Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spatial process”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Noise properties of grating-based x-ray phase contrast computed tomography

Purpose: To investigate the properties of tomographic grating-based phase contrast imaging with respect to its noise power spectrum and the energy dependence of the achievable contrast to noise ratio. Methods: Tomographic simulations of an object with 11 cm diameter constituted of materials of biological interest were conducted at different energies ranging from 25 to 85 keV by using a wave propagation approach. Using a Monte Carlo simulation of the x-ray attenuation within the object, it is verified that the simulated measurement deposits the same dose within the object at each energy. Results: The noise in reconstructed phase contrast computed tomography images shows a maximum at low spatial frequencies. The contrast to noise ratio reaches a maximum around 45 keV for the simulated object. The general dependence of the contrast to noise on the energy appears to be independent of the material. Compared with reconstructed absorption contrast images, the reconstructed phase contrast images show sometimes better, sometimes worse, and sometimes similar contrast to noise, depending on the material and the energy. Conclusions: Phase contrast images provide additional information to the conventional absorption contrast images and might thus be useful for medical applications. However, the observed noise power spectrum in reconstructed phase contrast images implies that the usual trade-off between noise and resolution is less efficient for phase contrast imaging compared with absorption contrast imaging. Therefore, high-resolution imaging is a strength of phase contrast imaging, but low-resolution imaging is not. This might hamper the clinical application of the method, in cases where a low spatial resolution is sufficient for diagnosis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Smart Adhesive Joint with High-Definition Fiber-Optic Sensing for Automotive Applications

Structural health monitoring of fiber-reinforced composite-based joints for automotive applications during their manufacturing and on-demand assessment for its durability in working environments is critically needed. High-definition fiber-optic sensing is an effective method to measure internal strain/stress development using minimally invasive continuous sensors. The sensing fiber diameters are in the same order of magnitude when compared to reinforcement (glass, basalt, or carbon fibers) used in polymer composites. They also offer a unique ability to monitor the evolution of residual stresses after repeated thermal exposure with varying temperatures for automotive components/joints during painting using an electrophoretic painting process. In this paper, a high-definition fiber-optic sensor utilizing Rayleigh scattering is embedded within an adhesive joint between a carbon fiber-reinforced thermoset composite panel and an aluminum panel to measure spatially resolved strain development, residual strain, and thermal expansion properties during the electrophoretic paint process-simulated conditions. The strain measured by the continuous fiber-optic sensor was compared with an alternate technique using thermal digital image correlation. The fiber-optic sensor was able to identify the spatial variation of residual strains for a discontinuous carbon fiber-reinforced composite with varying local fiber orientations and resin content.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polychromatic X-ray Micro- and Nanodiffraction for Spatially-Resolved Structural Studies

The availability of intense, focused synchrotron X-ray microbeams has enabled new techniques for materials investigations with sub-micron spatial resolution. The scanning microbeam setup we have developed at the XOR-UNI beamline at the Advanced Photon Source (APS) is versatile in that it provides 1D, 2D or 3D scans (including depth resolution), and can alternate between polychromatic- and monochromatic-beam modes. Focusing in both modes uses elliptical Kirkpatrick-Baez (K-B) reflecting mirrors. Beam diameters of {approx} 500 nm FWHM are now routine, and 90 nm focus has been demonstrated. In white-beam mode, a CCD detector records a complete Laue diffraction pattern, which is analyzed with an automated indexing program. These X-ray diffraction patterns provide real-space maps of the local lattice structure, crystal orientation, grain morphology, and strain tensor. Spatially-resolved X-ray microdiffraction studies are now providing previously unavailable measurements of local microstructures. These measurements, in turn, yield new insights in several classic fields of materials science. This paper will illustrate the application of polychromatic scanning X-ray microscopy with examples from 1D, 2D and 3D materials systems. In 1D systems, we have mapped the structure and orientation of an individual ZnO nanorod along with the associated Ge catalyst particle used to control the nanocrystal growth. In 2D systems, X-ray microdiffraction studies have revealed the mechanisms for local crystallographic tilting in epitaxial oxide films grown on textured Ni substrates for superconducting applications. In 3D systems, X-ray microscopy investigations have included in-situ studies of microstructural evolution during thermal grain growth in polycrystalline aluminum. In general, these spatially-resolved measurements provide important new insights and are valuable as input for theoretical and computer modeling studies of a wide range of material processes.

43 PARTICLE ACCELERATORS↗

Processes Associated with Boundary Layer Cloud Ice Phase Precipitation in the High Southern Latitudes (Final Technical Report)

This is a final technical report for DOE Award No. DE-SC0018995. Using data collected during the MARCUS deployment of the 2nd ARM mobile facility, this project sought to address the following scientific questions: 1. What are the conditions that govern phase partitioning in supercooled boundary layer clouds over the high latitude Southern Oceans? 2. To what extent are supercooled mixed phase clouds responsible for the high cloud fractions over the Southern Ocean and do these mixed phase clouds contribute to the model biases in absorbed shortwave radiation? 3. Can the cloud properties and phase partitioning over the Southern Ocean be linked to the underlying aerosol environment? 4. How do the aerosol properties at the surface vary spatially and seasonally over the high latitude Southern Ocean and what processes control these features? 5. How well defined are the atmospheric compositional boundaries between Southern Ocean marine, Antarctic free tropospheric, and Antarctic surface airmasses, and how does this influence the chemistry and physics of the Southern Ocean atmosphere? In this project we published three peer review journal articles that address these questions.

54 ENVIRONMENTAL SCIENCES↗

Geometric validation of self-gating k-space-sorted 4D-MRI vs 4D-CT using a respiratory motion phantom

Purpose: MRI is increasingly being used for radiotherapy planning, simulation, and in-treatment-room motion monitoring. To provide more detailed temporal and spatial MR data for these tasks, we have recently developed a novel self-gated (SG) MRI technique with advantage of k-space phase sorting, high isotropic spatial resolution, and high temporal resolution. The current work describes the validation of this 4D-MRI technique using a MRI- and CT-compatible respiratory motion phantom and comparison to 4D-CT. Methods: The 4D-MRI sequence is based on a spoiled gradient echo-based 3D projection reconstruction sequence with self-gating for 4D-MRI at 3 T. Respiratory phase is resolved by using SG k-space lines as the motion surrogate. 4D-MRI images are reconstructed into ten temporal bins with spatial resolution 1.56 × 1.56 × 1.56 mm{sup 3}. A MRI-CT compatible phantom was designed to validate the performance of the 4D-MRI sequence and 4D-CT imaging. A spherical target (diameter 23 mm, volume 6.37 ml) filled with high-concentration gadolinium (Gd) gel is embedded into a plastic box (35 × 40 × 63 mm{sup 3}) and stabilized with low-concentration Gd gel. The phantom, driven by an air pump, is able to produce human-type breathing patterns between 4 and 30 respiratory cycles/min. 4D-CT of the phantom has been acquired in cine mode, and reconstructed into ten phases with slice thickness 1.25 mm. The 4D images sets were imported into a treatment planning software for target contouring. The geometrical accuracy of the 4D MRI and CT images has been quantified using target volume, flattening, and eccentricity. The target motion was measured by tracking the centroids of the spheres in each individual phase. Motion ground-truth was obtained from input signals and real-time video recordings. Results: The dynamic phantom has been operated in four respiratory rate (RR) settings, 6, 10, 15, and 20/min, and was scanned with 4D-MRI and 4D-CT. 4D-CT images have target-stretching, partial-missing, and other motion artifacts in various phases, whereas the 4D-MRI images are visually free of those artifacts. Volume percentage difference for the 6.37 ml target ranged from 5.3% ± 4.3% to 10.3% ± 5.9% for 4D-CT, and 1.47 ± 0.52 to 2.12 ± 1.60 for 4D-MRI. With an increase of respiratory rate, the target volumetric and geometric deviations increase for 4D-CT images while remaining stable for the 4D-MRI images. Target motion amplitude errors at different RRs were measured with a range of 0.66–1.25 mm for 4D-CT and 0.2–0.42 mm for 4D-MRI. The results of Mann–Whitney tests indicated that 4D-MRI significantly outperforms 4D-CT in phase-based target volumetric (p = 0.027) and geometric (p < 0.001) measures. Both modalities achieve equivalent accuracy in measuring motion amplitude (p = 0.828). Conclusions: The k-space self-gated 4D-MRI technique provides a robust method for accurately imaging phase-based target motion and geometry. Compared to 4D-CT, the current 4D-MRI technique demonstrates superior spatiotemporal resolution, and robust resistance to motion artifacts caused by fast target motion and irregular breathing patterns. The technique can be used extensively in abdominal targeting, motion gating, and toward implementing MRI-based adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

Advanced Instrumentation for Metal Additive Manufacturing

Laser powder bed fusion (LPBF) is the most widely used process for metal additive manufacturing (AM), particularly where complex geometries provide performance advantages unattainable with traditional manufacturing techniques. However, LPBF is highly sensitive to innate variability in both the powder spreading and fusion steps, often leading to defects such as pores that are difficult to detect yet significantly impair component mechanical properties and fatigue life. This thesis presents a range of novel instruments enabling both precise assessment of powder layer characteristics and in-situ thermal metrology of metal AM to advance the quality control of LPBF. First, leveraging a custom X-ray microscope and a radiation-transport model developed through this work, transmission X-ray imaging is used to study spreading of thin metal powder layers. Effective layer depth is directly mapped at a process-relevant size scale, surpassing optical techniques that can only estimate local deposition from layer surface topography. Layer packing density and quality are shown to be influenced by powder flowability and particle size relative to nominal powder layer thickness. Layer quality is additionally connected to the geometry of the spreading implement and its velocity. This technique and its presented findings enable pairing feedstocks with spreading strategies that create layers with consistent packing density and uniformity. Second, a twofold approach is employed to optically interrogate the laser fusion step of LPBF for observing signatures of defect formation. Aperture division multiplexing is conceptualized, providing for simultaneous laser delivery and high-fidelity infrared (IR) process monitoring through a common optic. In-situ microscopy at 50 μm spatial resolution and at mid-wave IR wavelengths is proven readily achievable with the first purpose-built optic of this type. Next, a bespoke imaging spectrometer, along with a temperature-emissivity separation technique, is used to retrieve accurate process temperatures over a 1000 K range. Data from these instruments are correlated to porosity as fine as 4.3 μm in two LPBF test artifacts, as verified using computed tomography (CT), establishing the viability of robust optically-based component qualification.

Penny, Ryan↗

Delineating Facies Spatial Distribution by Integrating Ensemble Data Assimilation and Indicator Geostatistics with Level Set Transformation.

A new approach is developed to delineate the spatial distribution of discrete facies (geological units that have unique distributions of hydraulic, physical, and/or chemical properties) conditioned not only on direct data (measurements directly related to facies properties, e.g., grain size distribution obtained from borehole samples) but also on indirect data (observations indirectly related to facies distribution, e.g., hydraulic head and tracer concentration). Our method integrates for the first time ensemble data assimilation with traditional transition probability-based geostatistics. The concept of level set is introduced to build shape parameterization that allows transformation between discrete facies indicators and continuous random variables. The spatial structure of different facies is simulated by indicator models using conditioning points selected adaptively during the iterative process of data assimilation. To evaluate the new method, a two-dimensional semi-synthetic example is designed to estimate the spatial distribution and permeability of two distinct facies from transient head data induced by pumping tests. The example demonstrates that our new method adequately captures the spatial pattern of facies distribution by imposing spatial continuity through conditioning points. The new method also reproduces the overall response in hydraulic head field with better accuracy compared to data assimilation with no constraints on spatial continuity on facies.

97 MATHEMATICS AND COMPUTING↗

2D Spatial Frequency Considerations in Comparing 1D Power Spectral Density Measurements

The frequency footprint of ID and 2D profiling instruments needs to be carefully considered in comparing ID surface roughness spectrum measurements made by different instruments. Contributions from orthogonal direction frequency components can not be neglected. The use of optical profiling instruments is ubiquitous in the measurement of the roughness of optical surfaces. Their ease-of-use and non-contact measurement method found widespread use in the optics industry for measuring the quality of delicate optical surfaces. Computerized digital data acquisition with these instruments allowed for quick and easy calculation of surface roughness statistics, such as root-mean-square (RMS) roughness. The computing power of the desktop computer allowed for the rapid conversion of spatial domain data into the frequency domain, enabling the application of sophisticated signal processing techniques to be applied to the analysis of surface roughness, the most powerful of which is the power spectral density (PSP) function. Application of the PSD function to surface statistics introduced the concept of 'bandwidth-limited' roughness, where the value of the RMS roughness depends critically upon the spatial frequency response of the instrument. Different instruments with different spatial frequency response characteristics give different answers when measuring the same surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study of internal structure in components made by additive manufacturing process using 3 D X-ray tomography

Additive manufacturing methods are gaining increasing popularity for rapidly and efficiently manufacturing parts and components in the industrial context, as well as for domestic applications. However, except when used for prototyping or rapid visualization of components, industries are concerned with the load carrying capacity and strength achievable by additive manufactured parts. In this paper, the wire-arc additive manufacturing (AM) process based on gas tungsten arc welding (GTAW) has been examined for the internal structure and constitution of components generated by the process. High-resolution 3D X-ray tomography is used to gain cut-views through wedge-shaped parts created using this GTAW additive manufacturing process with titanium alloy materials. In this work, two different control conditions for the GTAW process are considered. The studies reveal clusters of porosities, located in periodic spatial intervals along the sample cross-section. Such internal defects can have a detrimental effect on the strength of the resulting AM components, as shown in destructive testing studies. Closer examination of this phenomenon shows that defect clusters are preferentially located at GTAW traversal path intervals. These results highlight the strong need for enhanced control of process parameters in ensuring components with minimal defects and higher strength.

36 MATERIALS SCIENCE↗

Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction

Purpose: The ionizing radiation imparted to patients during computed tomography exams is raising concerns. This paper studies the performance of a scheme called dose reduction using prior image constrained compressed sensing (DR-PICCS). The purpose of this study is to characterize the effects of a statistical model of x-ray detection in the DR-PICCS framework and its impact on spatial resolution. Methods: Both numerical simulations with known ground truth and in vivo animal dataset were used in this study. In numerical simulations, a phantom was simulated with Poisson noise and with varying levels of eccentricity. Both the conventional filtered backprojection (FBP) and the PICCS algorithms were used to reconstruct images. In PICCS reconstructions, the prior image was generated using two different denoising methods: a simple Gaussian blur and a more advanced diffusion filter. Due to the lack of shift-invariance in nonlinear image reconstruction such as the one studied in this paper, the concept of local spatial resolution was used to study the sharpness of a reconstructed image. Specifically, a directional metric of image sharpness, the so-called pseudopoint spread function (pseudo-PSF), was employed to investigate local spatial resolution. Results: In the numerical studies, the pseudo-PSF was reduced from twice the voxel width in the prior image down to less than 1.1 times the voxel width in DR-PICCS reconstructions when the statistical model was not included. At the same noise level, when statistical weighting was used, the pseudo-PSF width in DR-PICCS reconstructed images varied between 1.5 and 0.75 times the voxel width depending on the direction along which it was measured. However, this anisotropy was largely eliminated when the prior image was generated using diffusion filtering; the pseudo-PSF width was reduced to below one voxel width in that case. In the in vivo study, a fourfold improvement in CNR was achieved while qualitatively maintaining sharpness; images also had a qualitatively more uniform noise spatial distribution when including a statistical model. Conclusions: DR-PICCS enables to reconstruct CT images with lower noise than FBP and the loss of spatial resolution can be mitigated to a large extent. The introduction of statistical modeling in DR-PICCS may improve some noise characteristics, but it also leads to anisotropic spatial resolution properties. A denoising method, such as the directional diffusion filtering, has been demonstrated to reduce anisotropy in spatial resolution effectively when it was combined with DR-PICCS with statistical modeling.

60 APPLIED LIFE SCIENCES↗

Patient-specific quantification of image quality: An automated method for measuring spatial resolution in clinical CT images

Purpose: To develop and validate an automated technique for evaluating the spatial resolution characteristics of clinical computed tomography (CT) images. Methods: Twenty one chest and abdominopelvic clinical CT datasets were examined in this study. An algorithm was developed to extract a CT resolution index (RI) analogous to the modulation transfer function from clinical CT images by measuring the edge-spread function (ESF) across the patient’s skin. A polygon mesh of the air-skin boundary was created. The faces of the mesh were then used to measure the ESF across the air-skin interface. The ESF was differentiated to obtain the line-spread function (LSF), and the LSF was Fourier transformed to obtain the RI. The algorithm’s ability to detect the radial dependence of the RI was investigated. RIs measured with the proposed method were compared with a conventional phantom-based method across two reconstruction algorithms (FBP and iterative) using the spatial frequency at 50% RI, f{sub 50}, as the metric for comparison. Three reconstruction kernels were investigated for each reconstruction algorithm. Finally, an observer study was conducted to determine if observers could visually perceive the differences in the measured blurriness of images reconstructed with a given reconstruction method. Results: RI measurements performed with the proposed technique exhibited the expected dependencies on the image reconstruction. The measured f{sub 50} values increased with harder kernels for both FBP and iterative reconstruction. Furthermore, the proposed algorithm was able to detect the radial dependence of the RI. Patient-specific measurements of the RI were comparable to the phantom-based technique, but the patient data exhibited a large spread in the measured f{sub 50}, indicating that some datasets were blurrier than others even when the projection data were reconstructed with the same reconstruction algorithm and kernel. Results from the observer study substantiated this finding. Conclusions: Clinically informed, patient-specific spatial resolution can be measured from clinical datasets. The method is sufficiently sensitive to reflect changes in spatial resolution due to different reconstruction parameters. The method can be applied to automatically assess the spatial resolution of patient images and quantify dependencies that may not be captured in phantom data.

60 APPLIED LIFE SCIENCES↗

Community structure – Ecosystem function relationships in the Congo Basin methane cycle depend on the physiological scale of function

Belowground ecosystem processes can be highly variable and difficult to predict using microbial community data. Here, we argue that this stems from at least three issues: (a) complex covariance structure of samples (with environmental conditions or spatial proximity) can make distinguishing biotic drivers a challenge; (b) communities can control ecosystem processes through multiple mechanisms, making the identification of these controls a challenge; and (c) ecosystem function assessments can be broad in physiological scale, encapsulating multiple processes with unique microbially mediated controls. In this work, we test these assertions using methane (CH 4 )-cycling processes in soil samples collected along a wetland-to-upland habitat gradient in the Congo Basin. We perform our measurements of function under controlled laboratory conditions and statistically control for environmental covariates to aid in identifying biotic drivers. We divide measurements of microbial communities into four attributes (abundance, activity, composition, and diversity) that represent different forms of community control. Lastly, our process measurements differ in physiological scale, including broader processes (gross methanogenesis and methanotrophy) that involve more mediating groups, to finer processes (hydrogenotrophic methanogenesis and high-affinity CH 4 oxidation) with fewer mediating groups. We observed that finer scale processes can be more readily predicted from microbial community structure than broader scale processes. In addition, the nature of those relationships differed, with broad processes limited by abundance while fine-scale processes were associated with diversity and composition. These findings demonstrate the importance of carefully defining the physiological scale of ecosystem function and performing community measurements that represent the range of possible controls on ecosystem processes.

54 ENVIRONMENTAL SCIENCES↗

Spatial-Temporal PV Hosting Capacity Estimation and Evaluation

Evaluating Photovoltaic Hosting Capacity (PVHC) is an essential step in the process of integrating solar energy into power grids, particularly when focusing on the distribution network (DN) as the primary integration target. PVHC needs to be investigated, especially in cases where the grids are unbalanced, and their operational conditions vary spatially and temporally. This motivation prompted us to propose a scalable model tailored to this application. In this paper, we applied linearization to the alternating current optimal power flow (AC-OPF) and solar inverters, transforming the original problem into a mixed-integer linear programming (MILP) problem. Additionally, we accounted for the battery energy storage system (BESS) as a time-coupling factor for calculating PVHC. We then compared the PVHC results between the IEEE-13 bus and SMART-DS San Francisco (SFO) cases and discussed the extent to which BESS can enhance the PVHC of a DN. Furthermore, we designed a web-based graphical visualization for the SFO case, enabling user interaction with raw data and simulation results on a map through a graphical user interface (GUI). In summary, our results and findings provide valuable insights for future three-phase unbalanced AC-OPF PVHC practices and their visualization.

AC-optimal power flow↗

Mesh generation and energy group condensation studies for the jaguar deterministic transport code

The deterministic transport code Jaguar is introduced, and the modeling process for Jaguar is demonstrated using a two-dimensional assembly model of the Hoogenboom-Martin Performance Benchmark Problem. This single assembly model is being used to test and analyze optimal modeling methodologies and techniques for Jaguar. This paper focuses on spatial mesh generation and energy condensation techniques. In this summary, the models and processes are defined as well as thermal flux solution comparisons with the Monte Carlo code MC21. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The strain-dependent spatial evolution of garnet in a high- P ductile shear zone from the Western Gneiss Region (Norway): a synchrotron X-ray microtomography study

Reaction and deformation microfabrics provide key information to understand the thermodynamic and kinetic controls of tectono-metamorphic processes, however they are usually analysed in two dimensions, omitting important information regarding the third spatial dimension. We applied synchrotron-based X-ray microtomography to document the evolution of a pristine olivine gabbro into a deformed omphacite-garnet eclogite in four dimensions, where the 4th dimension is represented by the degree of strain. In the investigated samples, which cover a strain gradient into a shear zone from the Western Gneiss Region (Norway), we focused on the spatial transformation of garnet coronas into elongated clusters of garnets with increasing strain. Our microtomographic data allowed quantification of garnet volume, shape and spatial arrangement evolution with increasing strain. We combined microtomographic observations with light microscope- and backscatter electron images as well as electron microprobe- (EMPA) and electron backscatter diffraction (EBSD) analysis to correlate mineral composition and orientation data with the X-ray absorption signal of the same mineral grains. With increasing deformation, the garnet volume almost triples. In the low strain domain, garnets form a well interconnected large garnet aggregate that develops throughout the entire Page 1 of 52 sample. We also observed that garnet coronas in the gabbros never completely encapsulate olivine grains. In the most highly deformed eclogites, the oblate shapes of garnet clusters reflect a deformational origin of the microfabrics. We interpret the aligned garnet aggregates to direct synkinematic fluid flow and consequently influence the transport of dissolved chemical components. EBSD analyses reveal that garnet show a near-random crystal preferred orientation that testifies no evidence for crystal plasticity. There is, however evidence for minor fracturing, neo-nucleation and overgrowth. Microprobe chemical analysis revealed that garnet compositions progressively equilibrate to eclogite facies, becoming more almandine-rich. We interpret these observations as pointing to a mechanical disintegration of the garnet coronas during strain localisation, and their rearrangement into individual garnet clusters through a combination of garnet coalescence and overgrowth while the rock was deforming.

garnet↗

Organismal and spatial partitioning of energy and macronutrient transformations within a hypersaline mat

Phototrophic mat communities are model ecosystems for studying energy cycling and elemental transformations because complete biogeochemical cycles occur over millimeter-to-centimeter scales. Characterization of energy and nutrient capture within hypersaline phototrophic mats has focused on specific processes and organisms, however little is known about community-wide distribution of and linkages between these processes. To investigate energy and macronutrient capture and flow through a structured community, the spatial and organismal distribution of metabolic functions within a compact hypersaline mat community from Hot Lake have been broadly elucidated through species-resolved metagenomics and geochemical, microbial diversity, and metabolic gradient measurements. Draft reconstructed genomes of abundant organisms revealed three dominant cyanobacterial populations differentially distributed across the top layers of the mat suggesting niche separation along light and oxygen gradients. Many organisms contained diverse functional profiles, allowing for metabolic response to changing conditions within the mat. Organisms with partial nitrogen and sulfur metabolisms were widespread indicating dependence upon metabolite exchange. In addition, changes in community spatial structure were observed over the diel. These results indicate that organisms within the mat community have adapted to the temporally dynamic environmental gradients in this hypersaline mat through metabolic flexibility and fluid syntrophic interactions, including shifts in spatial arrangements.

59 BASIC BIOLOGICAL SCIENCES↗

Spatiotemporal Monte Carlo transport methods in x-ray semiconductor detectors: Application to pulse-height spectroscopy in a-Se

Purpose: The authors describe a detailed Monte Carlo (MC) method for the coupled transport of ionizing particles and charge carriers in amorphous selenium (a-Se) semiconductor x-ray detectors, and model the effect of statistical variations on the detected signal. Methods: A detailed transport code was developed for modeling the signal formation process in semiconductor x-ray detectors. The charge transport routines include three-dimensional spatial and temporal models of electron-hole pair transport taking into account recombination and trapping. Many electron-hole pairs are created simultaneously in bursts from energy deposition events. Carrier transport processes include drift due to external field and Coulombic interactions, and diffusion due to Brownian motion. Results: Pulse-height spectra (PHS) have been simulated with different transport conditions for a range of monoenergetic incident x-ray energies and mammography radiation beam qualities. Two methods for calculating Swank factors from simulated PHS are shown, one using the entire PHS distribution, and the other using the photopeak. The latter ignores contributions from Compton scattering and K-fluorescence. Comparisons differ by approximately 2% between experimental measurements and simulations. Conclusions: The a-Se x-ray detector PHS responses simulated in this work include three-dimensional spatial and temporal transport of electron-hole pairs. These PHS were used to calculate the Swank factor and compare it with experimental measurements. The Swank factor was shown to be a function of x-ray energy and applied electric field. Trapping and recombination models are all shown to affect the Swank factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-term leaf C:N ratio change under elevated CO 2 and nitrogen deposition in China: Evidence from observations and process-based modeling

Climate change, elevating atmosphere CO 2 (eCO 2 ) and increased nitrogen deposition (iNDEP) are altering the biogeochemical interactions between plants, microbes and soils, which further modify plant leaf carbon-nitrogen (C:N) stoichiometry and their carbon assimilation capability. Many field experiments have observed large sensitivity of leaf C:N ratio to eCO 2 and iNDEP. However, the large-scale pattern of this sensitivity is still unclear, because eCO 2 and iNDEP drive leaf C:N ratio toward opposite directions, which are further compounded by the complex processes of nitrogen acquisition and plant-and-microbial nitrogen competition. Here, we attempt to map the leaf C:N ratio spatial variation in the past 5 decades in China with a combination of data-driven model and process-based modeling. These two approaches showed consistent results. Over different regions, we found that leaf C:N ratio had significant but uneven changes between 2 time periods (1960-1989 and 1990-2015): a 5% ± 8% increase for temperate grasslands in northern China, a 3% ± 6% increase for boreal grasslands in western China, and by contrast, a 7% ± 6% decrease for temperate forests in southern China, and a 3% ± 5% decrease for boreal forests in northeastern China. Additionally, the structural equation models indicated that the leaf C:N change was sensitive to ΔNDEP, ΔCO 2 and ΔMAT rather than ΔMAP and ecosystem types. In this work, process-based modeling suggested that iNDEP was the main source of soil mineral nitrogen change, dominating leaf C:N ratio change in most areas in China, while eCO 2 led to leaf C:N ratio increase in low iNDEP area. This study also indicates that the long-term leaf C:N ratio acclimation was dominated by climate constraint, especially temperature, but was constrained by soil N availability over decade scale.

54 ENVIRONMENTAL SCIENCES↗