Search NASA⌕ Search

SEARCH · Search NASA

Results for “STORAGE DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Improving the Quality of Geothermal Data Through Data Standards and Pipelines Within the Geothermal Data Repository: Preprint

For machine learning outputs to be applicable to real world problems, high quality data are needed to ensure high quality results. With the more recent emphasis on machine learning in geothermal, there is an increasing need for greater focus on the quality of the data available for use in these projects. For example, Geothermal Operational Optimization Using Machine Learning (GOOML) utilized large quantities of geothermal power plant operational data to inform power plant operational configurations to maximize power generation. High quality datasets result from dependable sensors or devices collecting data, high frequency of measurements, sufficient data points, adequate metadata, reliable storage of data, and sufficient data curation. Another component that contributes to high quality data is reusability, which can be enhanced through data standardization. Data Standardization creates consistency in formatting and contents of like datasets, lessening preprocessing requirements and ensuring adequate information provided by a given dataset. The Geothermal Data Repository (GDR) aims to help improve data quality through automated data standardization for high-value datasets through the implementation of data pipelines alongside reliable and accessible long-term storage for datasets. As such, the GDR has decided to shift away from recommending the use of Excel-based content models and towards the implementation of automated data pipelines. This takes the burden of data standardization off the user and project team and will increase the availability of standardized geothermal data available through the GDR. A set of recommendations, or a data standard for each data type will exist with each data pipeline in order to advise data collection for maximum usability for future research. This paper serves to describe the GDR's proposed transition towards data standardization through automated data pipelines, to discuss the need for and value of such a shift, and to call for suggestions from the community regarding the most useful data standards and pipelines.

data↗

Decontamination and Decommissioning Program of a Radiopharmaceuticals Production Facility - 17103

On May 2012, Best Medical Belgium (BMB) S.A., a manufacturer of pharmaceutical products located on the nuclear site of Fleurus, was declared bankrupt. According to the Belgian law, ONDRAF/NIRAS (Belgian Radioactive Waste Management Agency) was entrusted with the clean-up and the decommissioning operations of the former BMB facilities, nowadays known as 'ONDRAF/NIRAS Site Fleurus' (ONSF). In June 2015, ONSF launched a Decontamination and Decommissioning (D and D) program, for which Tractebel supports the definition of the clean-up and decommissioning strategies; the drafting of the Final Decommissioning Plan (FDP) and License Application for decommissioning; and the follow-up of the clean-up and upcoming D and D works on site. Four nuclear buildings are part of the clean-up and D and D activities. One of them, Building 14 (B14), represents the most challenging task with the clean-up of highly contaminated areas and their further decommissioning up to greenfield. Beside its two cyclotrons successively used for the production of radioisotopes, this building features hot cells and glove boxes used for the purification of radioisotopes and the conditioning of the final pharmaceutical product. The present paper aims at presenting the development of the D and D program in terms of modifications of existing facilities to allow carrying out the clean-up and D and D activities and the management of dismantled radioactive materials in a safe, efficient and cost-effective way as well as in terms of strategic options to be developed for the FDP. To support the clean-up and D and D activities, several workshops have been designed in order to treat radioactive materials removed from the building rooms. Those workshops feature an input buffer storage area, a common output buffer storage area and installations for the treatment of radioactive materials and waste (handling devices, cutting means, decontamination means, free release measurements means, etc.). Some modifications to the existing auxiliary systems will be required in order to dispose of appropriate systems to operate those workshops in a safe way. Activated concrete structures will constitute the most important part of radioactive materials that will arise from the decommissioning activities. To limit the total decommissioning costs, and especially the costs associated to radioactive waste management, two strategies have been developed in order to manage a part of activated concrete as candidate for free release with a certain decay period or as candidate for conventional landfill. Both strategies will have to be further detailed and discussed with the competent Authorities to ensure they can actually be implemented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methane Emissions Produced by Pneumatic Devices and Produced Water Tanks on Natural Gas Wellsites

In recent years, more scrutiny has been placed on the release of greenhouse gasses (GHGs) by the oil and gas industry in North America as climate concerns increase. In the coming years, stricter regulations proposed by the Environmental Protection Agency (EPA) concerning the release of GHGs will further direct attention to GHG emissions quantification, modeling, and overall reduction. Active natural gas wellsites employ production equipment that routinely emits methane during normal operation. Production equipment often includes, but is not limited to, gas production units (GPUs), pneumatic controllers (PCs) and actuators powered by produced natural gas, and produced water storage tanks. This work details direct methane emission measurements taken at active natural gas wellsites originating from intermittent pneumatic controllers and produced water storage tanks. Efforts to model methane flows originating from these sources are also detailed, and those results are compared to direct measurement. The direct methane emissions measurement campaign collected flow data from two active dry wellsites in the Marcellus shale region. These measurement campaigns captured, in total, several weeks of continuous data from these sites. Data included multiple pneumatic device vent flowrate channels, a single channel monitoring total emissions vented from the produced water storage tanks, and corresponding site weather data. Periodic composition measurements were taken from flows vented from produced water tanks. Computational modeling efforts attempted to mimic a given site’s methane emissions behavior given limited input parameters. Direct measurement data and simulation data yielded, through reduction and analysis, apparent methane emissions factors, statistics on pneumatic device actuation events, important relationships between GPU parameters and pneumatic device actuation events, produced water storage tank vent flows and flow compositions, and parameters most contributing to the magnitude and frequency of these fugitive methane emissions. Measurements, considering data from a 72hr period, produced PC emissions factors from 0.008 to 0.03 SCFH per device with an average device emitting 0.026 SCFH at the first site. The second site produced PC emissions factors spanning from 0.05 to 25.47 SCFH with an average device emitting 1.93 SCFH not including the 25.47 SCFH device, which was assumed to be malfunctioning. Two unique water tank emission measurements were made, 618 g CH4 per hour and 32.6 g CH4 per hour. On a water basis, the water tank emissions factors were 0.66 and 0.042 kg CH4 per bbl of water, respectively.

03 NATURAL GAS↗

Antiphase-Boundary-Engineered Domain Switching in a (110)-Oriented BiFeO 3 Film

A ferroelectric domain wall memory device exploits the presence (or absence) of domain walls as the basis for information storage. Although structural defects strongly influence ferroelectric domain wall nucleation and growth, this correlation is far from being fully understood. For example, a single defect can play opposing roles: it can act as a nucleation site to initiate domain switching or, conversely, serve as a pinning center inhibiting domain wall motion. This is particularly the case for antiphase boundaries (APBs), whose influence on switching remains relatively unexplored despite being ubiquitous in oxide perovskite ferroelectrics. Here, we use aberration-corrected scanning transmission microscopy and in situ transmission electron microscopy under an applied bias to extensively characterize the influence of an APB on the switching behavior in a (110)-oriented BiFeO 3 thin film. We demonstrate that deterministic nucleation occurs in the proximity of a vertically oriented APB, following which domain growth occurs laterally in a symmetric fashion. Atomic-scale structural analysis reveals that the shear operation vector for the APB is 1/2[110]; this half-unit-cell shift extends over a few nanometers, implying that the APB plane is inclined toward the imaging direction. The symmetric switching observation is attributed to local inhomogeneous lattice strain and a reduction of polarization caused by the APB. These results demonstrate that an extended structural defect can be used as an active switching element rather than a stumbling block in reprogrammable domain-wall-based devices. Ultimately, this will expand the capabilities of ferroelectric thin films for future electronic devices based on ferroelectric domain walls.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quasi-unipolar pentacene films embedded with fullerene for non-volatile organic transistor memories

Quasi-unipolar non-volatile organic transistor memory (NOTM) can combine the best characteristics of conventional unipolar and ambipolar NOTMs and, as a result, exhibit improved device performance. Unipolar NOTMs typically exhibit a large signal ratio between the programmed and erased current signals but also require a large voltage to program and erase the memory cells. Meanwhile, an ambipolar NOTM can be programmed and erased at lower voltages, but the resulting signal ratio is small. By embedding a discontinuous n-type fullerene layer within a p-type pentacene film, quasi-unipolar NOTMs are fabricated, of which the signal storage utilizes both electrons and holes while the electrical signal relies on only hole conduction. These devices exhibit superior memory performance relative to both pristine unipolar pentacene devices and ambipolar fullerene/pentacene bilayer devices. The quasi-unipolar NOTM exhibited a larger signal ratio between the programmed and erased states while also reducing the voltage required to program and erase a memory cell. This simple approach should be readily applicable for various combinations of advanced organic semiconductors that have been recently developed and thereby should make a significant impact on organic memory research.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Digital Assurance Checklist for Homeowners and Installers

This document provides a comprehensive Digital Assurance Checklist for securing behind-the-meter energy assets, focusing on both installers and homeowners. As distributed energy resources (DERs) such as solar PV and battery storage become integral to residential energy systems, cybersecurity emerges as a critical component of reliability and safety. The guide outlines actionable steps for installers during pre-installation, commissioning, and post-installation phases, emphasizing practices like network segmentation, credential management, firmware validation, and homeowner education. For homeowners, the document introduces a tiered approach to cyber hygiene—from essential measures like strong Wi-Fi credentials and automatic updates to advanced strategies such as network segmentation, DNS filtering, and intrusion detection. By adopting these practices, stakeholders can mitigate cyber risks, safeguard energy infrastructure, and ensure resilient, secure operation of DER systems. Additional resources and references to industry standards are included to support implementation.

99 - GENERAL AND MISCELLANEOUS↗

Digital Assurance Checklist for Homeowners and Installers

This document provides a comprehensive Digital Assurance Checklist for securing behind-the-meter energy assets, focusing on both installers and homeowners. As distributed energy resources (DERs) such as solar PV and battery storage become integral to residential energy systems, cybersecurity emerges as a critical component of reliability and safety. The guide outlines actionable steps for installers during pre-installation, commissioning, and post-installation phases, emphasizing practices like network segmentation, credential management, firmware validation, and homeowner education. For homeowners, the document introduces a tiered approach to cyber hygiene—from essential measures like strong Wi-Fi credentials and automatic updates to advanced strategies such as network segmentation, DNS filtering, and intrusion detection. By adopting these practices, stakeholders can mitigate cyber risks, safeguard energy infrastructure, and ensure resilient, secure operation of DER systems. Additional resources and references to industry standards are included to support implementation.

99 - GENERAL AND MISCELLANEOUS↗

Perspective—Electrochemistry in Understanding and Designing Electrochemical Energy Storage Systems

The number of publications in electrochemical energy storage has increased exponentially in the past decades, focusing mostly on materials science. The electrochemical process controlling the observed overall performances is often not well discussed. This article highlights the importance of understanding rate-limiting steps in the electrochemical process which change dynamically at different conditions and scales. Applying electrochemistry to identify and overcome those rate-limiting steps in the electrochemical devices is the prerequisite to discovering effective solutions and designing different batteries to further advance electrochemical energy storage systems for a broad range of various applications.

25 ENERGY STORAGE↗

A combined theoretical-experimental study of interactions between vanadium ions and Nafion membrane in all-vanadium redox flow batteries

Vanadium redox flow batteries (VRFBs) are a promising solution for large-scale energy storage, but a number of problems still impede the deployment of long-lifetime VRFBs. One important aspect of efficient operation of VRFBs is understanding interactions between vanadium species and the membrane. Herein, we investigate the interactions between all four vanadium cations and Nafion membrane by a combination of infrared (IR) spectroscopy and density-functional-theory (DFT)-based static and molecular dynamics simulations. It is observed that vanadium species primarily lead to changes in the IR spectrum of Nafion in the SO 3 - spectral region which is attributed to the interaction between vanadium species and the SO 3 - exchange sites. DFT calculations of vanadium - Nafion complexes in the gas phase show that it is thermodynamically favorable for all vanadium cations to bind to SO 3 - via a contact pair mechanism. Car-Parrinello molecular dynamics-based metadynamics simulations of cation-Nafion systems in aqueous solution suggest that and species coordinate spontaneously to SO 3 - , which is not the case for VO 2+ and VO 2 + . The interaction behavior of the uncycled membrane determined in this study is used to explain the experimentally observed changes in the vibrational spectra, and is discussed in light of previous results on device-cycled membranes.

00-01↗

Redox shuttles for lithium ion batteries

Compounds may have general Formula IVA or IVB. ##STR00001## where, R.sup.8, R.sup.9, R.sup.10, and R.sup.11 are each independently selected from H, F, Cl, Br, CN, NO.sub.2, alkyl, haloalkyl, and alkoxy groups; X and Y are each independently O, S, N, or P; and Z' is a linkage between X and Y. Such compounds may be used as redox shuttles in electrolytes for use in electrochemical cells, batteries and electronic devices.

25 ENERGY STORAGE↗

Non-aqueous electrolytes for electrochemical cells

An electrolyte electrochemical device includes an anodic material and an electrolyte, the electrolyte including an organosilicon solvent, a salt, and a hybrid additiving having a first and a second compound, the hybrid additive configured to form a solid electrolyte interphase film on the anodic material upon application of a potential to the electrochemical device.

25 ENERGY STORAGE↗

Partial defect verification of spent fuel assemblies by PDET: Principle and field testing in Interim Spent fuel Storage Facility (CLAB) in Sweden

Here, the need for the development of a credible method and instrument for partial defect verification of spent fuel has been emphasized over a few decades in the safeguards communities as the diverted spent fuel pins can be the source of nuclear terrorism or devices. The need is increasingly more important and even urgent as many countries have started to transfer spent fuel to so called "difficult-to-access" areas such as dry storage casks, reprocessing or geological repositories. Partial defect verification is required by IAEA before spent fuel is placed into "difficult-to-access" areas. Earlier, Lawrence Livermore National Laboratory (LLNL) has reported the successful development of a new, credible partial defect verification method for pressurized water reactor (PWR) spent fuel assemblies without use of operator data, and further reported the validation experiments using commercial spent fuel assemblies with some missing fuel pins. The method was found to be robust as the method is relatively invariant to the characteristic variations of spent fuel assemblies such as initial fuel enrichment, cooling time, and burn-up. Since then, the PDET system has been designed and prototyped for 17×17 PWR spent fuel assemblies, complete with data acquisition software and acquisition electronics. In this paper, a summary description of the PDET development followed by results of the first successful field testing using the integrated PDET system and actual spent fuel assemblies performed in a commercial spent fuel storage site, known as Central Interim Spent fuel Storage Facility (CLAB) in Sweden will be presented. In addition to partial defect detection initial studies have determined that the tool can be used to verify the operator declared average burnup of the assembly as well as intra-assembly bunrup levels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gamma Imaging Improvements for GrayQb™

SRNL’s Imaging, Robotics, and Radiation Systems Group has had several successful field deployments with the GrayQb™, a custom designed radiation mapping device. The GrayQb™ returned consistent radiation contour maps through its deployment and demonstrated its effectiveness in quickly and inexpensively capturing images of radiation hot spots. To process the images from the GrayQb™, the device must be recovered between each deployment. This is due to the GrayQb™’s use of Phosphor Storage Plates (PSPs), which are a standard X-ray imaging material in dentistry and oral applications. PSPs are highly sensitive to radiation; however, currently they must be processed through an external scanner. SRNL designed the GrayQb™ for radiation areas, and much effort is required to deploy and recover the GrayQb™. To reduce time and resources spent deploying and recovering the GrayQb™, SRNL is working to upgrade the device to read PSP images and transmit image data to an external location using an internal camera system eliminating the need to remove the PSP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Programmable delay device enabling large delay in small package

A programmable delay device that provides delays of more than 100 ns over a broad bandwidth is disclosed. The device includes an input stage that employs M sampling switched capacitor elements such that each sampling switched capacitor element samples at a rate of only 1/M of the fundamental sampling rate. The device includes a programmable delay stage with M programmable switched capacitor banks, each programmable switched capacitor bank having N delay switched capacitor storage elements. Thus, the programmable delay stage includes a total of M×N delay switched capacitor storage elements, thereby reducing the sampling rate by a factor of M×N. This reduced sampling rate permits much smaller sampling switches, resulting in reduced leakage current and enabling far longer programmable delay times. Lastly, the device includes an output reconstruction stage that reconstructs a delayed version of the input RF signal by combining signals from the programmable delay stage.

Forbes, Travis↗

Refurbishment of radiation-damaged undulators

Partial radiation damage has been observed over the previous five years of operation for a few of the PETRA III permanent magnet undulators at DESY. The degradation of the affected devices has been observed by a change in the energy tuning curves and the spectral properties of the undulator harmonics, and also by direct measurements of the peak field distribution of the magnet structure in the storage ring tunnel [1]. During the recent shutdown of the machine, two undulators were removed from the tunnel for repair. One of the devices (U29) has been retuned after flipping of all magnets of the hybrid structure. In addition to this temporary repair, one further magnet structure (U23) has been completely disassembled and refurbished by application of a rare earth diffusion process and a coating to the permanent magnets. We will report on the details of the refurbishment of these undulators which were both fully brought back to specifications and are meanwhile back in operation.

43 PARTICLE ACCELERATORS↗

Thermophotovoltaic efficiency of 40%

Thermophotovoltaics (TPVs) convert predominantly infrared wavelength light to electricity via the photovoltaic effect, and can enable approaches to energy storage and conversion that use higher temperature heat sources than the turbines that are ubiquitous in electricity production today. Since the first demonstration of 29% efficient TPVs (Fig. 1a) using an integrated back surface reflector and a tungsten emitter at 2,000°C (ref. 10), TPV fabrication and performance have improved. However, despite predictions that TPV efficiencies can exceed 50%, the demonstrated efficiencies are still only as high as 32%, albeit at much lower temperatures below 1,300 C (refs. 13,14,15). Here we report the fabrication and measurement of TPV cells with efficiencies of more than 40% and experimentally demonstrate the efficiency of high-bandgap tandem TPV cells. The TPV cells are two-junction devices comprising III–V materials with bandgaps between 1.0 and 1.4 eV that are optimized for emitter temperatures of 1,900–2,400°C. The cells exploit the concept of band-edge spectral filtering to obtain high efficiency, using highly reflective back surface reflectors to reject unusable sub-bandgap radiation back to the emitter. A 1.4/1.2 eV device reached a maximum efficiency of (41.1 ± 1)% operating at a power density of 2.39 W cm –2 and an emitter temperature of 2,400°C. A 1.2/1.0 eV device reached a maximum efficiency of (39.3 ± 1)% operating at a power density of 1.8 W cm–2 and an emitter temperature of 2,127°C. These cells can be integrated into a TPV system for thermal energy grid storage to enable dispatchable renewable energy. This creates a pathway for thermal energy grid storage to reach sufficiently high efficiency and sufficiently low cost to enable decarbonization of the electricity grid.

14 SOLAR ENERGY↗

Field-Deployable Quantum Memory for Quantum Networking

High-performance quantum memories are an essential component for regulating temporal events in quantum networks. As a component in quantum-repeaters, they have the potential to support the distribution of entanglement beyond the physical limitations of fiber loss. This will enable key applications such as quantum key distribution, network-enhanced quantum sensing, and distributed quantum computing. Here, we present a quantum memory engineered to meet real-world deployment and scaling challenges. The memory technology utilizes a warm rubidium vapor as the storage medium, and operates at room temperature, without the need for vacuum- and/or cryogenic- support. Here, we demonstrate performance specifications of high-fidelity retrieval (95%) and low operation error (10 –2 ) at a storage time of 160 µs for single-photon level quantum memory operations. We further show a substantially improved storage time (with classical-level light) of up to 1ms by suppressing atomic diffusions. The device is housed in an enclosure with a standard 2U rackmount form factor, and can robustly operate on a day scale in a noisy environment. This result marks an important step toward implementing quantum networks in the field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and Experimental Validation of a High-Power DC Distribution Testbed for Advanced Charging Infrastructure and Energy Management

This paper presents the development of a hardware testbed for DC-distributed high-power charging (HPC) stations. As DC distributed solutions emerge as a viable solution to optimize HPC site operations, challenges such as interoperability, protection, and seamless integration of distributed energy resources (DER) persist. These issues underscore the need for a robust testing facility to investigate compliance of available commercial off-the-shelf (COTS) market devices. The developed testbed features a DC-distributed charging hub including a charger, emulated energy storage system (ESS), and site level communication and controller implementation. It facilitates the testing of COTS hardware, charger prototypes, standards validation and site energy management system (SEMS) controllers at rated power. This paper details the development of the charging infrastructure platform, implementation of communication system, validation of different SEMS algorithms, and understanding improvements required for future expansion. Using the developed testbed, interoperability gaps for SEMS implementation with multi-vehicle concurrent charging via a multi-port charger are experimentally observed. Aimed at supporting the transition to large-scale EV charging infrastructure deployment and DER integration, this testbed plays a crucial role in conformity testing of COTS device interoperability.

24 POWER TRANSMISSION AND DISTRIBUTION↗