Search NASA⌕ Search

SEARCH · Search NASA

Results for “OUTAGES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Design of Refractory Linings for Balanced Energy Efficiency, Uptime, and Capacity in Lime Kilns

The rotary kilns used by the pulp and paper industry to regenerate lime in the Kraft process are very energy intensive. Throughout the 90 s, in response to increasing fuel prices, the industry used back up insulation in conjunction with the high alumina brick used to line the burning zones of their kilns. While this improved energy efficiency, the practice of installing insulating brick behind the working lining increased the inner wall temperatures. In the worst case, due to the increased temperatures, rapid brick failures occurred causing unscheduled outages and expensive repairs. Despite these issues, for the most part, the industry continued to use insulating refractory linings in that the energy savings were large enough to offset any increase in the cost of maintaining the refractory lining. Due to the dramatic decline in the price of natural gas in some areas combined with mounting pressures to increasing production of existing assets, over the last decade, many mills are focusing more on increasing the uptime of their kilns as opposed to energy savings. To this end, a growing number of mills are using basic (magnesia based) brick instead of high alumina brick to line the burning zone of the kiln since the lime mud does not react with these bricks at the operating temperatures of the burning zone of the kiln. In the extreme case, a few mills have chosen to install basic brick in the front end of the kiln running a length equivalent to 10 diameters. While the use of basic brick can increase the uptime of the kiln and reduce the cost to maintain the refractory lining, it does dramatically increase the heat losses resulting from the increased operating temperatures of the shell. Also, over long periods of time operating at these high temperatures, damage can occur in the shell. There are tradeoffs between energy efficiency, capacity and uptime. When fuel prices are very high, it makes sense to insulate the lining. When fuel prices are lower, trading some thermal efficiency for increased uptime and capacity seems reasonable. This paper considers a number of refractory linings in an effort to develop optimized operating strategies that balance these factors. In addition to considering a range of refractory materials, the paper examines other factors such as the chain area, discharge dams and other operating variables that impact the service life of the refractory lining. The paper provides recommendations that will help mill personnel develop a strategy to select a refractory lining that is optimized for their specific situation.

Computational Modeling↗

Incorporating Forecast Uncertainty in Utility Control Center

Uncertainties in forecasting the output of intermittent resources such as wind and solar generation, as well as system loads are not adequately reflected in existing industry-grade tools used for transmission system management, generation commitment, dispatch and market operation. There are other sources of uncertainty such as uninstructed deviations of conventional generators from their dispatch set points, generator forced outages and failures to start up, load drops, losses of major transmission facilities and frequency variation. These uncertainties can cause deviations from the system balance, which sometimes require inefficient and costly last minute solutions in the near real-time timeframe. This Chapter considers sources of uncertainty and variability, overall system uncertainty model, a possible plan for transition from deterministic to probabilistic methods in planning and operations, and two examples of uncertainty-based fools for grid operations.This chapter is based on work conducted at the Pacific Northwest National Laboratory (PNNL)

wind generation, solar generation, Energy managmen↗

Reliability and Geographic Trends of 50,000 Photovoltaic Systems in the USA: Preprint

This paper presents performance and reliability data from nearly 50,000 photovoltaic (PV) systems totaling 1.7 gigawatts installed capacity in the USA from 2009 to 2012 and their geographic trends. About 90% of the normal systems and about 85% of all systems, including systems with known issues, performed to within 10% or better of expected performance. Although considerable uncertainty may exist due to the nature of the data, hotter climates appear to exhibit some degradation not seen in the more moderate climates. Special causes of underperformance and their impacts are delineated by reliability category. Hardware-related issues are dominated by inverter problems (totaling less than 0.5%) and underperforming modules (totaling less than 0.1%). Furthermore, many reliability categories show a significant decrease in occurrence from year 1 to subsequent years, emphasizing the need for higher-quality installations but also the need for improved standards development. The probability of PV system damage because of hail is below 0.05%. Singular weather events can have a significant impact such as a single lightning strike to a transformer or the impact of a hurricane. However, grid outages are more likely to have a significant impact than PV system damage when extreme weather events occur.

14 SOLAR ENERGY↗

Understanding the Effect of Baseline Modeling Implementation Choices on Analysis of Demand Response Performance

Accurate evaluation of the performance of buildings participating in Demand Response (DR) programs is critical to the adoption and improvement of these programs. Typically, we calculate load sheds during DR events by comparing observed electric demand against counterfactual predictions made using statistical baseline models. Many baseline models exist and these models can produce different shed calculations. Moreover, modelers implementing the same baseline model can make different modeling implementation choices, which may affect shed estimates. In this work, using real data, we analyze the effect of different modeling implementation choices on shed predictions. We focused on five issues: weather data source, resolution of data, methods for determining when buildings are occupied, methods for aligning building data with temperature data, and methods for power outage filtering. Results indicate sensitivity to the weather data source and data filtration methods as well as an immediate potential for automation of methods to choose building occupied modes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Calculating Design Heating Loads for Superinsulated Buildings, Ithaca, New York; Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

Designing a superinsulated home has many benefits including improved comfort, reduced exterior noise penetration, lower energy bills, and the ability to withstand power and fuel outages under much more comfortable conditions than a typical home. Extremely low heating and cooling loads equate to much smaller HVAC equipment than conventionally required. Sizing the mechanical system to these much lower loads reduces first costs and the size of the distribution system needed. While these homes aren't necessarily constructed with excessive mass in the form of concrete floors and walls, the amount of insulation and the increase in the thickness of the building envelope can lead to a mass effect, resulting in the structures ability to store much more heat than a code built home. This results in a very low thermal inertia making the building much less sensitive to drastic temperature swings thereby decreasing the peak heating load demand. Alternative methods that take this inertia into account along with solar and internal gains result in smaller more appropriate design loads than those calculated using Manual J version 8. During the winter of 2013/2014, CARB monitored the energy use of three homes in climate zone 6 in an attempt to evaluate the accuracy of two different mechanical system sizing methods for low load homes. Based on the results, it is recommended that internal and solar gains be included and some credit for thermal inertia be used in sizing calculations for superinsulated homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Calculating Design Heating Loads for Superinsulated Buildings

Designing a superinsulated home has many benefits including improved comfort, reduced exterior noise penetration, lower energy bills, and the ability to withstand power and fuel outages under much more comfortable conditions than a typical home. Extremely low heating and cooling loads equate to much smaller HVAC equipment than conventionally required. Sizing the mechanical system to these much lower loads reduces first costs and the size of the distribution system needed. While these homes aren't necessarily constructed with excessive mass in the form of concrete floors and walls, the amount of insulation and the increase in the thickness of the building envelope can lead to a mass effect, resulting in the structures ability to store much more heat than a code built home. This results in a very low thermal inertia making the building much less sensitive to drastic temperature swings thereby decreasing the peak heating load demand. Alternative methods that take this inertia into account along with solar and internal gains result in smaller more appropriate design loads than those calculated using Manual J version 8. During the winter of 2013/2014, the Consortium for Advanced Residential Buildings team monitored the energy use of three homes in climate zone 6 in an attempt to evaluate the accuracy of two different mechanical system sizing methods for low load homes. Based on the results, it is recommended that internal and solar gains be included and some credit for thermal inertia be used in sizing calculations for superinsulated homes.

Building America↗

Water Network Tool for Resilience v. 1.0

WNTR is a python package designed to simulate and analyze resilience of water distribution networks. The software includes: - Pressure driven and demand driven hydraulic simulation - Water quality simulation to track concentration, trace, and water age - Conditional controls to simulate power outages - Models to simulate pipe breaks - A wide range of resilience metrics - Analysis and visualization tools

Source record↗

PNNL’s Shared Perspectives Technology

Shared Perspectives, one of the technologies within the PNNL-developed GridOPTICS capability suite, enables neighboring organizations, such as different electric utilities, to more effectively partner to solve outages and other grid problems. Shared Perspectives provides a means for organizations to safely stream information from different organizational service areas; the technology then combines and aligns this information into a common, global view, enhancing global situation awareness that can reduce the time it takes to talk through a problem and identify solutions. The technology potentially offers applications in other areas, such as disaster response; collaboration in the monitoring/assessment of real-time events (e.g., hurricanes, earthquakes, and tornadoes); as well as military uses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BENCHMARK ACCELERATED AGING OF HARVESTED HYPALON/EPR AND CSPE/XLPE POWER AND I&C CABLE IN NUCLEAR POWER PLANTS

As part of the Light Water Reactor and Sustainability (LWRS) program in the U.S. Department of Energy (DOE) Office of Nuclear Energy, material aging and degradation research is currently geared to support the long-term operation of existing nuclear power plants (NPPs) as they move beyond their initial 40 year licenses. The goal of this research is to provide information so that NPPs can develop aging management programs (AMPs) to address replacement and monitoring needs as they look to operate for 20 years, and in some cases 40 years, beyond their initial operating lifetimes. For cable insulation and jacket materials that support instrument, control, and safety systems, accelerated aging data are needed to determine priorities in cable aging management programs. Before accelerated thermal and radiation aging of harvested, representative cable insulation and jacket materials, the benchmark performance of a new test capability at Oak Ridge National Laboratory (ORNL) was evaluated for temperatures between 70 and 135 C, dose rates between 100 and 500 Gy/h, and accumulated doses up to 20 kGy, Samples that were characterized and are representative of current materials in use were harvested from the Callaway NPP near Fulton, Missouri, and the San Onofre NPP north of San Diego, California. From the Callaway NPP, a multiconductor control rod cable manufactured by Boston Insulated Wire (BIW), with a Hypalon/ chorolosulfonated polyethylene (CSPE) jacket and ethylene-propylene rubber (EPR) insulation, was harvested from the auxiliary space during a planned outage in 2013. This cable was placed into service when the plant was started in 1984. From the San Onofre NPP, a Rockbestos Firewall III (FRIII) cable with a Hypalon/ CSPE jacket with cross-linked polyethylene (XLPE) insulation was harvested from an on-site, climate-controlled storage area. This conductor, which was never placed into service, was procured around 2007 in anticipation of future operation that did not occur. Benchmark aging for both jacket and insulation material was carried out in air at a temperature of 125 C or in uniform 140 Gy/h gamma irradiation over a period of 60 days. Their mechanical properties over the course of their exposures were compared with reference data from comparable cable jacket/insulation compositions and aging conditions. For both accelerated thermal and radiation aging, it was observed that the mechanical properties for the Callaway BIW control rod cable were consistent with those previously measured. However, for the San Onofre Rockbestos FRIII, there was an observable functional difference for accelerated thermal aging at 125 C. Details on possible sources for this difference and plans for resolving each source are given in this paper.

Duckworth, Robert C↗

Utilizing Genetic Programming to Identify Failures in ICS Networks

Previously, researchers have attempted to apply machine learning techniques to network anomaly detection problems. Due to the staggering amount of variety that can occur in normal networks, the results have often been underwhelming. These challenges are far less pronounced when considering industrial control system (ICS) networks. The recurrent nature of these networks results in less noise and more consistent patterns for a machine learning algorithm to recognize. Here, we propose a method of evolving decision trees through genetic programming (GP) in order to detect network anomalies, such as device outages. Our approach extracts over a dozen features from network packet captures and netflows, normalizes them, and relates them in decision trees using fuzzy logic operators. Furthermore, the trees were used to detect three specific network events from three different points on the network across a statistically significant number of runs and achieved 100% accuracy on five of the nine experiments. When the trees attempted to detect more challenging events at points of presence further from the occurrence, the accuracy averaged to above 98%. Finally, using our method, all of the evolutionary cycles of the GP algorithm are computed a-priori, allowing the best resultant trees to be deployed as semi-real-time sensors with little overhead.

97 MATHEMATICS AND COMPUTING↗

Energy System Modeling with REopt

This poster details how REopt - NREL's software modeling platform for energy systems integration and optimization - can help to model energy systems. Some benefits of modeling with REopt include optimizing behind the meter storage for cost and resiliency, optimizing lab testing, optimizing dispatch of utility scale storage, and quantifying renewable energy impact on outage survivability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Defending the Power Grid from Hackers

A new initiative underway at the National Renewable Energy Laboratory is intended to prevent hackers from gaining control of parts of the nation's power grid, potentially damaging electrical equipment and causing localized power outages. Our nation's power grid is evolving to be more responsive to changing power needs, more able to integrate renewable energy, more efficient, and more reliable. One key element of this evolution is adding communication and control devices to the power grid, closer to the end user, so that utilities have greater situational awareness of the grid and can respond quickly to disturbances. But these new devices and their communications requirements can also open up the power grid to potential cyber attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Method of Synchrophasor Technology for Detecting and Analyzing Cyber-Attacks

Studying cybersecurity events and analyzing their impacts encourage planners and operators to develop innovative approaches for preventing attacks in order to avoid outages and other disruptions. This work considers two parts in security studies; detecting an integrity attack and examining its effects on power system generators. The detection was conducted through employing synchrophasor technology to provide authentication of ACG commands based on observed system operating characteristics. The examination of an attack is completed via a detailed simulation of a modified IEEE 68-bus benchmark model to show the associated power system dynamic response. The results of the simulation are discussed for assessing the impacts of cyber threats.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Architecture and Methods for Substation SCADA Cybersecurity: Best Practices

There are over 3000 electricity providers in the United States, encompassing investor and publicly owned utilities as well as electric cooperatives. There has been ongoing trends to increasingly automate and provide remote control and monitoring of electric energy delivery systems. The deployment of computer network technologies has increased the efficiency and reliability of electric power infrastructure. However, the increased use of digital communications has also increased the vulnerability to malicious cyber attacks [1]. In 2004 the National Research Councils (National Academies) formed a committee of specialists to address these vulnerabilities and propose possible solutions with an objective to prioritize the R&D needs for developing countermeasures. The committee addressed many potential concerns in the electric power delivery system and classified them based upon different criteria and presented recommendations to minimize the gap between the academic research directions and the needs of the electric utility industry. The complexity and diversity of the electric power delivery system in the U.S. has opened many ports for attackers and intruders [1]. This complexity and diversity is attributed to the fact that power delivery system is a network of substations, transmission and distribution lines, sub-networks of controlling, sensing and monitoring units, and human operator involvement for running the system [1]. Accordingly, any incident such as the occurrence of a fault or disturbance in this complex network cannot be deferred and should be resolved within an order of milliseconds, otherwise there is risk of large-scale outages similar to the occurrences in India and the U.S. in 2003 [2]. There are three main vulnerabilities in supervisory control and data acquisition (SCADA) systems commonly identified—physical vulnerability, cyber vulnerability and personal vulnerability [1]. In terms of cyber threats, SCADA systems are the most critical elements in the electric power grid in the U.S. Unauthorized access to a SCADA system could enable/disable unexpected equipment (such as disable the protection system or a circuit breaker) which could cause large scale disruptions of electric power delivery. This paper provides an overview of power system SCADA technologies in transmission substations (Section 2) and summarizes the best practices for implementing a cyber security program. After introducing SCADA system operations in Section 2, a description of the security challenges for SCADA systems is presented in Section 3. In Section 4, NECRC Critical Infrastructure Protection standards CIP-002 through CIP-009 are summarized. An overview of industry best practices is presented in Section 5.

97 MATHEMATICS AND COMPUTING↗

Recent Upgrades at the Safety and Tritium Applied Research Facility

This paper gives a brief overview of the Safety and Tritium Applied Research (STAR) facility operated by the Fusion Safety Program (FSP) at the Idaho National Laboratory (INL). FSP researchers use the STAR facility to carry out experiments in tritium permeation and retention in various fusion materials, including wall armor tile materials. FSP researchers also perform other experimentation as well to support safety assessment in fusion development. This lab, in its present two-building configuration, has been in operation for over ten years. The main experiments at STAR are briefly described. This paper discusses recent work to enhance personnel safety at the facility. The STAR facility is a Department of Energy less than hazard category 3 facility; the personnel safety approach calls for ventilation and tritium monitoring for radiation protection. The tritium areas of STAR have about 4 to 12 air changes per hour, with air flow being once through and then routed to the facility vent stack. Additional radiation monitoring has been installed to read the laboratory room air where experiments with tritium are conducted. These ion chambers and bubblers are used to verify that no significant tritium concentrations are present in the experiment rooms. Standby electrical power has been added to the facility exhaust blower so that proper ventilation will now operate during commercial power outages as well as the real-time tritium air monitors.

tritium facility upgrades↗

Robust PV Degradation Methodology and Application

The degradation rate plays an important role in predicting and assessing the long-term energy generation of PV systems. Many methods have been proposed for extracting the degradation rate from operational data of PV systems, but most of the published approaches are susceptible to bias due to inverter clipping, module soiling, temporary outages, seasonality, and sensor degradation. In this manuscript, we propose a methodology for determining PV degradation leveraging available modeled clear-sky irradiance data rather than site sensor data, and a robust year-over-year (YOY) rate calculation. We show the method to provide reliable degradation rate estimates even in the case of sensor drift, data shifts, and soiling. Compared with alternate methods, we demonstrate that the proposed method delivers the lowest uncertainty in degradation rate estimates for a fleet of 486 PV systems.

14 SOLAR ENERGY↗

REopt Lite Web Tool

NREL developed a free, publicly available web version of the REopt (TM) renewable energy integration and optimization platform called REopt Lite. REopt Lite recommends the optimal size and dispatch strategy for grid-connected photovoltaics (PV) and battery storage at a site. It also allows users to explore how PV and storage can increase a site's resiliency during a grid outage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ice Nucleating Particle Sources at Oliktok Point Field Campaign Report

The Ice Nucleating Particle Sources at Oliktok Point U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) facility field campaign focused on chemically characterizing springtime aerosol sources at Oliktok Point, Alaska. This work was completed to improve our understanding of air masses influencing the site and altering ice nucleating particle (INP) concentrations measured by Dr. Jessie Creamean of the National Oceanic and Atmospheric Administration (NOAA) during her coordinated, simultaneous ARM field campaign “Exploratory Ice Nucleation Measurements at Oliktok”. Together these ARM field campaigns comprised INPOP (Ice Nucleating Particles at Oliktok Point). The field campaign took place at the Oliktok Point Third ARM Mobile Facility (AMF3) site from March 1 to May 31, 2017. A Davis rotating uniform motion (DRUM) impactor was deployed to collect particles for offline analysis for single-particle chemical characterization (aerosol mixing state). Barring a few interruptions due to power outages at the site, daily samples (24-h duration) were collected for analysis by computer-controlled scanning electron microscopy with energy dispersive X-ray spectroscopy (CCSEM-EDX). Unfortunately our user facility grant at the Pacific Northwest National Laboratory (PNNL) Environmental Molecular Sciences Laboratory (EMSL) was placed on hold from October 2017 to February 2018, limiting our ability to do CCSEM-EDX, as our access is also limited at the Michigan Center for Materials Characterization. Therefore, only a subset of these samples were chosen in consultation with J. Creamean and analyzed by CCSEM-EDX. We have proposed to analyze additional samples, targeting samples collected during marine air masses, as part of our DOE Atmospheric System Research (ASR) proposal “Investigating marine and terrestrial aerosol processes and cloud ice nucleation during the Alaskan Arctic melt season”. The size-resolved aerosol mixing state data produced from the ARM field campaign represent the first of such observations in the springtime at Oliktok Point. Since this AMF3 site is located within the North Slope of Alaska (NSA) oil fields near Prudhoe Bay, the site is continually influenced by combustion emissions, with natural sources also contributing to the background aerosol population.

North Slope of Alaska, Oliktok Point, aerosols, or↗