with MHz-level precision, in order to enable the prediction of a THz spectrum of OH{sup +}. The ions were produced in a water cooled discharge of O{sub 2}, H{sub 2}, and He, and the rovibrational transitions were measured with the technique Noise Immune Cavity Enhanced Optical Heterodyne Velocity Modulation Spectroscopy. These values have been included in a global fit of field free data to a {sup 3}Σ{sup −} linear molecule effective Hamiltonian to determine improved spectroscopic parameters which were used to predict the pure rotational transition frequencies.

74 ATOMIC AND MOLECULAR PHYSICS↗

Design of an optical fiber cable link for lightning instrumentation

A lightning instrumentation system was designed to record current magnitudes of lightning strikes that hit a launch pad service structure at NASA's Kennedy Space Center. The instrumentation system consists of a lightning ground rod with a current sensor coil, an optical transmitter, an optical fiber cable link, a detector receiver, and a recording system. The transmitter is a wideband pulse transformer driving an IR LED emitter. The transmitter operates linearly as a transducer. A low loss fiber bundle provides isolation of the recorder system from the electromagnetic field of the lightning strike. The output of an optical detector receiver module is sampled and recorded in digital format. The significant factors considered in the design were dynamic range, linearity, mechanical configuration, electromagnetic isolation, and temperature compensation.

Grove, C. H.↗

Capacity and cutoff rate of (M+1)-ary decision rules for noisy M-ary optical PPM channel

The channel capacity C and the cutoff rate R sub o of two (M + 1)-ary decision rules for noisy M slots/symbol optical pulse position modulation (PPM) with ideal photon counting are computed and compared. Also the values of the optimum thresholds needed to minimize the signal requirements are given. With a minor increase in hardware complexity, the symbol by symbol threshold decision rule is shown to be superior to the slot by slot threshold detection and decision rule in two aspects: first, it saves more than 0.5 dB in signal energy for the very noisy cases of more than one noise photon per slot (for low noise cases it also saves signal energy, but a negligibly small amount). Second, it is more robust to variations in the noise level.

Lee, P. J.↗

Thematic mapper flight model preshipment review data package. Volume 2, part A: Subsystem data

Performance and acceptance data are presented for the multiplexer, scan mirror, power supply, mainframe/top mechanical and the aft optics, assemblies. Other major subsystems evaluated include the relay optics, the electronic module, the radiative cooler, and the cable harness. Reference lists of nonconforming materials reports, failure reports, and requests for deviation/waiver are also given.

Source record↗

Real-time synthetic aperture radar processing

Real-time acousto-optic SAR processors are described and experimentally demonstrated. SAR imaging is performed in one of the architectures by applying the signal to an acousto-optic device and correlating it with chirp signals recorded on an optical transparency by time integration on a CCD detector. In a different implementation, the imaging is preformed by interfering the light beams diffracted from two separate acousto-optic devices, one modulated the radar signal and the second by the reference chirp waveform.

Psaltis, D.↗

The San Fernando Observatory video Stokes polarimeter

A study was conducted to determine the suitability of the San Fernando Observatory's 61 cm (24 inch) aperture vacuum solar telescope and 3 m (118 inch) focal length vacuum spectroheliograph for Stokes Polarimetry measurements. The polarization characteristics of these two instruments was measured by determining their Mueller matrices as a function of telescope orientation, field angle, wavelength, grating type, and position of the measuring beam in the telescope entrance window. In general, the polarizing and depolarizing properties are small so that inversion of the system Mueller matrix will permit the accurate measurement of Stokes profiles for vector magnetic field determination. A proposed polarimeter design based on the use of a TV camera system to simultaneously scan six different polarization components of a given line profile is described. This design, which uses no rotating optics or electronic modulators and makes efficient use of the available irradiance, promises to yield high quality vector magnetograms.

Richter, P. H.↗

Phase locked loop synchronization for direct detection optical PPM communication systems

Receiver timing synchronization of an optical pulse position modulation (PPM) communication system can be achieved using a phase locked loop (PLL) if the photodetector output is properly processed. The synchronization performance is shown to improve with increasing signal power and decreasing loop bandwidth. Bit error rate (BER) of the PLL synchronized PPM system is analyzed and compared to that for the perfectly synchronized system. It is shown that the increase in signal power needed to compensate for the imperfect synchronization is small (less than 0.1 dB) for loop bandwidths less than 0.1% of the slot frequency.

Chen, C. C.↗

Synchronization tracking in pulse position modulation receiver

A clock pulse generator for decoding pulse position modulation in an optical communication receiver is synchronized by a delay tracking loop which multiplies impulses of a data pulse by the square wave clock pulses from the generator to produce positive impulses when the clock pulse is of one level, and negative impulses when the clock pulse is of another level. A delay tracking loop integrates the impulses and produces an error signal that adjusts the delay so the clock pulses will be synchronized with data pulses. A dead-time tau sub d is provided between data pulses of an interval tau sub p in the data pulse period tau. When synchronized, the average number of positive impulses integrated will equal the average number of negative impulses over the continuous stream of data pulses.

Vilnrotter, Victor A.↗

Performance measurements of a diode laser optical communications link with Q = 4 PPM signaling

The theoretical and measured performance characteristics of a direct detection optical communication system are reported. The system consisted of a semiconductor diode laser, silicon avalanche photodiode detector, and used Q = 4 optical pulse position modulation signaling to transmit binary source data at a rate of 25 megabits/sec. Operation at a receiver bit error probability of 10 to the -6th was demonstrated at received signal energies corresponding to an average of 160 detected photons per PPM symbol, or 80 photons per source bit.

Sun, X.↗

Acousto-optical/Magneto-optical Correlator Or Convolver

Experimental system demonstrates optical processing of multiple channels of binary signals. One input channel contains signal that varies with time and applied to one-dimensional acousto-optical cell. Other input channel contains two-dimensional pattern that is stationary or can vary with time and applied to magneto-optical spatial light modulator. Output is time-varying correlation or convolution of first input with one of rows in second input.

Liu, Hua-Kuang↗