Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational Reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

A Testbed Environment for Buildings-to-Grid Cyber Resilience Research and Development

The Smart Grid is characterized by the proliferation of advanced digital controllers at all levels of its operational hierarchy from generation to end consumption. Such controllers within modern residential and commercial buildings enable grid operators to exercise fine-grained control over energy consumption through several emerging Buildings-to-Grid (B2G) applications. Though this capability promises significant benefits in terms of operational economics and improved reliability, cybersecurity weaknesses in the supporting infrastructure could be exploited to cause a detrimental effect and this necessitates focused research efforts on two fronts. First, the understanding of how cyber attacks in the B2G space could impact grid reliability and to what extent. Second, the development and validation of cyber-physical application-specific countermeasures that are complementary to traditional infrastructure cybersecurity mechanisms for enhanced cyber attack detection and mitigation. The PNNL B2G testbed is currently being developed to address these core research needs. Specifically, the B2G testbed combines high-fidelity buildings+grid simulators, industry-grade building automation and Supervisory Control and Data Acquisition (SCADA) systems in an integrated, realistic, and reconfigurable environment capable of supporting attack-impact-detection-mitigation experimentation. In this paper, we articulate the need for research testbeds to model various B2G applications broadly by looking at the end-to-end operational hierarchy of the Smart Grid. Finally, the paper not only describes the architecture of the B2G testbed in detail, but also addresses the broad spectrum of B2G resilience research it is capable of supporting based on the smart grid operational hierarchy identified earlier.

Sridhar, Siddharth↗

Technology-Enabled Risk-Informed Maintenance Strategy to Minimize Operation and Maintenance Costs

The domestic fleet of nuclear power plants (NPPs) is facing a unique economic sustainability challenge in today’s energy market due to high total operating costs. One of the major contributors to the total operating cost of an NPP is the operations and maintenance (O&M) budget, which includes labor-intense preventive maintenance (PM) programs. PM programs involve manually performing inspection, calibration, testing, and maintenance of plant assets at periodic frequencies, as well as time-based replacement of assets, irrespective of individual asset condition. This approach, combined with the push to achieve high capacity factors, has resulted in a labor-centric business model. It is time to transition from this labor-centric business model to a technology-centric business model that will enable an optimal maintenance strategy by eliminating unnecessary costs associated with time-based PM activities. To enable this transition, the commercial nuclear industries are utilizing and developing reliable methodologies, based on available state of the art technologies, which facilitate assessing equipment condition and the dynamic risk of failure. The U.S. Department of Energy’s Idaho National Laboratory (INL) under the Light Water Reactor Sustainability (LWRS) Program is partnering with PKMJ Technical Services and Public Service Enterprise Group (PSEG) Nuclear, LLC to develop and demonstrate a deployable risk-informed predictive maintenance strategy to eliminate unnecessary O&M costs for an identified plant system, laying the foundation for scale-up to the entire plant. Recently developed technologies such as advanced wireless and wired sensors, data analytics, and risk assessment methodologies will support this transition. The technology-centric O&M model will result in significant automation and lay the foundation for real-time condition assessment of plant assets, thus enabling condition-based maintenance and enhancing plant safety, reliability, and economics of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy 101: Energy Efficient Data Centers

Data centers provide mission-critical computing functions vital to the daily operation of top U.S. economic, scientific, and technological organizations. These data centers consume large amounts of energy to run and maintain their computer systems, servers, and associated high-performance components—up to 3% of all U.S. electricity powers data centers. And as more information comes online, data centers will consume even more energy. Data centers can become more energy efficient by incorporating features like power-saving "stand-by" modes, energy monitoring software, and efficient cooling systems instead of energy-intensive air conditioners. These and other efficiency improvements to data centers can produce significant energy savings, reduce the load on the electric grid, and help protect the nation by increasing the reliability of critical computer operations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhanced Component Performance Study: Motor Operated Valves 1998–2022

This report presents an enhanced performance evaluation of motor-operated valves (MOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2022 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MOV failure modes considered are fail to open or close (FTOC), fail to operate or control (FTOP), and spurious operation (SO). The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trend was identified for MOVs for the most recent 10-year period: • Low-demand MOV frequency of FTOC demands (demands per reactor year). The following decreasing trends were identified for MOVs for the most recent 10-year period: • Low-demand MOV FTOC failure probability • Low-demand MOV frequency of FTOC events (failures per reactor year).

99 GENERAL AND MISCELLANEOUS↗

Enhanced Component Performance Study: Motor-Operated Valves 1998-2020

This report presents an enhanced performance evaluation of motor-operated valves (MOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2020 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MOV failure modes considered are fail to open or close (FTOC), fail to operate or control (FTOP), and spurious operation (SO). The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trend was identified for MOVs for the most recent 10-year period: • Low-demand MOV frequency of FTOC demands (demands per reactor year). The following increasing trends were identified for MOVs for the most recent 10-year period: • Low-demand MOV FTOC failure probability • Low-demand MOV frequency of FTOC events (failures per reactor year).

99 GENERAL AND MISCELLANEOUS↗

An Introduction to Grid Services: Concepts, Technical Requirements, and Provision from Wind

As the role of wind energy grows in the U.S. power grid, there is increased interest and requirements for it to provide 'essential reliability' services (historically often referred to as 'ancillary' services). These services are critical to maintaining the reliability and stability of the grid, and historically were provided by large 'synchronous' generators, mainly fossil-fueled and hydroelectric generators. To help evaluate the potential role of wind in providing these services, this report provides an overview of services provided to the grid, including their technical requirements, quantities currently procured, and some estimates of costs. The report also summarizes the technical and regulatory issues around wind providing these services.

17 WIND ENERGY↗

An Introduction to Grid Services: Concepts, Technical Requirements, and Provision from Wind

As the role of wind energy grows in the U.S. power grid, there is increased interest and requirements for it to provide 'essential reliability' services (historically often referred to as 'ancillary' services). These services are critical to maintaining the reliability and stability of the grid, and historically were provided by large 'synchronous' generators, mainly fossil-fueled and hydroelectric generators. To help evaluate the potential role of wind in providing these services, this report provides an overview of services provided to the grid, including their technical requirements, quantities currently procured, and some estimates of costs. The report also summarizes the technical and regulatory issues around wind providing these services.

17 WIND ENERGY↗

Enhanced Component Performance Study: Air Operated Valves 1998–2022

This report presents an enhanced performance evaluation of air operated valves (AOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2022 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The AOV failure modes considered are fail to open or close (FTOC), fail to operate or control (FTOP), and spurious operation (SO). The component reliability estimates and the reliability data are trended for the most recent 10 year period while yearly estimates for reliability are provided for the entire study period. The following increasing trends were identified for AOVs for the most recent 10 year period: • Low demand AOV frequency of FTOC demands (demands per reactor year) • High demand AOV frequency of FTOC demands. The following decreasing trends were identified for AOVs for the most recent 10 year period: • Low demand AOV FTOC failure probability • Low demand AOV FTOP failure rate • Low demand AOV frequency of FTOC events (failures per reactor year) • Low demand AOV frequency of FTOP events.

99 GENERAL AND MISCELLANEOUS↗

Evaluation of Concentrated Piperazine for CO 2 Capture from Coal-Fired Flue Gas (Final Report, REV0)

Concentrated piperazine (PZ) is a novel solvent being developed by the University of Texas at Austin (UT) for CO 2 capture from coal-fired power plants. The high thermal stability of PZ permits solvent regeneration at higher temperature (150 °C) and pressure, reducing compression capital and operating costs. The purpose of Cooperative Agreement DE-FE0005654, Evaluation of Concentrated Piperazine for CO 2 Capture from Coal-Fired Flue Gas , was to gain operational experience using PZ solvent to absorb CO 2 and explore novel, high-temperature processes for solvent regeneration. The pilot-scale test campaigns funded under this project have resulted in the continual improvement in the heat duty of the regeneration systems and solvent and equipment optimization. This document summarizes the results from the Phase 1 (2011, 2013 and 2015) and Phase 2 (2018) test campaigns. In Phase 1, the campaign was conducted on synthetic flue gas at the University of Texas’ Separations Research Program (SRP) facility to investigate CO 2 capture with 5 and 8 molal (5$m$ and 8$m$) PZ and two-stage flash (2SF) and advanced flash stripper (AFS) regeneration designs. Phase 1 testing also investigated techniques for measuring amine aerosol that can be generated during operation, and the effect of absorber operating conditions and sulfur containing compounds in the flue gas on aerosol generation. This testing showed that the AFS represents an optimized amine regeneration system with superior energy performance and simple operability over the 2SF or a simple stripper (SS), that 5$m$ PZ provides an economic and operability advantage over 8$m$ PZ, and that phase doppler interferometry (PDI) can provide useful particle size information on amine aerosol. In Phase 2, the campaign was conducted on coal-fired flue gas at the National Carbon Capture Center (NCCC) to investigate CO 2 capture with 5$m$ PZ and the AFS. The PZ solvent was also used with an existing SS at the NCCC to provide comparison with the AFS performance. Additionally, the campaign investigated the effect of flue gas SO 3 on amine aerosol from the CO 2 absorber. The NCCC pilot plant testing demonstrated the robustness of the PZ solvent and the high energy performance of the AFS provided significant improvements in energy performance over the conventional SS for PZ and other solvents, and approached the DOE’s economic targets for second generation carbon capture technologies. Extended testing allowed the project team to demonstrate reliable long-term operation of this novel regeneration technology and solvent combination. EPRI, Luminant, B&W, LG&E, Chevron, Southern Company, and UT are project co-funders. UT and Trimeric were project team members. URS Group was the prime contractor.

20 FOSSIL-FUELED POWER PLANTS↗

Energy Storage and Generation for Extreme Temperature and Pressure and Directional Measurement While Drilling Applications

FastCAP Systems Corporation has successfully completed all milestones defined by the award DE-EE0005503. Under this program, FastCAP developed three critical subassemblies to TRL3 demonstrating proof of concept of a geothermal MWD power source. This power source includes an energy harvester, electronics and a novel high temperature ultracapacitor (“ultracap”) rechargeable energy storage device suitable for geothermal exploration applications. FastCAP’s ruggedized ultracapacitor (ultracap) technology has been proven and commercialized in oil and gas exploration operating to rated temperatures of 150°C. Characteristics of this technology are that it is rechargeable and relatively high power. This technology was the basis for the advancements in rechargeable energy storage under this project. The ultracap performs reliably at 250°C and beyond and operates over a wide operating temperature range: -5°C to 250°C. The ultracap has significantly higher power density than lithium thionyl chloride batteries, a non-rechargeable incumbent used in oil and gas drilling today. Several hermetically sealed, prototype devices were tested in our laboratories at constant temperatures of 250°C showing no significant degradation over 2000 hours of operation. Other prototypes were tested at Sandia National Lab in the month of April, 2015 for a third party performance validation. These devices showed outstanding performance over 1000 hours of operation at three rated temperatures, 200°C, 225°C and 250°C, with negligible capacitance degradation and minimal equivalent series resistance (ESR) increase. Similarly, FastCAP’s ruggedized electronics have been proven and commercialized in oil and gas exploration operating to rated temperatures of 150°C. This technology was the basis for the advancements in downhole electronics under this project. Principal contributions here focused on design for manufacture innovations that have reduced the prototype build cycle time by a factor of 10x. The electronics have demonstrated a substantially reduced design cycle time by way of process and material selection innovations and have been qualified for 250°C / 10 Grms for at least 200 hours. FastCAP has also invented a rotary inertial energy generator (RIEG) to harvest various mechanical energy sources that exist downhole. This device is flow-independent and has been demonstrated as a proof of concept to survive geothermal well temperatures under this project. The herein energy harvester has been developed to provide operational power by harvesting rotational mechanical energy that exists downhole in geothermal drilling. The energy harvester has been tested at 250°C / 10 Grms for 200 hours. Deployment of these technologies in geothermal drilling and exploration applications could have an immediate and significant impact on the effectiveness and efficiency of drilling processes, particularly with regard to use of advanced logging and monitoring techniques. The ultimate goal of this work is to reduce drilling risk to make geothermal energy more attractive and viable to the customer. Generally speaking, we aim to support the transfer of MWD techniques from oil and gas to geothermal exploration with considerations toward the practical differences between the two. One of the most significant obstacles to the deployment of advanced drilling and production techniques in the geothermal context are limitations related to the maximum operating temperatures of downhole batteries used to provide power for downhole sensors, steering tools, telemetry equipment and other MWD/LWD technologies. FastCAP’s higher temperature ultracapacitor technology will provide power solutions for similar advanced drilling and production techniques, even in the harsher environments associated with geothermal energy production. This ultracapacitor will enable downhole power solutions for the geothermal industry capable of the same reliable and safe operation our team has demonstrated in the oil and gas context. Without batteries, geothermal MWD is left without a downhole power source. Some very high temperature turbines exist but provide unsteady, intermittent power and no power when the flow is off. In high loss formations common to geothermal exploration, it will be auspicious to support air drilling in which case there is no flow to power a turbine at all. In the best case, rechargeable energy storage will help to buffer unsteady power from non-battery power sources and in the worst case it will be needed to store energy from highly intermittent sources to provide a continuously operable power source to the tool.

15 GEOTHERMAL ENERGY↗

Standing Up a Narcotic Confirmation Laboratory for the Russian Federation Ministry of Defense Nuclear Personnel Reliability Program

Through a cooperative effort between the U. S. Department of Energy and the Russian Federation (RF) Ministry of Defense (MOD) a Personnel Reliability Program (PRP) for the nuclear handlers within the RF MOD has been implemented. A key element in the RF MOD PRP is the detection and confirmation of narcotic use in subject military and civilian personnel. This paper describes the process of narcotics screening and testing in the RF MOD and explains the confirmation process once screening has shown a positive result. Issues of laboratory certification, employee certification, employee training, sample chain-of-custody, and equipment needs will be addressed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermomechanical Reliability Investigation of Large Temperature Excursions in Power Electronics Packages

This study confirms that high stresses between the metallization layer and ceramic lead to significant failures in DBC substrate. The driving forces behind several different failure modes are discussed. Further understanding of these failure mechanisms enables the modules to be engineered for longtime operation and helps to enhance the reliability of system-level operation.

36 MATERIALS SCIENCE↗

Wireless Sensor Modalities at a Nuclear Plant Site to Collect Vibration Data

One of the major contributors to the total operating costs of domestic nuclear fleet of reactors today is the operation and maintenance (O&M) costs. These include labor-intense preventive maintenance programs involving manually-performed inspection, calibration, testing, and maintenance of plant assets at periodic frequency and time-based replacement of assets at periodic frequency, irrespective of their conditions. This has resulted in a labor-centric business model to achieve high capacity factors. To build an optimal maintenance program, it’s time to transition from this labor-centric business model to a technology-centric business model. Fortunately, there are technologies (advanced sensor, data analytics, and risk assessment methodologies) that will support this transition. The technology-centric business model will result in significant plant life extension and reduction of time-based maintenance activities. This will drive down O&M costs as labor is a rising cost and technology is a declining cost. This approach will lay the foundation for real-time condition assessment of plant assets, allowing condition-based maintenance to enhance plant safety, reliability, and economics of operation. The goal of this project is to address challenges in the area of digital monitoring, i.e., the application of advanced sensor technologies (particularly wireless sensor technologies) and science-based data analytic capabilities to advance online monitoring and predictive maintenance in nuclear plants to improve plant performance (efficiency gain and economic competitiveness). To achieve the project goal, in partnership with Exelon Generating Company (Exelon), researchers from Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) are performing research and development (R&D) to demonstrate application of wireless sensors using the distributed antenna system and advanced data analytics to achieve predictive maintenance. In the report, wireless vibration sensors, vibration data and its indicator are described. The wireless vibration sensors presented in this report support three types of wireless communication, namely, Wi-Fi, cellular, and 900 MHz. These wireless vibration sensors are considered by partner plant site for installation on plant asset to enable online vibration monitoring to replace periodic measurements. These vibration data along with other plant process data will be utilized to develop diagnostic and prognostic models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of Microgrid Algorithms using At-Scale Simulation and Emulation Real-Time (ASSERT) Framework

This paper presents a novel framework for validating microgrid algorithms using a At-Scale Simulation and Emulation Real-Time (ASSERT) setup. The proposed universal microgrid validation framework was developed at Advanced Research on Integrated Energy Systems (ARIES) platform at National Renewable Energy Laboratory in Golden, Colorado, USA. As the number of intercommunicating devices grow in power systems, along with more integration of inverter-based resources, developing and validating microgrid operation and control algorithms is becoming complex and time-consuming task. The ASSERT framework is designed to provide a comprehensive, accurate, and efficient solution for validating microgrid algorithms. It combines at-scale simulations and real-time emulation to create a virtual environment that closely mimics the behavior of a physical microgrids which are characteristic of future smart distribution systems, such as: (1) increasing variability in the physical size of new energy technologies; (2) requiring control large numbers of interconnected devices, and (3) integrating diverse technologies that have not previously worked together. The paper describes the technical details of the ASSERT framework, its validation process, and its benefits over traditional validation methods. The framework's ability to validate the performance of various algorithms is demonstrated through a case study, which shows that it can effectively identify the weaknesses of an algorithm and optimize its performance. Overall, the ASSERT framework is a promising tool that can significantly enhance the development and validation of microgrid algorithms, leading to more reliable and efficient microgrid operation.

at-scale↗

Numerical Analysis of High-Order Modes in SRF Resonators for Particle Accelerators

Over the past decades, superconducting technology has rapidly evolved towards high accelerating gradients and low surface resistance, making it possible to operate particle accelerators with high average beam currents and large duty factors. However, RF losses due to coherent excitation of the HOM become the limiting factor for these regimes. Unlike the cavity operating mode, which is tuned separately, the HOM parameters can significantly vary from one cavity to another due to finite mechanical tolerances during the manufacturing process. Thus, it is of utmost importance to know the HOM parameter spread in advance in order to predict unexpected cryogenic losses, overheating of beam line components and maintain stable beam dynamics. In this paper, we present a method for generating cavity geometry with an arbitrary spread of mechanical imperfections and numerically evaluating HOM statistics. Knowing the spread of HOM parameters, we calculated the probability of resonant HOM losses in SRF accelerating cavities used in CW beam current machines such as the PIP-II and LCLS-II linacs, as well as for the SRF crab-cavity for the ILC project. Finally, we present experimental results of HOM spectra measurements in hundreds of 1.3 GHz cavities installed in LCLS-II cryomodules. Studying the effects of HOM excitation results in specifications of the SRF cavity and cryomodule and can significantly impact the efficiency and reliability of the machine operation.

Lunin, Andrei [Fermilab] (ORCID:0000000290096792)↗

Transient Stability Study of a Real-World Microgrid with 100% Renewables

This paper performs a transient stability study of a real-world microgrid that can operate with 100% renewables to better understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, an electromagnetic transient model of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid. It can also inform field deployment in terms of inverter control parameters and coordination as well as the expected performance of black start and unplanned islanding.

black start↗

Transient Stability Study of a Real-World Microgrid with 100% Renewables

This paper performs a transient stability study of a real-world microgrid that can operate with 100% renewables to better understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, an electromagnetic transient model of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid. It can also inform field deployment in terms of inverter control parameters and coordination as well as the expected performance of black start and unplanned islanding.

black start↗

Light ion source for proton/deuteron production at CEA Saclay for the Spiral2 project

The production of rare radioactive ion beam (RIB) far from the valley of stability is one of the final purposes of the Spiral2 facility in Caen. The RIB will be produced by impinging a deuteron beam onto a carbon sample to produce a high neutron flux, which will interact with a uranium target. The primary deuteron beam is produced by an ion source based on ECR plasma generation. The deuteron source and the low energy beam transport (LEBT) has been assembled and tested at CEA Saclay. Diagnostics from other laboratories were implemented on the LEBT in order to characterize the deuteron beam produced and compare it to the initial simulations. The ion source has been based on a SILHI-type source, which has demonstrated good performances in pulsed and continuous mode, and also a very good reliability on long term operation. The 5 mA of deuteron beam required at the RFQ entrance is extracted from the plasma source at the energy of 40 kV. After a brief description of the experimental set-up, this article reports on the first beam characterization experiments.

43 PARTICLE ACCELERATORS↗