Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

A method for verification of treatment delivery in HDR prostate brachytherapy using a flat panel detector for both imaging and source tracking

Purpose: Verification of high dose rate (HDR) brachytherapy treatment delivery is an important step, but is generally difficult to achieve. A technique is required to monitor the treatment as it is delivered, allowing comparison with the treatment plan and error detection. In this work, we demonstrate a method for monitoring the treatment as it is delivered and directly comparing the delivered treatment with the treatment plan in the clinical workspace. This treatment verification system is based on a flat panel detector (FPD) used for both pre-treatment imaging and source tracking. Methods: A phantom study was conducted to establish the resolution and precision of the system. A pretreatment radiograph of a phantom containing brachytherapy catheters is acquired and registration between the measurement and treatment planning system (TPS) is performed using implanted fiducial markers. The measured catheter paths immediately prior to treatment were then compared with the plan. During treatment delivery, the position of the {sup 192}Ir source is determined at each dwell position by measuring the exit radiation with the FPD and directly compared to the planned source dwell positions. Results: The registration between the two corresponding sets of fiducial markers in the TPS and radiograph yielded a registration error (residual) of 1.0 mm. The measured catheter paths agreed with the planned catheter paths on average to within 0.5 mm. The source positions measured with the FPD matched the planned source positions for all dwells on average within 0.6 mm (s.d. 0.3, min. 0.1, max. 1.4 mm). Conclusions: We have demonstrated a method for directly comparing the treatment plan with the delivered treatment that can be easily implemented in the clinical workspace. Pretreatment imaging was performed, enabling visualization of the implant before treatment delivery and identification of possible catheter displacement. Treatment delivery verification was performed by measuring the source position as each dwell was delivered. This approach using a FPD for imaging and source tracking provides a noninvasive method of acquiring extensive information for verification in HDR prostate brachytherapy.

60 APPLIED LIFE SCIENCES↗

Potential Collaborative Research topics with Korea’s Agency for Defense Development

This presentation provides a high level summary of current research activities at the Los Alamos National Laboratory (LANL)-University of California Jacobs School of Engineering (UCSD) Engineering Institute that will be presented at Korea's Agency for Defense Development (ADD). These research activities are at the basic engineering science level with different level of maturity ranging from initial concepts to field proof-of-concept demonstrations. We believe that all of these activities are appropriate for collaborative research activities with ADD subject to approval by each institution. All the activities summarized herein have the common theme that they are multi-disciplinary in nature and typically involved the integration of high-fidelity predictive modeling, advanced sensing technologies and new development in information technology. These activities include: Wireless Sensor Systems, Swarming Robot sensor systems, Advanced signal processing (compressed sensing) and pattern recognition, Model Verification and Validation, Optimal/robust sensor system design, Haptic systems for large-scale data processing, Cyber-physical security for robots, Multi-source energy harvesting, Reliability-based approaches to damage prognosis, SHMTools software development, and Cyber-physical systems advanced study institute.

42 ENGINEERING↗

Multi-Reactor Transmutation Analysis Utility (MRTAU,alpha1): Verification

Multi-Reactor Transmutation Utility (MRTAU) is a general depletion/decay algorithm under development at INL to support quick assessment of off-normal fuel cycle scenarios of similar nature to well studied reactor and fuel cycle concepts for which isotopic and cross-section data exists. MRTAU has been used in the past for scoping calculations to determine actinide composition evolution over the course of multiple recycles in Light Water Reactor Mixed Oxide and Sodium cooled Fast Reactor. In these applications, various actinide partitioning scenarios of interest were considered. The code has recently been expanded to include fission product generation, depletion and isotopic evolution over multiple recycles. The capability was added to investigate potential partial separations and/or limited recycling technologies such as Melt-Refining, AIROX, DUPIC or other fuel recycle technology where the recycled fuel stream is not completely decontaminated of fission products prior to being re-irradiated in a subsequent reactor pass. This report documents the code's solution methodology and algorithm as well as its solution accuracy compared to the SCALE6.0 software suite.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Voxel-Based Dose Reconstruction for Total Body Irradiation With Helical TomoTherapy

Purpose: We have developed a megavoltage CT (MVCT)-based dose reconstruction strategy for total body irradiation (TBI) with helical TomoTherapy (HT) using a deformable registration model to account for the patient's interfraction changes. The proposed technique serves as an efficient tool for delivered dose verification and, potentially, plan adaptation. Methods and Materials: Four patients with acute myelogenous leukemia treated with TBI using HT were selected for this study. The prescription was 12 Gy, 2 Gy/fraction, twice per day, given at least 6 h apart. The original plan achieved coverage of 80% of the clinical target volume (CTV) by the 12 Gy isodose surface. MVCTs were acquired prior to each treatment. Regions of interest were contoured on each MVCT. The dose for each fraction was calculated based on the MVCT using the HT planned adaptive station. B-spline deformable registration was conducted to establish voxel-to-voxel correspondence between the MVCT and the planning CT. The resultant deformation vector was employed to map the reconstructed dose from each fraction to the same point as the plan dose, and a voxel-to-voxel summed dose from all six fractions was obtained. The reconstructed dose distribution and its dosimetric parameters were compared with those of the original treatment plan. Results: While changes in CTV contours occurred in all patients, the reconstructed dose distribution showed that the dose-volume histogram for CTV coverage was close (<1.5%) to that of the original plan. For sensitive structures, the differences between the reconstructed and the planned doses were less than 3.0%. Conclusion: Voxel-based dose reconstruction strategy that takes into account interfraction anatomical changes using MVCTs is a powerful tool for treatment verification of the delivered doses. This proposed technique can also be applied to adaptive TBI therapy using HT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Remaining Sites Verification Package for the 600-111, P-11 Critical Mass Laboratory Crib, and UPR-600-16, Fire and Contamination Spread Waste Sites, Waste Site Reclassification Form 2008-045

The UPR-600-16, Fire and Contamination Spread waste site is an unplanned release that occurred on December 4, 1951, when plutonium contamination was spread by a fire that ignited inside the 120 Experimental Building. The 120 Experimental Building was a laboratory building that was constructed in 1949 and used for plutonium criticality studies as part of the P-11 Project. In November 1951, a criticality occurred in the 120 Experimental Building that resulted in extensive plutonium contamination inside the building. The confirmatory evaluation supports a reclassification of this site to Interim Closed Out. The current site conditions achieve the remedial action objectives and the corresponding remedial action goals established in the Remaining Sites ROD. The results of the extensive radiological survey of the surface soil and the confirmatory and verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

100-IU-6 Operable Unit↗

Population Accommodation for NASA Spacesuit and Hardware

The goal of this work is to review the population accommodation principles and methodologies NASA Johnson Space Center has developed for the spacesuit, vehicle hardware, and habitats. NASA has defined the target population characteristics in the Human-System Integration Requirements based on the US Army Anthropometric Survey (ANSUR) database. However, the data was screened to select the cases of 30-50 year old subjects, given the historical characteristics of the crew. Further, accommodation ranges were defined for critical body measurements, as NASA aims to accommodate 1st percentile female to 99th percentile male of the crew-like population. The historical truncation thresholds of 5-95th percentiles were not used. This ensured that the accommodation range was not limited and accounted for the current astronaut population. A simulation study also showed that less than 68% of the population may have remained after multiple measurement truncations due to the anthropometry covariance patterns if the narrower range was retained. The ranges were also adjusted for long-term trends of body shape changes as predicted by the US National Health and Nutrition Examination Survey. Overall, the requirements were deemed critical to ensure the fit and accommodation of the new suit and space hardware. The requirements have specifically defined boundary cases for verifications and validations, of which the details have proven useful as standards across the different space programs. The specific use and benefits will be further discussed through case studies at the presentation.

Han Kim↗

Dosimetric properties of an amorphous silicon EPID for verification of modulated electron radiotherapy

Purpose: To investigate the dosimetric properties of an electronic portal imaging device (EPID) for electron beam detection and to evaluate its potential for quality assurance (QA) of modulated electron radiotherapy (MERT). Methods: A commercially available EPID was used to detect electron beams shaped by a photon multileaf collimator (MLC) at a source-surface distance of 70 cm. The fundamental dosimetric properties such as reproducibility, dose linearity, field size response, energy response, and saturation were investigated for electron beams. A new method to acquire the flood-field for the EPID calibration was tested. For validation purpose, profiles of open fields and various MLC fields (square and irregular) were measured with a diode in water and compared to the EPID measurements. Finally, in order to use the EPID for QA of MERT delivery, a method was developed to reconstruct EPID two-dimensional (2D) dose distributions in a water-equivalent depth of 1.5 cm. Comparisons were performed with film measurement for static and dynamic monoenergy fields as well as for multienergy fields composed by several segments of different electron energies. Results: The advantageous EPID dosimetric properties already known for photons as reproducibility, linearity with dose, and dose rate were found to be identical for electron detection. The flood-field calibration method was proven to be effective and the EPID was capable to accurately reproduce the dose measured in water at 1.0 cm depth for 6 MeV, 1.3 cm for 9 MeV, and 1.5 cm for 12, 15, and 18 MeV. The deviations between the output factors measured with EPID and in water at these depths were within {+-}1.2% for all the energies with a mean deviation of 0.1%. The average gamma pass rate (criteria: 1.5%, 1.5 mm) for profile comparison between EPID and measurements in water was better than 99% for all the energies considered in this study. When comparing the reconstructed EPID 2D dose distributions at 1.5 cm depth to film measurements, the gamma pass rate (criteria: 2%, 2 mm) was better than 97% for all the tested cases. Conclusions: This study demonstrates the high potential of the EPID for electron dosimetry, and in particular, confirms the possibility to use it as an efficient verification tool for MERT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Open-Source RTOS Space Qualification: An RTEMS Case Study

NASA space-qualification of reusable off-the-shelf real-time operating systems (RTOSs) remains elusive due to several factors notably (1) The diverse nature of RTOSs utilized across NASA, (2) No single NASA space-qualification criteria, lack of verification and validation (V&V) analysis, or test beds, and (3) different RTOS heritages, specifically open-source RTOSs and closed vendor-provided RTOSs. As a leader in simulation test beds, the NASA IV&V Program is poised to help jump-start and lead the space-qualification effort of the open source Real-Time Executive for Multiprocessor Systems (RTEMS) RTOS. RTEMS, as a case-study, can be utilized as an example of how to qualify all RTOSs, particularly the reusable non-commercial (open-source) ones that are gaining usage and popularity across NASA. Qualification will improve the overall safety and mission assurance of RTOSs for NASA-agency wide usage. NASA's involvement in space-qualification of an open-source RTOS such as RTEMS will drive the RTOS industry toward a more qualified and mature open-source RTOS product.

Real-time operating system↗

Performance parameters of a liquid filled ionization chamber array

Purpose: In this work, the properties of the two-dimensional liquid filled ionization chamber array Octavius 1000SRS (PTW-Freiburg, Germany) for use in clinical photon-beam dosimetry are investigated.Methods: Measurements were carried out at an Elekta Synergy and Siemens Primus accelerator. For measurements of stability, linearity, and saturation effects of the 1000SRS array a Semiflex 31013 ionization chamber (PTW-Freiburg, Germany) was used as a reference. The effective point of measurement was determined by TPR measurements of the array in comparison with a Roos chamber (type 31004, PTW-Freiburg, Germany). The response of the array with varying field size and depth of measurement was evaluated using a Semiflex 31010 ionization chamber as a reference. Output factor measurements were carried out with a Semiflex 31010 ionization chamber, a diode (type 60012, PTW-Freiburg, Germany), and the detector array under investigation. The dose response function for a single detector of the array was determined by measuring 1 cm wide slit-beam dose profiles and comparing them against diode-measured profiles. Theoretical aspects of the low pass properties and of the sampling frequency of the detector array were evaluated. Dose profiles measured with the array and the diode detector were compared, and an intensity modulated radiation therapy (IMRT) field was verified using the Gamma-Index method and the visualization of line dose profiles.Results: The array showed a short and long term stability better than 0.1% and 0.2%, respectively. Fluctuations in linearity were found to be within ±0.2% for the vendor specified dose range. Saturation effects were found to be similar to those reported in other studies for liquid-filled ionization chambers. The detector's relative response varied with field size and depth of measurement, showing a small energy dependence accounting for maximum signal deviations of ±2.6% from the reference condition for the setup used. The σ-values of the Gaussian dose response function for a single detector of the array were found to be (0.72 ± 0.25) mm at 6 MV and (0.74 ± 0.25) mm at 15 MV and the corresponding low pass cutoff frequencies are 0.22 and 0.21 mm{sup −1}, respectively. For the inner 5 × 5 cm{sup 2} region and the outer 11 × 11 cm{sup 2} region of the array the Nyquist theorem is fulfilled for maximum sampling frequencies of 0.2 and 0.1 mm{sup −1}, respectively. An IMRT field verification with a Gamma-Index analysis yielded a passing rate of 95.2% for a 3 mm/3% criterion with a TPS calculation as reference.Conclusions: This study shows the applicability of the Octavius 1000SRS in modern dosimetry. Output factor and dose profile measurements illustrated the applicability of the array in small field and stereotactic dosimetry. The high spatial resolution ensures adequate measurements of dose profiles in regular and intensity modulated photon-beam fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of fuel cycle simulator functionalities for analysis of transition to a new fuel cycle

Dynamic fuel cycle simulation tools are intended to model holistic transient nuclear fuel cycle scenarios. As with all simulation tools, fuel cycle simulators require verification through unit tests, benchmark cases, and integral tests. Model validation is a vital aspect as well. Although compara-tive studies have been performed, there is no comprehensive unit test and benchmark library for fuel cycle simulator tools. The objective of this paper is to identify the must test functionalities of a fuel cycle simulator tool within the context of specific problems of interest to the Fuel Cycle Options Campaign within the U.S. Department of Energy s Office of Nuclear Energy. The approach in this paper identifies the features needed to cover the range of promising fuel cycle options identified in the DOE-NE Fuel Cycle Evaluation and Screening (E&S) and categorizes these features to facilitate prioritization. Features were categorized as essential functions, integrating features, and exemplary capabilities. One objective of this paper is to propose a library of unit tests applicable to each of the essential functions. Another underlying motivation for this paper is to encourage an international dialog on the functionalities and standard test methods for fuel cycle simulator tools.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verification of neoclassical toroidal viscosity induced by energetic particles

The thermal particles contributed neoclassical toroidal viscosity (NTV) have been successfully developed and explored by many impressive works such as the study by Shaing et al. [Phys. Plasmas 10, 1443 (2003)] and Zhu et al. [Phys. Rev. Lett. 96, 225002 (2006)]. In this work, the scope of the NTV study is extended to explore the contribution of energetic particles (EPs) through both theory and experiments. In theory, the existence of the NTV torque due to the precessional drift resonance of trapped EPs is identified based on the equivalence between the NTV torque and the perturbed drift kinetic energy [J. Park, Phys. Plasmas 18, 110702 (2011)]. Toroidal modeling with the Magneto Resistive Spectrum - drift Kinetic code [Y. Liu, Phys. Plasmas 15, 112503 (2008)], based on this equivalence, indicates that trapped EPs can contribute a significant amount of the NTV torque. Meanwhile, this work also focuses on developing the dedicated DIII-D experiments in the presence of the n = 2 external magnetic perturbation to verify the EP induced NTV (EP-NTV) by measuring the change of the NTV torque while varying the angle and the voltage of the neutral beam injection. However, the developed experiments have been unable to create conditions necessary to clearly demonstrate the presence of EP-NTV. The main challenge is separating the resonant and non-resonant momentum transport responses in the plasma. Finally, the experience, gained from this study, can help the further exploration of EP-NTV in the future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the use of a single-fiber multipoint plastic scintillation detector for {sup 192}Ir high-dose-rate brachytherapy

Purpose: The goal of this study was to prove the feasibility of using a single-fiber multipoint plastic scintillation detector (mPSD) as an in vivo verification tool during {sup 192}Ir high-dose-rate brachytherapy treatments.Methods: A three-point detector was built and inserted inside a catheter-positioning template placed in a water phantom. A hyperspectral approach was implemented to discriminate the different optical signals composing the light output at the exit of the single collection optical fiber. The mPSD was tested with different source-to-detector positions, ranging from 1 to 5 cm radially and over 10.5 cm along the longitudinal axis of the detector, and with various integration times. Several strategies for improving the accuracy of the detector were investigated. The device's accuracy in detecting source position was also tested.Results: Good agreement with the expected doses was obtained for all of the scintillating elements, with average relative differences from the expected values of 3.4 {+-} 2.1%, 3.0 {+-} 0.7%, and 4.5 {+-} 1.0% for scintillating elements from the distal to the proximal. A dose threshold of 3 cGy improved the general accuracy of the detector. An integration time of 3 s offered a good trade-off between precision and temporal resolution. Finally, the mPSD measured the radioactive source positioning uncertainty to be no more than 0.32 {+-} 0.06 mm. The accuracy and precision of the detector were improved by a dose-weighted function combining the three measurement points and known details about the geometry of the detector construction.Conclusions: The use of a mPSD for high-dose-rate brachytherapy dosimetry is feasible. This detector shows great promise for development of in vivo applications for real-time verification of treatment delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Examining the Ice Nucleating Particles from Southern Great Plains Part II (ExINP-SGP). Field Campaign Report

Knowledge of airborne particulate matter (PM), especially the particles that have supermicron diameters, is key for understanding ice-nucleating particles (INPs). Supported by the Atmospheric Radiation Measurement (ARM) user facility, recent INP measurements at the Southern Great Plains observatory (SGP; 36'' 36' 18→ N, 97° 29' 6'' W) during multiple campaigns, such as SINCE-2014 (DeMott et al. 2015), Examining the Ice-Nucleating Particles from SGP (ExINP-2019; Hiranuma and Vepuri 2020), and Aerosol-Ice Formation Closure Pilot Study (AEROICESTUDY; Knopf et al. 2021a), strongly suggested the contribution of supermicron aerosol particles to observed INP abundance at SGP. However, verification of this hypothesis was hampered since additional offline laboratory analyses require sufficient amounts of collected airborne PM, which was lacking. Therefore, the principal investigators (PIs) conducted a field campaign, named ExINP-SGP II, to collect airborne PM at SGP for complementary laboratory characterization of the particles’ physicochemical properties (including ice nucleation properties). We used a passive particle sampler, which is a 4’ x 4’ x 2” (L x W x D) aluminum pan inside the 12”-high wooden windshield wall at the rooftop deck of the ARM Aerosol Observing System (AOS) trailer to collect dry PM deposits from January to April 2021. Figure 1 shows images of our experimental setup at the site. Additionally, we also collected surface soil near the ARM AOS trailer on 20 November 2020 (Figure 1b) to examine the ground soil dust particles (< 63 µm sieved) for their propensities to initiate immersion freezing compared to collected ambient PM. Surface soil and airborne samples were stored in the chemically inert container separately and kept in a dry, cool place until analyzed.

54 ENVIRONMENTAL SCIENCES↗

H2-O2 auxiliary power unit for Space Shuttle vehicles - A progress report.

Description of a program to establish technology readiness of hydrogen-oxygen (H2-O2) auxiliary power units for use on board the Space Shuttle orbiter vehicle. Fundamental objectives include experimentally establishing an acceptable propellant flow control method, verification of combustor stability, and adequate thermal management. An initial auxiliary power unit (APU) configuration with recycled hydrogen flow has been studied and revised toward greater simplicity and scaling ease. The selected APU is a recuperated open-cycle, turbine-driven unit. Series flow of cryogenic hydrogen removes internally-generated heat and heat from the hydraulic system. The revised configuration schematic and its calculated performance are reviewed. A weight comparison is made between the shuttle baseline hydrazine and H2-O2 APU systems, showing that hydrogen-oxygen APUs have the potential of increasing the payload of the Space Shuttle.

Joyce, J. P.↗

An assessment of transient hydraulics phenomena and its characterization

A systematic search of the open literature was performed with the purpose of identifying the causes, effects, and characterization (modelling and solution techniques) of transient hydraulics phenomena. The governing partial differential equations are presented which were found to be used most often in the literature. Detail survey sheets are shown which contain the type of hydraulics problem, the cause, the modelling, the solution technique utilized, and experimental verification used for each paper. References and source documents are listed and a discussion of the purpose and accomplishments of the study is presented.

Mortimer, R. W.↗

Improving system reliability through formal analysis and use of checks in software

Software is playing increasingly important roles in avionics systems. It is widely used in navigation and, in some cases, in control loops that maintain aircraft stability. To guarantee the safety of flight systems, the FAA requires that critical components have a probability of failure no greater than 10(exp -9) per hour of flight. Software is being used to diagnose system components for failure. SIFT (Software Implemented Fault Tolerance) was a computer system developed to study the use of software to check for failure and manage processor reconfiguration. To guarantee that software satisfies its specifications, formal verification can be used. With this a program and its specification are viewed as mathematical objects, and a mathematical proof is used to show that the program and its specification are equivalent. In previous research, a theory of checking was developed to offer assistance in analyzing specifications and designing run-time checks. In the theory, checking is considered abstractly in terms of n-ary relations much like those of relational database theory. Within the theory check are categorized, checks on input and checks on results are considered, and formal attention is given to the minimization and logical combination of checks. The focus is upon input checks and the obstacles in checking input to critical systems. A central concern is with a property referred to as independence. The concern is with circumstances under which it is possible to apply isolated, independent checks to separate sensor inputs and be assure that all illegal input will be properly detected. Presently, independence is being investigated and checked in the context of the GCS (Guidance and Control System). The GCS simulator is intended for testing software that implements control laws for landing spacecraft. The large number of inputs and their complex interrelationships provide an exciting context in which to investigate independence and the difficulties of supplying input checks.

Staknis, Mark E.↗