Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

FePtC magnetic recording media with (200) textured MoC intermediate layer

The FePt films with thickness of 4–10 nm were deposited on MoC/CrRu/glass at 425 °C by using magnetron sputtering. The Mo{sub 40}C{sub 60} target was used to form the MoC and C two phases after deposition. The MoC intermediate layer was epitaxially grown on the (200) textured CrRu seed layer at 425 °C and the MoC (200) diffraction peak was not clearly indexed below 10 nm but observed at 25 nm. Finally, the FePt film was prepared on (200) textured MoC at 425 °C and shown the strong (001) texture. Perpendicular anisotropy of 1.7 × 10{sup 7} erg/cm{sup 3} and out-of-plane coercivity of 7.5 kOe has been demonstrated in 10 nm thick FePt film. From microstructure, the FePt grains were distributed in- or between-islands like structure and further separated by excess carbon from MoC intermediate layer. Thinner FePt film was more separated by excess carbon and shown higher coercivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Conceptual Design of a Counter-Rotating Fan System for Distributed Boundary Layer Ingesting Propulsion

The present paper details the design of the counter rotating fans for a Turboelectric Distributed Propulsion (TeDP) system. Sixteen propulsors installed in mail-slot-shape nacelles are embedded on an aerodynamically optimized hybrid wing-body configuration. The hybrid-wing/body (HWB) configuration which was previously designed to satisfy the conditions of trim, longitudinally static stability and specific cargo space is employed as the baseline configuration in pursuing an optimal distributed propulsion system. A set of distributed propulsors is conceptually designed and the collective performance is evaluated against the target thrust mandated by the mission requirements. The concept of the distributed propulsion allows the fan pressure ratio to be around 1.27~1.32 for the target thrust. In addition, further splitting of the fan pressure ratio by using the counter-rotating fans for each slot realizes the target pressure ratio with low tip speed. In the distributed propulsion system, the nature of the flow conditions and/or the thickness of the ingested boundary layer may differ and result in different propulsive reaction of each individual propulsor. The optimization is, thus, approached from both the propulsion system and individual propulsor perspectives. An optimal distribution of the thrust and power output is determined by how the system utilizes each passage's propulsive characteristics and its interaction with the airframe. These system level analysis and optimization are conducted using an actuator disk model to account for the propulsion-airframe integration numerically. With respect to the propulsor level, aerodynamic shape optimizations of the fan blades are performed in a sequential multi-objective optimization process for various design objectives, such as mass flow rate condition, fan pressure ratio, efficiency and the exit flow angle of the fan stage by using a genetic algorithm, NSGA-II. The radial chord distribution, and meanline distribution of the rotors are designed on the circumferentially averaged axi-symmetric inlet profiles and tested on the six inlet profiles from six divided sectors to reckon flow distortion. The performances of the counter rotating fans are, thus, evaluated accordingly for obtaining distortion tolerant fan. The performance of the distributed propulsion system is evaluated by two CFD tools, i.e., a multi-stage turbo-machinery CFD code and one propulsion-airframe integration flow solver coupled with a body-force model. The optimized boundary layer ingestion propulsion system of 16 distributed slots not only reaches the system target thrust, but also delivers a close to 20% fuel saving benefit against its counterpart 12 distributed clean inlet propulsion system.

Boundary-Layer-Ingestion Propulsion↗

Pulsed laser deposition to synthesize the bridge structure of artificial nacre: Comparison of nano- and femtosecond lasers

Nature offers inspiration to new adaptive technologies that allow us to build amazing shapes and structures such as nacre using synthetic materials. Consequently, we have designed a pulsed laser ablation manufacturing process involving thin film deposition and micro-machining to create hard/soft layered 'brick-bridge-mortar' nacre of AlMgB{sub 14} (hard phase) with Ti (soft phase). In this paper, we report pulsed laser deposition (PLD) to mimic brick and bridge structures of natural nacre in AlMgB{sub 14}. Particulate formation inherent in PLD is exploited to develop the bridge structure. Mechanical behavior analysis of the AlMgB{sub 14}/Ti system revealed that the brick is to be 250 nm thick, 9 {mu}m lateral dimensions while the bridge (particle) is to have a diameter of 500 nm for a performance equivalent to natural nacre. Both nanosecond (ns) and femtosecond (fs) pulsed lasers were employed for PLD in an iterative approach that involves varying pulse energy, pulse repetition rate, and target-to-substrate distance to achieve the desired brick and bridge characteristics. Scanning electron microscopy, x-ray photoelectron spectroscopy, and optical profilometer were used to evaluate the film thickness, particle size and density, stoichiometry, and surface roughness of thin films. Results indicated that both ns-pulsed and fs-pulsed lasers produce the desired nacre features. However, each laser may be chosen for different reasons: fs-pulsed laser is preferred for much shorter deposition time, better stoichiometry, uniform-sized particles, and uniform film thickness, while ns-pulsed laser is favored for industrial acceptance, reliability, ease of handling, and low cost.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TH-E-17A-04: Geometric Validation of K-Space Self-Gated 4D-MRI Vs. 4D-CT Using A Respiratory Motion Phantom

Purpose: 4D-CT is often limited by motion artifacts, low temporal resolution, and poor phase-based target definition. We recently developed a novel k-space self-gated 4D-MRI technique with high spatial and temporal resolution. The goal here is to geometrically validate 4D-MRI using a MRI-CT compatible respiratory motion phantom and comparison to 4D-CT. Methods: 4D-MRI was acquired using 3T spoiled gradient echo-based 3D projection sequences. Respiratory phases were resolved using self-gated k-space lines as the motion surrogate. Images were reconstructed into 10 temporal bins with 1.56×1.56×1.56mm3. A MRI-CT compatible phantom was designed with a 23mm diameter ball target filled with highconcentration gadolinium(Gd) gel embedded in a 35×40×63mm3 plastic box stabilized with low-concentration Gd gel. The whole phantom was driven by an air pump. Human respiratory motion was mimicked using the controller from a commercial dynamic phantom (RSD). Four breathing settings (rates/depths: 10s/20mm, 6s/15mm, 4s/10mm, 3s/7mm) were scanned with 4D-MRI and 4D-CT (slice thickness 1.25mm). Motion ground-truth was obtained from input signals and real-time video recordings. Reconstructed images were imported into Eclipse(Varian) for target contouring. Volumes and target positions were compared with ground-truth. Initial human study was investigated on a liver patient. Results: 4D-MRI and 4D-CT scans for the different breathing cycles were reconstructed with 10 phases. Target volume in each phase was measured for both 4D-CT and 4D-MRI. Volume percentage difference for the 6.37ml target ranged from 6.67±5.33 to 11.63±5.57 for 4D-CT and from 1.47±0.52 to 2.12±1.60 for 4D-MRI. The Mann-Whitney U-test shows the 4D-MRI is significantly superior to 4D-CT (p=0.021) for phase-based target definition. Centroid motion error ranges were 1.35–1.25mm (4D-CT), and 0.31–0.12mm (4D-MRI). Conclusion: The k-space self-gated 4D-MRI we recently developed can accurately determine phase-based target volume while avoiding typical motion artifacts found in 4D-CT, and is being further studied for use in GI targeting and motion management. This work supported in part by grant 1R03CA173273-01.

60 APPLIED LIFE SCIENCES↗

Epitaxial niobium dioxide thin films by reactive-biased target ion beam deposition

Epitaxial NbO{sub 2} thin films were synthesized on Al{sub 2}O{sub 3} (0001) substrates via reactive bias target ion beam deposition. X-ray diffraction and Raman spectra were used to confirm the tetragonal phase of pure NbO{sub 2}. Through XPS, it was found that there was a ∼1.3 nm thick Nb{sub 2}O{sub 5} layer on the surface and the bulk of the thin film was NbO{sub 2}. The epitaxial relationship between the NbO{sub 2} film and the substrate was determined. Electrical transport measurement was measured up to 400 K, and the conduction mechanism was discussed.

36 MATERIALS SCIENCE↗

Absolute cross section for loss of supercoiled topology induced by 10 eV electrons in highly uniform /DNA/1,3-diaminopropane films deposited on highly ordered pyrolitic graphite

It was recently shown that the affinity of doubly charged, 1-3 diaminopropane (Dap{sup 2+}) for DNA permits the growth on highly ordered pyrolitic graphite (HOPG) substrates, of plasmid DNA films, of known uniform thickness [O. Boulanouar, A. Khatyr, G. Herlem, F. Palmino, L. Sanche, and M. Fromm, J. Phys. Chem. C 115, 21291–21298 (2011)]. Post-irradiation analysis by electrophoresis of such targets confirms that electron impact at 10 eV produces a maximum in the yield of single strand breaks that can be associated with the formation of a DNA{sup −} transient anion. Using a well-adapted deterministic survival model for the variation of electron damage with fluence and film thickness, we have determined an absolute cross section for strand-break damage by 10 eV electrons and inelastic scattering attenuation length in DNA-Dap complex films.

36 MATERIALS SCIENCE↗

Effect of Tritium-Induced Damage on Plastic Targets from High-Density DT Permeation

Direct-drive inertial fusion experiments conducted at the Laboratory for Laser Energetics implode 860-μm-diam, 8-μm-thick glow-discharge polymer (GDP) capsules that have a solid, uniform, 60- to 80-μm-thick layer of an equimolar mixture of deuterium and tritium (DT) on their interior. The DT is permeated through the capsule’s wall up to pressures of 1000 atm in small pressure steps to prevent buckling; this occurs over many hours. The capsule is then cooled, the DT is solidified, and the uniform layer is formed using thermal gradients produced by heat deposited from beta decay of the tritium. Thermal contraction of the capsule from cooling is expected to be ~1% of the diameter. Capsules permeated with DT do not exhibit this contraction and retain their room-temperature diameter after cooling. Sources of error in the imaging system were explored, and a systematic 3 μm over measurement of the diameter was revealed and corrected. However, both GDP capsules permeated with only deuterium and polystyrene capsules permeated with DT do exhibit thermal contraction. The highly cross-linked GDP shell is under compressive stress after fabrication and experiences bond breakage when exposed to high-density DT during permeation. It is speculated that some of this compressive stress is relieved during bond cleavage and the capsule’s wall swells, which counteracts contraction during cooling. In addition, mass spectrometry of the DT gas in the permeation system has revealed the presence of hydrocarbons and other carbon-containing species that increase with time, confirming the radio-degradation of the polymer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of shockless dynamic compression data on solids to multi-megabar pressures: Application to tantalum

Magnetically-driven, planar shockless-compression experiments to multi-megabar pressures were performed on tantalum samples using a stripline target geometry. Free-surface velocity waveforms were measured in 15 cases; nine of these in a dual-sample configuration with two samples of different thicknesses on opposing electrodes, and six in a single-sample configuration with a bare electrode opposite the sample. Details are given on the application of inverse Lagrangian analysis (ILA) to these data, including potential sources of error. The most significant source of systematic error, particularly for single-sample experiments, was found to arise from the pulse-shape dependent free-surface reflected wave interactions with the deviatoric-stress response of tantalum. This could cause local, possibly temporary, unloading of material from a ramp compressed state, and thus multi-value response in wave speed that invalidates the free-surface to in-material velocity mapping step of ILA. By averaging all 15 data sets, a final result for the principal quasi-isentrope of tantalum in stress-strain was obtained to a peak longitudinal stress of 330 GPa with conservative uncertainty bounds of ±4.5% in stress. The result agrees well with a tabular equation of state developed at Los Alamos National Laboratory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A high yield neutron target for cancer therapy

A rotating target was developed that has the potential for providing an initial yield of 10 to the 13th power neutrons per second by the T(d,n)He-4 reaction, and a useable lifetime in excess of 600 hours. This yield and lifetime are indicated for a 300 Kv and 30 mA deuteron accelerator and a 30 microns thick titanium tritide film formed of the stoichiometric compound TiT2. The potential for extended lifetime is made possible by incorporating a sputtering electrode that permits use of titanium tritide thicknesses much greater than the deuteron range. The electrode is used to remove in situ depleted titanium layers to expose fresh tritide beneath. The utilization of the rotating target as a source of fast neutrons for cancer therapy is discussed.

Alger, D. L.↗

Gold nanoparticle-aided brachytherapy with vascular dose painting: Estimation of dose enhancement to the tumor endothelial cell nucleus

Purpose: Theoretical microdosimetry at the subcellular level is employed in this study to estimate the dose enhancement to tumor endothelial cell nuclei, caused by radiation-induced photo/Auger electrons originating from gold nanoparticles (AuNPs) targeting the tumor endothelium, during brachytherapy. Methods: A tumor vascular endothelial cell (EC) is modeled as a slab of 2 {mu}m (thickness) x 10 {mu}m (length) x 10 {mu}m (width). The EC contains a nucleus of 5 {mu}m diameter and thickness of 0.5-1 {mu}m, corresponding to nucleus size 5%-10% of cellular volume, respectively. Analytic calculations based on the electron energy loss formula of Cole were carried out to estimate the dose enhancement to the nucleus caused by photo/Auger electrons from AuNPs attached to the exterior surface of the EC. The nucleus dose enhancement factor (nDEF), representing the ratio of the dose to the nucleus with and without the presence of gold nanoparticles was calculated for different AuNP local concentrations. The investigated concentration range considers the potential for significantly higher local concentration near the EC due to preferential accumulation of AuNP in the tumor vasculature. Four brachytherapy sources: I-125, Pd-103, Yb-169, and 50 kVp x-rays were investigated. Results: For nucleus size of 10% of the cellular volume and AuNP concentrations ranging from 7 to 140 mg/g, brachytherapy sources Pd-103, I-125, 50 kVp, and Yb-169 yielded nDEF values of 5.6-73, 4.8-58.3, 4.7-56.6, and 3.2-25.8, respectively. Meanwhile, for nucleus size 5% of the cellular volume in the same concentration range, Pd-103, I-125, 50 kVp, and Yb-169 yielded nDEF values of 6.9-79.2, 5.1-63.2, 5.0-61.5, and 3.3-28.3, respectively. Conclusions: The results predict that a substantial dose boost to the nucleus of endothelial cells can be achieved by applying tumor vasculature-targeted AuNPs in combination with brachytherapy. Such vascular dose boosts could induce tumor vascular shutdown, prompting extensive tumor cell death.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Precision grid and hand motion for accurate needle insertion in brachytherapy

Purpose: In prostate brachytherapy, a grid is used to guide a needle tip toward a preplanned location within the tissue. During insertion, the needle deflects en route resulting in target misplacement. In this paper, 18-gauge needle insertion experiments into phantom were performed to test effects of three parameters, which include the clearance between the grid hole and needle, the thickness of the grid, and the needle insertion speed. Measurement apparatus that consisted of two datum surfaces and digital depth gauge was developed to quantify needle deflections. Methods: The gauge repeatability and reproducibility (GR and R) test was performed on the measurement apparatus, and it proved to be capable of measuring a 2 mm tolerance from the target. Replicated experiments were performed on a 2{sup 3} factorial design (three parameters at two levels) and analysis included averages and standard deviation along with an analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: Results showed that grid with tight clearance hole and slow needle speed increased precision and accuracy of needle insertion. The tight grid was vital to enhance precision and accuracy of needle insertion for both slow and fast insertion speed; additionally, at slow speed the tight, thick grid improved needle precision and accuracy. Conclusions: In summary, the tight grid is important, regardless of speed. The grid design, which shows the capability to reduce the needle deflection in brachytherapy procedures, can potentially be implemented in the brachytherapy procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ion acceleration from microstructured targets irradiated by high-intensity picosecond laser pulses

Structures on the front surface of thin foil targets for laser-driven ion acceleration have been proposed to increase the ion source maximum energy and conversion efficiency. While structures have been shown to significantly boost the proton acceleration from pulses of moderate-energy fluence, their performance on tightly focused and high-energy lasers remains unclear. Here, we report the results of laser-driven three-dimensional (3D)-printed microtube targets, focusing on their efficacy for ion acceleration. Using the high-contrast (~10 12) PHELIX laser (150 J, 10 21 W / cm 2 ), we studied the acceleration of ions from 1-μm-thick foils covered with micropillars or microtubes, which we compared with flat foils. The front-surface structures significantly increased the conversion efficiency from laser to light ions, with up to a factor of 5 higher proton number with respect to a flat target, albeit without an increase of the cutoff energy. An optimum diameter was found for the microtube targets. Our findings in this work are supported by a systematic particle-in-cell modeling investigation of ion acceleration using 2D simulations with various structure dimensions. Simulations reproduce the experimental data with good agreement, including the observation of the optimum tube diameter, and reveal that the laser is shuttered by the plasma filling the tubes, explaining why the ion cutoff energy was not increased in this regime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improvements in Critical Dosimetric Endpoints Using the Contura Multilumen Balloon Breast Brachytherapy Catheter to Deliver Accelerated Partial Breast Irradiation: Preliminary Dosimetric Findings of a Phase IV Trial

Purpose: Dosimetric findings in patients treated with the Contura multilumen balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) on a multi-institutional Phase IV registry trial are presented. Methods and Materials: Computed tomography-based three-dimensional planning with dose optimization was performed. For the trial, new ideal dosimetric goals included (1) {>=}95% of the prescribed dose (PD) covering {>=}90% of the target volume, (2) a maximum skin dose {<=}125% of the PD, (3) maximum rib dose {<=}145% of the PD, and (4) the V150 {<=}50 cc and V200 {<=}10 cc. The ability to concurrently achieve these dosimetric goals using the Contura MLB was analyzed. Results: 144 cases were available for review. Using the MLB, all dosimetric criteria were met in 76% of cases. Evaluating dosimetric criteria individually, 92% and 89% of cases met skin and rib dose criteria, respectively. In 93% of cases, ideal target volume coverage goals were met, and in 99%, dose homogeneity criteria (V150 and V200) were satisfied. When skin thickness was {>=}5 mm to <7 mm, the median skin dose was limited to 120.1% of the PD, and when skin thickness was <5 mm, the median skin dose was 124.2%. When rib distance was <5 mm, median rib dose was reduced to 136.5% of the PD. When skin thickness was <7 mm and distance to rib was <5 mm, median skin and rib doses were jointly limited to 120.6% and 142.1% of the PD, respectively. Conclusion: The Contura MLB catheter provided the means of achieving the imposed higher standard of dosimetric goals in the majority of clinical scenarios encountered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The CLAS12 Central Time-of-Flight system

The Central Time-of-Flight system for the large-acceptance CLAS12 spectrometer in Hall B at the Thomas Jefferson National Accelerator Facility is described. The system consists of a hermetic barrel of 48 scintillation counters at a radius of 25 cm from the beamline. The wedge-shaped counters are 3.4 cm wide, 3.0 cm thick, and 90 cm long, and span a range of polar angles relative to the center of the nominal target location from roughly 35° to 125°. The counters reside in the 5-T field of the CLAS12 superconducting solenoid. The bars are read out via bent light guides 1 m long on the upstream end of the counters and 1.6 m long on the downstream end. The phototubes are shielded by a multi-layer dynamical magnetic shield system to reduce the local fringe fields in the range from 400 G to 1000 G down to the level of 0.2 G at the location of the photocathodes. The average effective time resolution of the counters is 80 ps.

47 OTHER INSTRUMENTATION↗

{sup 55}Co separation from proton irradiated metallic nickel

{sup 55}Co with > 97% radionuclidic purity 24 hours after end of bombardment (EoB) was produced from the {sup 58}Ni(p,α) reaction using proton irradiations of 16 MeV on natural nickel. Two-hour irradiations with 25 μA on a 254 μm thick nickel foil generate 0.18 ± 0.01 GBq (n = 3) 24 hours after EoB. The separation of cobalt from the target material and other metallic contaminants present at trace levels is accomplished in HCl medium by two rounds of anion exchange chromatography (AG1-X8) using an automated module driven by a peristaltic pump. 80 ± 5 % (n = 3) of the activity generated at EoB is ready for labeling in 0.1 M HCl one hour after the start of separation. Using 99.999% pure Ni, the reactivity (decay corrected to EoB) with the bifunctional chelator (BFC) DOTA was 8.5 GBq/μmol; enough for radiolabeling BFC conjugated biomolecules at a nmol scale with > 90% yield. Using 99.9% pure Ni the reactivity with DOTA and NOTA was 0.19 +/− 0.09 GBq/μmol and 2.9 +/− 1.7 GBq/μmol (n = 2), respectively. Both cobalt complexes showed 100% in vitro stability in PBS and mouse serum over 41 hours at room temperature. MicroPET images of a miniature Derenzo phantom show excellent resolution where rods of 1.5 mm were separated by two times their diameter.

07 ISOTOPE AND RADIATION SOURCES↗

Observation of d(t,n) α Neutrons Following d(d,p)t Reactions in a Deuterium Gas Cell: An Attempt to Repeat Ruhlig’s 1938 Observation of Secondary Reactions

In order to benchmark methods used to calculate reaction-in-flight fusion reactions in inertial confinement fusion and address issues related to the first claimed observation of d(t,n)α reactions in 1938, secondary d(t,n)α reactions have been observed following d(d,p)t reactions in deuterium gas. A pulsed 200-nA, 2.2-MeV deuterium beam from the Triangle Universities Nuclear Laboratory FN tandem accelerator was injected into a cylindrical multiatmosphere deuterium gas target. The incident beam traversed along the target cylinder’s 3-cm symmetry axis after its passage through a Havar entrance foil. Two different Havar foil thicknesses were used to obtain 1.5- and 0.6-MeV deuteron beams entering the deuterium cell. The cylinder’s radius was 2 cm to allow for d(d,p)t tritons emitted perpendicular to the beam to range out in the deuterium gas. The neutron emission from the cell was observed via its time of flight to a liquid scintillator placed at various angles to the beam direction, at a distance of 243 cm. Pulse-shape-discrimination techniques were used to separate neutron and gamma-ray signals seen in the liquid scintillator. The observed probability of ~2 × 10 –4 for inducing secondary d(t,n)α fusion in the gas cell per d(d,p)t reaction is consistent with theoretical expectations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Final Report: Next Generation Diamond Drumhead X-Ray Optics

Problem / Opportunity Statement: Future high-impact scientific applications at synchrotron and Free-Electron Laser (FEL) X-ray sources require the development of processing and mounting methods for ultra-thin diamond crystals to meet the most challenging needs of pioneering research at next generation light source facilities. These methods should be capable of manufacturing crystal plates as thin as 10 micrometers over an area of a few mm2, and with a surface cut in different crystal orientations, such as the diamond {100}, {111}, {110} and {113} planes. Project Purpose and Approach: In Phase I, Great Lakes Crystal Technologies (GLCT) partnered with Stonybrook University (SUNY) to created thin diamond drumhead crystals. The purpose of the Phase I project is to transfer the drumhead membrane window etching technology from SUNY to GLCT. Testing of a device using the beamline at Stanford Linear Accelerator Laboratory was initially planned, however, a delay on the part of a third party service provided required us to get beamline testing done at Argonne National Laboratory. Phase I Taskwork: Testing of a high purity diamond plate thinning and etching process was performed. By SUNY and GLCT. Plates were sent to a third party service provider for thinning to ~100 microns, however, delays required that GLCT develop an in-house thinning process to complete the taskwork. GLCT successfully developed this in-house capability even though it was initially planned to be part of the Phase II Taskwork. Multiple practice and deliverable plates were provided to SUNY to be etched into the target drumhead devices. GLCT practiced and refined an in-house plate thinning process and produced five plates with thicknesses in the 60 – 150 micron range. Processing of the plates has begun and will continue in a no-cost extension period necessitated by the third party service provider delay. GLCT also procured and installed a reactive ion etching/inductively coupled plasma system. In addition, one of the thinned plates was measured at the Applied Photon Source at APL for a pre-processing assessment of the crystalline strain. After processing the plate into a drumhead and annealing, a post-processing assessment of the strain will be performed. Phase I Results: The initial data from GLCT’s plate thinning process development, SUNY’s drumhead etching processing, and characterization at APS/ANL demonstrate our teams capabilities to achieve the project goals. Commercial Applications & Benefits: The proposed technology will benefit advanced x-ray science performed at BNL and the 70+ additional advanced beamlines around the world. There are also a number of medical and homeland security applications which could benefit from the technology.

Quayle, Paul↗

Ion beam deposited silicon carbide on glass optics and replica gratings

The results of an attempt to coat optical flats and replace echelle gratings with ion-deposited SiC are reported. Deposition was performed by bombarding a SiC target with an ion beam angled 45 deg relative to the target. Half the target was covered with stainless steel to furnish a comparison opportunity. After precleaning SiC coatings of 300-2200 A thickness were deposited. The specimens had previously been coated with either Au or Al or were left blank. Reflectance and diffraction data were taken of the finished flats and gratings. The SiC-coated flats performed as well as uncoated flats while the echelles exhibited deteriorating performance with increasing coating thickness. Further studies are indicated on the effect of coating thickness on surface roughness.

Windt, D. L.↗