Search NASA⌕ Search

SEARCH · Search NASA

Results for “System Reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Surface heat flux feedback controlled impurity seeding experiments with Alcator C-Mod's high-Z vertical target plate divertor: performance, limitations and implications for fusion power reactors

The Alcator C-Mod team has recently developed a feedback system to measure and control surface heat flux in real-time. The system uses real-time measurements of surface heat flux from surface thermocouples and a pulse-width modulated piezo valve to inject low-Z impurities (typically N 2 ) into the private flux region. It has been used in C-Mod to mitigate peak surface heat fluxes >40 MW m -2 down to <10 MW m -2 while maintaining excellent core confinement, H 98 > 1. While the system works quite well under relatively steady conditions, use of it during transients has revealed important limitations on feedback control of impurity seeding in conventional vertical target plate divertors. In some cases, the system is unable to avoid plasma reattachment to the divertor plate or the formation of a confinement-damaging x-point MARFE. This is due to the small operational window for mitigated heat flux in the parameters of incident plasma heat flux, plasma density, and impurity density as well as the relatively slow response of the impurity gas injection system compared to plasma transients. Given the severe consequences for failure of such a system to operate reliably in a reactor, there is substantial risk that the conventional vertical target plate divertor will not provide an adequately controllable system in reactor-class devices. Finally, these considerations motivate the need to develop passively stable, highly compliant divertor configurations and experimental facilities that can test such possible solutions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comprehensive AI-based System for Control, Sensor Estimation, and Fault Detection of Cascaded Multilevel Inverters

In this paper, an Artificial Intelligence-based (AI) system is proposed for an 11-level cascaded H-bridge multilevel inverter (MLI) with the aims of harmonic suppression and reliability enhancement. The system consists of three seamlessly integrated Neural Networks (NNs). First, a multilayer perceptron is used to generalize the optimal switching angles for selective harmonic elimination under non-equal DC voltages. Next, an autoencoder NN estimates the voltage sensor readings to address potential drifting. Finally, a perceptron NN detects inverter faults based solely on the output voltage of the MLI. Simulation scenarios were evaluated, and the results show that the proposed system provides a comprehensive solution for the robust operation of the MLI. The proposed solution is capable of minimizing the targeted harmonics orders with minimal impact on the fundamental voltage, even when the voltage sensor drifts. Furthermore, the inverter under fault conditions was successfully identified.

Rezende da Costa Reis Kimpara, Renata↗

Surface heat flux feedback controlled impurity seeding experiments with Alcator C-Mod’s high-Z vertical target plate divertor: performance, limitations and implications for fusion power reactors

The Alcator C-Mod team has recently developed a feedback system to measure and control surface heat flux in real-time. The system uses real-time measurements of surface heat flux from surface thermocouples and a pulse-width modulated piezo valve to inject low-Z impurities (typically N2) into the private flux region. It has been used in C-Mod to mitigate peak surface heat fluxes >40 MW/m2 down to <10 MW/m2 while maintaining excellent core confinement, H98>1. While the system works quite well under relatively steady conditions, use of it during transients has revealed important limitations on feedback control of impurity seeding in conventional vertical target plate divertors. In some cases, the system is unable to avoid plasma reattachment to the divertor plate or the formation of a confinement-damaging x-point MARFE. This is due to the small operational window for mitigated heat flux in the parameters of incident plasma heat flux, plasma density, and impurity density as well as the relatively slow response of the impurity gas injection system compared to plasma transients. Given the severe consequences for failure of such a system to operate reliably in a reactor, there is substantial risk that the conventional vertical target plate divertor will not provide an adequately controllable system in reactor-class devices. These considerations motivate the need to develop passively stable, highly compliant divertor configurations and experimental facilities that can test such possible solutions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toward Interpreting Failure in Sintered-Silver Interconnection Systems

The mechanical strength and subsequent reliability of a sintered-silver interconnection system is a function of numerous independent parameters. That system is still undergoing process development. Most of those parameters (e.g., choice of plating) are arguably and unfortunately taken for granted and are independent of the silver s cohesive strength. To explore such effects, shear strength testing and failure analyses were completed on a simple, mock sintered-silver interconnection system consisting of bonding two DBC ceramic substrates. Silver and gold platings were part of the test matrix, as was pre-drying strategies, and the consideration of stencil-printing vs. screen-printing. Shear strength of sintered-silver interconnect systems was found to be was insensitive to the choice of plating, drying practice, and printing method provided careful and consistent processing of the sintered-silver are practiced. But if the service stress in sintered silver interconnect systems is anticipated to exceed ~ 60 MPa, then the system will likely fail.

Wereszczak, Andrew A↗

HPC application fault-tolerance using transparent redundant computation.

As the core count of HPC machines continue to grow in size, issues such as fault tolerance and reliability are becoming limiting factors for application scalability. Current techniques to ensure progress across faults, for example coordinated checkpoint-restart, are unsuitable for machines of this scale due to their predicted high overheads. In this study, we present the design and implementation of a novel system for ensuring reliability which uses transparent, rank-level, redundant computation. Using this system, we show the overheads involved in redundant computation for a number of real-world HPC applications. Additionally, we relate the communication characteristics of an application to the overheads observed.

97 MATHEMATICS AND COMPUTING↗

Modeling Single Well Injection-Withdrawal (SWIW) Tests for Characterization of Complex Fracture-Matrix Systems

The ability to reliably predict flow and transport in fractured porous rock is an essential condition for performance evaluation of geologic (underground) nuclear waste repositories. In this report, a suite of programs (TRIPOLY code) for calculating and analyzing flow and transport in two-dimensional fracture-matrix systems is used to model single-well injection-withdrawal (SWIW) tracer tests. The SWIW test, a tracer test using one well, is proposed as a useful means of collecting data for site characterization, as well as estimating parameters relevant to tracer diffusion and sorption. After some specific code adaptations, we numerically generated a complex fracture-matrix system for computation of steady-state flow and tracer advection and dispersion in the fracture network, along with solute exchange processes between the fractures and the porous matrix.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance evaluation of stand alone hybrid PV-wind generator

This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Risk-informed Graded Approach for Reliability and Performance Assessment of Sensor and Instrumentation Systems within Advanced Condition Monitoring Technologies

Advanced condition monitoring (ACM) technologies, such as digital twins, are innovative strategies designed to provide real-time health insights, including the remaining useful life of components. The primary goal of ACM is to predict and alert operators to potential functional failures before they occur. ACM systems achieve this by integrating predictive models with various sensor instrumentation, analog-to-digital converters, data warehouses, and data pre-processors. These sensor and instrumentation systems (SIS) are essential for forming a comprehensive understanding of component conditions and ensuring the predictive success of ACM programs. Introducing new technologies like ACM involves varying degrees of risk that can impact plant reliability. Therefore, risk mitigation should be commensurate with the performance and reliability of the developed technology, following a risk-informed graded approach (RIGA). Establishing a RIGA process requires a clear understanding of the hazards and reliability of all subsystems, including their interdependencies and potential impacts on the overall system. Given the critical role of SIS in ACM, this work reviews hazard identification and reliability quantification methods for SIS. It also considers these methods' implications when developing a RIGA process for ACM.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermomechanical Reliability Investigation of Large Temperature Excursions in Power Electronics Packages

This study confirms that high stresses between the metallization layer and ceramic lead to significant failures in DBC substrate. The driving forces behind several different failure modes are discussed. Further understanding of these failure mechanisms enables the modules to be engineered for longtime operation and helps to enhance the reliability of system-level operation.

36 MATERIALS SCIENCE↗

Review of Technical Photovoltaic Key Performance Indicators and the Importance of Data Quality Routines

Technical key performance indicators (KPIs) are important metrics used to assess and quantitatively summarize various aspects of photovoltaic (PV) systems, including long-term performance, economic viability, and carbon footprint. Herein, a group of experts of the International Energy Agency's Photovoltaic Power Systems Programme Task 13 collect and describ the most important technical KPIs used in the industry. Thereby, a set of best practices for reliably handling PV system data is presented and the impact of data quality and climatic variability on KPI calculation is investigated. Further, the effective use of technical KPIs allows triggering data-driven and informed decisions to optimize PV systems and providing a comprehensive overview of how PV systems operate across different conditions and climates. With the worldwide growth of the PV industry, more companies operate/own PV systems in different regions, where the climatic and seasonal profiles differ. This requires context-aware evaluation of KPIs, or the judicious application of multiple KPIs, to ensure that each asset is evaluated correctly. Beyond that, there is untapped potential in the utilization of KPIs through geospatial mapping and extrapolation of fleet KPIs. This study demonstrates that the uncertainty in KPI estimation is not well understood and depends on data quality, climatic variability, and system configuration.

14 SOLAR ENERGY↗

Platform for Automated Anomaly Detection in the Mercury Process System at the Target System in the Spallation Neutron Source

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory accelerates proton beams, which are directed toward a mercury target to generate the world’s most intense neutron beams via spallation. The target system consists of several interconnected subsystems and accounts for a major share of the facility’s overall downtime. Early detection of anomalies in the target system response can thus provide the possibility of taking corrective actions to reduce downtime. Accelerator facilities have largely focused on the beam side for data-driven fault prognostics. On the target side, SNS relies on operational shift technicians (OSTs), who respond to alarms and manually flag anomalies onto the System Tracking and Reliability (STAR) platform. This paper presents one of the first studies of using machine learning (ML) to automate anomaly detection in the target system. The study focused on the mercury process system as the first use case and employed reconstruction-based anomaly detection on minutely sampled time series signals. The pipeline was integrated into the STAR platform to autonomously rank and flag anomalies every week. The STAR platform provides a user interface for the OSTs to evaluate the flagged anomalies, thereby incorporating human feedback.

Anomaly detection↗

Validation of a Statistical Methodology for Extracting Vegetation Feedbacks: Focus on North African Ecosystems in the Community Earth System Model

Generalized equilibrium feedback assessment (GEFA) is a potentially valuable multivariate statistical tool for extracting vegetation feedbacks to the atmosphere in either observations or coupled Earth system models. The reliability of GEFA at capturing the terrestrial impacts on regional climate is demonstrated here using the National Center for Atmospheric Research Community Earth System Model (CESM), with focus on North Africa. The feedback is assessed statistically by applying GEFA to output from a fully coupled control run. To reduce the sampling error caused by short data records, the traditional or full GEFA is refined through stepwise GEFA by dropping unimportant forcings. Two ensembles of dynamical experiments are developed for the Sahel or West African monsoon region against which GEFA-based vegetation feedbacks are evaluated. In these dynamical experiments, regional leaf area index (LAI) is modified either alone or in conjunction with soil moisture, with the latter runs motivated by strong regional soil moisture–LAI coupling. Stepwise GEFA boasts higher consistency between statistically and dynamically assessed atmospheric responses to land surface anomalies than full GEFA, especially with short data records. GEFA-based atmospheric responses are more consistent with the coupled soil moisture–LAI experiments, indicating that GEFA is assessing the combined impacts of coupled vegetation and soil moisture. Both the statistical and dynamical assessments reveal a negative vegetation–rainfall feedback in the Sahel associated with an atmospheric stability mechanism in CESM versus a weaker positive feedback in the West African monsoon region associated with a moisture recycling mechanism in CESM.

54 ENVIRONMENTAL SCIENCES↗

An Architectural Survey of the REECo Maintenance Compound, Area 6, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to install a 26.45-mile-long 138-kilovolt (kV) transmission line on the Nevada National Security Site (NNSS) in Nye County, Nevada. This new transmission line will upgrade the electrical transmission system and provide reliable power between Mercury Switching Station in Area 23 and the U1a Facility in Area 1. The proposed upgrade to the power transmission system constitutes an undertaking subject to review under Section 106 of the National Historic Preservation Act (NHPA) (54 United States Code [USC] § 306101) and its implementing regulations, 36 Code of Federal Regulations (CFR) Part 800. A portion of this new transmission line will cross the western perimeter of the Reynolds Electrical and Engineering Company (REECo) Maintenance Compound located in Area 6 of the NNSS. This compound with its trade shops, storage sheds, and yards served as a general construction facility that supported nuclear testing activities on the NNSS from 1967 to 1992. Although three architectural resources in the compound have previously been recorded and evaluated for the National Register of Historic Places (NRHP), other resources within it have not, nor has the compound been recorded and evaluated as a potential district. The State Historic Preservation Officer (SHPO) concurred with NNSA/NFO’s determination that the unevaluated REECo Maintenance Compound will be adversely affected by the proposed undertaking (Reed 2021). The NNSA/NFO, in consultation with the SHPO, then developed the Memorandum of Agreement DE-GM58-22NA25553 between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Installation of a 138-kilovolt Transmission Line from the Mercury Switching Station to the U1a Facility and the Removal of the Historic 138-kilovolt Transmission Line from the Mercury Switching Station to the U1a Facility in Areas 1, 3, 5, 6, and 23 of the Nevada National Security Site, Nye County, hereafter referred to as the MOA. This architectural survey report was prepared in accordance with MOA Stipulation III.B. It describes the origins, history, layout, and functions of the REECo Maintenance Compound during the Cold War and identifies contributing and noncontributing resources. The report defines a district boundary based on archival research and the field survey and concludes with an appendix that presents digital color images of the compound with descriptions and a map key showing image viewpoints and directions. Although none of the architectural resources are recommended individually eligible, the district evaluation concludes the REECo Maintenance Compound is eligible as a historic district for listing in the NRHP under the Secretary of the Interior’s Significance Criteria A and C at the local level. The historic district retains all seven aspects of integrity and conveys its significance under the abovementioned criteria.

138 kV↗

Data Centers Gap Analysis [Slides]

Data centers and other large loads are a significant driver of unprecedented, near-term demand growth in the United States. Power system planners, utilities, regulators, and other stakeholders are grappling with how to integrate data centers on the system without comprising reliability, resiliency, and energy affordability. NLR is pursuing work to develop a siting and decision-making tool that would draw on power systems modeling expertise to achieve granular representation of trade-offs involved in data center sitting and development. This slide deck supports the same workstream by reviewing the literature to identify mitigation options to facilitate near-term integration of large loads and by presenting options for pursuing data development and/or modeling projects to improve representation of siting options.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enhanced FIB-SEM systems for large-volume 3D imaging

Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) can automatically generate 3D images with superior z-axis resolution, yielding data that needs minimal image registration and related post-processing. Obstacles blocking wider adoption of FIB-SEM include slow imaging speed and lack of long-term system stability, which caps the maximum possible acquisition volume. Here, we present techniques that accelerate image acquisition while greatly improving FIB-SEM reliability, allowing the system to operate for months and generating continuously imaged volumes > 10 6 ?m 3 . These volumes are large enough for connectomics, where the excellent z resolution can help in tracing of small neuronal processes and accelerate the tedious and time-consuming human proofreading effort. Even higher resolution can be achieved on smaller volumes. We present example data sets from mammalian neural tissue, Drosophila brain, and Chlamydomonas reinhardtii to illustrate the power of this novel high-resolution technique to address questions in both connectomics and cell biology.

59 BASIC BIOLOGICAL SCIENCES↗

Renewable Energy Zone (REZ) Transmission Planning Process

A REZ is a geographical area that enables the development of profitable, cost-effective, grid-connected renewable energy (RE). The REZ Transmission Planning Process is a proactive approach to plan, approve, and build transmission infrastructure connecting REZs to the power system which helps to increase the share of solar, wind and other RE resources in the power system while maintaining reliability and economics, and focuses on large-scale wind and solar resources that can be developed in sufficient quantities to warrant transmission system expansion and upgrades.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Markov Model of Severe Accident Progression and Management

The earthquake and tsunami that hit the nuclear power plants at the Fukushima Daiichi site in March 2011 led to extensive fuel damage, including possible fuel melting, slumping, and relocation at the affected reactors. A so-called feed-and-bleed mode of reactor cooling was initially established to remove decay heat. The plan was to eventually switch over to a recirculation cooling system. Failure of feed and bleed was a possibility during the interim period. Furthermore, even if recirculation was established, there was a possibility of its subsequent failure. Decay heat has to be sufficiently removed to prevent further core degradation. To understand the possible evolution of the accident conditions and to have a tool for potential future hypothetical evaluations of accidents at other nuclear facilities, a Markov model of the state of the reactors was constructed in the immediate aftermath of the accident and was executed under different assumptions of potential future challenges. This work was performed at the request of the U.S. Department of Energy to explore 'what-if' scenarios in the immediate aftermath of the accident. The work began in mid-March and continued until mid-May 2011. The analysis had the following goals: (1) To provide an overall framework for describing possible future states of the damaged reactors; (2) To permit an impact analysis of 'what-if' scenarios that could lead to more severe outcomes; (3) To determine approximate probabilities of alternative end-states under various assumptions about failure and repair times of cooling systems; (4) To infer the reliability requirements of closed loop cooling systems needed to achieve stable core end-states and (5) To establish the importance for the results of the various cooling system and physical phenomenological parameters via sensitivity calculations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗