Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational Amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Saturn's ringlets

This paper suggests that Saturn's magnetic field is, in part, responsible for the very fine-scale radial features, or ringlets, seen in the ring-system. The planet's dipole field interacts with slight radial variations in plasma density, and the operation of an instability segregates the magnetic flux and plasma in the ring-plane into narrow alternating zones. It is suggested that this mechanism may act by itself to give rise to the inner ringlets. It is believed that at greater radial distances it amplifies gravitational resonances.

Bastin, J. A.↗

The fundamental power coupler and pick-up of the 56 MHz SRF cavity for RHIC

A fundamental power coupler (FPC) is designed to provide fast tuning the 56MHz SRF cavity in RHIC. The FPC will be inserted from one of the chemical cleaning ports at the rear end of the cavity with magnetic coupling to the RF field. The size and the location of the FPC are decided based on the required operational external Q of the cavity. The cavity is beam driven, and the FPC is designed with variable coupling that would cover a range of power levels. It is thermally isolated from the base temperature of the cavity, which is 4.2K. A 1kW power amplifier will be used to close an amplitude control feedback loop. In this paper, we discuss the coupling factor of the FPC with the chosen design.

43 PARTICLE ACCELERATORS↗

The Regenerative Current Mirror: A Very Low Power Front-End Amplifier for Silicon Pixel Detectors

In pixelized detectors, reducing power consumption in the front end ASIC chips becomes a crucial demand. Optimization based on mature pre-amplifier schemes today is unlikely to bring sufficient improvements. A new CMOS front-end gain stage topology with very low power consumption called regenerative current mirror is developed to fulfill the demand. The circuit takes advantage of high speed performance of current amplification while operating with relatively low bias current. The regenerative current mirror uses a NMOS current mirror and a PMOS current mirror, both with nominal gain of 1, to form a loop-back topology that provides a positive feedback. An NMOS FET with an external adjustable voltage applied to it gate terminal is used to limit open loop gain of the current mirrors to be slightly lower than 1. This yields a net gain of the positive feedback loop to be much larger than 1 while operating the current mirrors under relatively low bias currents. Simulation shows that in 65 nm fabrication process, the power consumption of the gain stages suitable for silicon pixel detectors can be controlled < 10 micro-Watts per channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NASA Tech Briefs, July 2009

Topics covered include: Dual Cryogenic Capacitive Density Sensor; Hail Monitor Sensor; Miniature Six-Axis Load Sensor for Robotic Fingertip; Improved Blackbody Temperature Sensors for a Vacuum Furnace; Wrap-Around Out-the-Window Sensor Fusion System; Wide-Range Temperature Sensors with High-Level Pulse Train Output; Terminal Descent Sensor Simulation; A Robust Mechanical Sensing System for Unmanned Sea Surface Vehicles; Additive for Low-Temperature Operation of Li-(CF)n Cells; Li/CFx Cells Optimized for Low-Temperature Operation; Number Codes Readable by Magnetic-Field-Response Recorders; Determining Locations by Use of Networks of Passive Beacons; Superconducting Hot-Electron Submillimeter-Wave Detector; Large-Aperture Membrane Active Phased-Array Antennas; Optical Injection Locking of a VCSEL in an OEO; Measuring Multiple Resistances Using Single-Point Excitation; Improved-Bandwidth Transimpedance Amplifier; Inter-Symbol Guard Time for Synchronizing Optical PPM; Novel Materials Containing Single-Wall Carbon Nanotubes Wrapped in Polymer Molecules; Light-Curing Adhesive Repair Tapes; Thin-Film Solid Oxide Fuel Cells; Zinc Alloys for the Fabrication of Semiconductor Devices; Small, Lightweight, Collapsible Glove Box; Radial Halbach Magnetic Bearings; Aerial Deployment and Inflation System for Mars Helium Balloons; Steel Primer Chamber Assemblies for Dual Initiated Pyrovalves; Voice Coil Percussive Mechanism Concept for Hammer Drill; Inherently Ducted Propfans and Bi-Props; Silicon Nanowire Growth at Chosen Positions and Orientations; Detecting Airborne Mercury by Use of Gold Nanowires; Detecting Airborne Mercury by Use of Palladium Chloride; Micro Electron MicroProbe and Sample Analyzer; Nanowire Electron Scattering Spectroscopy; Electron-Spin Filters Would Offer Spin Polarization Greater than 1; Subcritical-Water Extraction of Organics from Solid Matrices; A Model for Predicting Thermoelectric Properties of Bi2Te3; Integrated Miniature Arrays of Optical Biomolecule Detectors; A Software Rejuvenation Framework for Distributed Computing; Kurtosis Approach to Solution of a Nonlinear ICA Problem; Robust Software Architecture for Robots; R4SA for Controlling Robots; Bio-Inspired Neural Model for Learning Dynamic Models; Evolutionary Computing Methods for Spectral Retrieval; Monitoring Disasters by Use of Instrumented Robotic Aircraft; Complexity for Survival of Living Systems; Using Drained Spacecraft Propellant Tanks for Habitation; Connecting Node; and Electrolytes for Low-Temperature Operation of Li-CFx Cells.

Source record↗

Fabrication of sensitive high Tc bolometers

The rapid change of resistance with temperature of high quality films of high T sub c superconductors can be used to make resistance thermometers with very low temperature noise. Measurements on c-axis yttrium barium copper oxide (YBCO) films have given a spectral intensity of temperature noise less than 4 times 10(exp -8) K/Hz(exp 1/2) at 10 Hz. Consequently, the opportunity exists to make useful bolometric infrared detectors that operate near 90 K which can be cooled with liquid nitrogen. The fabrication and measurement of two bolometer architectures are discussed. The first is a conventional bolometer which consists of a 3000 A thick YBCO film deposited in situ by laser ablation on top of a 500 A thick SrTiO3 thickness and diced into 1x1 mm(exp 2) bolometer chips. Gold black smoke was used as the radiation absorber. The voltage noise was less than the amplifier noise when the film was current biased. Optical measurements gave an NEP of 5 times 10(exp -11) W/Hz(exp 1/2) at 10 Hz. The second architecture is that of an antenna-coupled microbolometer which consists of a small (5x10 cubic microns) YBCO film deposited directly on a bulk substrate with a low thermal conductance (YSZ) and an impedance matched planar lithographed spiral or log-periodic antenna. This structure is produced by standard photolithographic techniques. Measurements gave an electrical NEP of 4.7 times 10(exp -12) W/Hz(exp 1/2) at 10 kHz. Measurements of the optical efficiency are in progress. The measured performance of both bolometers will be compared to other detectors operating at or above liquid nitrogen temperatures so as to identify potential applications.

Nahum, Michael↗

Terahertz quantum cascade VECSEL with watt-level output power

Here, we report a terahertz quantum-cascade vertical-external-cavity surface-emitting laser (QC-VECSEL) whose output power is scaled up to watt-level by using an amplifying metasurface designed for increased power density. The metasurface is composed of a subwavelength array of metal-metal waveguide antenna-coupled sub-cavities loaded with a terahertz quantum-cascade gain material. Unlike previously demonstrated THz QC-VECSELs, the sub-cavities operate on their third-order lateral modal resonance (TM 03 ), instead of their first-order (TM 01 ) resonance. This results in a metasurface with a higher spatial density of the gain material, leading to an increased output power per metasurface area. In pulsed mode operation, peak THz output powers up to 830 mW at 77 K and 1.35 W at 6 K are observed, while a single-mode spectrum and a low divergence beam pattern are maintained. In addition, piezoelectric control of the cavity length allows approximately 50 GHz of continuous, single-mode tuning without a significant effect on output power or beam quality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Cryogenic Dark Matter Search low ionization-threshold experiment

Over 80 years ago we discovered the presence of Dark Matter in our universe. Endeavors in astronomy and cosmology are in consensus with ever improving precision that Dark Matter constitutes an essential 27% of our universe. The Standard Model of Particle Physics does not provide any answers to the Dark Matter problem. It is imperative that we understand Dark Matter and discover its fundamental nature. This is because, alongside other important factors, Dark Matter is responsible for formation of structure in our universe. The very construct in which we sit is defined by its abundance. The Milky Way galaxy, hence life, wouldn't have formed if small over densities of Dark Matter had not caused sufficient accretion of stellar material. Marvelous experiments have been designed based on basic notions to directly and in-directly study Dark Matter, and the Cryogenic Dark Matter Search (CDMS) experiment has been a pioneer and forerunner in the direct detection field. Generations of the CDMS experiment were designed with advanced scientific upgrades to detect Dark Matter particles of mass O(100) GeV/c 2 . This mass-scale was set primarily by predictions from Super Symmetry. Around 2013 the canonical SUSY predictions were losing some ground and several observations (rather hints of signals) from various experiments indicated to the possibility of lighter Dark Matter of mass O(10) GeV/c 2 . While the SuperCDMS experiment was probing the regular parameter space, the CDMSlite experiment was conceived to dedicatedly search for light Dark Matter using a novel technology. "CDMSlite" stands for CDMS - low ionization threshold experiment. Here we utilize a unique electron phonon coupling mechanism to measure ionization generated by scattering of light particles. Typically signals from such low energy recoils would be washed under instrumental noise. In CDMSlite via generation of Luke-Neganov phonons we can detect the small ionization energies, amplified in phonon modes during charge transport. This technology allows us to reach very low thresholds and reliably measure and investigate low energy recoils from light Dark Matter particles. This thesis describes the physics behind CDMSlite, the experimental design and the first science results from CDMSlite operated at the Soudan Underground Laboratory.

79 ASTRONOMY AND ASTROPHYSICS↗

The Regenerative Current Mirror: A Very Low Power Front-End Amplifier for Silicon Pixel Detectors

In pixelized detectors, reducing power consumption in the front- end ASIC chips becomes a crucial demand. Optimization based on mature pre-amplifier schemes today is unlikely to bring sufficient improvements. A new CMOS front-end gain stage topology with very low power consumption called regenerative current mirror is developed to fulfill the demand. The circuit takes advantage of high-speed performance of current amplification while operating with relatively low bias current. The regenerative current mirror uses a NMOS current mirror and a PMOS current mirror, both with nominal gain of 1, to form a loop-back topology that provides a positive feedback. An NMOS FET with an external adjustable voltage applied to it gate terminal is used to limit open loop gain of the current mirrors to be slightly lower than 1. This yields a net gain of the positive feedback loop to be much larger than 1 while operating the current mirrors under relatively low bias currents. Simulation shows that in 65 nm fabrication process, the power consumption of the gain stages suitable for silicon pixel detectors can be controlled < 10 micro-Watts per channel. Another novel low-power circuit called Pseudo-Thyristor presented in another document will replace traditional discriminator and the Regenerative Current Mirror plus Pseudo- Thyristor will provide a full solution for the silicon pixel low-power frontend ASIC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Throughput Genome Releaser

In this study, we present the development of a High Throughput Genome Releaser, an innovative device addressing common challenges in screening PCR. This genome DNA releaser is designed for rapid, cost-effective, and efficient DNA extraction, optimized for subsequent PCR reactions. Our experimentation with various synthetic materials led us to select a particular type of plastic that mirrors the properties of glass cover slides, providing a smooth surface and effective compression capabilities. We engineered a 96-well device equipped with a 96-well plate and a top rod, operable both manually and automatically, which is compatible with widely used liquid-handling robot decks. This compatibility enhances ease of use in high-throughput PCR setups. Additionally, we developed software to support its automatic functions. The genome releaser facilitates the extraction of PCR-amplifiable genomic DNA from 96 samples within minutes, eliminates the need for extraction buffers, and is adaptable to a wide range of microorganisms and cells. This versatility could significantly advance biomanufacturing processes.

42 ENGINEERING↗

Basic memory module

Construction and electrical characterization of the 4096 x 2-bit Basic Memory Module (BMM) are reported for the Space Ultrareliable Modular Computer (SUMC) program. The module uses four 2K x 1-bit N-channel FET, random access memory chips, called array chips, and two sense amplifier chips, mounted and interconnected on a ceramic substrate. Four 5% tolerance power supplies are required. At the Module, the address, chip select, and array select lines require a 0-8.5 V MOS signal level. The data output, read-strobe, and write-enable lines operate at TTl levels. Although the module is organized as 4096 x 2 bits, it can be used in a 8196 x 1-bit application with appropriate external connections. A 4096 x 1-bit organization can be obtained by depopulating chips.

Tietze, F. C.↗

Solid state Ku-band spacecraft transmitters

A transmitter is considered that consists of GaAs IMPATT and Read diodes operating in a microstrip circuit environment to provide amplification with a minimum of 63 db small signal gain and a minimum compressed gain at 5 W output of 57 db. Reported are Schottky-Read diode design and fabrication, microstrip and circulator optimization, preamplifier development, power amplifier development, dc-to-dc converter design, and integration of the breadboard transmitter modules. A four-stage power amplifier in cascade with a three-stage preamplifier had an overall gain of 56.5 db at 13.5 GHz with a power output of 4.5 W. A single-stage Read amplifier delivered 5.9 W with 4 db gain at 22% efficiency.

Wisseman, W. R.↗

Diamond shines in high-power devices

The 20-W S-band power amplifiers aboard the GOES E and F spacecraft exemplify the problems that type-IIa diamond heat sinks have been developed to solve, including the requirement for junction temperatures to be kept below 125 C. Diamond heat sinks allow high power S-band semiconductors to operate at a flange temperature of 70 C without exceeding the stipulated maximum junction temperature. Type-IIA diamond, which is an excellent electrical insulator, possesses a thermal conductivity four times better than pure copper at 100 C, and outperforms BeO by an even greater margin. Higher costs are offset by high reliability. Attention is presently given to the results of tests conducted by the NASA Goddard Space Flight Center.

Line, L.↗

Local oscillator induced degradation of medium-term stability in passive atomic frequency standards

As the performance of passive atomic frequency standards improves, a new limitation is encountered due to frequency fluctuations in an ancillary local oscillator (L.O.). The effect is due to time variation in the gain of the feedback which compensates L.O. frequency fluctuations. The high performance promised by new microwave and optical trapped ion standards may be severely compromised by this effect. Researchers present an analysis of this performance limitation for the case of sequentially interrogated standards. The time dependence of the sensitivity of the interrogation process to L.O. frequency fluctuations is evaluated for single-pulse and double-pulse Ramsey RF interrogation and for amplitude modulated pulses. The effect of these various time dependencies on performance of the standard is calculated for an L.O. with frequency fluctuations showing a typical 1/f spectral density. A limiting 1/sq. root gamma dependent deviation of frequency fluctuations is calculated as a function of pulse lengths, dead time, and pulse overlap. Researchers also present conceptual and hardware-oriented solutions to this problem which achieve a much more nearly constant sensitivity to L.O. fluctuations. Solutions involve use of double-pulse interrogation; alternate interrogation of multiple traps so that the dead time of one trap can be covered by operation of the other; and the use of double-pulse interrogation for two traps, so that during the time of the RF pulses, the increasing sensitivity of one trap tends to compensate for the decreasing sensitivity of the other. A solution making use of amplified-modulated pulses is also presented which shows nominally zero time variation.

Dick, G. John↗

NASA Tech Briefs, June 2010

Topics covered include: Situational Awareness from a Low-Cost Camera System; Data Acquisition System for Multi-Frequency Radar Flight Operations Preparation; Mercury Toolset for Spatiotemporal Metadata; Social Tagging of Mission Data; Integrating Radar Image Data with Google Maps; Demonstration of a Submillimeter-Wave HEMT Oscillator Module at 330 GHz; Flexible Peripheral Component Interconnect Input/Output Card; Interface Supports Lightweight Subsystem Routing for Flight Applications; MMIC Amplifiers and Wafer Probes for 350 to 500 GHz; Public Risk Assessment Program; Particle Swarm Optimization Toolbox; Telescience Support Center Data System Software; Update on PISCES; Ground and Space Radar Volume Matching and Comparison Software; Web-Based Interface for Command and Control of Network Sensors; Orbit Determination Toolbox; Distributed Observer Network; Computer-Automated Evolution of Spacecraft X-Band Antennas; Practical Loop-Shaping Design of Feedback Control Systems; Fully Printed High-Frequency Phased-Array Antenna on Flexible Substrate; Formula for the Removal and Remediation of Polychlorinated Biphenyls in Painted Structures; Integrated Solar Concentrator and Shielded Radiator; Water Membrane Evaporator; Modeling of Failure for Analysis of Triaxial Braided Carbon Fiber Composites; Catalyst for Carbon Monoxide Oxidation; Titanium Hydroxide - a Volatile Species at High Temperature; Selective Functionalization of Carbon Nanotubes: Part II; Steerable Hopping Six-Legged Robot; Launchable and Retrievable Tetherobot; Hybrid Heat Exchangers; Orbital Winch for High-Strength, Space-Survivable Tethers; Parameterized Linear Longitudinal Airship Model; and Physics of Life: A Model for Non-Newtonian Properties of Living Systems.

Source record↗

A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level

Abstract The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a photocathode operating in a semi-transparent mode and a Micromegas amplification structure. The first proof of concept single-channel prototype was able to achieve a time resolution below 25 ps. One of the crucial aspects in the development of precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm 2 suffered from degraded timing resolution due to the non-uniformity of the preamplification gap thickness. A new 100 cm 2 detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over the measured pads and a time resolution below 25 ps. More recent measurements with a thinner drift gap detector module and newly developed RF pulse amplifiers show that the pad centre resolution can be enhanced to the level of 17 ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.

Utrobicic, A.↗

Status of Electronics Upgrades to the LANL Green is Clean Phoswich Detector Systems - 16419

Los Alamos National Laboratory radiological facilities produce low-density room trash that, in many cases, is not contaminated with radioactivity. It has been estimated that 50 to 90% of low-density room trash is free of radioactive contamination and eligible for inclusion in LANL's Green is Clean (GIC) program. The GIC program is a verification program for non-regulated waste from radiation controlled areas that has been actively segregated as nonradioactive through the use of the waste generator's acceptable knowledge. The GIC program has employed two large area Phoswich gamma ray detector systems (HERCULES and ZEUS) to assay and verify that GIC candidate waste meets free release disposal requirements. The large area (127 cm{sup 2}) Phoswich detectors consist of a thin NaI front crystal (3 mm thick) that is optically coupled to a thick CsI back crystal (50 mm thick). The crystals are set in an oxygen-free high-conductivity copper housing with a very thin (0.025 mm) aluminum entrance window. The scintillation properties of the two crystals are different enough to allow the system's electronic components to identify the origin of any pulse. The original systems utilize Nuclear Instrumentation Module (NIM) electronics to process the detector signals. These electronic modules provide the buffering, amplification, and pulse shape analyzer needed for the proper presentation of signals to the custom Phosmux router module. The router module separates the sodium iodide and cesium iodide signals by their rise times and transfers this information into the computer-mounted multichannel analyzer, a Canberra Model S-100 system. While these NIM Bin counting electronics configurations have been effective for approximately 20 years of operation, they are bulky requiring numerous modules per detector and the important Phosmux module is no longer manufactured by LANL. Modern advancement of commercial counting electronics now offer more compact options for equivalent detector signal processing. A pulse shape discriminator module, the DGF Pixie-4, made by XIA LLC, has been identified that can replace the majority of the original NIM bin electronics in a much more compact chassis - one Pixie-4 replaces four NIM amplifiers and four NIM PSAs and fits in a small National Instruments{sup TM} chassis. Thus, LANL has initiated a system upgrade project to replace the historic NIM electronics with the XIA Pixie4 and associated configuration software. The hardware for one Phoswich systems has been procured for the project and the configuration software, customized for the LANL Phoswich detector application, has been written by the manufacturer. Initial setup and optimization of the Pixie-4 configuration has been performed. Qualitative and quantitative baseline comparisons to the NIM electronics has been performed. Good agreement of key low energy gamma lines between the systems has allowed 'Proof of Concept' to be concluded. Further optimization and performance evaluations are in progress. Modifications to the LabVIEW{sup TM} based operating software (originally written by VI Control Systems Ltd.) are being performed by a LANL LabVIEW{sup TM} programmer to accommodate the electronics upgrade. A new LabVIEW{sup TM} interface to control the Pixie-4 has already been developed. Final optimization and testing, formal software QA, and revisions to operating procedures are in progress to achieve completion of the GIC system upgrade project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Removing numerical pathologies in a turbulence parameterization through convergence testing

Discretized numerical models of the atmosphere are usually intended to faithfully represent an underlying set of continuous equations, but this necessary condition is violated sometimes by subtle pathologies that have crept into the discretized equations. Such pathologies can introduce undesirable artifacts, such as sawtooth noise, into the model solutions. The presence of these pathologies can be detected by numerical convergence testing. This study employs convergence testing to verify the discretization of the Cloud Layers Unified By Binormals (CLUBB) model of clouds and turbulence. That convergence testing identifies two aspects of CLUBB's equation set that contribute to undesirable noise in the solutions. First, numerical limiters (i.e. clipping) used by CLUBB introduce discontinuities or slope discontinuities in model fields. Second, this noise can be amplified by an advective term in CLUBB's background diffusion. Smoothing the limiters and removing the advective component of the background diffusion reduces the noise and restores the expected first-order convergence in CLUBB's solutions. These model reformulations improve the results at coarser, near-operational grid spacing and time step in cumulus cloud and dry turbulence tests. In addition, convergence testing is proved to be a valuable tool for detecting pathologies, including unintended discontinuities and grid dependence, in the model equation set.

Mathematics and Computing, Geosciences↗

Q-switched Erbium-doped fiber laser at 1600 nm for photoacoustic imaging application

We present a nanosecond Q-switched Erbium-doped fiber (EDF) laser system operating at 1600 nm with a tunable repetition rate from 100 kHz to 1 MHz. A compact fiber coupled, acousto-optic modulator-based EDF ring cavity was used to generate a nanosecond seed laser at 1600 nm, and a double-cladding EDF based power amplifier was applied to achieve the maximum average power of 250 mW. In addition, 12 ns laser pulses with the maximum pulse energy of 2.4 μJ were obtained at 100 kHz. Furthermore, the Stokes shift by Raman scattering over a 25 km long fiber was measured, indicating that the laser can be potentially used to generate the high repetition rate pulses at the 1.7 μm region. Finally, we detected the photoacoustic signal from a human hair at 200 kHz repetition rate with a pulse energy of 1.2 μJ, which demonstrates that a Q-switched Er-doped fiber laser can be a promising light source for the high speed functional photoacoustic imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗